메뉴 건너뛰기




Volumn 34, Issue 5, 2005, Pages 551-558

Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis. Part 1: Advancement surgery posterior loading

Author keywords

Finite element analysis; Fixation; Mini plate and lag screw; Sagittal split ramus osteotomy

Indexed keywords

ARTICLE; BONE PLATE; BONE SCREW; COMPUTER PROGRAM; FINITE ELEMENT ANALYSIS; FRACTURE FIXATION; INTERMETHOD COMPARISON; JOINT MOBILITY; JOINT STABILITY; MANDIBLE OSTEOTOMY; MANDIBLE RECONSTRUCTION; MAXILLA; MECHANICAL STRESS; OSTEOSYNTHESIS; ROTATION; SIMULATION; STRESS STRAIN RELATIONSHIP;

EID: 20344408045     PISSN: 09015027     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijom.2004.10.009     Document Type: Article
Times cited : (78)

References (38)
  • 1
    • 0027483295 scopus 로고
    • Skeletal stability following miniplate fixation after bilateral sagittal split osteotomy for mandibular advancement
    • J. Abeloos C. De Clercq L. Neyt Skeletal stability following miniplate fixation after bilateral sagittal split osteotomy for mandibular advancement J Oral Maxillofac Surg 51 1993 366-369
    • (1993) J. Oral Maxillofac. Surg. , vol.51 , pp. 366-369
    • Abeloos, J.1    De Clercq, C.2    Neyt, L.3
  • 2
    • 0035129512 scopus 로고    scopus 로고
    • Preliminary investigation of the biomechanics of internal fixation of sagittal split osteotomies with miniplates using a newly designed in vitro testing model
    • J.E.A. Armstrong H.J. Lupointe N.J.V. Hogg A.D. Kwok Preliminary investigation of the biomechanics of internal fixation of sagittal split osteotomies with miniplates using a newly designed in vitro testing model J Oral Maxillofac Surg 59 2001 191-195
    • (2001) J. Oral Maxillofac. Surg. , vol.59 , pp. 191-195
    • Armstrong, J.E.A.1    Lupointe, H.J.2    Hogg, N.J.V.3    Kwok, A.D.4
  • 3
    • 0030322971 scopus 로고    scopus 로고
    • The experimental verification of the efficacy of finite element modeling to dental implant system
    • T. Baiamonte M.F. Abate F. Pizzarelo J. Lozada R. James The experimental verification of the efficacy of finite element modeling to dental implant system J Oral Implantol 22 1996 104-110
    • (1996) J. Oral Implantol. , vol.22 , pp. 104-110
    • Baiamonte, T.1    Abate, M.F.2    Pizzarelo, F.3    Lozada, J.4    James, R.5
  • 4
    • 0027959419 scopus 로고
    • Skeletal stability after mandibular advancement: A comparison of two rigid internal fixation techniques
    • J.E. Blomqvist S. Isaksson Skeletal stability after mandibular advancement: A comparison of two rigid internal fixation techniques J Oral Maxillofac Surg 52 1994 1133-1137
    • (1994) J. Oral Maxillofac. Surg. , vol.52 , pp. 1133-1137
    • Blomqvist, J.E.1    Isaksson, S.2
  • 6
    • 0035089387 scopus 로고    scopus 로고
    • Technique for applying 2 miniplates for treatment of mandibular angle fractures
    • B.H. Choi C.H. Suh Technique for applying 2 miniplates for treatment of mandibular angle fractures J Oral Maxillofac Surg 59 2001 353-354
    • (2001) J. Oral Maxillofac. Surg. , vol.59 , pp. 353-354
    • Choi, B.H.1    Suh, C.H.2
  • 7
    • 0028930259 scopus 로고
    • Stability testing of a two miniplate fixation technique for mandibular angle fractures: An in vitro study
    • B.H. Choi J.H. Yoo K.M. Kim H.S. Kang Stability testing of a two miniplate fixation technique for mandibular angle fractures: An in vitro study J Cranio-Maxillofac Surg 23 1995 122-125
    • (1995) J. Cranio-Maxillofac. Surg. , vol.23 , pp. 122-125
    • Choi, B.H.1    Yoo, J.H.2    Kim, K.M.3    Kang, H.S.4
  • 8
    • 0034221730 scopus 로고    scopus 로고
    • The effect of veneering materials on stress distribution in implant-supported fixed prosthetic restorations
    • Y. Ciftci Ş. Canay The effect of veneering materials on stress distribution in implant-supported fixed prosthetic restorations Int J Oral Maxillofac Impl 15 2000 571-582
    • (2000) Int. J. Oral Maxillofac. Impl. , vol.15 , pp. 571-582
    • Ciftci, Y.1    Canay, Ş.2
  • 9
    • 0025308268 scopus 로고
    • A comparative in vitro study of fixation of mandibular fractures with paraskeletal clamps or screw plates
    • C.E. Crofts A. Trowbridge T.M. Aung A comparative in vitro study of fixation of mandibular fractures with paraskeletal clamps or screw plates J Oral Maxillofac Surg 48 1990 461-467
    • (1990) J. Oral Maxillofac. Surg. , vol.48 , pp. 461-467
    • Crofts, C.E.1    Trowbridge, A.2    Aung, T.M.3
  • 10
    • 0035095856 scopus 로고    scopus 로고
    • Fixation of bimaxillary osteotomies with resorbable plates and screws: Experience in 20 consecutive cases
    • C.R. Edwards K.D. Kiely B.L. Eppley Fixation of bimaxillary osteotomies with resorbable plates and screws: Experience in 20 consecutive cases J Oral Maxilofac Surg 59 2001 271-276
    • (2001) J. Oral Maxilofac. Surg. , vol.59 , pp. 271-276
    • Edwards, C.R.1    Kiely, K.D.2    Eppley, B.L.3
  • 11
    • 0022455465 scopus 로고
    • Relapse following mandibular advancement with dental plus skeletal maxillomandibular fixation
    • E. Ellis J. Goallo Relapse following mandibular advancement with dental plus skeletal maxillomandibular fixation J Oral Maxillofac Surg 44 1986 509-515
    • (1986) J. Oral Maxillofac. Surg. , vol.44 , pp. 509-515
    • Ellis, E.1    Goallo, J.2
  • 12
    • 0036266730 scopus 로고    scopus 로고
    • Use of a 2.0-mm locking plate/screw system for mandibular fracture surgery
    • E. Ellis III J. Graham Use of a 2.0-mm locking plate/screw system for mandibular fracture surgery J Oral Maxillofac Surg 60 2002 642-645
    • (2002) J. Oral Maxillofac. Surg. , vol.60 , pp. 642-645
    • Ellis III, E.1    Graham, J.2
  • 13
    • 0030039058 scopus 로고    scopus 로고
    • Bite forces before and after surgical correction of mandibular prognathism
    • E. Ellis G.S. Throckmorton D.P. Sinn Bite forces before and after surgical correction of mandibular prognathism J Oral Maxilofac Surg 54 1996 176-181
    • (1996) J. Oral Maxilofac. Surg. , vol.54 , pp. 176-181
    • Ellis, E.1    Throckmorton, G.S.2    Sinn, D.P.3
  • 14
    • 12244296450 scopus 로고    scopus 로고
    • A three-dimensional numerical simulation of mandible fracture reduction with screwed miniplates
    • J.R. Fernandez M. Gallas M. Burguera J.M. Viano A three-dimensional numerical simulation of mandible fracture reduction with screwed miniplates J Biomech 36 2003 329-337
    • (2003) J. Biomech. , vol.36 , pp. 329-337
    • Fernandez, J.R.1    Gallas, M.2    Burguera, M.3    Viano, J.M.4
  • 15
    • 0027015701 scopus 로고
    • In vitro comparison of screw versus plate fixation in the sagittal split osteotomy
    • W.L. Foley T.W. Beckman In vitro comparison of screw versus plate fixation in the sagittal split osteotomy Int J Adult Orthodont Ortognath Surg 7 1992 147-151
    • (1992) Int. J. Adult Orthodont. Ortognath. Surg. , vol.7 , pp. 147-151
    • Foley, W.L.1    Beckman, T.W.2
  • 16
    • 0034116614 scopus 로고    scopus 로고
    • Measure of bite force and occlusal contact area before and. after bilateral sagittal split ramus osteotomy of the mandible using a new pressure-sensitive device: A preliminary report
    • K. Harada M. Watanabe K. Ohkura S. Enomoto Measure of bite force and occlusal contact area before and. after bilateral sagittal split ramus osteotomy of the mandible using a new pressure-sensitive device: A preliminary report J Oral Maxilofac Surg 58 1996 370-373
    • (1996) J. Oral Maxilofac. Surg. , vol.58 , pp. 370-373
    • Harada, K.1    Watanabe, M.2    Ohkura, K.3    Enomoto, S.4
  • 17
    • 0027238363 scopus 로고
    • Effects of screw number on reconstruction plating
    • R.H. Haug Effects of screw number on reconstruction plating Oral Surg Oral Med Oral Pathol 75 1993 664-668
    • (1993) Oral Surg. Oral Med. Oral Pathol. , vol.75 , pp. 664-668
    • Haug, R.H.1
  • 18
    • 0027518692 scopus 로고
    • The effects of screw number and length on two methods of tension band plating
    • R.H. Haug The effects of screw number and length on two methods of tension band plating J Oral Maxillofac Surg 51 1993 159-162
    • (1993) J. Oral Maxillofac. Surg. , vol.51 , pp. 159-162
    • Haug, R.H.1
  • 20
    • 0034786799 scopus 로고    scopus 로고
    • A biomechanical evaluation of mandibular angle fracture plating techniques
    • R.H. Haug T.T. Fallahi M. Goltz A biomechanical evaluation of mandibular angle fracture plating techniques J Oral Maxillofac Surg 59 2001 1199-1210
    • (2001) J. Oral Maxillofac. Surg. , vol.59 , pp. 1199-1210
    • Haug, R.H.1    Fallahi, T.T.2    Goltz, M.3
  • 22
    • 0027033620 scopus 로고
    • The sagittal ramus osteotomy. Stability of fixation with internal miniplates
    • J. Lee J.F. Piecuch The sagittal ramus osteotomy. Stability of fixation with internal miniplates Int J Oral Maxillofac Surg 21 1992 326-330
    • (1992) Int. J. Oral Maxillofac. Surg. , vol.21 , pp. 326-330
    • Lee, J.1    Piecuch, J.F.2
  • 23
    • 0036200479 scopus 로고    scopus 로고
    • Study by finite element method of the mechanical stress of selected biodegradable osteosynthesis screws in sagittal ramus osteotomy
    • P. Maurer S. Holweg W.D. Knoll J. Schubert Study by finite element method of the mechanical stress of selected biodegradable osteosynthesis screws in sagittal ramus osteotomy Br J Oral Maxillofac Surg 40 2002 76-83
    • (2002) Br. J. Oral Maxillofac. Surg. , vol.40 , pp. 76-83
    • Maurer, P.1    Holweg, S.2    Knoll, W.D.3    Schubert, J.4
  • 24
    • 0035751227 scopus 로고    scopus 로고
    • Finite element analysis of a tandem screw configuration in sagittal split osteotomy using biodegradable osteosynthesis screw
    • P. Maurer J. Schubert S. Holweg Finite element analysis of a tandem screw configuration in sagittal split osteotomy using biodegradable osteosynthesis screw Int J Adult Orthod Orthognath Surg 16 2001 300-304
    • (2001) Int. J. Adult Orthod. Orthognath. Surg. , vol.16 , pp. 300-304
    • Maurer, P.1    Schubert, J.2    Holweg, S.3
  • 25
    • 0028147306 scopus 로고
    • The effect of screw size and insertion technique on the stability of the mandibular sagittal split osteotomy
    • A. Schwimmer A.M. Greenberg F. Kummer A. Kaynar The effect of screw size and insertion technique on the stability of the mandibular sagittal split osteotomy J Oral Maxillofac Surg 52 1994 45-48
    • (1994) J. Oral Maxillofac. Surg. , vol.52 , pp. 45-48
    • Schwimmer, A.1    Greenberg, A.M.2    Kummer, F.3    Kaynar, A.4
  • 26
    • 0030471171 scopus 로고    scopus 로고
    • Functional stability of sagittal split ramus osteotomies: Effects of positional screw size and placement configuration
    • V. Shetty E. Freymiller D. McBrearty A.A. Caputo Functional stability of sagittal split ramus osteotomies: Effects of positional screw size and placement configuration J Oral Maxillofac Surg 54 1996 601-609
    • (1996) J. Oral Maxillofac. Surg. , vol.54 , pp. 601-609
    • Shetty, V.1    Freymiller, E.2    McBrearty, D.3    Caputo, A.A.4
  • 27
    • 0031982064 scopus 로고    scopus 로고
    • Comparison of fixation strengths of locking head and conventional screws, in fracture and reconstruction models
    • J.W. Sikes B.R. Smith D.P. Mukherjee K.A. Coward Comparison of fixation strengths of locking head and conventional screws, in fracture and reconstruction models J Oral Maxillofac Surg 50 1998 468-473
    • (1998) J. Oral Maxillofac. Surg. , vol.50 , pp. 468-473
    • Sikes, J.W.1    Smith, B.R.2    Mukherjee, D.P.3    Coward, K.A.4
  • 28
    • 0345714869 scopus 로고    scopus 로고
    • The fixation of sagittal split osteotomies with miniplates: The versatility of a technique
    • P.J. Stoelinga W.A. Borstlap The fixation of sagittal split osteotomies with miniplates: The versatility of a technique J Oral Maxillofac Surg 61 2003 1471-1476
    • (2003) J. Oral Maxillofac. Surg. , vol.61 , pp. 1471-1476
    • Stoelinga, P.J.1    Borstlap, W.A.2
  • 31
    • 0037381719 scopus 로고    scopus 로고
    • Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures
    • M.S. Tyler Cox M.W. Kohn T. Impelluso Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures J Oral Maxillofac Surg 61 2003 481-487
    • (2003) J. Oral Maxillofac. Surg. , vol.61 , pp. 481-487
    • Tyler Cox, M.S.1    Kohn, M.W.2    Impelluso, T.3
  • 32
    • 0034927039 scopus 로고    scopus 로고
    • Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy: A study in sheep mandibles
    • S. Uckan A. Schwimmer F. Kummer A.M. Greenberg Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy: A study in sheep mandibles Br J Oral Maxillofac Surg 39 2001 266-268
    • (2001) Br. J. Oral Maxillofac. Surg. , vol.39 , pp. 266-268
    • Uckan, S.1    Schwimmer, A.2    Kummer, F.3    Greenberg, A.M.4
  • 33
    • 0021889627 scopus 로고
    • Stability associated with mandibular advancement treated by rigid osseous fixation
    • J.E. Van Sickels C.M. Flanary Stability associated with mandibular advancement treated by rigid osseous fixation J Oral Maxillofac Surg 43 1985 338-341
    • (1985) J. Oral Maxillofac. Surg. , vol.43 , pp. 338-341
    • Van Sickels, J.E.1    Flanary, C.M.2
  • 35
    • 0000848373 scopus 로고
    • Mechanik des festen Körpers im plastischen deformablen Zustand. Nachrichten der Kgl. Gesellschaft der Wissenschaften Göttingen
    • R. Von Mises Mechanik des festen Körpers im plastischen deformablen Zustand. Nachrichten der Kgl. Gesellschaft der Wissenschaften Göttingen Mat-Phys Klasse 8 1913 582-592
    • (1913) Mat-Phys. Klasse , vol.8 , pp. 582-592
    • Von Mises, R.1
  • 36
    • 0035209435 scopus 로고    scopus 로고
    • Radiographic stereophotogrammetric evaluation of intersegmental stability after mandibular sagittal split osteotomy and rigid fixation
    • G. Wall B. Rosenquist Radiographic stereophotogrammetric evaluation of intersegmental stability after mandibular sagittal split osteotomy and rigid fixation J Oral Maxillofac Surg 59 2001 1427-1435
    • (2001) J. Oral Maxillofac. Surg. , vol.59 , pp. 1427-1435
    • Wall, G.1    Rosenquist, B.2
  • 37
    • 0035209435 scopus 로고    scopus 로고
    • Radiographic stereophotogrammetric evaluation of intersegmental stability after mandibular sagittal split osteotomy and rigid fixation
    • G. Wall B. Rosenquist Radiographic stereophotogrammetric evaluation of intersegmental stability after mandibular sagittal split osteotomy and rigid fixation J Oral Maxilofac Surg 59 2001 1427-1435
    • (2001) J. Oral Maxilofac. Surg. , vol.59 , pp. 1427-1435
    • Wall, G.1    Rosenquist, B.2
  • 38
    • 0025191328 scopus 로고
    • Stability of mandibular advancement after sagittal osteotomy with screw or wire fixation: A comparative study
    • I.M. Watzke T.A. Turvey C. Phillips W.R. Proffit Stability of mandibular advancement after sagittal osteotomy with screw or wire fixation: A comparative study Oral Maxillofac Surg 48 1990 108-121
    • (1990) Oral Maxillofac. Surg. , vol.48 , pp. 108-121
    • Watzke, I.M.1    Turvey, T.A.2    Phillips, C.3    Proffit, W.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.