메뉴 건너뛰기




Volumn 30, Issue 1, 2014, Pages 249-255

Development of at-line assay to monitor charge variants of MAbs during production

Author keywords

At line monitoring; Bioreactor; Charge variants; HPLC; Monoclonal antibody

Indexed keywords

MONOCLONAL ANTIBODY; RECOMBINANT PROTEIN;

EID: 84893718474     PISSN: 87567938     EISSN: 15206033     Source Type: Journal    
DOI: 10.1002/btpr.1848     Document Type: Article
Times cited : (26)

References (26)
  • 1
    • 84870949388 scopus 로고    scopus 로고
    • What's fueling the biotech engine-2011 to 2012
    • Aggarwal S. What's fueling the biotech engine-2011 to 2012. Nat. Biotechnol. 2012;30:1191-1197.
    • (2012) Nat. Biotechnol , vol.30 , pp. 1191-1197
    • Aggarwal, S.1
  • 2
    • 54349083317 scopus 로고    scopus 로고
    • The cost burden of trastuzumab and bevacizumab therapy for solid tumours in Canada
    • Drucker A, Skedgel C, Virik K, Rayson D, Sellon M, Younis T. The cost burden of trastuzumab and bevacizumab therapy for solid tumours in Canada. Curr Oncol. 2008;15:136-142.
    • (2008) Curr Oncol , vol.15 , pp. 136-142
    • Drucker, A.1    Skedgel, C.2    Virik, K.3    Rayson, D.4    Sellon, M.5    Younis, T.6
  • 3
    • 36048939391 scopus 로고    scopus 로고
    • The cost-effectiveness of bevacizumab in the first-line treatment of metastatic colorectal cancer in England and Wales
    • Tappenden P, Jones R, Paisley S, Carroll C. The cost-effectiveness of bevacizumab in the first-line treatment of metastatic colorectal cancer in England and Wales. Eur J Cancer 2007;43:2487-2494.
    • (2007) Eur J Cancer , vol.43 , pp. 2487-2494
    • Tappenden, P.1    Jones, R.2    Paisley, S.3    Carroll, C.4
  • 4
    • 79953893326 scopus 로고    scopus 로고
    • At what cost does a potential survival advantage of bevacizumab make sense for the primary treatment of ovarian cancer? a cost-effectiveness analysis
    • Cohn DE, Kim KH, Resnick KE, O'Malley DM, Straughn JM. At what cost does a potential survival advantage of bevacizumab make sense for the primary treatment of ovarian cancer? a cost-effectiveness analysis. J Clin Oncol. 2011;29:1247-1251.
    • (2011) J Clin Oncol , vol.29 , pp. 1247-1251
    • Cohn, D.E.1    Kim, K.H.2    Resnick, K.E.3    O'Malley, D.M.4    Straughn, J.M.5
  • 5
    • 70350770990 scopus 로고    scopus 로고
    • The economic value of innovative treatments over the product life cycle: The case of targeted trastuzumab therapy for breast cancer
    • Garrison LP, Veenstra DL. The economic value of innovative treatments over the product life cycle: The case of targeted trastuzumab therapy for breast cancer. Value Health 2009;12:1118-1123.
    • (2009) Value Health , vol.12 , pp. 1118-1123
    • Garrison, L.P.1    Veenstra, D.L.2
  • 6
    • 84876232285 scopus 로고    scopus 로고
    • Systematic review and quality assessment of cost-effectiveness analysis of pharmaceutical therapies for advanced colorectal cancer
    • Leung HWC, Chan ALF, Leung MSH, Lu CL. Systematic review and quality assessment of cost-effectiveness analysis of pharmaceutical therapies for advanced colorectal cancer. Ann Pharmacother. 2013;47:506-518.
    • (2013) Ann Pharmacother , vol.47 , pp. 506-518
    • Leung, H.W.C.1    Chan, A.L.F.2    Leung, M.S.H.3    Lu, C.L.4
  • 10
    • 84886943174 scopus 로고    scopus 로고
    • The clinical effectiveness and cost-effectiveness of rituximab for the first-line treatment of chronic lymphocytic leukaemia: An evidence review of the submission from Roche
    • Main C, Pitt M, Moxham T, Stein K. The clinical effectiveness and cost-effectiveness of rituximab for the first-line treatment of chronic lymphocytic leukaemia: An evidence review of the submission from Roche. Health Technol Assess. 2010;14:27-32.
    • (2010) Health Technol Assess , vol.14 , pp. 27-32
    • Main, C.1    Pitt, M.2    Moxham, T.3    Stein, K.4
  • 12
    • 77954914066 scopus 로고    scopus 로고
    • Characterization of a monoclonal antibody cell culture production process using a quality by design approach
    • Horvath B, Mun M, Laird MW. Characterization of a monoclonal antibody cell culture production process using a quality by design approach. Mol. Biotechnol. 2010;45:203-206.
    • (2010) Mol. Biotechnol , vol.45 , pp. 203-206
    • Horvath, B.1    Mun, M.2    Laird, M.W.3
  • 13
    • 0032440019 scopus 로고    scopus 로고
    • Improving monoclonal antibody pharmacokinetics via chemical modification
    • Sharifi J, Khawli LA, Hornick JL, Epstein AL. Improving monoclonal antibody pharmacokinetics via chemical modification. Q J Nucl Med 1998;42:242-249.
    • (1998) Q J Nucl Med , vol.42 , pp. 242-249
    • Sharifi, J.1    Khawli, L.A.2    Hornick, J.L.3    Epstein, A.L.4
  • 16
    • 84883024756 scopus 로고    scopus 로고
    • Characterization of glycoprotein biopharmaceutical products by Caliper LC90 CE-SDS Gel Technology
    • Beck A, editor. New York: Springer
    • Chen G, Ha S, Rustandi RR. Characterization of glycoprotein biopharmaceutical products by Caliper LC90 CE-SDS Gel Technology. In Beck A, editor. Glycosylation engineering of biopharmaceuticals: Methods and Protocols. New York: Springer; 2013: Vol. 988, 199-209.
    • (2013) Glycosylation engineering of biopharmaceuticals: Methods and Protocols , vol.988 , pp. 199-209
    • Chen, G.1    Ha, S.2    Rustandi, R.R.3
  • 17
    • 84893766497 scopus 로고    scopus 로고
    • Hauser H, editor. Utilizing Roch Cedex bio analyzer for in process monitoring during biotech production, ESACT Meeting on Cell Based Technologies, Vienna, Austria, 2011; BioMed Central Ltd: Vienna, Austria
    • Druhmann D, Reinhard S, Schwarz F, Schaaf C, Greisl K, Nötzel T. In Hauser H, editor. Utilizing Roch Cedex bio analyzer for in process monitoring during biotech production, ESACT Meeting on Cell Based Technologies, Vienna, Austria, 2011; BioMed Central Ltd: Vienna, Austria, 2011.
    • (2011)
    • Druhmann, D.1    Reinhard, S.2    Schwarz, F.3    Schaaf, C.4    Greisl, K.5    Nötzel, T.6
  • 18
    • 34447545690 scopus 로고    scopus 로고
    • The fundamental aspects and applications of Agilent HPLC-Chip
    • Yin HF, Killeen K. The fundamental aspects and applications of Agilent HPLC-Chip. J Sep Sci. 2007;30:1427-1434.
    • (2007) J Sep Sci , vol.30 , pp. 1427-1434
    • Yin, H.F.1    Killeen, K.2
  • 19
    • 76849117155 scopus 로고    scopus 로고
    • Cell culture monitoring via an auto-sampler and an integrated multi-functional off-line analyzer
    • Derfus GE, Abramzon D, Tung M, Chang D, Kiss R, Amanullah A. Cell culture monitoring via an auto-sampler and an integrated multi-functional off-line analyzer. Biotechnol Prog. 2010;26:284-292.
    • (2010) Biotechnol Prog , vol.26 , pp. 284-292
    • Derfus, G.E.1    Abramzon, D.2    Tung, M.3    Chang, D.4    Kiss, R.5    Amanullah, A.6
  • 20
    • 84857583357 scopus 로고    scopus 로고
    • A convergence of new products and technologies changes the game
    • Scott C. A convergence of new products and technologies changes the game. Biopharm Int Supplement 2010;8:10-15.
    • (2010) Biopharm Int Supplement , vol.8 , pp. 10-15
    • Scott, C.1
  • 21
    • 0021890952 scopus 로고
    • Automated tandem high-performance liquid-chromatographic system for separation of extremely complex peptide mixtures
    • Takahashi N, Ishioka N, Takahashi Y, Putnam FW. Automated tandem high-performance liquid-chromatographic system for separation of extremely complex peptide mixtures. J. Chromatogr. 1985;326:407-418.
    • (1985) J. Chromatogr , vol.326 , pp. 407-418
    • Takahashi, N.1    Ishioka, N.2    Takahashi, Y.3    Putnam, F.W.4
  • 22
    • 0037084079 scopus 로고    scopus 로고
    • An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation
    • Wagner K, Miliotis T, Marko-Varga G, Bischoff R, Unger KK. An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation. Anal Chem. 2002;74:809-820.
    • (2002) Anal Chem , vol.74 , pp. 809-820
    • Wagner, K.1    Miliotis, T.2    Marko-Varga, G.3    Bischoff, R.4    Unger, K.K.5
  • 23
    • 34447514281 scopus 로고    scopus 로고
    • Fully automated two-dimensional high-performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry for the determination of oligosaccharides in glycopeptides after enzymic fluorescence labeling
    • Min JZ, Toyo'oka T, Kurihara T, Fukushima T, Inagaki S. Fully automated two-dimensional high-performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry for the determination of oligosaccharides in glycopeptides after enzymic fluorescence labeling. J Chromatogr A 2007;1160:120-127.
    • (2007) J Chromatogr A , vol.1160 , pp. 120-127
    • Min, J.Z.1    Toyo'oka, T.2    Kurihara, T.3    Fukushima, T.4    Inagaki, S.5
  • 24
    • 34247265006 scopus 로고    scopus 로고
    • Extracellular proteome of human hepatoma cell, HepG2 analyzed using two-dimensional liquid chromatography coupled with tandem mass spectrometry
    • Yamashita R, Fujiwara Y, Ikari K, Hamada K, Otomo A, Yasuda K, Noda M, Kaburagi Y. Extracellular proteome of human hepatoma cell, HepG2 analyzed using two-dimensional liquid chromatography coupled with tandem mass spectrometry. Mol Cell Biochem 2007;298:83-92.
    • (2007) Mol Cell Biochem , vol.298 , pp. 83-92
    • Yamashita, R.1    Fujiwara, Y.2    Ikari, K.3    Hamada, K.4    Otomo, A.5    Yasuda, K.6    Noda, M.7    Kaburagi, Y.8
  • 26
    • 0028915061 scopus 로고
    • The asparagine-linked carbohydrate of honeybee venom hyaluronidase
    • Kubelka V, Altmann F, Marz L. The asparagine-linked carbohydrate of honeybee venom hyaluronidase. Glycoconj J 1995;12:77-83.
    • (1995) Glycoconj J , vol.12 , pp. 77-83
    • Kubelka, V.1    Altmann, F.2    Marz, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.