메뉴 건너뛰기




Volumn , Issue , 2009, Pages 550-571

Electromagnetic Interference and Implantable Devices

Author keywords

Asynchronous pacing; Electromyograms nerve conduction studies; Environmental electromagnetic interference; Extracorporeal shock wave lithotripsy (ESWL); Mode resetting (power on reset, or electrical reset)

Indexed keywords


EID: 84889305076     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9781444300659.ch12     Document Type: Chapter
Times cited : (2)

References (54)
  • 1
    • 0003070689 scopus 로고    scopus 로고
    • Electromagnetic interference with implantable devices
    • Ellenbogen KA, Kay GN, Wilkoff BL, eds., 2nd edn. Philadelphia: WB Saunders Co.
    • Hayes DL, Strathmore NF. Electromagnetic interference with implantable devices. In: Ellenbogen KA, Kay GN, Wilkoff BL, eds. Clinical cardiac pacing and defibrillation, 2nd edn. Philadelphia: WB Saunders Co., 2000:939-52.
    • (2000) Clinical cardiac pacing and defibrillation , pp. 939-952
    • Hayes, D.L.1    Strathmore, N.F.2
  • 2
    • 20044376073 scopus 로고    scopus 로고
    • Comparative efficacy of monophasic and biphasic waveforms for transthoracic cardioversion of atrial fibrillation and atrial flutter
    • Gurevitz OT, Ammash NM, Malouf JF et al. Comparative efficacy of monophasic and biphasic waveforms for transthoracic cardioversion of atrial fibrillation and atrial flutter. Am Heart J 2005; 149:316-21.
    • (2005) Am Heart J , vol.149 , pp. 316-321
    • Gurevitz, O.T.1    Ammash, N.M.2    Malouf, J.F.3
  • 4
    • 0029816882 scopus 로고    scopus 로고
    • Acute effects of radiofrequency ablation of atrial arrhythmias on implanted permanent pacing systems
    • Ellenbogen KA, Wood MA, Stambler BS. Acute effects of radiofrequency ablation of atrial arrhythmias on implanted permanent pacing systems. Pacing Clin Electrophysiol 1996; 19:1287-95.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 1287-1295
    • Ellenbogen, K.A.1    Wood, M.A.2    Stambler, B.S.3
  • 6
    • 0023253185 scopus 로고
    • Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers
    • Hayes DL, Holmes DR Jr, Gray JE. Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers. J Am Coll Cardiol 1987; 10:782-6.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 782-786
    • Hayes, D.L.1    Holmes Jr, D.R.2    Gray, J.E.3
  • 7
    • 25844474128 scopus 로고    scopus 로고
    • Safe, sensible, sagacious: responsible scanning of pacemaker patients
    • Gimbel JR, Wilkoff BL, Kanal E, Rozner MA. Safe, sensible, sagacious: responsible scanning of pacemaker patients. Eur Heart J 2005; 26:1683-4.
    • (2005) Eur Heart J , vol.26 , pp. 1683-1684
    • Gimbel, J.R.1    Wilkoff, B.L.2    Kanal, E.3    Rozner, M.A.4
  • 9
    • 0029045783 scopus 로고
    • Effects of nuclear magnetic resonance imaging on cardiac pacemakers
    • Lauck G, von Smekal A, Wolke S et al. Effects of nuclear magnetic resonance imaging on cardiac pacemakers. Pacing Clin Electrophysiol 1995; 18:1549-55.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 1549-1555
    • Lauck, G.1    von Smekal, A.2    Wolke, S.3
  • 10
    • 33748752144 scopus 로고    scopus 로고
    • Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in nonpacemaker-dependent patients: a prospective study with 115 examinations
    • Sommer T, Naehle CP, Yang A et al. Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in nonpacemaker-dependent patients: a prospective study with 115 examinations. Circulation 2006; 114:1285-92.
    • (2006) Circulation , vol.114 , pp. 1285-1292
    • Sommer, T.1    Naehle, C.P.2    Yang, A.3
  • 11
    • 33748740922 scopus 로고    scopus 로고
    • Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla
    • Nazarian S, Roguin A, Zviman MM et al. Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla. Circulation 2006; 114:1277-84.
    • (2006) Circulation , vol.114 , pp. 1277-1284
    • Nazarian, S.1    Roguin, A.2    Zviman, M.M.3
  • 13
    • 0024244635 scopus 로고
    • Effects of extracorporeal shock wave lithotripsy on cardiac pacemakers and its safety in patients with implanted cardiac pacemakers
    • Cooper D, Wilkoff B, Masterson M et al. Effects of extracorporeal shock wave lithotripsy on cardiac pacemakers and its safety in patients with implanted cardiac pacemakers. Pacing Clin Electrophysiol 1988; 11:1607-16.
    • (1988) Pacing Clin Electrophysiol , vol.11 , pp. 1607-1616
    • Cooper, D.1    Wilkoff, B.2    Masterson, M.3
  • 14
    • 0023947355 scopus 로고
    • Can transcutaneous electrical nerve stimulation be safely used in patients with permanent cardiac pacemakers?
    • Rasmussen MJ, Hayes DL, Vlietstra RE, Thorsteinsson G. Can transcutaneous electrical nerve stimulation be safely used in patients with permanent cardiac pacemakers? Mayo Clin Proc 1988; 63:443-5.
    • (1988) Mayo Clin Proc , vol.63 , pp. 443-445
    • Rasmussen, M.J.1    Hayes, D.L.2    Vlietstra, R.E.3    Thorsteinsson, G.4
  • 15
    • 0027166271 scopus 로고
    • Inadvertent suppression of a fixed rate ventricular pacemaker using a peripheral nerve stimulator
    • O'Flaherty D, Wardill M, Adams AP. Inadvertent suppression of a fixed rate ventricular pacemaker using a peripheral nerve stimulator. Anaesthesia 1993; 48:687-9.
    • (1993) Anaesthesia , vol.48 , pp. 687-689
    • O'Flaherty, D.1    Wardill, M.2    Adams, A.P.3
  • 16
    • 0025058821 scopus 로고
    • Cardiac pacemaker inhibition by transcutaneous electrical nerve stimulation
    • Chen D, Philip M, Philip PA, Monga TN. Cardiac pacemaker inhibition by transcutaneous electrical nerve stimulation. Arch Phys Med Rehabil 1990; 71:27-30.
    • (1990) Arch Phys Med Rehabil , vol.71 , pp. 27-30
    • Chen, D.1    Philip, M.2    Philip, P.A.3    Monga, T.N.4
  • 17
    • 0025058821 scopus 로고
    • Cardiac pacemaker inhibition by transcutaneous electrical nerve stimulation
    • Chen D, Philip M, Philip PA, Monga TN. Cardiac pacemaker inhibition by transcutaneous electrical nerve stimulation. Arch Phys Med Rehabil 1990; 71:27-30.
    • (1990) Arch Phys Med Rehabil , vol.71 , pp. 27-30
    • Chen, D.1    Philip, M.2    Philip, P.A.3    Monga, T.N.4
  • 18
    • 0037247985 scopus 로고    scopus 로고
    • The simultaneous use of a biventricular implantable cardioverter defibrillator (ICD) and transcutaneous electrical nerve stimulation (TENS) unit: implications for device interaction
    • Pyatt JR, Trenbath D, Chester M, Connelly DT. The simultaneous use of a biventricular implantable cardioverter defibrillator (ICD) and transcutaneous electrical nerve stimulation (TENS) unit: implications for device interaction. Europace 2003; 5:91-9.
    • (2003) Europace , vol.5 , pp. 91-99
    • Pyatt, J.R.1    Trenbath, D.2    Chester, M.3    Connelly, D.T.4
  • 19
    • 0031682609 scopus 로고    scopus 로고
    • Inappropriate shocks delivered by an ICD as a result of sensed potentials from a transcutaneous electronic nerve stimulation unit
    • Philbin DM, Marieb MA, Aithal KH, Schoenfeld MH. Inappropriate shocks delivered by an ICD as a result of sensed potentials from a transcutaneous electronic nerve stimulation unit. Pacing Clin Electrophysiol 1998; 21:2010-11.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 2010-2011
    • Philbin, D.M.1    Marieb, M.A.2    Aithal, K.H.3    Schoenfeld, M.H.4
  • 20
    • 34047229981 scopus 로고    scopus 로고
    • Safety of nerve conduction studies in patients with implanted cardiac devices
    • Schoeck AP, Mellion ML, Gilchrist JM, Christian FV. Safety of nerve conduction studies in patients with implanted cardiac devices. Muscle Nerve 2007; 35:521-4.
    • (2007) Muscle Nerve , vol.35 , pp. 521-524
    • Schoeck, A.P.1    Mellion, M.L.2    Gilchrist, J.M.3    Christian, F.V.4
  • 21
    • 33747356537 scopus 로고    scopus 로고
    • Safety of electronic apex locators and pulp testers in patients with implanted cardiac pacemakers or cardioverter/defibrillators
    • Wilson BL, Broberg C, Baumgartner JC, Harris C, Kron J. Safety of electronic apex locators and pulp testers in patients with implanted cardiac pacemakers or cardioverter/defibrillators. J Endod 2006; 32:847-52.
    • (2006) J Endod , vol.32 , pp. 847-852
    • Wilson, B.L.1    Broberg, C.2    Baumgartner, J.C.3    Harris, C.4    Kron, J.5
  • 22
    • 0034073825 scopus 로고    scopus 로고
    • Monitoring equipment induced tachycardia in patients with minute ventilation rate-responsive pacemakers
    • Southorn PA, Kamath GS, Vasdev GM, Hayes DL. Monitoring equipment induced tachycardia in patients with minute ventilation rate-responsive pacemakers. Br J Anaesth 2000; 84:508-9.
    • (2000) Br J Anaesth , vol.84 , pp. 508-509
    • Southorn, P.A.1    Kamath, G.S.2    Vasdev, G.M.3    Hayes, D.L.4
  • 23
    • 0034073825 scopus 로고    scopus 로고
    • Monitoring equipment induced tachycardia in patients with minute ventilation rate-responsive pacemakers
    • Southorn PA, Kamath GS, Vasdev GM, Hayes DL. Monitoring equipment induced tachycardia in patients with minute ventilation rate-responsive pacemakers. Br J Anaesth 2000; 84:508-9.
    • (2000) Br J Anaesth , vol.84 , pp. 508-509
    • Southorn, P.A.1    Kamath, G.S.2    Vasdev, G.M.3    Hayes, D.L.4
  • 24
    • 84889461164 scopus 로고    scopus 로고
    • Interaction between minute ventilation rate-adaptive pacemakers and cardiac monitoring and diagnostic equipment (10-14-98). Safety alerts, public health advisories, and notices from Center for Devices and Radiological Health
    • Federal Drug Administration. Retrieved January 13, 2000, from the World Wide Web
    • Burlington DB. Interaction between minute ventilation rate-adaptive pacemakers and cardiac monitoring and diagnostic equipment (10-14-98). Safety alerts, public health advisories, and notices from Center for Devices and Radiological Health, Federal Drug Administration. Retrieved January 13, 2000, from the World Wide Web: http://www.fda.gov/cdrh/safety.html
    • Burlington, D.B.1
  • 25
    • 13844307290 scopus 로고    scopus 로고
    • Electromagnetic interference with implantable cardiac pacemakers by video capsule
    • Dubner S, Dubner Y, Gallino S et al. Electromagnetic interference with implantable cardiac pacemakers by video capsule. Gastrointest Endosc 2005; 61:250-4.
    • (2005) Gastrointest Endosc , vol.61 , pp. 250-254
    • Dubner, S.1    Dubner, Y.2    Gallino, S.3
  • 26
    • 0030631502 scopus 로고    scopus 로고
    • Summary of measured radiofrequency electric and magnetic fields (10 kHz to 30 GHz) in the general and work environment
    • Mantiply ED, Pohl KR, Poppell SW, Murphy JA. Summary of measured radiofrequency electric and magnetic fields (10 kHz to 30 GHz) in the general and work environment. Bioelectromagnetics 1997; 18:563-77.
    • (1997) Bioelectromagnetics , vol.18 , pp. 563-577
    • Mantiply, E.D.1    Pohl, K.R.2    Poppell, S.W.3    Murphy, J.A.4
  • 27
    • 0026499215 scopus 로고
    • Testing of work environments for electromagnetic interference
    • Marco D, Eisinger G, Hayes DL. Testing of work environments for electromagnetic interference. Pacing Clin Electrophysiol 1992; 15:2016-22.
    • (1992) Pacing Clin Electrophysiol , vol.15 , pp. 2016-2022
    • Marco, D.1    Eisinger, G.2    Hayes, D.L.3
  • 28
    • 0029026109 scopus 로고
    • Erroneous discharge of an implantable cardioverter defibrillator caused by an electric razor
    • Seifert T, Block M, Borggrefe M, Breithardt G. Erroneous discharge of an implantable cardioverter defibrillator caused by an electric razor. Pacing Clin Electrophysiol 1995; 18:1592-4.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 1592-1594
    • Seifert, T.1    Block, M.2    Borggrefe, M.3    Breithardt, G.4
  • 29
    • 0027268074 scopus 로고
    • Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator
    • Man KC, Davidson T, Langberg JJ, Morady F, Kalbfleisch SJ. Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator. Pacing Clin Electrophysiol 1993; 16:1756-8.
    • (1993) Pacing Clin Electrophysiol , vol.16 , pp. 1756-1758
    • Man, K.C.1    Davidson, T.2    Langberg, J.J.3    Morady, F.4    Kalbfleisch, S.J.5
  • 30
    • 0025863574 scopus 로고
    • Implantable cardioverter defibrillator: possible hazards of electromagnetic interference
    • Schmitt C, Brachmann J, Waldecker B et al. Implantable cardioverter defibrillator: possible hazards of electromagnetic interference. Pacing Clin Electrophysiol 1991; 14:982-4.
    • (1991) Pacing Clin Electrophysiol , vol.14 , pp. 982-984
    • Schmitt, C.1    Brachmann, J.2    Waldecker, B.3
  • 31
    • 33745373010 scopus 로고    scopus 로고
    • Do induction cooktops interfere with cardiac pacemakers?
    • Irnich W, Bernstein AD. Do induction cooktops interfere with cardiac pacemakers? Europace 2006; 8:377-84.
    • (2006) Europace , vol.8 , pp. 377-384
    • Irnich, W.1    Bernstein, A.D.2
  • 32
    • 20544459227 scopus 로고    scopus 로고
    • Electromagnetic interference of implantable unipolar cardiac pacemakers by an induction oven
    • Hirose M, Hida M, Sato E, Kokubo K, Nie M, Kobayashi H. Electromagnetic interference of implantable unipolar cardiac pacemakers by an induction oven. PACE 2005; 28:540-8.
    • (2005) PACE , vol.28 , pp. 540-548
    • Hirose, M.1    Hida, M.2    Sato, E.3    Kokubo, K.4    Nie, M.5    Kobayashi, H.6
  • 33
    • 17044439549 scopus 로고    scopus 로고
    • Induction ovens and electromagnetic interference: what is the risk for patients with implantable cardioverter defibrillators?
    • Binggeli C, Rickli H, Ammann P et al. Induction ovens and electromagnetic interference: what is the risk for patients with implantable cardioverter defibrillators? J Cardiovasc Electrophysiol 2005; 16:399-401.
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 399-401
    • Binggeli, C.1    Rickli, H.2    Ammann, P.3
  • 34
    • 0037975740 scopus 로고    scopus 로고
    • Do airport metal detectors interfere with implantable pacemakers or cardioverter-defibrillators?
    • Kolb C, Schmieder S, Lehmann G et al. Do airport metal detectors interfere with implantable pacemakers or cardioverter-defibrillators? J Am Coll Cardiol 2003; 41:2054-9.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 2054-2059
    • Kolb, C.1    Schmieder, S.2    Lehmann, G.3
  • 35
    • 33847371983 scopus 로고    scopus 로고
    • Electronic article surveillance systems and interactions with implantable cardiac devices: risk of adverse interactions in public and commercial spaces
    • Gimbel JR, Cox JW Jr. Electronic article surveillance systems and interactions with implantable cardiac devices: risk of adverse interactions in public and commercial spaces. Mayo Clin Proc 2007; 82:318-22.
    • (2007) Mayo Clin Proc , vol.82 , pp. 318-322
    • Gimbel, J.R.1    Cox Jr, J.W.2
  • 36
    • 0031714598 scopus 로고    scopus 로고
    • Study of Pacemaker and Implantable Cardioverter Defibrillator Trig gering by Electronic Article Surveillance Devices (SPICED TEAS)
    • McIvor ME, Reddinger J, Floden E, Sheppard RC. Study of Pacemaker and Implantable Cardioverter Defibrillator Trig gering by Electronic Article Surveillance Devices (SPICED TEAS). Pacing Clin Electrophysiol 1998; 21:1847-61.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 1847-1861
    • McIvor, M.E.1    Reddinger, J.2    Floden, E.3    Sheppard, R.C.4
  • 37
    • 0033609514 scopus 로고    scopus 로고
    • Interactions between electronic article surveillance systems and implantable cardioverter-defibrillators
    • Groh WJ, Boschee SA, Engelstein ED et al. Interactions between electronic article surveillance systems and implantable cardioverter-defibrillators. Circulation 1999; 100:387-92.
    • (1999) Circulation , vol.100 , pp. 387-392
    • Groh, W.J.1    Boschee, S.A.2    Engelstein, E.D.3
  • 38
    • 0029796026 scopus 로고    scopus 로고
    • State of the science: pacemaker and defibrillator interference from wireless communication devices
    • Hayes DL, Carrillo RG, Findlay GK, Embrey M. State of the science: pacemaker and defibrillator interference from wireless communication devices. Pacing Clin Electrophysiol 1996; 19:1419-30.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 1419-1430
    • Hayes, D.L.1    Carrillo, R.G.2    Findlay, G.K.3    Embrey, M.4
  • 41
    • 0030925632 scopus 로고    scopus 로고
    • Interference with cardiac pacemakers by cellular telephones
    • Hayes DL, Wang PJ, Reynolds DW et al. Interference with cardiac pacemakers by cellular telephones. N Engl J Med 1997; 336:1473-9.
    • (1997) N Engl J Med , vol.336 , pp. 1473-1479
    • Hayes, D.L.1    Wang, P.J.2    Reynolds, D.W.3
  • 42
    • 0031254219 scopus 로고    scopus 로고
    • The absence of interference between GSM mobile telephones and implantable defibrillators: an in-vivo study. Groupe Systemes Mobiles [Spanish]
    • Sanmartin M, Fernandez Lozano I, Marquez J et al. The absence of interference between GSM mobile telephones and implantable defibrillators: an in-vivo study. Groupe Systemes Mobiles [Spanish]. Rev Esp Cardiol 1997; 50:715-19.
    • (1997) Rev Esp Cardiol , vol.50 , pp. 715-719
    • Sanmartin, M.1    Fernandez Lozano, I.2    Marquez, J.3
  • 43
    • 0032030838 scopus 로고    scopus 로고
    • Digital cellular telephone interaction with implantable cardioverter-defibrillators
    • Fetter JG, Ivans V, Benditt DG, Collins J. Digital cellular telephone interaction with implantable cardioverter-defibrillators. J Am Coll Cardiol 1998; 31:623-8.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 623-628
    • Fetter, J.G.1    Ivans, V.2    Benditt, D.G.3    Collins, J.4
  • 44
    • 33644790159 scopus 로고    scopus 로고
    • Effects of mobile telephones on the function of implantable cardioverter defibrillators
    • Tandogan I, Ozin B, Bozbas H et al. Effects of mobile telephones on the function of implantable cardioverter defibrillators. Ann Noninvasive Electrocardiol 2005; 10:409-13.
    • (2005) Ann Noninvasive Electrocardiol , vol.10 , pp. 409-413
    • Tandogan, I.1    Ozin, B.2    Bozbas, H.3
  • 45
    • 31644435757 scopus 로고    scopus 로고
    • Does high-power computed tomography scanning equipment affect the operation of pacemakers?
    • Yamaji S, Imai S, Saito F, Yagi H, Kushiro T, Uchiyama T. Does high-power computed tomography scanning equipment affect the operation of pacemakers? Circ J 2006; 70:190-7.
    • (2006) Circ J , vol.70 , pp. 190-197
    • Yamaji, S.1    Imai, S.2    Saito, F.3    Yagi, H.4    Kushiro, T.5    Uchiyama, T.6
  • 48
    • 0031984219 scopus 로고    scopus 로고
    • Radiotherapy in patients with cardiac pacemakers
    • Last A. Radiotherapy in patients with cardiac pacemakers. Br J Radiol 1998; 71:4-10.
    • (1998) Br J Radiol , vol.71 , pp. 4-10
    • Last, A.1
  • 52
    • 0842284661 scopus 로고    scopus 로고
    • Radiation therapy-induced electrical reset of an implantable cardioverter defibrillator device located outside the irradiation field
    • Thomas D, Becker R, Katus HA, Schoels W, Karle CA. Radiation therapy-induced electrical reset of an implantable cardioverter defibrillator device located outside the irradiation field. J Electrocardiol 2004; 37:73-4.
    • (2004) J Electrocardiol , vol.37 , pp. 73-74
    • Thomas, D.1    Becker, R.2    Katus, H.A.3    Schoels, W.4    Karle, C.A.5
  • 53
    • 29344435313 scopus 로고    scopus 로고
    • Cancer radiotherapy equipment as a cause of soft-errors in electronic equipment
    • IEEE05CH37616 43rd Annual International Reliability Physics Symposium, San Jose, CA
    • Wilkinson JD, Bounds J, Brown T, Gerbi B, Peltier J. Cancer radiotherapy equipment as a cause of soft-errors in electronic equipment. IEEE05CH37616 43rd Annual International Reliability Physics Symposium, San Jose, CA, 2005.
    • (2005)
    • Wilkinson, J.D.1    Bounds, J.2    Brown, T.3    Gerbi, B.4    Peltier, J.5
  • 54
    • 0027976720 scopus 로고
    • Management of radiation oncology patients with implanted cardiac pace makers: report of AAPM Task Group No 34.
    • Marbach JR, Sontag MR, Van Dyk J, Wolbarst AB. Management of radiation oncology patients with implanted cardiac pace makers: report of AAPM Task Group No. 34. Med Phys 1994; 21:85-90.
    • (1994) Med Phys , vol.21 , pp. 85-90
    • Marbach, J.R.1    Sontag, M.R.2    Van Dyk, J.3    Wolbarst, A.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.