메뉴 건너뛰기




Volumn 42, Issue 1, 2014, Pages 73-78

Optimal design of an individual endoprosthesis for the reconstruction of extensive mandibular defects with finite element analysis

Author keywords

Finite element analysis; Individual endoprosthesis; Mandibular reconstruction; Optimal design

Indexed keywords

TITANIUM;

EID: 84890857753     PISSN: 10105182     EISSN: 18784119     Source Type: Journal    
DOI: 10.1016/j.jcms.2013.02.005     Document Type: Article
Times cited : (45)

References (27)
  • 2
    • 33845506823 scopus 로고    scopus 로고
    • Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. I. Mathematical validation and experimental verification
    • J. Al-Sukhun, J. Kelleway, and M. Helenius Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. I. Mathematical validation and experimental verification J Biomed Mater Res A Jan 80 2007 234 246
    • (2007) J Biomed Mater Res A Jan , vol.80 , pp. 234-246
    • Al-Sukhun, J.1    Kelleway, J.2    Helenius, M.3
  • 3
    • 0037645044 scopus 로고    scopus 로고
    • Creation of a three-dimensional model of the mandible and the TMJ in vivo by means of the finite element method
    • M.C. Castaño, U. Zapata, A. Pedroza, J.D. Jaramillo, and S. Roldán Creation of a three-dimensional model of the mandible and the TMJ in vivo by means of the finite element method Int J Comput Dent 5 2002 87 99
    • (2002) Int J Comput Dent , vol.5 , pp. 87-99
    • Castaño, M.C.1    Zapata, U.2    Pedroza, A.3    Jaramillo, J.D.4    Roldán, S.5
  • 4
    • 20344408045 scopus 로고    scopus 로고
    • Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis. Part 1: Advancement surgery-posterior loading
    • E. Erkmen, B. Simşek, E. Yücel, and A. Kurt Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis. Part 1: advancement surgery-posterior loading Int J Oral Maxillofac Surg 34 2005 551 558
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 551-558
    • Erkmen, E.1    Simşek, B.2    Yücel, E.3    Kurt, A.4
  • 5
    • 77952581091 scopus 로고    scopus 로고
    • Feasibility of alloplastic mandibular reconstruction in patients following removal of oral squamous cell carcinoma
    • T. Ettl, O. Driemel, B.V. Dresp, T.E. Reichert, J. Reuther, and H. Pistner Feasibility of alloplastic mandibular reconstruction in patients following removal of oral squamous cell carcinoma J Craniomaxillofac Surg 38 2010 350 354
    • (2010) J Craniomaxillofac Surg , vol.38 , pp. 350-354
    • Ettl, T.1    Driemel, O.2    Dresp, B.V.3    Reichert, T.E.4    Reuther, J.5    Pistner, H.6
  • 6
    • 57849108082 scopus 로고    scopus 로고
    • In vitro technique in estimation of passive mechanical properties of bovine heart part II. Constitutive relation and finite element analysis
    • H. Ghaemi, K. Behdinan, and A.D. Spence In vitro technique in estimation of passive mechanical properties of bovine heart part II. Constitutive relation and finite element analysis Med Eng Phys 31 2009 83 91
    • (2009) Med Eng Phys , vol.31 , pp. 83-91
    • Ghaemi, H.1    Behdinan, K.2    Spence, A.D.3
  • 7
    • 0043287747 scopus 로고    scopus 로고
    • Microvascular flap reconstruction of the mandible: A comparison of bone grafts and bridging plates for restoration of mandibular continuity
    • C. Head, D. Alam, J.A. Sercarz, J.T. Lee, J.D. Rawnsley, and G.S. Berke et al. Microvascular flap reconstruction of the mandible: a comparison of bone grafts and bridging plates for restoration of mandibular continuity Otolaryngol Head Neck Surg 129 2003 48 54
    • (2003) Otolaryngol Head Neck Surg , vol.129 , pp. 48-54
    • Head, C.1    Alam, D.2    Sercarz, J.A.3    Lee, J.T.4    Rawnsley, J.D.5    Berke, G.S.6
  • 8
    • 77954684970 scopus 로고    scopus 로고
    • A comparison of simulated jaw dynamics in models of segmental mandibular resection versus resection with alloplastic reconstruction
    • A.G. Hannam, I.K. Stavness, J.E. Lloyd, S.S. Fels, A.J. Miller, and D.A. Curtis A comparison of simulated jaw dynamics in models of segmental mandibular resection versus resection with alloplastic reconstruction J Prosthet Dent 104 2010 191 198
    • (2010) J Prosthet Dent , vol.104 , pp. 191-198
    • Hannam, A.G.1    Stavness, I.K.2    Lloyd, J.E.3    Fels, S.S.4    Miller, A.J.5    Curtis, D.A.6
  • 9
    • 16544379279 scopus 로고    scopus 로고
    • Stress tests of reconstruction plates for bridging mandibular angle defects
    • W.D. Knoll, A. Gaida, and P. Maurer Stress tests of reconstruction plates for bridging mandibular angle defects Mund Kiefer Gesichtchir 8 2004 237 243
    • (2004) Mund Kiefer Gesichtchir , vol.8 , pp. 237-243
    • Knoll, W.D.1    Gaida, A.2    Maurer, P.3
  • 11
    • 34249087173 scopus 로고    scopus 로고
    • Evaluation of different miniplates in fixation of fractured human mandible with the finite element method
    • H.H. Korkmaz Evaluation of different miniplates in fixation of fractured human mandible with the finite element method Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103 2007 e1 13
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.103 , pp. 1-13
    • Korkmaz, H.H.1
  • 12
    • 77749285705 scopus 로고    scopus 로고
    • Finite Element Analysis of a TMJ Implant
    • A. Kashi, A.R. Chowdhury, and S. Saha Finite Element Analysis of a TMJ Implant J Dental Res 89 2010 241 245
    • (2010) J Dental Res , vol.89 , pp. 241-245
    • Kashi, A.1    Chowdhury, A.R.2    Saha, S.3
  • 13
    • 58149289692 scopus 로고    scopus 로고
    • Modular endoprosthesis for mandibular reconstruction: A clinical, micro-CT and histologic evaluation in 8 Macaca fascicularis
    • S. Lee, B.T. Goh, H. Tideman, P.J. Stoelinga, and J.A. Jansen Modular endoprosthesis for mandibular reconstruction: a clinical, micro-CT and histologic evaluation in 8 Macaca fascicularis Int J Oral Maxillofac Surg 38 2009 40 47
    • (2009) Int J Oral Maxillofac Surg , vol.38 , pp. 40-47
    • Lee, S.1    Goh, B.T.2    Tideman, H.3    Stoelinga, P.J.4    Jansen, J.A.5
  • 14
    • 84867862586 scopus 로고    scopus 로고
    • Preliminary application of virtual simulation and reposition template for zygomatico-orbitomaxillary complex fracture
    • P. Li, W. Tang, J. Li, and W.D. Tian Preliminary application of virtual simulation and reposition template for zygomatico-orbitomaxillary complex fracture J Craniofac Surg 23 2012 1436 1439
    • (2012) J Craniofac Surg , vol.23 , pp. 1436-1439
    • Li, P.1    Tang, W.2    Li, J.3    Tian, W.D.4
  • 15
    • 84880113449 scopus 로고    scopus 로고
    • Stress distribution on the mandibular condyle and the distraction area in distraction osteogenesis by finite element analysis
    • Corrected Proof
    • Li P, Tang W, Li J, Liang R, Tian WD, Long J: Stress distribution on the mandibular condyle and the distraction area in distraction osteogenesis by finite element analysis. J Craniofac Surg. 24:Corrected Proof. 2013
    • (2013) J Craniofac Surg , vol.24
    • Li, P.1    Tang, W.2    Li, J.3    Liang, R.4    Tian, W.D.5    Long, J.6
  • 16
    • 0033067941 scopus 로고    scopus 로고
    • Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement
    • C.E. Misch, Z. Qu, and M.W. Bidez Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement J Oral Maxillofac Surg 57 1999 706 708
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 706-708
    • Misch, C.E.1    Qu, Z.2    Bidez, M.W.3
  • 17
    • 33645891156 scopus 로고    scopus 로고
    • Experimental evaluation of three osteosynthesis devices used for stabilizing condylar fractures of the mandible
    • C. Meyer, L. Serhir, and P. Boutemi Experimental evaluation of three osteosynthesis devices used for stabilizing condylar fractures of the mandible J Craniomaxillofac Surg 34 2006 173 181
    • (2006) J Craniomaxillofac Surg , vol.34 , pp. 173-181
    • Meyer, C.1    Serhir, L.2    Boutemi, P.3
  • 18
    • 31144472698 scopus 로고    scopus 로고
    • Computer assisted chewing power in patients with segmental resection of the mandible
    • P. Maurer, H. Pistner, and J. Schubert Computer assisted chewing power in patients with segmental resection of the mandible Mund Kiefer Gesichtschir 10 2006 37 41
    • (2006) Mund Kiefer Gesichtschir , vol.10 , pp. 37-41
    • Maurer, P.1    Pistner, H.2    Schubert, J.3
  • 19
    • 79958773009 scopus 로고    scopus 로고
    • Straight, semi-anatomic and anatomic TMJ implants: The influence of condylar geometry and bone fixation screws
    • A. Ramos, A. Completo, C. Relvas, M. Mesnard, and J.A. Simões Straight, semi-anatomic and anatomic TMJ implants: the influence of condylar geometry and bone fixation screws J Craniomaxillofac Surg 39 2011 343 350
    • (2011) J Craniomaxillofac Surg , vol.39 , pp. 343-350
    • Ramos, A.1    Completo, A.2    Relvas, C.3    Mesnard, M.4    Simões, J.A.5
  • 20
    • 34247165745 scopus 로고    scopus 로고
    • Biomechanical testing of different osteosynthesis systems for segmental resection of the mandible
    • W. Schupp, M. Arzdorf, B. Linke, and R. Gutwald Biomechanical testing of different osteosynthesis systems for segmental resection of the mandible J Oral Maxillofac Surg 65 2007 924 930
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 924-930
    • Schupp, W.1    Arzdorf, M.2    Linke, B.3    Gutwald, R.4
  • 21
    • 79551666486 scopus 로고    scopus 로고
    • Sensitivity analysis of a validated subject-specific finite element model of the human craniofacial skeleton
    • T.D. Szwedowski, J. Fialkov, and C.M. Whyne Sensitivity analysis of a validated subject-specific finite element model of the human craniofacial skeleton Proc Inst Mech Eng H 225 2011 58 67
    • (2011) Proc Inst Mech Eng H , vol.225 , pp. 58-67
    • Szwedowski, T.D.1    Fialkov, J.2    Whyne, C.M.3
  • 22
    • 84869495732 scopus 로고    scopus 로고
    • A computational method for determining tissue material properties in ovine fracture calluses using electronic speckle pattern interferometry and finite element analysis
    • M. Steiner, L. Claes, U. Simon, A. Ignatius, and T. Wehner A computational method for determining tissue material properties in ovine fracture calluses using electronic speckle pattern interferometry and finite element analysis Med Eng Phys 34 2012 1521 1525
    • (2012) Med Eng Phys , vol.34 , pp. 1521-1525
    • Steiner, M.1    Claes, L.2    Simon, U.3    Ignatius, A.4    Wehner, T.5
  • 23
    • 67650127562 scopus 로고    scopus 로고
    • Condyle replacement after tumor resection: Comparison of individual prefabricated titanium implants and costochondral grafts
    • W. Tang, J. Long, F. Feng, L. Guo, C. Gao, and W. Tian Condyle replacement after tumor resection: comparison of individual prefabricated titanium implants and costochondral grafts Oral Surg Oral Med Oral Pathol Oral Radiol Endod 108 2009 147 152
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.108 , pp. 147-152
    • Tang, W.1    Long, J.2    Feng, F.3    Guo, L.4    Gao, C.5    Tian, W.6
  • 24
  • 25
    • 79954423410 scopus 로고    scopus 로고
    • Review of biomechanical models used in studying the biomechanics of reconstructed mandibles
    • R.C. Wong, H. Tideman, M.A. Merkx, J. Jansen, S.M. Goh, and K. Liao Review of biomechanical models used in studying the biomechanics of reconstructed mandibles Int J Oral Maxillofac Surg 40 2011 393 400
    • (2011) Int J Oral Maxillofac Surg , vol.40 , pp. 393-400
    • Wong, R.C.1    Tideman, H.2    Merkx, M.A.3    Jansen, J.4    Goh, S.M.5    Liao, K.6
  • 26
    • 84869496207 scopus 로고    scopus 로고
    • The modular endoprosthesis for mandibular body replacement. Part 2: Finite element analysis of endoprosthesis reconstruction of the mandible
    • R.C. Wong, H. Tideman, M.A. Merkx, J. Jansen, and S.M. Goh The modular endoprosthesis for mandibular body replacement. Part 2: Finite element analysis of endoprosthesis reconstruction of the mandible J Craniomaxillofac Surg 40 2012 e487 e497
    • (2012) J Craniomaxillofac Surg , vol.40
    • Wong, R.C.1    Tideman, H.2    Merkx, M.A.3    Jansen, J.4    Goh, S.M.5
  • 27
    • 0033250012 scopus 로고    scopus 로고
    • Reconstruction plates to bridge mandibular defects: A clinical and experimental investigation in biomechanical aspects
    • Y. Zhang, J.G. Zhang, G.Y. Yu, L. Liu, F.Y. Zhao, and G.C. Zhong Reconstruction plates to bridge mandibular defects: a clinical and experimental investigation in biomechanical aspects Int J Oral Maxillofac Surg 28 1999 445 450
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 445-450
    • Zhang, Y.1    Zhang, J.G.2    Yu, G.Y.3    Liu, L.4    Zhao, F.Y.5    Zhong, G.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.