메뉴 건너뛰기




Volumn 39, Issue 2, 2011, Pages 850-863

Intracranial stents being modeled as a porous medium: Flow simulation in stented cerebral aneurysms

Author keywords

Cerebral aneurysm; Computational fluid dynamics; Flow simulation; Intracranial stent; Porous medium

Indexed keywords

CEREBRAL ANEURYSMS; COMPLEX NATURE; COMPUTATIONAL FLUID; COMPUTATIONAL TIME; DATA SETS; ENDOVASCULAR DEVICES; FLOW DIVERTER; FLOW MODEL; FLOW REDUCTION; INTRACRANIAL ANEURYSMS; INTRACRANIAL STENT; ISO-VELOCITY SURFACES; MAIN EFFECT; NUMERICAL SIMULATION; PHYSIOLOGICAL FLOW; POROUS MEDIUM; POROUS MEDIUM APPROACH; ROOT MEAN SQUARED ERRORS; SHEAR RATES; STENT GEOMETRY; WALL SHEAR STRESS;

EID: 79951555876     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/s10439-010-0200-6     Document Type: Article
Times cited : (101)

References (33)
  • 2
    • 36349011925 scopus 로고    scopus 로고
    • Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device
    • DOI 10.1007/s00234-007-0281-6
    • F Ahlhelm, et al. 2007 Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device Neuroradiology 49 12 1023 1028 10.1007/s00234-007-0281-6 17703295 (Pubitemid 350159840)
    • (2007) Neuroradiology , vol.49 , Issue.12 , pp. 1023-1028
    • Ahlhelm, F.1    Roth, C.2    Kaufmann, R.3    Schulte-Altedorneburg, G.4    Romeike, B.F.M.5    Reith, W.6
  • 4
    • 0035183970 scopus 로고    scopus 로고
    • Treatment of a ruptured dissecting vertebral artery aneurysm with double stent placement: Case report
    • G Benndorf, et al. 2001 Treatment of a ruptured dissecting vertebral artery aneurysm with double stent placement: case report AJNR Am. J. Neuroradiol. 22 10 1844 1848 1:STN:280:DC%2BD3Mnos1yhsw%3D%3D 11733313 (Pubitemid 33091950)
    • (2001) American Journal of Neuroradiology , vol.22 , Issue.10 , pp. 1844-1848
    • Benndorf, G.1    Herbon, U.2    Sollmann, W.P.3    Campi, A.4
  • 5
    • 0030055718 scopus 로고    scopus 로고
    • Identification of quantifiable hemodynamic factors in the assessment of cerebral aneurysm behavior: On behalf of the subcommittee on biorheology of the scientific and standardization committee of the ISTH
    • AC Burleson VT Turitto 1996 Identification of quantifiable hemodynamic factors in the assessment of cerebral aneurysm behavior. On behalf of the Subcommittee on Biorheology of the Scientific and Standardization Committee of the ISTH Thromb. Haemost. 76 1 118 123 1:CAS:528:DyaK28Xktl2gtbk%3D 8819263 (Pubitemid 26254328)
    • (1996) Thrombosis and Haemostasis , vol.76 , Issue.1 , pp. 118-123
    • Burleson, A.C.1    Turitto, V.T.2
  • 7
    • 17444420835 scopus 로고    scopus 로고
    • Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique
    • DOI 10.1109/TMI.2005.844172, Vascular Imaging
    • JR Cebral R Lohner 2005 Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique IEEE Trans. Med. Imaging 24 4 468 476 10.1109/TMI.2005.844172 15822805 (Pubitemid 40538204)
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.4 , pp. 468-476
    • Cebral, J.R.1    Lohner, R.2
  • 9
    • 38549172191 scopus 로고    scopus 로고
    • Modeling the interaction of coils with the local blood flow after coil embolization of intracranial aneurysms
    • DOI 10.1115/1.2800773
    • KS Cha, et al. 2007 Modeling the interaction of coils with the local blood flow after coil embolization of intracranial aneurysms J. Biomech. Eng. 129 6 873 879 10.1115/1.2800773 18067391 (Pubitemid 351153475)
    • (2007) Journal of Biomechanical Engineering , vol.129 , Issue.6 , pp. 873-879
    • Kyung, S.C.1    Balaras, E.2    Lieber, B.B.3    Sadasivan, C.4    Wakhloo, A.K.5
  • 10
    • 55049093969 scopus 로고    scopus 로고
    • Numerical simulation of blood flows through a porous interface
    • 10.1051/m2an:2008031
    • MA Fernandez J-F Gerbeau V Martin 2008 Numerical simulation of blood flows through a porous interface ESAIM: Math. Model. Numer. Anal. 42 2008 961 990 10.1051/m2an:2008031
    • (2008) ESAIM: Math. Model. Numer. Anal. , vol.42 , Issue.2008 , pp. 961-990
    • Fernandez, M.A.1    Gerbeau, J.-F.2    Martin, V.3
  • 13
    • 44449176037 scopus 로고    scopus 로고
    • The haemodynamics of endovascular aneurysm treatment: A computational modelling approach for estimating the influence of multiple coil deployment
    • DOI 10.1109/TMI.2008.915549, 4531637
    • NM Kakalis, et al. 2008 The haemodynamics of endovascular aneurysm treatment: a computational modelling approach for estimating the influence of multiple coil deployment IEEE Trans. Med. Imaging 27 6 814 824 10.1109/TMI.2008.915549 18541488 (Pubitemid 351760853)
    • (2008) IEEE Transactions on Medical Imaging , vol.27 , Issue.6 , pp. 814-824
    • Kakalis, N.M.P.1    Mitsos, A.P.2    Byrne, J.V.3    Ventikos, Y.4
  • 14
    • 34548250908 scopus 로고    scopus 로고
    • A new endoluminal, flow-disrupting device for treatment of saccular aneurysms
    • DOI 10.1161/STROKEAHA.106.479576, PII 0000767020070800000037
    • DF Kallmes, et al. 2007 A new endoluminal, flow-disrupting device for treatment of saccular aneurysms Stroke 38 8 2346 2352 10.1161/STROKEAHA.106. 479576 17615366 (Pubitemid 47457579)
    • (2007) Stroke , vol.38 , Issue.8 , pp. 2346-2352
    • Kallmes, D.F.1    Ding, Y.H.2    Dai, D.3    Kadirvel, R.4    Lewis, D.A.5    Cloft, H.J.6
  • 15
    • 70249089760 scopus 로고    scopus 로고
    • Endovascular treatment by using double stent method for ruptured vertebral artery dissecting aneurysms
    • SH Kim, et al. 2005 Endovascular treatment by using double stent method for ruptured vertebral artery dissecting aneurysms J. Korean Neurosurg. Soc. 38 132 135
    • (2005) J. Korean Neurosurg. Soc. , vol.38 , pp. 132-135
    • Kim, S.H.1
  • 16
    • 37649009628 scopus 로고    scopus 로고
    • Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar trunk aneurysm
    • 10.1227/01.neu.0000306110.55174.30 18162911 discussion 1312-1313
    • M Kim, et al. 2007 Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar trunk aneurysm Neurosurgery 61 6 1305 1312 10.1227/01.neu.0000306110.55174.30 18162911 discussion 1312-1313
    • (2007) Neurosurgery , vol.61 , Issue.6 , pp. 1305-1312
    • Kim, M.1
  • 17
    • 43249124900 scopus 로고    scopus 로고
    • Comparison of two stents in modifying cerebral aneurysm hemodynamics
    • 10.1007/s10439-008-9449-4 18264766
    • M Kim, et al. 2008 Comparison of two stents in modifying cerebral aneurysm hemodynamics Ann. Biomed. Eng. 36 5 726 741 10.1007/s10439-008-9449-4 18264766
    • (2008) Ann. Biomed. Eng. , vol.36 , Issue.5 , pp. 726-741
    • Kim, M.1
  • 18
    • 0031148733 scopus 로고    scopus 로고
    • Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity
    • 1:STN:280:DyaK2s3pt1alsw%3D%3D 10.1007/BF02684187 9146801
    • BB Lieber AP Stancampiano AK Wakhloo 1997 Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity Ann. Biomed. Eng. 25 3 460 469 1:STN:280:DyaK2s3pt1alsw%3D%3D 10.1007/BF02684187 9146801
    • (1997) Ann. Biomed. Eng. , vol.25 , Issue.3 , pp. 460-469
    • Lieber, B.B.1    Stancampiano, A.P.2    Wakhloo, A.K.3
  • 20
    • 34249823676 scopus 로고    scopus 로고
    • Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation
    • DOI 10.1161/STROKEAHA.106.481234, PII 0000767020070600000054
    • H Meng, et al. 2007 Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation Stroke 38 6 1924 1931 10.1161/STROKEAHA.106.481234 17495215 (Pubitemid 46847270)
    • (2007) Stroke , vol.38 , Issue.6 , pp. 1924-1931
    • Meng, H.1    Wang, Z.2    Hoi, Y.3    Gao, L.4    Metaxa, E.5    Swartz, D.D.6    Kolega, J.7
  • 21
    • 41149156492 scopus 로고    scopus 로고
    • Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: Technical note
    • 10.1007/s00234-007-0334-x 18043912
    • AP Mitsos, et al. 2008 Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: technical note Neuroradiology 50 4 341 347 10.1007/s00234-007-0334-x 18043912
    • (2008) Neuroradiology , vol.50 , Issue.4 , pp. 341-347
    • Mitsos, A.P.1
  • 22
    • 0037180253 scopus 로고    scopus 로고
    • International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomised trial
    • DOI 10.1016/S0140-6736(02)11314-6
    • A Molyneux, et al. 2002 International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial Lancet 360 9342 1267 1274 10.1016/S0140-6736(02)11314-6 12414200 (Pubitemid 35284616)
    • (2002) Lancet , vol.360 , Issue.9342 , pp. 1267-1274
    • Molyneux, A.1    Kerr, R.2    Stratton, I.3    Sandercock, P.4    Clarke, M.5    Shrimpton, J.6    Holman, R.7
  • 23
    • 34250624459 scopus 로고    scopus 로고
    • Comparison of ruptured vs unruptured aneurysms in recanalization after coil embolization
    • DOI 10.1016/j.surneu.2006.10.021, PII S0090301906009670
    • TN Nguyen, et al. 2007 Comparison of ruptured vs unruptured aneurysms in recanalization after coil embolization Surg. Neurol. 68 1 19 23 10.1016/j.surneu.2006.10.021 17586214 (Pubitemid 46935298)
    • (2007) Surgical Neurology , vol.68 , Issue.1 , pp. 19-23
    • Nguyen, T.N.1    Hoh, B.L.2    Amin-Hanjani, S.3    Pryor, J.C.4    Ogilvy, C.S.5
  • 24
    • 52649181707 scopus 로고    scopus 로고
    • Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model - A report on the Virtual Intracranial Stenting Challenge 2007
    • 1:STN:280:DC%2BD1cvks12ntQ%3D%3D 10.1016/j.jbiomech.2008.04.035 18582891
    • AG Radaelli, et al. 2008 Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model-a report on the Virtual Intracranial Stenting Challenge 2007 J Biomech 41 10 2069 2081 1:STN:280: DC%2BD1cvks12ntQ%3D%3D 10.1016/j.jbiomech.2008.04.035 18582891
    • (2008) J Biomech , vol.41 , Issue.10 , pp. 2069-2081
    • Radaelli, A.G.1
  • 25
    • 67650073170 scopus 로고    scopus 로고
    • Validation of a one-dimensional model of the systemic arterial tree
    • 1:CAS:528:DC%2BD1MXovVKitrg%3D 10.1152/ajpheart.00037.2009 19429832
    • P Reymond, et al. 2009 Validation of a one-dimensional model of the systemic arterial tree Am. J. Physiol. Heart Circ. Physiol. 297 1 H208 H222 1:CAS:528:DC%2BD1MXovVKitrg%3D 10.1152/ajpheart.00037.2009 19429832
    • (2009) Am. J. Physiol. Heart Circ. Physiol. , vol.297 , Issue.1
    • Reymond, P.1
  • 26
    • 67649524991 scopus 로고    scopus 로고
    • Treatment of rabbit elastase-induced aneurysm models by flow diverters: Development of quantifiable indexes of device performance using digital subtraction angiography
    • 10.1109/TMI.2008.2012162 19164085
    • C Sadasivan, et al. 2009 Treatment of rabbit elastase-induced aneurysm models by flow diverters: development of quantifiable indexes of device performance using digital subtraction angiography IEEE Trans. Med. Imaging 28 7 1117 1125 10.1109/TMI.2008.2012162 19164085
    • (2009) IEEE Trans. Med. Imaging , vol.28 , Issue.7 , pp. 1117-1125
    • Sadasivan, C.1
  • 30
    • 67651163903 scopus 로고    scopus 로고
    • Molecular alterations associated with aneurysmal remodeling are localized in the high hemodynamic stress region of a created carotid bifurcation
    • 10.1227/01.NEU.0000343541.85713.01 19574839 discussion 177-178
    • Z Wang, et al. 2009 Molecular alterations associated with aneurysmal remodeling are localized in the high hemodynamic stress region of a created carotid bifurcation Neurosurgery 65 1 169 177 10.1227/01.NEU.0000343541.85713.01 19574839 discussion 177-178
    • (2009) Neurosurgery , vol.65 , Issue.1 , pp. 169-177
    • Wang, Z.1
  • 31
    • 0031783384 scopus 로고    scopus 로고
    • Cigarette smoking as a cause of aneurysmal subarachnoid hemorrhage and risk for vasospasm: A report of the Cooperative Aneurysm Study
    • BK Weir, et al. 1998 Cigarette smoking as a cause of aneurysmal subarachnoid hemorrhage and risk for vasospasm: a report of the Cooperative Aneurysm Study J. Neurosurg. 89 3 405 411 1:STN:280:DyaK1czovFGjtQ%3D%3D 10.3171/jns.1998.89.3.0405 9724114 (Pubitemid 28405254)
    • (1998) Journal of Neurosurgery , vol.89 , Issue.3 , pp. 405-411
    • Weir, B.K.A.1    Kongable, G.L.2    Kassell, N.F.3    Schultz, J.R.4    Truskowski, L.L.5    Sigrest, A.6
  • 32
    • 0038304776 scopus 로고    scopus 로고
    • Unruptured intracranial aneurysms: Natural history, clinical outcome, and risks of surgical and endovascular treatment
    • DOI 10.1016/S0140-6736(03)13860-3
    • DO Wiebers, et al. 2003 Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment Lancet 362 9378 103 110 10.1016/S0140-6736(03)13860-3 12867109 (Pubitemid 36831019)
    • (2003) Lancet , vol.362 , Issue.9378 , pp. 103-110
    • Wiebers, D.O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.