메뉴 건너뛰기




Volumn 39, Issue 1, 2014, Pages 7-27

Transcatheter Aortic Valve-in-Valve Implantation for Patients With Degenerative Surgical Bioprosthetic Valves

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE STENOSIS; AORTOGRAPHY; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CORONARY ARTERY OBSTRUCTION; DEVICE MALPOSITION; HEART VALVE BIOPROSTHESIS; HEMODYNAMICS; HUMAN; POSTOPERATIVE COMPLICATION; PROSTHESIS FAILURE; SURGICAL TECHNIQUE; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSCATHETER AORTIC VALVE IN VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSLUMINAL VALVULOPLASTY;

EID: 84890019037     PISSN: 01462806     EISSN: 15356280     Source Type: Journal    
DOI: 10.1016/j.cpcardiol.2013.10.001     Document Type: Article
Times cited : (52)

References (58)
  • 1
    • 58249086539 scopus 로고    scopus 로고
    • Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database
    • Brown J.M., O'Brien S.M., Wu C., Sikora J.A., Griffith B.P., Gammie J.S. Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database. J Thorac Cardiovasc Surg 2009, 137:82-90.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 82-90
    • Brown, J.M.1    O'Brien, S.M.2    Wu, C.3    Sikora, J.A.4    Griffith, B.P.5    Gammie, J.S.6
  • 2
    • 55249125191 scopus 로고    scopus 로고
    • Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines
    • Bonow R.O., Carabello B.A., Chatterjee K., et al. Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation 2008, 118:e523-e661.
    • (2008) Circulation , vol.118
    • Bonow, R.O.1    Carabello, B.A.2    Chatterjee, K.3
  • 3
    • 84867283287 scopus 로고    scopus 로고
    • Guidelines on the management of valvular heart disease (version 2012)
    • Vahanian A., Alfieri O., Andreotti F., et al. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J 2012, 33:2451-2496.
    • (2012) Eur Heart J , vol.33 , pp. 2451-2496
    • Vahanian, A.1    Alfieri, O.2    Andreotti, F.3
  • 6
    • 1542613967 scopus 로고    scopus 로고
    • Late incidence and determinants of reoperation in patients with prosthetic heart valves
    • Ruel M., Kulik A., Rubens F.D., et al. Late incidence and determinants of reoperation in patients with prosthetic heart valves. Eur J Cardiothorac Surg 2004, 25:364-370.
    • (2004) Eur J Cardiothorac Surg , vol.25 , pp. 364-370
    • Ruel, M.1    Kulik, A.2    Rubens, F.D.3
  • 7
    • 84876514740 scopus 로고    scopus 로고
    • Long-term safety and effectiveness of mechanical versus biologic aortic valve prostheses in older patients: results from the Society of Thoracic Surgeons Adult Cardiac Surgery National Database
    • Brennan J.M., Edwards F.H., Zhao Y., et al. Long-term safety and effectiveness of mechanical versus biologic aortic valve prostheses in older patients: results from the Society of Thoracic Surgeons Adult Cardiac Surgery National Database. Circulation 2013, 127:1647-1655.
    • (2013) Circulation , vol.127 , pp. 1647-1655
    • Brennan, J.M.1    Edwards, F.H.2    Zhao, Y.3
  • 8
    • 0035526239 scopus 로고    scopus 로고
    • Repeat heart valve surgery: risk factors for operative mortality
    • Jones J.M., O'Kane H., Gladstone D.J., et al. Repeat heart valve surgery: risk factors for operative mortality. J Thorac Cardiovasc Surg 2001, 122:913-918.
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 913-918
    • Jones, J.M.1    O'Kane, H.2    Gladstone, D.J.3
  • 10
    • 79953081994 scopus 로고    scopus 로고
    • Redo aortic valve surgery: early and late outcomes
    • Leontyev S., Borger M.A., Davierwala P., et al. Redo aortic valve surgery: early and late outcomes. Ann Thorac Surg 2011, 91:1120-1126.
    • (2011) Ann Thorac Surg , vol.91 , pp. 1120-1126
    • Leontyev, S.1    Borger, M.A.2    Davierwala, P.3
  • 11
    • 84864744842 scopus 로고    scopus 로고
    • Current status of transcatheter aortic valve replacement
    • Webb J.G., Wood D.A. Current status of transcatheter aortic valve replacement. J Am Coll Cardiol 2012, 60:483-492.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 483-492
    • Webb, J.G.1    Wood, D.A.2
  • 12
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon M.B., Smith C.R., Mack M., et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010, 363:1597-1607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 13
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • Smith C.R., Leon M.B., Mack M.J., et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 2011, 364:2187-2198.
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 14
    • 77951767167 scopus 로고    scopus 로고
    • Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves
    • Webb J.G., Wood D.A., Ye J., et al. Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves. Circulation 2010, 121:1848-1857.
    • (2010) Circulation , vol.121 , pp. 1848-1857
    • Webb, J.G.1    Wood, D.A.2    Ye, J.3
  • 15
    • 80855156726 scopus 로고    scopus 로고
    • Transcatheter valve-in-valve implantation for failed surgical bioprosthetic valves
    • Gurvitch R., Cheung A., Ye J., et al. Transcatheter valve-in-valve implantation for failed surgical bioprosthetic valves. J Am Coll Cardiol 2011, 58:2196-2209.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 2196-2209
    • Gurvitch, R.1    Cheung, A.2    Ye, J.3
  • 16
    • 79960568094 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 1)
    • Piazza N., Bleiziffer S., Brockmann G., et al. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 1). JACC Cardiovasc Interv 2011, 4:721-732.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 721-732
    • Piazza, N.1    Bleiziffer, S.2    Brockmann, G.3
  • 17
    • 79960594587 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2)
    • Piazza N., Bleiziffer S., Brockmann G., et al. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2). JACC Cardiovasc Interv 2011, 4:733-742.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 733-742
    • Piazza, N.1    Bleiziffer, S.2    Brockmann, G.3
  • 18
    • 14244266288 scopus 로고    scopus 로고
    • Calcification of tissue heart valve substitutes: progress toward understanding and prevention
    • Schoen F.J., Levy R.J. Calcification of tissue heart valve substitutes: progress toward understanding and prevention. Ann Thorac Surg 2005, 79:1072-1080.
    • (2005) Ann Thorac Surg , vol.79 , pp. 1072-1080
    • Schoen, F.J.1    Levy, R.J.2
  • 19
    • 0027006911 scopus 로고
    • Porcine aortic valve bioprostheses: morphologic and functional considerations
    • Hilbert S.L., Ferrans V.J. Porcine aortic valve bioprostheses: morphologic and functional considerations. J Long Term Eff Med Implants 1992, 2:99-112.
    • (1992) J Long Term Eff Med Implants , vol.2 , pp. 99-112
    • Hilbert, S.L.1    Ferrans, V.J.2
  • 20
    • 0032192099 scopus 로고    scopus 로고
    • Inaccurate and misleading valve sizing: a proposed standard for valve size nomenclature
    • Christakis G.T., Buth K.J., Goldman B.S., et al. Inaccurate and misleading valve sizing: a proposed standard for valve size nomenclature. Ann Thorac Surg 1998, 66:1198-1203.
    • (1998) Ann Thorac Surg , vol.66 , pp. 1198-1203
    • Christakis, G.T.1    Buth, K.J.2    Goldman, B.S.3
  • 21
    • 84868523264 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: results from the global valve-in-valve registry
    • Dvir D., Webb J., Brecker S., et al. Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: results from the global valve-in-valve registry. Circulation 2012, 126:2335-2344.
    • (2012) Circulation , vol.126 , pp. 2335-2344
    • Dvir, D.1    Webb, J.2    Brecker, S.3
  • 22
    • 35148872276 scopus 로고    scopus 로고
    • Stentless vs. stented aortic valve bioprostheses: a prospective randomized controlled trial
    • Dunning J., Graham R.J., Thambyrajah J., Stewart M.J., Kendall S.W., Hunter S. Stentless vs. stented aortic valve bioprostheses: a prospective randomized controlled trial. Eur Heart J 2007, 28:369-374.
    • (2007) Eur Heart J , vol.28 , pp. 369-374
    • Dunning, J.1    Graham, R.J.2    Thambyrajah, J.3    Stewart, M.J.4    Kendall, S.W.5    Hunter, S.6
  • 23
    • 34848854143 scopus 로고    scopus 로고
    • Is a stentless aortic valve superior to conventional bioprosthetic valves for aortic valve replacement?
    • Kallikourdis A., Jacob S. Is a stentless aortic valve superior to conventional bioprosthetic valves for aortic valve replacement?. Interact Cardiovasc Thorac Surg 2007, 6:665-672.
    • (2007) Interact Cardiovasc Thorac Surg , vol.6 , pp. 665-672
    • Kallikourdis, A.1    Jacob, S.2
  • 24
    • 2442644342 scopus 로고    scopus 로고
    • Complications of prosthetic heart valves
    • Vesey J.M., Otto C.M. Complications of prosthetic heart valves. Curr Cardiol Rep 2004, 6:106-111.
    • (2004) Curr Cardiol Rep , vol.6 , pp. 106-111
    • Vesey, J.M.1    Otto, C.M.2
  • 25
    • 0028882284 scopus 로고
    • Carpentier-Edwards standard porcine bioprosthesis: clinical performance to seventeen years
    • [discussion 1007]
    • Jamieson W.R., Munro A.I., Miyagishima R.T., Allen P., Burr L.H., Tyers G.F. Carpentier-Edwards standard porcine bioprosthesis: clinical performance to seventeen years. Ann Thorac Surg 1995, 60:999-1006. [discussion 1007].
    • (1995) Ann Thorac Surg , vol.60 , pp. 999-1006
    • Jamieson, W.R.1    Munro, A.I.2    Miyagishima, R.T.3    Allen, P.4    Burr, L.H.5    Tyers, G.F.6
  • 26
    • 0023801814 scopus 로고
    • Carpentier-Edwards standard porcine bioprosthesis: primary tissue failure (structural valve deterioration) by age groups
    • Jamieson W.R., Rosado L.J., Munro A.I., et al. Carpentier-Edwards standard porcine bioprosthesis: primary tissue failure (structural valve deterioration) by age groups. Ann Thorac Surg 1988, 46:155-162.
    • (1988) Ann Thorac Surg , vol.46 , pp. 155-162
    • Jamieson, W.R.1    Rosado, L.J.2    Munro, A.I.3
  • 28
    • 0023854796 scopus 로고
    • Problems encountered with catheter balloon valvuloplasty of bioprosthetic aortic valves
    • McKay C.R., Waller B.F., Hong R., Rubin N., Reid C.L., Rahimtoola S.H. Problems encountered with catheter balloon valvuloplasty of bioprosthetic aortic valves. Am Heart J 1988, 115:463-465.
    • (1988) Am Heart J , vol.115 , pp. 463-465
    • McKay, C.R.1    Waller, B.F.2    Hong, R.3    Rubin, N.4    Reid, C.L.5    Rahimtoola, S.H.6
  • 29
    • 0024330038 scopus 로고
    • Balloon dilatation of a porcine bioprosthetic valve in aortic position
    • Ramondo A., Gemelli M., Chioin R. Balloon dilatation of a porcine bioprosthetic valve in aortic position. Int J Cardiol 1989, 24:105-107.
    • (1989) Int J Cardiol , vol.24 , pp. 105-107
    • Ramondo, A.1    Gemelli, M.2    Chioin, R.3
  • 30
    • 0026337979 scopus 로고
    • Effectiveness of balloon percutaneous valvuloplasty for stenotic bioprosthetic valves in different positions
    • Orbe L.C., Sobrino N., Maté I., et al. Effectiveness of balloon percutaneous valvuloplasty for stenotic bioprosthetic valves in different positions. Am J Cardiol 1991, 68:1719-1721.
    • (1991) Am J Cardiol , vol.68 , pp. 1719-1721
    • Orbe, L.C.1    Sobrino, N.2    Maté, I.3
  • 31
    • 79952234467 scopus 로고    scopus 로고
    • Repeated successful balloon valvuloplasty of a bioprosthetic aortic valve in a nonagenerian
    • Dejam A., Hokinson M., Laham R. Repeated successful balloon valvuloplasty of a bioprosthetic aortic valve in a nonagenerian. Catheter Cardiovasc Interv 2011, 77:589-592.
    • (2011) Catheter Cardiovasc Interv , vol.77 , pp. 589-592
    • Dejam, A.1    Hokinson, M.2    Laham, R.3
  • 32
    • 26444474630 scopus 로고    scopus 로고
    • New insights in minimally invasive valve replacement: description of a cooperative approach for the off-pump replacement of mitral valves
    • Boudjemline Y., Pineau E., Borenstein N., Behr L., Bonhoeffer P. New insights in minimally invasive valve replacement: description of a cooperative approach for the off-pump replacement of mitral valves. Eur Heart J 2005, 26:2013-2017.
    • (2005) Eur Heart J , vol.26 , pp. 2013-2017
    • Boudjemline, Y.1    Pineau, E.2    Borenstein, N.3    Behr, L.4    Bonhoeffer, P.5
  • 33
    • 34250796217 scopus 로고    scopus 로고
    • Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation
    • Walther T., Falk V., Dewey T., et al. Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation. J Am Coll Cardiol 2007, 50:56-60.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 56-60
    • Walther, T.1    Falk, V.2    Dewey, T.3
  • 35
    • 79960942231 scopus 로고    scopus 로고
    • Valve-in-valve hemodynamics of 20-mm transcatheter aortic valves in small bioprostheses
    • Azadani A.N., Jaussaud N., Ge L., Chitsaz S., Chuter T.A., Tseng E.E. Valve-in-valve hemodynamics of 20-mm transcatheter aortic valves in small bioprostheses. Ann Thorac Surg 2011, 92:548-555.
    • (2011) Ann Thorac Surg , vol.92 , pp. 548-555
    • Azadani, A.N.1    Jaussaud, N.2    Ge, L.3    Chitsaz, S.4    Chuter, T.A.5    Tseng, E.E.6
  • 36
    • 78650205432 scopus 로고    scopus 로고
    • Transcatheter valve-in-valve implantation for failing bioprosthetic valves
    • Azadani A.N., Tseng E.E. Transcatheter valve-in-valve implantation for failing bioprosthetic valves. Future Cardiol 2010, 6:811-831.
    • (2010) Future Cardiol , vol.6 , pp. 811-831
    • Azadani, A.N.1    Tseng, E.E.2
  • 37
    • 34250796217 scopus 로고    scopus 로고
    • Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation
    • Walther T., Falk V., Dewey T., et al. Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation. J Am Coll Cardiol 2007, 50:56-60.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 56-60
    • Walther, T.1    Falk, V.2    Dewey, T.3
  • 38
    • 36348967094 scopus 로고    scopus 로고
    • Transcatheter valve in valve implants for failed prosthetic valves
    • Webb J.G. Transcatheter valve in valve implants for failed prosthetic valves. Catheter Cardiovasc Interv 2007, 70:765-766.
    • (2007) Catheter Cardiovasc Interv , vol.70 , pp. 765-766
    • Webb, J.G.1
  • 39
    • 36348952550 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bio-prosthesis: the first valve in valve procedure using the corevale revalving system
    • Wenaweser P., Buellesfeld L., Gerckens U., Grube E. Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bio-prosthesis: the first valve in valve procedure using the corevale revalving system. Catheter Cardiovasc Interv 2007, 70:760-764.
    • (2007) Catheter Cardiovasc Interv , vol.70 , pp. 760-764
    • Wenaweser, P.1    Buellesfeld, L.2    Gerckens, U.3    Grube, E.4
  • 40
    • 81855227655 scopus 로고    scopus 로고
    • Transcatheter valve-in-valve implantation using corevalve revalving system for failed surgical aortic bioprostheses
    • Bedogni F., Laudisa M.L., Pizzocri S., et al. Transcatheter valve-in-valve implantation using corevalve revalving system for failed surgical aortic bioprostheses. JACC Cardiovasc Interv 2011, 4:1228-1234.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 1228-1234
    • Bedogni, F.1    Laudisa, M.L.2    Pizzocri, S.3
  • 41
    • 81855224513 scopus 로고    scopus 로고
    • Valve-in-valve transcatheter aortic valve implantation for degenerated bioprosthetic heart valves
    • Eggebrecht H., Schäfer U., Treede H., et al. Valve-in-valve transcatheter aortic valve implantation for degenerated bioprosthetic heart valves. JACC Cardiovasc Interv 2011, 4:1218-1227.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 1218-1227
    • Eggebrecht, H.1    Schäfer, U.2    Treede, H.3
  • 42
    • 80855138368 scopus 로고    scopus 로고
    • Transcatheter aortic and mitral valve implantations for failed bioprosthetic heart valves
    • Dvir D., Assali A., Vaknin-Assa H., et al. Transcatheter aortic and mitral valve implantations for failed bioprosthetic heart valves. J Invasive Cardiol 2011, 23:377-381.
    • (2011) J Invasive Cardiol , vol.23 , pp. 377-381
    • Dvir, D.1    Assali, A.2    Vaknin-Assa, H.3
  • 43
    • 77950548376 scopus 로고    scopus 로고
    • First trans-axillary implantation of Edwards Sapien valve to treat an incompetent aortic bioprosthesis
    • Sharp A.S., Michev I., Colombo A. First trans-axillary implantation of Edwards Sapien valve to treat an incompetent aortic bioprosthesis. Catheter Cardiovasc Interv 2010, 75:507-510.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 507-510
    • Sharp, A.S.1    Michev, I.2    Colombo, A.3
  • 44
    • 73049102176 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for stenosed and regurgitant aortic valve bioprostheses corevalve for failed bioprosthetic aortic valve replacements
    • Khawaja M.Z., Haworth P., Ghuran A., et al. Transcatheter aortic valve implantation for stenosed and regurgitant aortic valve bioprostheses corevalve for failed bioprosthetic aortic valve replacements. J Am Coll Cardiol 2010, 55:97-101.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 97-101
    • Khawaja, M.Z.1    Haworth, P.2    Ghuran, A.3
  • 45
    • 77953475765 scopus 로고    scopus 로고
    • Transcatheter valve-in-valve implantation for the treatment of stentless aortic valve dysfunction
    • Rodés-Cabau J., Dumont E., Doyle D., Lemieux J. Transcatheter valve-in-valve implantation for the treatment of stentless aortic valve dysfunction. J Thorac Cardiovas Surg 2010, 140:246-248.
    • (2010) J Thorac Cardiovas Surg , vol.140 , pp. 246-248
    • Rodés-Cabau, J.1    Dumont, E.2    Doyle, D.3    Lemieux, J.4
  • 46
    • 77952316738 scopus 로고    scopus 로고
    • Transapical off-pump valve-in-valve implantation in patients with degenerated aortic xenografts
    • Kempfert J., Van Linden A., Linke A., et al. Transapical off-pump valve-in-valve implantation in patients with degenerated aortic xenografts. Ann Thorac Surg 2010, 89:1934-1941.
    • (2010) Ann Thorac Surg , vol.89 , pp. 1934-1941
    • Kempfert, J.1    Van Linden, A.2    Linke, A.3
  • 47
    • 78649657589 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for treatment of patients with degenerated aortic bioprostheses-valve-in-valve technique
    • Gotzmann M., Mugge A., Bojara W. Transcatheter aortic valve implantation for treatment of patients with degenerated aortic bioprostheses-valve-in-valve technique. Catheter Cardiovasc Interv 2010, 76:1000-1006.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 1000-1006
    • Gotzmann, M.1    Mugge, A.2    Bojara, W.3
  • 48
    • 79960392734 scopus 로고    scopus 로고
    • Transapical aortic valve implantation after previous aortic valve replacement: clinical proof of the valve-in-valve concept
    • Pasic M., Unbehaun A., Dreysse S., et al. Transapical aortic valve implantation after previous aortic valve replacement: clinical proof of the valve-in-valve concept. J Thorac Cardiovasc Surg 2011, 142:270-277.
    • (2011) J Thorac Cardiovasc Surg , vol.142 , pp. 270-277
    • Pasic, M.1    Unbehaun, A.2    Dreysse, S.3
  • 49
    • 78649439493 scopus 로고    scopus 로고
    • Series of transcatheter valve-in-valve implantations in high-risk patients with degenerated bioprostheses in aortic and mitral position
    • Seiffert M., Franzen O., Conradi L., et al. Series of transcatheter valve-in-valve implantations in high-risk patients with degenerated bioprostheses in aortic and mitral position. Catheter Cardiovasc Interv 2010, 76:608-615.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 608-615
    • Seiffert, M.1    Franzen, O.2    Conradi, L.3
  • 50
    • 84872317277 scopus 로고    scopus 로고
    • Transcatheter valve-in-valve therapies: patient selection, prosthesis assessment and selection, results, and future directions
    • Wilbring M., Alexiou K., Tugtekin S.M., et al. Transcatheter valve-in-valve therapies: patient selection, prosthesis assessment and selection, results, and future directions. Current Cardiol Rep 2013, 15:341.
    • (2013) Current Cardiol Rep , vol.15 , pp. 341
    • Wilbring, M.1    Alexiou, K.2    Tugtekin, S.M.3
  • 51
    • 84878781051 scopus 로고    scopus 로고
    • Transcatheter heart valve implantation for failing surgical bioprostheses: technical considerations and evidence for valve-in-valve procedures
    • Mylotte D., Lange R., Martucci G., Piazza N. Transcatheter heart valve implantation for failing surgical bioprostheses: technical considerations and evidence for valve-in-valve procedures. Heart 2013, 99:960-967.
    • (2013) Heart , vol.99 , pp. 960-967
    • Mylotte, D.1    Lange, R.2    Martucci, G.3    Piazza, N.4
  • 52
    • 84879420397 scopus 로고    scopus 로고
    • A guide to fluoroscopic identification and design of bioprosthetic valves: a reference for valve-in-valve procedure
    • Bapat V., Mydin I., Chadalavada S., Tehrani H., Attia R., Thomas M. A guide to fluoroscopic identification and design of bioprosthetic valves: a reference for valve-in-valve procedure. Catheter Cardiovasc Interv 2013, 81:853-861.
    • (2013) Catheter Cardiovasc Interv , vol.81 , pp. 853-861
    • Bapat, V.1    Mydin, I.2    Chadalavada, S.3    Tehrani, H.4    Attia, R.5    Thomas, M.6
  • 53
    • 84886073216 scopus 로고    scopus 로고
    • Predictive factors, management and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicenter registry
    • Ribeiro H.B., Webb J.G., Makkar R.R., et al. Predictive factors, management and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicenter registry. J Am Coll Cardiol 2013, 62:1552-1562.
    • (2013) J Am Coll Cardiol , vol.62 , pp. 1552-1562
    • Ribeiro, H.B.1    Webb, J.G.2    Makkar, R.R.3
  • 54
    • 79951874149 scopus 로고    scopus 로고
    • Coronary obstruction following transcatheter aortic valve-in-valve implantation for failed surgical bioprostheses
    • Gurvitch R., Cheung A., Bedogni F., Webb J.G. Coronary obstruction following transcatheter aortic valve-in-valve implantation for failed surgical bioprostheses. Catheter Cardiovasc Interv 2011, 77:439-444.
    • (2011) Catheter Cardiovasc Interv , vol.77 , pp. 439-444
    • Gurvitch, R.1    Cheung, A.2    Bedogni, F.3    Webb, J.G.4
  • 55
    • 84880609872 scopus 로고    scopus 로고
    • Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: a study of multiple valve implants in the U.S. PARTNER trial placement of aortic transcatheter valve trial Edwards SAPIEN transcatheter heart valve
    • Makkar R.R., Jilaihawi H., Chakravarty T., et al. Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: a study of multiple valve implants in the U.S. PARTNER trial placement of aortic transcatheter valve trial Edwards SAPIEN transcatheter heart valve. J Am Coll Cardiol 2013, 62:418-430.
    • (2013) J Am Coll Cardiol , vol.62 , pp. 418-430
    • Makkar, R.R.1    Jilaihawi, H.2    Chakravarty, T.3
  • 56
    • 84888137206 scopus 로고    scopus 로고
    • First-in-human valve-in-valve implantation of a 20mm balloon expandable transcatheter heart valve
    • Binder R.K., Wood D., Webb J.G., Cheung A. First-in-human valve-in-valve implantation of a 20mm balloon expandable transcatheter heart valve. Catheter Cardiovasc Interv 2013, 82:E929-E931.
    • (2013) Catheter Cardiovasc Interv , vol.82
    • Binder, R.K.1    Wood, D.2    Webb, J.G.3    Cheung, A.4
  • 57
    • 0242524394 scopus 로고    scopus 로고
    • Normal values for Doppler echocardiographic assessment of heart valve prostheses
    • Rosenhek R., Binder T., Maurer G., Baumgartner H. Normal values for Doppler echocardiographic assessment of heart valve prostheses. J Am Soc Echocardiogr 2003, 16:1116-1127.
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 1116-1127
    • Rosenhek, R.1    Binder, T.2    Maurer, G.3    Baumgartner, H.4
  • 58
    • 84872685837 scopus 로고    scopus 로고
    • 5-year outcome after transcatheter aortic valve implantation
    • Toggweiler S., Humphries K.H., Lee M., et al. 5-year outcome after transcatheter aortic valve implantation. J Am Coll Cardiol 2013, 61:413-419.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 413-419
    • Toggweiler, S.1    Humphries, K.H.2    Lee, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.