Transcatheter aortic valves inadequately relieve stenosis in small degenerated bioprostheses

Author keywords

Aortic valve replacement; Circulatory hemodynamics; Endovascular procedures stents; Heart valve bioprosthesis; In vitro studies models

Indexed keywords

AORTA VALVE PROSTHESIS; AORTA VALVE REGURGITATION; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; ARTERY CATHETERIZATION; ARTICLE; CONTROLLED STUDY; DISEASE SEVERITY; HEART HEMODYNAMICS; HEART VALVE BIOPROSTHESIS; INTERMETHOD COMPARISON; PRESSURE GRADIENT; PRIORITY JOURNAL; AORTIC VALVE INSUFFICIENCY; AORTIC VALVE STENOSIS; BIOPROSTHESIS; DEVICES; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; HEMODYNAMICS; MATERIALS TESTING; PATHOPHYSIOLOGY; PROCEDURES; PROSTHESIS; PROSTHESIS FAILURE;

EID: 77954554337     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2009.225144     Document Type: Article
Times cited : (61)

References (23)
  • 5
    • 36348967094 scopus 로고    scopus 로고
    • Transcatheter valve in valve implants for failed prosthetic valves
    • Webb JG. Transcatheter valve in valve implants for failed prosthetic valves. Cathet Cardiovasc Interv 2007; 70: 765-766.
    • (2007) Cathet Cardiovasc Interv , vol.70 , pp. 765-766
    • Webb, J.G.1
  • 7
    • 65649113207 scopus 로고    scopus 로고
    • Transapical transcatheter treatment of a stenosed aortic valve bioprosthesis using the Edwards SAPIEN transcatheter heart valve
    • Klaaborg KE, Egeblad H, Jakobsen CJ, Terp K, Lindskov C, Andersen HR, Thuesen L. Transapical transcatheter treatment of a stenosed aortic valve bioprosthesis using the Edwards SAPIEN transcatheter heart valve. Ann Thorac Surg 2009; 87: 1943-1946.
    • (2009) Ann Thorac Surg , vol.87 , pp. 1943-1946
    • Klaaborg, K.E.1    Egeblad, H.2    Jakobsen, C.J.3    Terp, K.4    Lindskov, C.5    Andersen, H.R.6    Thuesen, L.7
  • 10
    • 36348952550 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bioprosthesis: The first valve in valve procedure using the Corevalve Revalving system
    • Wenaweser P, Buellesfeld L, Gerckens U, Grube E. Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bioprosthesis: the first valve in valve procedure using the Corevalve Revalving system. Catheter Cardiovasc Interv 2007; 70: 760-764.
    • (2007) Catheter Cardiovasc Interv , vol.70 , pp. 760-764
    • Wenaweser, P.1    Buellesfeld, L.2    Gerckens, U.3    Grube, E.4
  • 11
    • 33748937701 scopus 로고    scopus 로고
    • A repositionable valved stent for endovascular treatment of deteriorated bioprostheses
    • Zegdi R, Khabbaz Z, Borenstein N, Fabiani JN. A repositionable valved stent for endovascular treatment of deteriorated bioprostheses. J Am Coll Cardiol 2006; 48: 1365-1368.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1365-1368
    • Zegdi, R.1    Khabbaz, Z.2    Borenstein, N.3    Fabiani, J.N.4
  • 13
    • 33750714450 scopus 로고    scopus 로고
    • Failure modes of the Carpentier-Edwards pericardial bioprosthesis in the aortic position
    • discussion 427-428
    • Roselli EE, Smedira NG, Blackstone EH. Failure modes of the Carpentier-Edwards pericardial bioprosthesis in the aortic position. J Heart Valve Dis 2006; 15: 421-427; discussion 427-428.
    • (2006) J Heart Valve Dis , vol.15 , pp. 421-427
    • Roselli, E.E.1    Smedira, N.G.2    Blackstone, E.H.3
  • 14
    • 0031660448 scopus 로고    scopus 로고
    • Long-term Doppler echocardiographic results of aortic or mitral valve replacement with Biocor porcine bioprosthesis
    • Myken PS, Berggren HE, Larsson S, Roberts B, Wallentin I, Caidahl K. Long-term Doppler echocardiographic results of aortic or mitral valve replacement with Biocor porcine bioprosthesis. J Thorac Cardiovasc Surg 1998; 116: 599-608.
    • (1998) J Thorac Cardiovasc Surg , vol.116 , pp. 599-608
    • Myken, P.S.1    Berggren, H.E.2    Larsson, S.3    Roberts, B.4    Wallentin, I.5    Caidahl, K.6
  • 15
    • 0034143653 scopus 로고    scopus 로고
    • Turina Ml. Reoperative surgery for degenerated aortic bioprostheses: Predictors for emergency surgery and reoperative mortality
    • Vogt PR, Brunner-LaRocca H, Sidler P, Zund G, Truniger K, Lachat M, Turina J, Turina Ml. Reoperative surgery for degenerated aortic bioprostheses: predictors for emergency surgery and reoperative mortality. Eur J Cardiothorac Surg 2000; 17: 134-139.
    • (2000) Eur J Cardiothorac Surg , vol.17 , pp. 134-139
    • Vogt, P.R.1    Brunner-Larocca, H.2    Sidler, P.3    Zund, G.4    Truniger, K.5    Lachat, M.6    Turina, J.7
  • 16
    • 77954554386 scopus 로고    scopus 로고
    • Cardiovascular implants - Cardiac valve prostheses. ISO 5840
    • Cardiovascular implants - Cardiac valve prostheses. ISO 5840:2005.
    • (2005)
  • 17
    • 0006507249 scopus 로고
    • Division of Cardiovascular and Neurological Devices. Version 4.1. Washington, Center for Devices and Radiological Health, Food and Drug Administration
    • Division of Cardiovascular and Neurological Devices. Draft Replacement Heart Valve Guidance, Version 4.1. Washington, DC: Center for Devices and Radiological Health, Food and Drug Administration; 1994: 1-134.
    • (1994) Draft Replacement Heart Valve Guidance , pp. 1-134
  • 23


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.