메뉴 건너뛰기




Volumn 72, Issue , 2014, Pages 234-241

A numerical study on the temperature overshoot characteristic of a realistic thermoelectric module under a current pulse operation

Author keywords

Current pulse; Temperature overshoot; Thermoelectric module; Transient cooling

Indexed keywords

CRITICAL VALUE; CURRENT PULSE; OPERATION CONDITIONS; TEMPERATURE OVERSHOOT; THERMAL CONDUCTANCE; THERMO-ELECTRIC MODULES; TRANSIENT COOLING; TRANSIENT TEMPERATURE;

EID: 84893378061     PISSN: 00179310     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijheatmasstransfer.2014.01.017     Document Type: Article
Times cited : (36)

References (27)
  • 1
    • 0001508298 scopus 로고
    • Cooling of thermoelectric cells under nonstationary conditions
    • L. Stilbans, and N. Fedorovich Cooling of thermoelectric cells under nonstationary conditions Sov. Phys. Tech. Phys. 3 1958 460 463
    • (1958) Sov. Phys. Tech. Phys. , vol.3 , pp. 460-463
    • Stilbans, L.1    Fedorovich, N.2
  • 2
    • 0036574719 scopus 로고    scopus 로고
    • The maximum temperature difference and polar characteristic of two-stage thermoelectric coolers
    • DOI 10.1016/S0011-2275(02)00035-8, PII S0011227502000358
    • X.C. Xuan, K.C. Ng, C. Yap, and H.T. Chua The maximum temperature difference and polar characteristic of two-stage thermoelectric coolers Cryogenics 42 5 2002 273 278 (Pubitemid 34624067)
    • (2002) Cryogenics , vol.42 , Issue.5 , pp. 273-278
    • Xuan, X.C.1    Ng, K.C.2    Yap, C.3    Chua, H.T.4
  • 4
    • 0017679390 scopus 로고
    • Numerical analysis of transient behavior of thermoelectric coolers
    • G.E. Hoyos, K.R. Rao, and D. Jerger Numerical analysis of transient behavior of thermoelectric coolers Energy Convers. 17 1 1977 23 29 (Pubitemid 8595072)
    • (1977) Energy Convers , vol.17 , Issue.1 , pp. 23-29
    • Hoyos, G.E.1    Rao, K.R.2    Jerger, D.3
  • 5
    • 0017701979 scopus 로고
    • Fast transient response of novel peltier junctions
    • G.E. Hoyos, K.R. Rao, and D. Jerger Fast transient response of novel Peltier junctions Energy Convers. 17 1 1977 45 54 (Pubitemid 8595076)
    • (1977) Energy Convers , vol.17 , Issue.1 , pp. 45-54
    • Hoyos, G.E.1    Rao, K.R.2    Jerger, D.3
  • 6
    • 0010197377 scopus 로고
    • Fast transient behavior of thermoelectric coolers with high current pulse and finite cold junction
    • R.L. Field, and H.A. Blum Fast transient behavior of thermoelectric coolers with high current pulse and finite cold junction Energy Convers. 19 3 1979 159 165
    • (1979) Energy Convers. , vol.19 , Issue.3 , pp. 159-165
    • Field, R.L.1    Blum, H.A.2
  • 8
    • 84893398279 scopus 로고    scopus 로고
    • Transient thermoelectric cooling of thin film devices
    • Cambridge Univ. Press
    • A. Ravi Kumar, R. Yang, G. Chen, and J.P. Fleurial Transient thermoelectric cooling of thin film devices MRS Proceedings 2000 Cambridge Univ. Press
    • (2000) MRS Proceedings
    • Ravi Kumar, A.1    Yang, R.2    Chen, G.3    Fleurial, J.P.4
  • 12
    • 8644235078 scopus 로고    scopus 로고
    • Improved supercooling in transient thermoelectrics
    • T. Thonhauser, G.D. Mahan, L. Zikatanov, and J. Roe Improved supercooling in transient thermoelectrics Appl. Phys. Lett. 85 15 2004 3247 3249
    • (2004) Appl. Phys. Lett. , vol.85 , Issue.15 , pp. 3247-3249
    • Thonhauser, T.1    Mahan, G.D.2    Zikatanov, L.3    Roe, J.4
  • 13
    • 15744380526 scopus 로고    scopus 로고
    • Transient cooling of thermoelectric coolers and its applications for microdevices
    • DOI 10.1016/j.enconman.2004.07.004, PII S0196890404001918
    • R. Yang, G. Chen, A. Ravi Kumar, G.J. Snyder, and J.-P. Fleurial Transient cooling of thermoelectric coolers and its applications for microdevices Energy Convers. Manage. 46 9-10 2005 1407 1421 (Pubitemid 40415115)
    • (2005) Energy Conversion and Management , vol.46 , Issue.9-10 , pp. 1407-1421
    • Yang, R.1    Chen, G.2    Kumar, A.R.3    Snyder, G.J.4    Fleurial, J.-P.5
  • 14
    • 33745361196 scopus 로고    scopus 로고
    • Thermodynamic modelling of a solid state thermoelectric cooling device: Temperature-entropy analysis
    • DOI 10.1016/j.ijheatmasstransfer.2006.02.047, PII S0017931006001876
    • A. Chakraborty, B.B. Saha, S. Koyama, and K.C. Ng Thermodynamic modelling of a solid state thermoelectric cooling device: temperature-entropy analysis Int. J. Heat Mass Transfer 49 19-20 2006 3547 3554 (Pubitemid 43946911)
    • (2006) International Journal of Heat and Mass Transfer , vol.49 , Issue.19-20 , pp. 3547-3554
    • Chakraborty, A.1    Saha, B.B.2    Koyama, S.3    Ng, K.C.4
  • 15
    • 33646011517 scopus 로고    scopus 로고
    • Thermodynamic formulation of temperature-entropy diagram for the transient operation of a pulsed thermoelectric cooler
    • A. Chakraborty, and K.C. Ng Thermodynamic formulation of temperature-entropy diagram for the transient operation of a pulsed thermoelectric cooler Int. J. Heat Mass Transfer 49 11-12 2006 1845 1850
    • (2006) Int. J. Heat Mass Transfer , vol.49 , Issue.1112 , pp. 1845-1850
    • Chakraborty, A.1    Ng, K.C.2
  • 17
    • 40949152930 scopus 로고    scopus 로고
    • Impact of interface resistance on pulsed thermoelectric cooling
    • Y.S. Ju Impact of interface resistance on pulsed thermoelectric cooling J. Heat Transfer 130 1 2008 014502
    • (2008) J. Heat Transfer , vol.130 , Issue.1 , pp. 014502
    • Ju, Y.S.1
  • 19
    • 84864141003 scopus 로고    scopus 로고
    • The transient behavior of Peltier junctions pulsed with supercooling
    • J.N. Mao, H.X. Chen, H. Jia, and X.L. Qian The transient behavior of Peltier junctions pulsed with supercooling J. Appl. Phys. 112 1 2012 014514 014519
    • (2012) J. Appl. Phys. , vol.112 , Issue.1 , pp. 014514-014519
    • Mao, J.N.1    Chen, H.X.2    Jia, H.3    Qian, X.L.4
  • 20
    • 81855198848 scopus 로고    scopus 로고
    • Solution to the 1-D unsteady heat conduction equation with internal Joule heat generation for thermoelectric devices
    • A. Montecucco, J.R. Buckle, and A.R. Knox Solution to the 1-D unsteady heat conduction equation with internal Joule heat generation for thermoelectric devices Appl. Therm. Eng. 35 0 2012 177 184
    • (2012) Appl. Therm. Eng. , vol.35 , Issue.0 , pp. 177-184
    • Montecucco, A.1    Buckle, J.R.2    Knox, A.R.3
  • 21
    • 84862817671 scopus 로고    scopus 로고
    • Numerical and experimental analysis of transient supercooling effect of voltage pulse on thermoelectric element
    • L.M. Shen, F. Xiao, H.X. Chen, and S.W. Wang Numerical and experimental analysis of transient supercooling effect of voltage pulse on thermoelectric element Int. J. Refrig. 35 4 2012 1156 1165
    • (2012) Int. J. Refrig. , vol.35 , Issue.4 , pp. 1156-1165
    • Shen, L.M.1    Xiao, F.2    Chen, H.X.3    Wang, S.W.4
  • 22
    • 76749136137 scopus 로고    scopus 로고
    • A three-dimensional theoretical model for predicting transient thermal behavior of thermoelectric coolers
    • C.-H. Cheng, S.-Y. Huang, and T.C. Cheng A three-dimensional theoretical model for predicting transient thermal behavior of thermoelectric coolers Int. J. Heat Mass Transfer 53 9-10 2010 2001 2011
    • (2010) Int. J. Heat Mass Transfer , vol.53 , Issue.910 , pp. 2001-2011
    • Cheng, C.-H.1    Huang, S.-Y.2    Cheng, T.C.3
  • 23
    • 84867704574 scopus 로고    scopus 로고
    • Development of a non-uniform-current model for predicting transient thermal behavior of thermoelectric coolers
    • C.-H. Cheng, and S.-Y. Huang Development of a non-uniform-current model for predicting transient thermal behavior of thermoelectric coolers Appl. Energy 100 0 2012 326 335
    • (2012) Appl. Energy , vol.100 , Issue.0 , pp. 326-335
    • Cheng, C.-H.1    Huang, S.-Y.2
  • 26
    • 80053907059 scopus 로고    scopus 로고
    • A new method and computer-controlled system for measuring the time constant of real thermoelectric modules
    • R. Ahiska, S. Dislitas, and G. Omer A new method and computer-controlled system for measuring the time constant of real thermoelectric modules Energy Convers. Manage. 53 1 2012 314 321
    • (2012) Energy Convers. Manage. , vol.53 , Issue.1 , pp. 314-321
    • Ahiska, R.1    Dislitas, S.2    Omer, G.3
  • 27
    • 84866561674 scopus 로고    scopus 로고
    • Characterization of a thermoelectric cooler based thermal management system under different operating conditions
    • M.K. Russel, D. Ewing, and C.Y. Ching Characterization of a thermoelectric cooler based thermal management system under different operating conditions Appl. Therm. Eng. 50 1 2013 652 659
    • (2013) Appl. Therm. Eng. , vol.50 , Issue.1 , pp. 652-659
    • Russel, M.K.1    Ewing, D.2    Ching, C.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.