메뉴 건너뛰기




Volumn 7493, Issue , 2009, Pages

Simulation of fiber Bragg grating sensor for rebar corrosion

Author keywords

Corrosion of rebar; FBG; Reinforced concrete structure; Sensor; Simulation

Indexed keywords

AUTOMATIC SIGNALS; CONCRETE STRUCTURES; CORROSION RATIO; CORROSION SENSOR; COVER CONCRETE; CROSS SECTIONAL AREA; FIBER BRAGG GRATING (FBG); FIBER BRAGG GRATING SENSORS; FINITE ELEMENT SOFTWARE; IN-BUILDINGS; LINEAR REACTION; MEASURED RESULTS; REAL-TIME HEALTH MONITORING; REBAR CORROSION; REINFORCED CONCRETE STRUCTURE; REINFORCED CONCRETE STRUCTURES; SENSOR SIMULATIONS; SIMULATED RESULTS; STRUCTURAL DAMAGES; STRUCTURE FAILURE; VOLUME EXPANSION; DEGREE OF CORROSION; DURABILITY OF CONCRETE STRUCTURE; FBG; FBG SENSOR; LABORATORY STUDIES; MONITORING POINTS; OPTIMAL SENSOR PLACEMENT;

EID: 72149119054     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.840342     Document Type: Conference Paper
Times cited : (10)

References (8)
  • 1
    • 0842291494 scopus 로고    scopus 로고
    • Corrosion monitoring/detecting of rebar in concrete
    • Wu Jianhua, Zhao Yongtao, "Corrosion monitoring/detecting of rebar in concrete," Corrosion&Protection, 2003, 24(10): 421-431.
    • (2003) Corrosion&Protection , vol.24 , Issue.10 , pp. 421-431
    • Wu, J.1    Zhao, Y.2
  • 2
    • 34247201589 scopus 로고    scopus 로고
    • Determination of Concrete Setting Time Using Electrical Resistivity Measurement
    • May
    • Li Zongjin, Xiao Lianzhen, Wei Xiaosheng, "Determination of Concrete Setting Time Using Electrical Resistivity Measurement," Journal of Materials in Civil Engineering, v 19, n 5, May, 2007.
    • (2007) Journal of Materials in Civil Engineering , vol.19 , Issue.5
    • Li, Z.1    Xiao, L.2    Wei, X.3
  • 3
    • 0033333703 scopus 로고    scopus 로고
    • Nondestructive Techniques to Investigate Corrosion Status in Concrete Structures
    • August
    • Carino, Nicholas J., "Nondestructive Techniques to Investigate Corrosion Status in Concrete Structures," Journal of Performance of Constructed Facilities, Vol. 13, No. 3, August 1999.
    • (1999) Journal of Performance of Constructed Facilities , vol.13 , Issue.3
    • Carino, N.J.1
  • 5
    • 2542448580 scopus 로고    scopus 로고
    • Experimental investigation into early age shrinkage of cement paste by using fibre Bragg gratings
    • Slowik V, Schlattner E, Klink T, "Experimental investigation into early age shrinkage of cement paste by using fibre Bragg gratings," Cement and Concrete Composites 2004, 26:473-9.
    • (2004) Cement and Concrete Composites , vol.26 , pp. 473-479
    • Slowik, V.1    Schlattner, E.2    Klink, T.3
  • 6
    • 0002556255 scopus 로고    scopus 로고
    • Optical fiber grating-based strain and corrosion sensor
    • Jones M.E, Greene J A, "Optical fiber grating-based strain and corrosion sensor," SPIE, 1996(2948): 94-100.
    • (1996) SPIE , vol.2948 , pp. 94-100
    • Jones, M.E.1    Greene, J.A.2
  • 7
    • 23844518939 scopus 로고    scopus 로고
    • Development of fiber Bragg grating sensors for monitoring civil infrastructure
    • Moyo P, Brownjohn JMW, Suresh R, Tjin SC. "Development of fiber Bragg grating sensors for monitoring civil infrastructure," Engineering Structures 2005, 27(12):1828-34.
    • (2005) Engineering Structures , vol.27 , Issue.12 , pp. 1828-1834
    • Moyo, P.1    Brownjohn, J.M.W.2    Suresh, R.3    Tjin, S.C.4
  • 8
    • 0032205178 scopus 로고    scopus 로고
    • Modeling the time-to-corrosion cracking in chloride contaminated reinforced concrete structures
    • Liu Y. P., Weyers R E, "Modeling the time-to-corrosion cracking in chloride contaminated reinforced concrete structures," ACI Materials Journal, 1998, 95(6): 675-681.
    • (1998) ACI Materials Journal , vol.95 , Issue.6 , pp. 675-681
    • Liu, Y.P.1    Weyers, R.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.