메뉴 건너뛰기




Volumn 7, Issue 5, 2013, Pages 660-673

A 0.18 μ m biosensor front-end based on 1/f noise, distortion cancelation and chopper stabilization techniques

Author keywords

1 f noise; chopping; current mode electrochemical biosensor; distortion canceling; low noise; low power; noise canceling; strong inversion; transimpedance front end (read out); weak inversion

Indexed keywords

1/ F NOISE; CHOPPING; ELECTROCHEMICAL BIOSENSOR; LOW NOISE; LOW POWER; NOISE CANCELING; STRONG INVERSION; TRANSIMPEDANCE; WEAK INVERSIONS;

EID: 84887426373     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2012.2234121     Document Type: Article
Times cited : (19)

References (26)
  • 1
    • 77749327015 scopus 로고    scopus 로고
    • Amperometric electrochemical microsystem for a miniaturized protein biosensor array
    • Jun
    • C. Yang, Y. Huang, B. L. Hassler, R. M. Worden, and A. J. Mason, "Amperometric electrochemical microsystem for a miniaturized protein biosensor array," IEEE Trans. Biomed. Circuits Syst., vol. 3, no. 3, pp. 160-168, Jun. 2009.
    • (2009) IEEE Trans. Biomed. Circuits Syst. , vol.3 , Issue.3 , pp. 160-168
    • Yang, C.1    Huang, Y.2    Hassler, B.L.3    Worden, R.M.4    Mason, A.J.5
  • 2
    • 77955091787 scopus 로고    scopus 로고
    • Awireless-implantable microsystem for continuous blood glucose monitoring
    • Jun
    • M. M. Ahmadi and G. A. Jullien, "Awireless-implantable microsystem for continuous blood glucose monitoring," IEEE Trans. Biomed. Circuits Syst., vol. 3, no. 3, pp. 169-180, Jun. 2009.
    • (2009) IEEE Trans. Biomed. Circuits Syst. , vol.3 , Issue.3 , pp. 169-180
    • Ahmadi, M.M.1    Jullien, G.A.2
  • 4
    • 0022735625 scopus 로고
    • A CMOS potentiostat for amperometric chemical sensors
    • Jun
    • R. F. B. Turner, D. J. Harrison, and D. H. P. Baltes, "A CMOS potentiostat for amperometric chemical sensors," IEEE J. Solid-State Circuits, vol. 22, no. 3, pp. 473-478, Jun. 1987.
    • (1987) IEEE J. Solid-State Circuits , vol.22 , Issue.3 , pp. 473-478
    • Turner, R.F.B.1    Harrison, D.J.2    Baltes, D.H.P.3
  • 5
    • 33645163858 scopus 로고    scopus 로고
    • VLSI potentiostat for amperometric measurements for electrolytic reactions
    • Apr
    • H. S. Narula and J. G. Harris, "VLSI potentiostat for amperometric measurements for electrolytic reactions," IEEE J. Sensors, vol. 6, no. 2, pp. 239-247, Apr. 2006.
    • (2006) IEEE J. Sensors , vol.6 , Issue.2 , pp. 239-247
    • Narula, H.S.1    Harris, J.G.2
  • 7
    • 0030286542 scopus 로고    scopus 로고
    • Circuit techniques for reducing the effects of Op-Amp imperfections: Autozeroing, correlated double sampling, and chopper stabilization
    • PII S0018921996086902
    • C. C. Enz and G. C. Temes, "Circuit techniques for reducing the effects of op-amp imperfections: Autozeroing, correlated double sampling, and chopper stabilization," Proc. IEEE, pp. 1584-1614, Nov. 1996. (Pubitemid 126752607)
    • (1996) Proceedings of the IEEE , vol.84 , Issue.11 , pp. 1584-1614
    • Enz, C.C.1    Temes, G.C.2
  • 9
    • 48849089317 scopus 로고    scopus 로고
    • Active CMOS sensor array for electrochemical biomolecular detection
    • Aug
    • P. M. Levine, P. Gong, R. Levicky, and K. L. Shepard, "Active CMOS sensor array for electrochemical biomolecular detection," IEEE J. Solid-State Circuits, vol. 43, no. 8, pp. 1859-1871, Aug. 2008.
    • (2008) IEEE J. Solid-State Circuits , vol.43 , Issue.8 , pp. 1859-1871
    • Levine, P.M.1    Gong, P.2    Levicky, R.3    Shepard, K.L.4
  • 10
    • 34247325582 scopus 로고    scopus 로고
    • A 60 μW 60 nV/√Hz readout front-end for portable biopotential acquisition systems
    • DOI 10.1109/JSSC.2007.894804
    • R. F. Yazicioglu, P. Merken, R. Puers, and C. Van Hoof, "A 60 60 nV/Hz readout front-end for portable biopotential acquisition systems," IEEE J. Solid-State Circuits, vol. 42, no. 5, pp. 1100-1110, May 2007. (Pubitemid 46645027)
    • (2007) IEEE Journal of Solid-State Circuits , vol.42 , Issue.5 , pp. 1100-1110
    • Yazicioglu, R.F.1    Merken, P.2    Puers, R.3    Van Hoof, C.4
  • 11
    • 51949105156 scopus 로고    scopus 로고
    • A 2 100 nV/rtHz chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials
    • Dec
    • T. Denison, K. Consoer, W. Santa, A. Avestruz, J. Cooley, and A. Kelly, "A 2 100 nV/rtHz chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials," IEEE J. Solid-State Circuits, vol. 42, no. 12, pp. 2934-2945, Dec. 2007.
    • (2007) IEEE J. Solid-State Circuits , vol.42 , Issue.12 , pp. 2934-2945
    • Denison, T.1    Consoer, K.2    Santa, W.3    Avestruz, A.4    Cooley, J.5    Kelly, A.6
  • 12
    • 82155196432 scopus 로고    scopus 로고
    • A current-feedback instrumentation amplifier with a gain error reduction loop and 0. 06% untrimmed gain error
    • Dec
    • R. Wu, J. H. Huijsing, and K. A. A. Makinwa, "A current-feedback instrumentation amplifier with a gain error reduction loop and 0. 06% untrimmed gain error," IEEE J. Solid-State Circuits, vol. 46, no. 12, pp. 2794-2806, Dec. 2011.
    • (2011) IEEE J. Solid-State Circuits , vol.46 , Issue.12 , pp. 2794-2806
    • Wu, R.1    Huijsing, J.H.2    Makinwa, K.A.A.3
  • 13
    • 36348949860 scopus 로고    scopus 로고
    • A low-power, compact, adaptive logarithmic transimpedance amplifier operating over seven decades of current
    • DOI 10.1109/TCSI.2007.905657
    • A. Basu, R. W. Robucci, and P. E. Hasler, "A low-power, compact, adaptive logarithmic transimpedance amplifier operating over seven decades of current," IEEE Trans. Circuits and Syst. I, Reg. Papers, vol. 54, no. 14, pp. 2167-2177, Oct. 2007. (Pubitemid 350141864)
    • (2007) IEEE Transactions on Circuits and Systems I: Regular Papers , vol.54 , Issue.10 , pp. 2167-2177
    • Basu, A.1    Robucci, R.W.2    Hasler, P.E.3
  • 14
    • 84866615995 scopus 로고    scopus 로고
    • Noise canceling chopper stabilized front-end for electrochemical biosensors with improved dynamic range
    • May
    • V. Balasubramanian, P. F. Ruedi, and C. C. Enz, "Noise canceling chopper stabilized front-end for electrochemical biosensors with improved dynamic range," in Proc. IEEE Int. Symp. Circuits and Syst., May 2012, pp. 2215-2218.
    • (2012) Proc. IEEE Int. Symp. Circuits and Syst. , pp. 2215-2218
    • Balasubramanian, V.1    Ruedi, P.F.2    Enz, C.C.3
  • 15
    • 0035392547 scopus 로고    scopus 로고
    • Generating all two-MOS-transistor amplifiers leads to new wide-band LNAs
    • DOI 10.1109/4.933458, PII S0018920001045152
    • F. Bruccoleri, E. A. M. Klumperink, and B. Nauta, "Generating all two-MOS-transistor amplifier leads to new wide-band LNAs," IEEE J. Solid-State Circuits, vol. 36, no. 7, pp. 1032-1040, Jul. 2001. (Pubitemid 32732788)
    • (2001) IEEE Journal of Solid-State Circuits , vol.36 , Issue.7 , pp. 1032-1040
    • Bruccoleri, F.1    Klumperink, E.A.M.2    Nauta, B.3
  • 16
    • 1242330899 scopus 로고    scopus 로고
    • Wide-band CMOS low-noise amplifier exploiting thermal noise canceling
    • Feb
    • F. Bruccoleri,E. A. M. Klumperink, and B. Nauta, "Wide-band CMOS low-noise amplifier exploiting thermal noise canceling," IEEE J. Solid-State Circuits, vol. 39, no. 2, pp. 275-282, Feb. 2004.
    • (2004) IEEE J. Solid-State Circuits , vol.39 , Issue.2 , pp. 275-282
    • Bruccoleri, F.1    Klumperink, E.A.M.2    Nauta, B.3
  • 17
    • 44649186833 scopus 로고    scopus 로고
    • Wideband balun-LNA with simultaneous output balancing, noise-canceling and distortion-canceling
    • Jun
    • S. C. Blaakmeer, E. A. M. Klumperink, D. M. W. Leenaerts, and B. Nauta, "Wideband balun-LNA with simultaneous output balancing, noise-canceling and distortion-canceling," IEEE J. Solid-State Circuits, vol. 43, no. 6, pp. 1341-1350, Jun. 2008.
    • (2008) IEEE J. Solid-State Circuits , vol.43 , Issue.6 , pp. 1341-1350
    • Blaakmeer, S.C.1    Klumperink, E.A.M.2    Leenaerts, D.M.W.3    Nauta, B.4
  • 20
    • 0038718680 scopus 로고    scopus 로고
    • A low-power low-noise CMOS amplifier for neural recording applications
    • Jun
    • R. R. Harrison and C. Charles, "A low-power low-noise CMOS amplifier for neural recording applications," IEEE J. Solid-State Circuits, vol. 38, no. 6, pp. 958-965, Jun. 2003.
    • (2003) IEEE J. Solid-State Circuits , vol.38 , Issue.6 , pp. 958-965
    • Harrison, R.R.1    Charles, C.2
  • 24
    • 79951916369 scopus 로고    scopus 로고
    • Robust microelectrodes developed for improved stability in electrochemical characterization of biomolecular layers
    • Nov
    • Y. Temiz, A. Ferretti, E. Accastelli, Y. Leblebici, and C. Guiducci, "Robust microelectrodes developed for improved stability in electrochemical characterization of biomolecular layers," IEEE Sensors, pp. 1051-1055, Nov. 2010.
    • (2010) IEEE Sensors , pp. 1051-1055
    • Temiz, Y.1    Ferretti, A.2    Accastelli, E.3    Leblebici, Y.4    Guiducci, C.5
  • 26
    • 0023561471 scopus 로고
    • A micropower low-noise monolithic instrumentation amplifier for medical purposes
    • Dec
    • M. S. J. Steyaert,W. M. C. Sansen, and C. Zhongyuan, "A micropower low-noise monolithic instrumentation amplifier for medical purposes," IEEE J. Solid-State Circuits, vol. sc-22, no. 6, pp. 1163-1168, Dec. 1987.
    • (1987) IEEE J. Solid-State Circuits , vol.SC-22 , Issue.6 , pp. 1163-1168
    • Steyaert, M.S.J.1    Sansen, W.M.C.2    Zhongyuan, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.