Volumn 10, Issue 11, 2013, Pages 840-846

CT scan parameters and radiation dose: Practical advice for radiologists

Author keywords

automated tube current modulation; iterative reconstruction; low kVp; pitch; Radiation dose

Indexed keywords

ANTENNA; ARTICLE; COLLIMATOR; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST TO NOISE RATIO; DETECTOR CONFIGURATION; HUMAN; IMAGE QUALITY; IMAGING SOFTWARE; MULTIDETECTOR COMPUTED TOMOGRAPHY; NOISE; PATIENT POSITIONING; PITCH; RADIATION DOSE; RADIOLOGICAL PARAMETERS; RADIOLOGIST; RECONSTRUCTED SLICE THICKNESS; SCAN RANGE; TUBE; TUBE CURRENT; TUBE POTENTIAL;

EID: 84887209131     PISSN: 15461440     EISSN: 1558349X     Source Type: Journal    
DOI: 10.1016/j.jacr.2013.05.032     Document Type: Article
Times cited : (103)

References (36)
  • 1
    • 84928096212 scopus 로고    scopus 로고
    • CT dose reduction applications: Available tools on the latest generation of CT scanners
    • S.P. Raman, P.T. Johnson, S. Deshmukh CT dose reduction applications: available tools on the latest generation of CT scanners J Am Coll Radiol 10 2013 37 41
    • (2013) J Am Coll Radiol , vol.10 , pp. 37-41
    • Raman, S.P.1    Johnson, P.T.2    Deshmukh, S.3
  • 2
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • D.J. Brenner, E.J. Hall Computed tomography - an increasing source of radiation exposure N Engl J Med 357 2007 2277 2284 (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 3
    • 7044271152 scopus 로고    scopus 로고
    • Multi-detector row CT: Principles and practice for abdominal applications
    • DOI 10.1148/radiol.2332030994
    • S. Saini Multi-detector row CT: principles and practice for abdominal applications Radiology 233 2004 323 327 (Pubitemid 39423787)
    • (2004) Radiology , vol.233 , Issue.2 , pp. 323-327
    • Saini, S.1
  • 6
    • 0037372750 scopus 로고    scopus 로고
    • Multi-detector row CT: Radiation dose characteristics
    • DOI 10.1148/radiol.2263020205
    • L.M. Hamberg, J.T. Rhea, G.J. Hunter Multi-detector row CT: radiation dose characteristics Radiology 226 2003 762 772 (Pubitemid 36259153)
    • (2003) Radiology , vol.226 , Issue.3 , pp. 762-772
    • Hamberg, L.M.1    Rhea, J.T.2    Hunter, G.J.3    Thrall, J.H.4
  • 7
  • 8
    • 84928096148 scopus 로고    scopus 로고
    • Automatic exposure control in CT: Applications and limitations
    • S. Singh, M.K. Kalra, J.H. Thrall Automatic exposure control in CT: applications and limitations J Am Coll Radiol 8 2011 446 449
    • (2011) J Am Coll Radiol , vol.8 , pp. 446-449
    • Singh, S.1    Kalra, M.K.2    Thrall, J.H.3
  • 9
    • 13244297711 scopus 로고    scopus 로고
    • Techniques and applications of automatic tube current modulation for CT
    • M. Kalra, M. Maher, T. Toth Techniques and applications of automatic tube current modulation for CT Radiology 233 2004 649 657
    • (2004) Radiology , vol.233 , pp. 649-657
    • Kalra, M.1    Maher, M.2    Toth, T.3
  • 10
    • 84926237417 scopus 로고    scopus 로고
    • CT dose reduction strategy: To modulate dose or not in certain patients?
    • M. Mahesh, E.K. Fishman CT dose reduction strategy: to modulate dose or not in certain patients? J Am Coll Radiol 9 2012 931 932
    • (2012) J Am Coll Radiol , vol.9 , pp. 931-932
    • Mahesh, M.1    Fishman, E.K.2
  • 11
    • 34249017237 scopus 로고    scopus 로고
    • Relationship between noise, dose, and pitch in cardiac multi-detector row CT
    • A.N. Primak, C.H. McCollough, M.R. Bruesewitz Relationship between noise, dose, and pitch in cardiac multi-detector row CT Radiographics 26 2006 1785 1794
    • (2006) Radiographics , vol.26 , pp. 1785-1794
    • Primak, A.N.1    McCollough, C.H.2    Bruesewitz, M.R.3
  • 12
    • 84864662302 scopus 로고    scopus 로고
    • Automated tube potential selection for standard chest and abdominal CT in follow-up patients with testicular cancer: Comparison with fixed tube potential
    • R. Gnannt, A. Winklehner, D. Eberli Automated tube potential selection for standard chest and abdominal CT in follow-up patients with testicular cancer: comparison with fixed tube potential Eur Radiol 22 2012 1937 1945
    • (2012) Eur Radiol , vol.22 , pp. 1937-1945
    • Gnannt, R.1    Winklehner, A.2    Eberli, D.3
  • 13
    • 85027936411 scopus 로고    scopus 로고
    • Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: Evaluation of image quality
    • J.F. Paul Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality Int J Cardiovasc Imaging 27 suppl 2011 53 59
    • (2011) Int J Cardiovasc Imaging , vol.27 , Issue.SUPPL. , pp. 53-59
    • Paul, J.F.1
  • 14
    • 77953872454 scopus 로고    scopus 로고
    • Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: A comparative study
    • G.M. Feuchtner, D. Jodocy, A. Klauser Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study Eur J Radiol 75 2010 e51 e56
    • (2010) Eur J Radiol , vol.75
    • Feuchtner, G.M.1    Jodocy, D.2    Klauser, A.3
  • 15
    • 84865594613 scopus 로고    scopus 로고
    • Optimization of kilovoltage and tube current-exposure time product based on abdominal circumference: An oval phantom study for pediatric abdominal CT
    • F. Dong, W. Davros, J. Pozzuto Optimization of kilovoltage and tube current-exposure time product based on abdominal circumference: an oval phantom study for pediatric abdominal CT AJR Am J Roentgenol 199 2012 670 676
    • (2012) AJR Am J Roentgenol , vol.199 , pp. 670-676
    • Dong, F.1    Davros, W.2    Pozzuto, J.3
  • 16
    • 84864373822 scopus 로고    scopus 로고
    • Achieving routine submillisievert CT scanning: Report from the summit on management of radiation dose in CT
    • C.H. McCollough, G.H. Chen, W. Kalender Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT Radiology 264 2012 567 580
    • (2012) Radiology , vol.264 , pp. 567-580
    • McCollough, C.H.1    Chen, G.H.2    Kalender, W.3
  • 17
    • 80055098779 scopus 로고    scopus 로고
    • SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
    • S.S. Halliburton, S. Abbara, M.Y. Chen SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT J Cardiovasc Comput Tomogr 5 2011 198 224
    • (2011) J Cardiovasc Comput Tomogr , vol.5 , pp. 198-224
    • Halliburton, S.S.1    Abbara, S.2    Chen, M.Y.3
  • 18
    • 79751531405 scopus 로고    scopus 로고
    • Computed tomography - Old ideas and new technology
    • D. Fleischmann, F.E. Boas Computed tomography - old ideas and new technology Eur Radiol 21 2011 510 517
    • (2011) Eur Radiol , vol.21 , pp. 510-517
    • Fleischmann, D.1    Boas, F.E.2
  • 19
    • 84864693212 scopus 로고    scopus 로고
    • Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults
    • G.S. Desai, R.N. Uppot, E.W. Yu Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults Eur Radiol 22 2012 1631 1640
    • (2012) Eur Radiol , vol.22 , pp. 1631-1640
    • Desai, G.S.1    Uppot, R.N.2    Yu, E.W.3
  • 20
    • 84857246260 scopus 로고    scopus 로고
    • Iterative reconstruction in head CT: Image quality of routine and low-dose protocols in comparison with standard filtered back-projection
    • A. Korn, M. Fenchel, B. Bender Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection AJNR Am J Neuroradiol 33 2012 218 224
    • (2012) AJNR Am J Neuroradiol , vol.33 , pp. 218-224
    • Korn, A.1    Fenchel, M.2    Bender, B.3
  • 21
    • 84857237267 scopus 로고    scopus 로고
    • Iterative reconstruction reduces abdominal CT dose
    • A.C. Martinsen, H.K. Saether, P.K. Hol Iterative reconstruction reduces abdominal CT dose Eur J Radiol 81 2012 1483 1487
    • (2012) Eur J Radiol , vol.81 , pp. 1483-1487
    • Martinsen, A.C.1    Saether, H.K.2    Hol, P.K.3
  • 22
    • 77956832667 scopus 로고    scopus 로고
    • Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: The ERASIR study
    • J. Leipsic, T.M. Labounty, B. Heilbron Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study AJR Am J Roentgenol 195 2010 655 660
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 655-660
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 23
    • 84860339698 scopus 로고    scopus 로고
    • CT enterography at 80 kVp with adaptive statistical iterative reconstruction versus at 120 kVp with standard reconstruction: Image quality, diagnostic adequacy, and dose reduction
    • R.K. Kaza, J.F. Platt, M.M. Al-Hawary CT enterography at 80 kVp with adaptive statistical iterative reconstruction versus at 120 kVp with standard reconstruction: image quality, diagnostic adequacy, and dose reduction AJR Am J Roentgenol 198 2012 1084 1092
    • (2012) AJR Am J Roentgenol , vol.198 , pp. 1084-1092
    • Kaza, R.K.1    Platt, J.F.2    Al-Hawary, M.M.3
  • 25
    • 84862170887 scopus 로고    scopus 로고
    • Impact of miscentering on patient dose and image noise in x-ray CT imaging: Phantom and clinical studies
    • M.A. Habibzadeh, M.R. Ay, A.R. Asl Impact of miscentering on patient dose and image noise in x-ray CT imaging: phantom and clinical studies Phys Med 28 2012 191 199
    • (2012) Phys Med , vol.28 , pp. 191-199
    • Habibzadeh, M.A.1    Ay, M.R.2    Asl, A.R.3
  • 26
    • 84878553949 scopus 로고    scopus 로고
    • Effect of vertical positioning on organ dose, image noise and contrast in pediatric chest CT-phantom study
    • T. Kaasalainen, K. Palmu, A. Lampinen Effect of vertical positioning on organ dose, image noise and contrast in pediatric chest CT-phantom study Pediatr Radiol 43 2013 673 684
    • (2013) Pediatr Radiol , vol.43 , pp. 673-684
    • Kaasalainen, T.1    Palmu, K.2    Lampinen, A.3
  • 27
    • 34347401255 scopus 로고    scopus 로고
    • The influence of patient centering on CT dose and image noise
    • DOI 10.1118/1.2748113
    • T. Toth, Z. Ge, M.P. Daly The influence of patient centering on CT dose and image noise Med Phys 34 2007 3093 3101 (Pubitemid 47019829)
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 3093-3101
    • Toth, T.1    Ge, Z.2    Daly, M.P.3
  • 28
    • 70449135326 scopus 로고    scopus 로고
    • Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning
    • J. Gudjonsdottir, J.R. Svensson, S. Campling Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning Acta Radiol 50 2009 1035 1041
    • (2009) Acta Radiol , vol.50 , pp. 1035-1041
    • Gudjonsdottir, J.1    Svensson, J.R.2    Campling, S.3
  • 30
    • 84858859655 scopus 로고    scopus 로고
    • Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: Comparison of beam pitch and detector coverage with 128-detector row CT
    • T. Shirasaka, Y. Funama, M. Hayashi Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT Radiol Phys Technol 5 2012 53 58
    • (2012) Radiol Phys Technol , vol.5 , pp. 53-58
    • Shirasaka, T.1    Funama, Y.2    Hayashi, M.3
  • 31
    • 74749092491 scopus 로고    scopus 로고
    • Dose reduction in helical CT: Dynamically adjustable z-axis X-ray beam collimation
    • J.A. Christner, V.A. Zavaletta, C.D. Eusemann Dose reduction in helical CT: dynamically adjustable z-axis X-ray beam collimation AJR Am J Roentgenol 194 2010 W49 W55
    • (2010) AJR Am J Roentgenol , vol.194
    • Christner, J.A.1    Zavaletta, V.A.2    Eusemann, C.D.3
  • 32
    • 34250823535 scopus 로고    scopus 로고
    • Impact of operator-selected image noise index and reconstruction slice thickness on patient radiation dose in 64-MDCT
    • DOI 10.2214/AJR.06.1524
    • K. Kanal, B. Stewart, O. Kolokythas Impact of operator-selected image noise index and reconstruction slice thickness on patient radiation dose in 64-MDCT AJR Am J Roentgenol 189 2007 219 225 (Pubitemid 46983214)
    • (2007) American Journal of Roentgenology , vol.189 , Issue.1 , pp. 219-225
    • Kanal, K.M.1    Stewart, B.K.2    Kolokythas, O.3    Shuman, W.P.4
  • 34
    • 0030472878 scopus 로고    scopus 로고
    • The effect of helical pitch and beam collimation on the lesion contrast and slice profile in helical CT imaging
    • DOI 10.1118/1.597774
    • H. Hu, S.H. Fox The effect of helical pitch and beam collimation on the lesion contrast and slice profile in helical CT imaging Med Phys 23 1996 1943 1954 (Pubitemid 27023692)
    • (1996) Medical Physics , vol.23 , Issue.12 , pp. 1943-1954
    • Hu, H.1    Fox, S.H.2
  • 35
    • 84870861055 scopus 로고    scopus 로고
    • Radiation dose and image quality at high-pitch CT angiography of the aorta: Intraindividual and interindividual comparisons with conventional CT angiography
    • P. Apfaltrer, E.L. Hanna, U.J. Schoepf Radiation dose and image quality at high-pitch CT angiography of the aorta: intraindividual and interindividual comparisons with conventional CT angiography AJR Am J Roentgenol 199 2012 1402 1409
    • (2012) AJR Am J Roentgenol , vol.199 , pp. 1402-1409
    • Apfaltrer, P.1    Hanna, E.L.2    Schoepf, U.J.3
  • 36
    • 84879690002 scopus 로고    scopus 로고
    • High-pitch dual-source CT angiography of supra-aortic arteries: Assessment of image quality and radiation dose
    • A. Korn, M. Fenchel, B. Bender High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose Neuroradiology 55 2013 423 430
    • (2013) Neuroradiology , vol.55 , pp. 423-430
    • Korn, A.1    Fenchel, M.2    Bender, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.