Safety of nerve conduction studies in patients with implanted cardiac devices

Author keywords

Defibrillator; Intracardiac leads; Nerve conduction study; Pacemaker; Safety

Indexed keywords

ARTICLE; ARTIFICIAL HEART PACEMAKER; CLINICAL ARTICLE; DEFIBRILLATOR; DEVICE; ELECTROCARDIOGRAPHY MONITORING; ELECTRODIAGNOSIS; ELECTROGRAPHY; HUMAN; NERVE CONDUCTION; NERVE STIMULATION; PATIENT SAFETY; PRIORITY JOURNAL;

EID: 34047229981     PISSN: 0148639X     EISSN: 10974598     Source Type: Journal    
DOI: 10.1002/mus.20690     Document Type: Article
Times cited : (43)

References (6)
  • 1
    • 84966350153 scopus 로고    scopus 로고
    • Electrodiagnosis in diseases of nerve and muscle
    • 3rd ed. New York: Oxford University Press;
    • Kimura J. Electrodiagnosis in diseases of nerve and muscle. Principles and practice, 3rd ed. New York: Oxford University Press; 2001, p 93.
    • (2001) Principles and practice , pp. 93
    • Kimura, J.1
  • 2
    • 0023947904 scopus 로고
    • Peripheral nerve conduction stimulation: Its effect on cardiac pacemakers
    • LaBan MM, Petty D, Hauser AM, Taylor RS. Peripheral nerve conduction stimulation: its effect on cardiac pacemakers. Arch Phys Med Rehabil 1988;69:358-362.
    • (1988) Arch Phys Med Rehabil , vol.69 , pp. 358-362
    • LaBan, M.M.1    Petty, D.2    Hauser, A.M.3    Taylor, R.S.4
  • 4
    • 0029835029 scopus 로고    scopus 로고
    • American Association of Electrodiagnostic Medicine guidelines in electrodiagnostic medicine: Implanted cardioverters and defibrillators
    • Nora LM. American Association of Electrodiagnostic Medicine guidelines in electrodiagnostic medicine: implanted cardioverters and defibrillators. Muscle Nerve 1996;19:1359-1360.
    • (1996) Muscle Nerve , vol.19 , pp. 1359-1360
    • Nora, L.M.1
  • 5
    • 0027166271 scopus 로고
    • Pacemaker failure and peripheral nerve stimulation
    • O'Flaherty D, Adams AP. Pacemaker failure and peripheral nerve stimulation. Anaesthesia 1993;48:687-689.
    • (1993) Anaesthesia , vol.48 , pp. 687-689
    • O'Flaherty, D.1    Adams, A.P.2
  • 6
    • 0018168976 scopus 로고
    • Malfunction of a demand pacemaker caused by phrenic nerve stimulation
    • Wicks JM, Davison R, Belic N. Malfunction of a demand pacemaker caused by phrenic nerve stimulation. Chest 1978;74:303-305.
    • (1978) Chest , vol.74 , pp. 303-305
    • Wicks, J.M.1    Davison, R.2    Belic, N.3