메뉴 건너뛰기




Volumn 225, Issue 1, 2011, Pages 58-67

Sensitivity analysis of a validated subject-specific finite element model of the human craniofacial skeleton

Author keywords

computed tomography; experimental validation; human craniofacial skeleton; sensitivity analysis; subject specific finite element model

Indexed keywords

BONY STRUCTURES; COMPLEX STRUCTURE; COMPUTATIONAL MODEL; COMPUTED TOMOGRAPHY; COMPUTED TOMOGRAPHY DATA; CORTICAL BONE; CORTICAL THICKNESS; CRANIOFACIAL; CRANIOFACIAL SKELETON; EXPERIMENTAL DATA; EXPERIMENTAL VALIDATION; FE MODEL; HUMAN CRANIOFACIAL SKELETON; LOCAL LOADS; MECHANICAL RESPONSE; PARAMETRIC CHANGES; PHYSIOLOGIC LOADINGS; PHYSIOLOGICAL LOADS; SPECIFIC FINITE ELEMENT; STRAIN PATTERNS; STRUCTURAL BEHAVIOUR; SUBJECT-SPECIFIC; SUBJECT-SPECIFIC FINITE ELEMENT MODEL; TEMPORALIS; TRAUMATIC INJURY;

EID: 79551666486     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM786     Document Type: Article
Times cited : (24)

References (32)
  • 2
    • 0026668801 scopus 로고
    • The fate of plates and screws after facial fracture reconstruction
    • October
    • Francel, T. J., Birely, B. C., Ringelman, P. R., and Manson, P. N. The fate of plates and screws after facial fracture reconstruction. Plast. Reconstr. Surg., October 1992, 90, 568-573.
    • (1992) Plast. Reconstr. Surg. , vol.90 , pp. 568-573
    • Francel, T.J.1    Birely, B.C.2    Ringelman, P.R.3    Manson, P.N.4
  • 3
    • 0036244581 scopus 로고    scopus 로고
    • The efficacy of resorbable plates in head and neck reconstruction
    • May
    • Bhanot, S., Alex, J. C., Lowlicht, R. A., Ross, D. A., and Sasaki, C. T. The efficacy of resorbable plates in head and neck reconstruction. Laryngoscope, May 2002, 112, 890-898.
    • (2002) Laryngoscope , vol.112 , pp. 890-898
    • Bhanot, S.1    Alex, J.C.2    Lowlicht, R.A.3    Ross, D.A.4    Sasaki, C.T.5
  • 4
    • 0031965403 scopus 로고    scopus 로고
    • Reasons for removal of rigid internal fixation devices in craniofacial surgery
    • January
    • Orringer, J. S., Barcelona, V., and Buchman, S. R. Reasons for removal of rigid internal fixation devices in craniofacial surgery. J. Craniofac. Surg., January 1998, 9, 40-44.
    • (1998) J. Craniofac. Surg. , vol.9 , pp. 40-44
    • Orringer, J.S.1    Barcelona, V.2    Buchman, S.R.3
  • 5
    • 79551660674 scopus 로고    scopus 로고
    • 6 February available from
    • Barrera, J. E. and Batuello, S. G. Fractures, mandible, angle. 6 February 2006, 7(6), 1, available from http:// emedicine.medscape.com/article/868517- overview
    • (2006) Fractures, Mandible, Angle , vol.7 , Issue.6 , pp. 1
    • Barrera, J.E.1    Batuello, S.G.2
  • 6
    • 0009623350 scopus 로고    scopus 로고
    • Strategies for bone subsititutes in craniofacial surgery
    • edition 1 (Ed. J. E. Davies) Em Squared Inc., Toronto)
    • Fialkov, J. A., Holy, C. E., and Antonyshyn, O. O. Strategies for bone subsititutes in craniofacial surgery. In Bone engineering, edition 1 (Ed. J. E. Davies), 2000, pp. 548-556 (Em Squared Inc., Toronto).
    • (2000) Bone Engineering , pp. 548-556
    • Fialkov, J.A.1    Holy, C.E.2    Antonyshyn, O.O.3
  • 7
    • 29244442292 scopus 로고    scopus 로고
    • Symptomatic plate removal in maxillofacial trauma: A review of 76 cases
    • December
    • Murthy, A. S. and Lehman Jr, J. A. Symptomatic plate removal in maxillofacial trauma: a review of 76 cases. Ann. Plast. Surg., December 2005, 55, 603-607.
    • (2005) Ann. Plast. Surg. , vol.55 , pp. 603-607
    • Murthy, A.S.1    Lehman Jr., J.A.2
  • 11
    • 29244464692 scopus 로고    scopus 로고
    • Plate removal in traumatic facial fractures: 13-year practice review
    • December
    • Nagase, D. Y., Courtemanche, D. J., and Peters, D. A. Plate removal in traumatic facial fractures: 13-year practice review. Ann. Plast. Surg., December 2005, 55, 608-611.
    • (2005) Ann. Plast. Surg. , vol.55 , pp. 608-611
    • Nagase, D.Y.1    Courtemanche, D.J.2    Peters, D.A.3
  • 12
    • 0032992572 scopus 로고    scopus 로고
    • Complications of internal fixation of maxillofacial fractures with microplates
    • February Discussion 135
    • Schortinghuis, J., Bos, R. R., and Vissink, A. Complications of internal fixation of maxillofacial fractures with microplates. J. Oral Maxillofac. Surg., February 1999, 57, 130-4. Discussion 135.
    • (1999) J. Oral Maxillofac. Surg. , vol.57 , pp. 130-4
    • Schortinghuis, J.1    Bos, R.R.2    Vissink, A.3
  • 13
    • 0030513058 scopus 로고    scopus 로고
    • Strain gauge analysis of the frontozygomatic region of the zygomatic complex
    • September Discussion 1095-6
    • Oyen, O. J., Melugin, M. B., and Indresano, A. T. Strain gauge analysis of the frontozygomatic region of the zygomatic complex. J. Oral Maxillofac. Surg., September 1996, 54, 1092-1095. Discussion 1095-6.
    • (1996) J. Oral Maxillofac. Surg. , vol.54 , pp. 1092-1095
    • Oyen, O.J.1    Melugin, M.B.2    Indresano, A.T.3
  • 15
    • 0026599486 scopus 로고
    • Biomechanics of the facial skeleton
    • January
    • Rudderman, R. H. and Mullen, R. L. Biomechanics of the facial skeleton. Clin. Plast. Surg., January 1992, 19, 11-29.
    • (1992) Clin. Plast. Surg. , Issue.19 , pp. 11-29
    • Rudderman, R.H.1    Mullen, R.L.2
  • 16
    • 21144455864 scopus 로고    scopus 로고
    • Subject-specific finite element model of the pelvis: Development, validation and sensitivity studies
    • June
    • Anderson, A. E., Peters, C. L., Tuttle, B. D., and Weiss, J. A. Subject-specific finite element model of the pelvis: development, validation and sensitivity studies. J. Biomech. Engng, June 2005, 127, 364-373.
    • (2005) J. Biomech. Engng , vol.127 , pp. 364-373
    • Anderson, A.E.1    Peters, C.L.2    Tuttle, B.D.3    Weiss, J.A.4
  • 17
    • 0027703730 scopus 로고
    • Validation of an automated method of three-dimensional finite element modelling of bone
    • November
    • Keyak, J. H., Fourkas, M. G., Meagher, J. M., and Skinner, H. B. Validation of an automated method of three-dimensional finite element modelling of bone. J. Biomed. Engng, November 1993, 15, 505-509.
    • (1993) J. Biomed. Engng , vol.15 , pp. 505-509
    • Keyak, J.H.1    Fourkas, M.G.2    Meagher, J.M.3    Skinner, H.B.4
  • 18
    • 0029347550 scopus 로고
    • Development and validation of a three-dimensional finite element model of the pelvic bone
    • August
    • Dalstra, M., Huiskes, R., and van Erning, L. Development and validation of a three-dimensional finite element model of the pelvic bone. J. Biomech. Engng, August 1995, 117, 272-278.
    • (1995) J. Biomech. Engng , vol.117 , pp. 272-278
    • Dalstra, M.1    Huiskes, R.2    Van Erning, L.3
  • 19
    • 22044432465 scopus 로고    scopus 로고
    • A 3D finite element model of an implanted scapula: Importance of a multiparametric validation using experimental data
    • September
    • Maurel, N., Diop, A., and Grimberg, J. A 3D finite element model of an implanted scapula: importance of a multiparametric validation using experimental data. J. Biomechanics, September 2005, 38, 1865-1872.
    • (2005) J. Biomechanics , vol.38 , pp. 1865-1872
    • Maurel, N.1    Diop, A.2    Grimberg, J.3
  • 21
    • 0037382942 scopus 로고    scopus 로고
    • Burst fracture in the metastatically involved spine: Development, validation, and parametric analysis of a three-dimensional poroelastic finite-element model
    • Whyne, C. M., Hu, S. S., and Lotz, J. C. Burst fracture in the metastatically involved spine: development, validation, and parametric analysis of a three-dimensional poroelastic finite-element model. Spine, 2003, 28, 652-660.
    • (2003) Spine , Issue.28 , pp. 652-660
    • Whyne, C.M.1    Hu, S.S.2    Lotz, J.C.3
  • 22
    • 16844363499 scopus 로고    scopus 로고
    • The dynamic role of buttress reconstruction after maxillectomy
    • April Discussion 1341
    • Nagasao, T., Nakajima, T., Kimura, A., Kaneko, T., Jin, H., and Tamaki, T. The dynamic role of buttress reconstruction after maxillectomy. Plast. Reconstr. Surg., April 2005, 115, 1328-1340. Discussion 1341.
    • (2005) Plast. Reconstr. Surg. , vol.115 , pp. 1328-1340
    • Nagasao, T.1    Nakajima, T.2    Kimura, A.3    Kaneko, T.4    Jin, H.5    Tamaki, T.6
  • 23
    • 0024017384 scopus 로고
    • Three-dimensional model of the human craniofacial skeleton: Method and preliminary results using finite element analysis
    • May
    • Tanne, K., Miyasaka, J., Yamagata, Y., Sachdeva, R., Tsutsumi, S., and Sakuda, M. Three-dimensional model of the human craniofacial skeleton: method and preliminary results using finite element analysis. J. Biomed. Engng, May 1988, 10, 246-252.
    • (1988) J. Biomed. Engng , vol.10 , pp. 246-252
    • Tanne, K.1    Miyasaka, J.2    Yamagata, Y.3    Sachdeva, R.4    Tsutsumi, S.5    Sakuda, M.6
  • 24
    • 0035408228 scopus 로고    scopus 로고
    • Three-dimensional finite element analysis of the facial skeleton on simulated occlusal loading
    • July
    • Gross, M. D., Arbel, G., and Hershkovitz, I. Three-dimensional finite element analysis of the facial skeleton on simulated occlusal loading. J. Oral Rehabil., July 2001, 28, 684-694.
    • (2001) J. Oral Rehabil. , vol.28 , pp. 684-694
    • Gross, M.D.1    Arbel, G.2    Hershkovitz, I.3
  • 25
    • 77649229915 scopus 로고    scopus 로고
    • A. Towards characterization of craniofacial biomecha-nics. J. Craniofac. Surg
    • Szwedowski, T. D., Whyne, C. M., and Fialkov, J. A. Towards characterization of craniofacial biomecha-nics. J. Craniofac. Surg., January 2010, 21(1), 202-207.
    • January 2010 , vol.21 , Issue.1 , pp. 202-207
    • Szwedowski, T.D.1    Whyne, C.M.2    Fialkov, J.3
  • 26
    • 0033278238 scopus 로고    scopus 로고
    • Contribution of jaw muscle size and craniofacial morphology to human bite force magnitude
    • January
    • Raadsheer,M.C., van Eijden,T.M., van Ginkel,F.C., and Prahl-Andersen, B. Contribution of jaw muscle size and craniofacial morphology to human bite force magnitude. J. Dent. Res., January 1999, 78, 31-42.
    • (1999) J. Dent. Res. , vol.78 , pp. 31-42
    • Raadsheer, M.C.1    Van Eijden, T.M.2    Van Ginkel, F.C.3    Prahl-Andersen, B.4
  • 27
    • 0344440923 scopus 로고    scopus 로고
    • An improved method for the automatic mapping of computed tomography numbers onto finite element models
    • January
    • Taddei, F., Pancanti, A., and Viceconti, M. An improved method for the automatic mapping of computed tomography numbers onto finite element models. Med. Eng. Phys., January 2004, 26, 61-69.
    • (2004) Med. Eng. Phys. , vol.26 , pp. 61-69
    • Taddei, F.1    Pancanti, A.2    Viceconti, M.3
  • 28
    • 0345471427 scopus 로고    scopus 로고
    • Material properties assignment to finite element models of bone structures: A new method
    • December
    • Zannoni, C., Mantovani, R., and Viceconti, M. Material properties assignment to finite element models of bone structures: a new method. Med. Engng Physics, December 1998, 20, 735-740.
    • (1998) Med. Engng Physics , vol.20 , pp. 735-740
    • Zannoni, C.1    Mantovani, R.2    Viceconti, M.3
  • 32
    • 0026096845 scopus 로고
    • Mechanical properties of metaphyseal bone in the proximal femur
    • May 327-329
    • Lotz, J. C., Gerhart, T. N., and Hayes, W. C. Mechanical properties of metaphyseal bone in the proximal femur. J. Biomechanics, May 1991, 24, 317-325, 327-329.
    • (1991) J. Biomechanics , Issue.24 , pp. 317-325
    • Lotz, J.C.1    Gerhart, T.N.2    Hayes, W.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.