-
1
-
-
67650102825
-
Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: The Buenos Aires experience
-
Lylyk P, Miranda C, Ceratto R, et al. Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: the Buenos Aires experience. Neurosurgery 2009;64:632-42
-
(2009)
Neurosurgery
, vol.64
, pp. 632-642
-
-
Lylyk, P.1
Miranda, C.2
Ceratto, R.3
-
2
-
-
84877616061
-
Investigation of intracranial aneurysm hemodynamics following flow diverter stent treatment
-
Zhang Y, Chong W, Qian Y. Investigation of intracranial aneurysm hemodynamics following flow diverter stent treatment. Med Eng Phys 2013;35:608-15
-
(2013)
Med Eng Phys
, vol.35
, pp. 608-615
-
-
Zhang, Y.1
Chong, W.2
Qian, Y.3
-
3
-
-
84856082356
-
Immediate and midterm results following treatment of unruptured intracranial aneurysms with the Pipeline embolization device
-
McAuliffe W, Wycoco V, Rice H, et al. Immediate and midterm results following treatment of unruptured intracranial aneurysms with the Pipeline embolization device. AJNR Am J Neuroradiol 2012;33:164-70
-
(2012)
AJNR Am J Neuroradiol
, vol.33
, pp. 164-170
-
-
McAuliffe, W.1
Wycoco, V.2
Rice, H.3
-
4
-
-
84876177633
-
Canadian experience with the Pipeline embolization device for repair of unruptured intracranial aneurysms
-
O'Kelly CJ, Spears J, Chow M, et al. Canadian experience with the Pipeline embolization device for repair of unruptured intracranial aneurysms. AJNR Am J Neuroradiol 2013;34:381-87
-
(2013)
AJNR Am J Neuroradiol
, vol.34
, pp. 381-387
-
-
O'Kelly, C.J.1
Spears, J.2
Chow, M.3
-
5
-
-
84873623403
-
Midterm and long-term fol-low-up of cerebral aneurysms treated with flow diverter devices: A single-center experience
-
Piano M, Valvassori L, Quilici L, et al. Midterm and long-term fol-low-up of cerebral aneurysms treated with flow diverter devices: a single-center experience. J Neurosurg 2013;118:408-16
-
(2013)
J Neurosurg
, vol.118
, pp. 408-416
-
-
Piano, M.1
Valvassori, L.2
Quilici, L.3
-
6
-
-
84870016919
-
Intracranial aneurysms: Mid-term outcome of Pipeline embolization device: A prospective study in 143 patients with 178 aneurysms
-
Yu SC, Kwok CK, Cheng PW, et al. Intracranial aneurysms: mid-term outcome of Pipeline embolization device: a prospective study in 143 patients with 178 aneurysms. Radiology 2012;265:893-901
-
(2012)
Radiology
, vol.265
, pp. 893-901
-
-
Yu, S.C.1
Kwok, C.K.2
Cheng, P.W.3
-
7
-
-
79958051274
-
Mural destabilization after aneurysm treatment with a flow-diverting device: A report of two cases
-
Hampton T, Walsh D, Tolias C, et al. Mural destabilization after aneurysm treatment with a flow-diverting device: a report of two cases. J Neurointerv Surg 2011;3:167-71
-
(2011)
J Neurointerv Surg
, vol.3
, pp. 167-171
-
-
Hampton, T.1
Walsh, D.2
Tolias, C.3
-
8
-
-
84866775099
-
Delayed intraparenchymal hemorrhage following Pipeline embolization device treatment for a giant recanalized ophthalmic aneurysm
-
Velat GJ, Fargen KM, Lawson MF, et al. Delayed intraparenchymal hemorrhage following Pipeline embolization device treatment for a giant recanalized ophthalmic aneurysm. J Neurointerv Surg 2012; 4:e24
-
(2012)
J Neurointerv Surg
, vol.4
-
-
Velat, G.J.1
Fargen, K.M.2
Lawson, M.F.3
-
9
-
-
78651498261
-
Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment
-
Kulcsar Z, Houdart E, Bonafe A, et al. Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol 2011;32:20-25
-
(2011)
AJNR Am J Neuroradiol
, vol.32
, pp. 20-25
-
-
Kulcsar, Z.1
Houdart, E.2
Bonafe, A.3
-
10
-
-
7644241840
-
Magnitude and role of wall shear stress on cerebral aneurysm: Computational fluid dynamic study of 20 middle cerebral artery aneurysms
-
Shojima M, Oshima M, Takagi K, et al. Magnitude and role of wall shear stress on cerebral aneurysm: computational fluid dynamic study of 20 middle cerebral artery aneurysms. Stroke 2004; 35:2500-05
-
(2004)
Stroke
, vol.35
, pp. 2500-2505
-
-
Shojima, M.1
Oshima, M.2
Takagi, K.3
-
11
-
-
84872935448
-
Low wall shear stress is independently associated with the rupture status of middle cerebral artery aneurysms
-
Miura Y, Ishida F, Umeda Y, et al. Low wall shear stress is independently associated with the rupture status of middle cerebral artery aneurysms. Stroke 2013;44:519-21
-
(2013)
Stroke
, vol.44
, pp. 519-521
-
-
Miura, Y.1
Ishida, F.2
Umeda, Y.3
-
12
-
-
34249823676
-
Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation
-
Meng H, Wang Z, Hoi Y, et al. Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation. Stroke 2007;38:1924-31
-
(2007)
Stroke
, vol.38
, pp. 1924-1931
-
-
Meng, H.1
Wang, Z.2
Hoi, Y.3
-
13
-
-
84864545292
-
Influence of hemodynamics on recanalization of totally occluded intracranial aneurysms: A patient-specific computational fluid dynamic simulation study
-
Li C, Wang S, Chen J, et al. Influence of hemodynamics on recanalization of totally occluded intracranial aneurysms: a patient-specific computational fluid dynamic simulation study. J Neurosurg 2012;117:276-83
-
(2012)
J Neurosurg
, vol.117
, pp. 276-283
-
-
Li, C.1
Wang, S.2
Chen, J.3
-
14
-
-
84867582023
-
Flow diversion treatment: Intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis
-
Kulcsar Z, Augsburger L, Reymond P, et al. Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis. Acta Neurochir (Wien) 2012;154:1827-34
-
(2012)
Acta Neurochir (Wien)
, vol.154
, pp. 1827-1834
-
-
Kulcsar, Z.1
Augsburger, L.2
Reymond, P.3
-
15
-
-
84870941553
-
Effects of flow-diverting device oversizing on hemodynamics alteration in cerebral aneurysms
-
Mut F, Cebral JR. Effects of flow-diverting device oversizing on hemodynamics alteration in cerebral aneurysms. AJNR Am J Neuroradiol 2012;33:2010-16
-
(2012)
AJNR Am J Neuroradiol
, vol.33
, pp. 2010-2016
-
-
Mut, F.1
Cebral, J.R.2
-
16
-
-
78651492652
-
Aneurysm rupture following treatment with flow-diverting stents: Computational hemodynamics analysis of treatment
-
Cebral JR, Mut F, Raschi M, et al. Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment. AJNR Am J Neuroradiol 2011;32:27-33
-
(2011)
AJNR Am J Neuroradiol
, vol.32
, pp. 27-33
-
-
Cebral, J.R.1
Mut, F.2
Raschi, M.3
-
17
-
-
79960709697
-
The adverse effects of flow-diverter stent-like devices on the flow pattern of saccular intracranial aneurysm models: Computational fluid dynamics study
-
Hassan T, Ahmed YM, Hassan AA. The adverse effects of flow-diverter stent-like devices on the flow pattern of saccular intracranial aneurysm models: computational fluid dynamics study. Acta Neurochir (Wien) 2011;153:1633-40
-
(2011)
Acta Neurochir (Wien)
, vol.153
, pp. 1633-1640
-
-
Hassan, T.1
Ahmed, Y.M.2
Hassan, A.A.3
-
18
-
-
34249881606
-
Sensitivity of patientspecific numerical simulation of cerebral aneurysm hemodynamics to inflow boundary conditions
-
Venugopal P, Valentino D, Schmitt H, et al. Sensitivity of patientspecific numerical simulation of cerebral aneurysm hemodynamics to inflow boundary conditions. J Neurosurg 2007;106:1051-60
-
(2007)
J Neurosurg
, vol.106
, pp. 1051-1060
-
-
Venugopal, P.1
Valentino, D.2
Schmitt, H.3
-
19
-
-
79951554274
-
Computational hemodynamics in cerebral aneurysms: The effects of modeled versus measured boundary conditions
-
Marzo A, Singh P, Larrabide I, et al. Computational hemodynamics in cerebral aneurysms: the effects of modeled versus measured boundary conditions. Ann Biomed Eng 2011;39:884-96
-
(2011)
Ann Biomed Eng
, vol.39
, pp. 884-896
-
-
Marzo, A.1
Singh, P.2
Larrabide, I.3
-
20
-
-
79953854881
-
"Stent view" flat-detector CTand stent-assisted treatment strategies for complex intracranial aneurysms
-
Levitt MR, Cooke DL, Ghodke BV, et al. "Stent view" flat-detector CTand stent-assisted treatment strategies for complex intracranial aneurysms. World Neurosurg 2011;75:275-78
-
(2011)
World Neurosurg
, vol.75
, pp. 275-278
-
-
Levitt, M.R.1
Cooke, D.L.2
Ghodke, B.V.3
-
21
-
-
0031055838
-
Practical coronary physiology: Clinical application of the Doppler flow velocity guide wire
-
Bach RG, Kern MJ. Practical coronary physiology: clinical application of the Doppler flow velocity guide wire. Cardiol Clin 1997;15:77-99
-
(1997)
Cardiol Clin
, vol.15
, pp. 77-99
-
-
Bach, R.G.1
Kern, M.J.2
-
22
-
-
76749119440
-
Intracranial blood-flow velocity and pressure measurements using an intra-arterial dual-sensor guidewire
-
Ferns SP, Schneiders JJ, Siebes M, et al. Intracranial blood-flow velocity and pressure measurements using an intra-arterial dual-sensor guidewire. AJNR Am J Neuroradiol 2010;31:324-26
-
(2010)
AJNR Am J Neuroradiol
, vol.31
, pp. 324-326
-
-
Ferns, S.P.1
Schneiders, J.J.2
Siebes, M.3
-
23
-
-
84867768659
-
Comparison of phasecontrast MR imaging and endovascular sonography for intracranial blood flow velocity measurements
-
Schneiders JJ, Ferns SP, van Ooij P, et al. Comparison of phasecontrast MR imaging and endovascular sonography for intracranial blood flow velocity measurements. AJNR Am J Neuroradiol 2012;33:1786-90
-
(2012)
AJNR Am J Neuroradiol
, vol.33
, pp. 1786-1790
-
-
Schneiders, J.J.1
Ferns, S.P.2
Van Ooij, P.3
-
24
-
-
0028354183
-
Use of a Doppler guide wire for intravascular blood flow measurements: A validation study for potential neurologic endovascular applications
-
Chaloupka JC, Viñuela F, Kimme-Smith C, et al. Use of a Doppler guide wire for intravascular blood flow measurements: a validation study for potential neurologic endovascular applications. AJNR Am J Neuroradiol 1994;15:509-17
-
(1994)
AJNR Am J Neuroradiol
, vol.15
, pp. 509-517
-
-
Chaloupka, J.C.1
Viñuela, F.2
Kimme-Smith, C.3
-
25
-
-
79951555876
-
Intracranial stents being modeled as a porous medium: Flow simulation in stented cerebral aneurysms
-
Augsburger L, Reymond P, Rufenacht DA, et al. Intracranial stents being modeled as a porous medium: flow simulation in stented cerebral aneurysms. Ann Biomed Eng 2011;39:850-63
-
(2011)
Ann Biomed Eng
, vol.39
, pp. 850-863
-
-
Augsburger, L.1
Reymond, P.2
Rufenacht, D.A.3
-
26
-
-
84876718987
-
Intra-aneurysmal pressure and flow changes induced by flow diverters: Relation to aneurysm size and shape
-
Larrabide I, Aguilar ML, Morales HG, et al. Intra-aneurysmal pressure and flow changes induced by flow diverters: relation to aneurysm size and shape. AJNR Am J Neuroradiol 2013;34:816-22
-
(2013)
AJNR Am J Neuroradiol
, vol.34
, pp. 816-822
-
-
Larrabide, I.1
Aguilar, M.L.2
Morales, H.G.3
-
27
-
-
84881526451
-
Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: High intra-aneurysmal pressure remains regardless of flow velocity reduction
-
Shobayashi Y, Tateshima S, Kakizaki R, et al. Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction. J Neurointerv Surg 2013; 5 Suppl 3:iii38-42
-
(2013)
J Neurointerv Surg
, vol.5
, Issue.SUPPL. 3
-
-
Shobayashi, Y.1
Tateshima, S.2
Kakizaki, R.3
-
29
-
-
80052304983
-
Validation of a patient-specific one-dimensional model of the systemic arterial tree
-
Reymond P, Bohraus Y, Perren F, et al. Validation of a patient-specific one-dimensional model of the systemic arterial tree. Am J Physiol Heart Circ Physiol 2011;301:H1173-82
-
(2011)
Am J Physiol Heart Circ Physiol
, vol.301
-
-
Reymond, P.1
Bohraus, Y.2
Perren, F.3
-
30
-
-
20044391646
-
Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries
-
Ford MD, Alperin N, Lee SH, et al. Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiol Meas 2005;26:477-88
-
(2005)
Physiol Meas
, vol.26
, pp. 477-488
-
-
Ford, M.D.1
Alperin, N.2
Lee, S.H.3
-
31
-
-
65549116320
-
Intra-aneurysmal flow patterns and wall shear stresses calculated with computational flow dynamics in an anterior communicating artery aneurysm depend on knowledge of patient-specific inflow rates
-
Karmonik C, Yen C, Grossman RG, et al. Intra-aneurysmal flow patterns and wall shear stresses calculated with computational flow dynamics in an anterior communicating artery aneurysm depend on knowledge of patient-specific inflow rates. Acta Neurochir (Wien) 2009;151:479-85
-
(2009)
Acta Neurochir (Wien)
, vol.151
, pp. 479-485
-
-
Karmonik, C.1
Yen, C.2
Grossman, R.G.3
-
32
-
-
77956188829
-
Temporal variations of wall shear stress parameters in intracranial aneurysms-importance of pa-tient-specific inflow waveforms for CFD calculations
-
Karmonik C, Yen C, Diaz O, et al. Temporal variations of wall shear stress parameters in intracranial aneurysms-importance of pa-tient-specific inflow waveforms for CFD calculations. Acta Neurochir (Wien) 2010;152:1391-98
-
(2010)
Acta Neurochir (Wien)
, vol.152
, pp. 1391-1398
-
-
Karmonik, C.1
Yen, C.2
Diaz, O.3
-
33
-
-
0018903323
-
Reduction in regional cerebral blood flow during normal aging in man
-
Melamed E, Lavy S, Bentin S, et al. Reduction in regional cerebral blood flow during normal aging in man. Stroke 1980;11:31-35
-
(1980)
Stroke
, vol.11
, pp. 31-35
-
-
Melamed, E.1
Lavy, S.2
Bentin, S.3
-
34
-
-
77049119213
-
Characterization of volumetric flow rate waveforms at the carotid bifurcations of older adults
-
Hoi Y, Wasserman BA, Xie YJ, et al. Characterization of volumetric flow rate waveforms at the carotid bifurcations of older adults. Physiol Meas 2010;31:291-302
-
(2010)
Physiol Meas
, vol.31
, pp. 291-302
-
-
Hoi, Y.1
Wasserman, B.A.2
Xie, Y.J.3
-
35
-
-
1642500839
-
Computational simulation of therapeutic parent artery occlusion to treat giant vertebrobasilar aneurysm
-
Hassan T, Ezura M, Timofeev EV, et al. Computational simulation of therapeutic parent artery occlusion to treat giant vertebrobasilar aneurysm. AJNR Am J Neuroradiol 2004;25:63-68
-
(2004)
AJNR Am J Neuroradiol
, vol.25
, pp. 63-68
-
-
Hassan, T.1
Ezura, M.2
Timofeev, E.V.3
-
36
-
-
84856965554
-
Comprehensive validation of computational fluid dynamics simulations of in-vivo blood flow in patientspecific cerebral aneurysms
-
Sun Q, Groth A, Aach T. Comprehensive validation of computational fluid dynamics simulations of in-vivo blood flow in patientspecific cerebral aneurysms. Med Phys 2012;39:742-54
-
(2012)
Med Phys
, vol.39
, pp. 742-754
-
-
Sun, Q.1
Groth, A.2
Aach, T.3
-
37
-
-
0142072546
-
Computational approach to quantifying hemodynamic forces in giant cerebral aneurysms
-
Jou LD, Quick CM, Young WL, et al. Computational approach to quantifying hemodynamic forces in giant cerebral aneurysms. AJNR Am J Neuroradiol 2003;24:1804-10
-
(2003)
AJNR Am J Neuroradiol
, vol.24
, pp. 1804-1810
-
-
Jou, L.D.1
Quick, C.M.2
Young, W.L.3
-
38
-
-
60549086615
-
Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: Comparison with computational fluid dynamics
-
Boussel L, Rayz V, Martin A, et al. Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: comparison with computational fluid dynamics. Magn Reson Med 2009; 61:409-17
-
(2009)
Magn Reson Med
, vol.61
, pp. 409-417
-
-
Boussel, L.1
Rayz, V.2
Martin, A.3
-
39
-
-
54849426265
-
Numerical simulations of flow in cerebral aneurysms: Comparison of CFD results and in vivo MRI measurements
-
Rayz VL, Boussel L, Acevedo-Bolton G, et al. Numerical simulations of flow in cerebral aneurysms: comparison of CFD results and in vivo MRI measurements. J Biomech Eng 2008;130:051011
-
(2008)
J Biomech Eng
, vol.130
, pp. 051011
-
-
Rayz, V.L.1
Boussel, L.2
Acevedo-Bolton, G.3
-
40
-
-
33748337334
-
Transcranial Doppler grading criteria for basilar artery vasospasm
-
Sviri GE, Ghodke B, Britz GW, et al. Transcranial Doppler grading criteria for basilar artery vasospasm. Neurosurgery 2006;59:360-66
-
(2006)
Neurosurgery
, vol.59
, pp. 360-366
-
-
Sviri, G.E.1
Ghodke, B.2
Britz, G.W.3
-
41
-
-
0141864328
-
Assessment of transcranial color-coded duplex sonography for the surveillance of intracranial aneurysms treated with Guglielmi detachable coils
-
Turner CL, Higgins JN, Kirkpatrick PJ. Assessment of transcranial color-coded duplex sonography for the surveillance of intracranial aneurysms treated with Guglielmi detachable coils. Neurosurgery 2003;53:866-71
-
(2003)
Neurosurgery
, vol.53
, pp. 866-871
-
-
Turner, C.L.1
Higgins, J.N.2
Kirkpatrick, P.J.3
-
42
-
-
18344375474
-
Prediction of early cerebral outcome by transcranial Doppler monitoring in carotid bifurcation angioplasty and stenting
-
Ackerstaff RG, Suttorp MJ, van den Berg JC, et al. Prediction of early cerebral outcome by transcranial Doppler monitoring in carotid bifurcation angioplasty and stenting. J Vasc Surg 2005;41:618-24
-
(2005)
J Vasc Surg
, vol.41
, pp. 618-624
-
-
Ackerstaff, R.G.1
Suttorp, M.J.2
Van Den Berg, J.C.3
-
43
-
-
78651496022
-
Velocity measurements in the middle cerebral arteries of healthy volunteers using 3D radial phase-contrast HYPRFlow: Comparison with transcranial Doppler sonography and 2D phase-contrast MR imaging
-
Chang W, Landgraf B, Johnson KM, et al. Velocity measurements in the middle cerebral arteries of healthy volunteers using 3D radial phase-contrast HYPRFlow: comparison with transcranial Doppler sonography and 2D phase-contrast MR imaging. AJNR Am J Neuroradiol 2011;32:54-59
-
(2011)
AJNR Am J Neuroradiol
, vol.32
, pp. 54-59
-
-
Chang, W.1
Landgraf, B.2
Johnson, K.M.3
-
44
-
-
67649678851
-
Hemodynamics in normal cerebral arteries: Qualitative comparison of 4D phase-contrast magnetic resonance and image-based computational fluid dynamics
-
Cebral JR, Putman CM, Alley MT, et al. Hemodynamics in normal cerebral arteries: qualitative comparison of 4D phase-contrast magnetic resonance and image-based computational fluid dynamics. J Eng Math 2009;64:367-78
-
(2009)
J Eng Math
, vol.64
, pp. 367-378
-
-
Cebral, J.R.1
Putman, C.M.2
Alley, M.T.3
-
45
-
-
0032879733
-
Intrahospital transport of critically ill patients
-
Waydhas C. Intrahospital transport of critically ill patients. Crit Care 1999;3:R83-89
-
(1999)
Crit Care
, vol.3
-
-
Waydhas, C.1
-
46
-
-
84875053402
-
Errors in the estimation of wall shear stress by maximum Doppler velocity
-
Mynard JP, Wasserman BA, Steinman DA. Errors in the estimation of wall shear stress by maximum Doppler velocity. Atherosclerosis 2013;227:259-66
-
(2013)
Atherosclerosis
, vol.227
, pp. 259-266
-
-
Mynard, J.P.1
Wasserman, B.A.2
Steinman, D.A.3
|