메뉴 건너뛰기




Volumn 21, Issue 3, 2011, Pages 510-517

Computed tomography-old ideas and new technology

Author keywords

Dual energy CT; Dual source CT; Gated cardiac CT; History of CT; Iterative reconstruction; Multidetector computed tomography (MDCT)

Indexed keywords

ANGIOCARDIOGRAPHY; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER ASSISTED EMISSION TOMOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; IMAGE QUALITY; IMAGING SYSTEM; MEDICAL TECHNOLOGY; MULTIDETECTOR COMPUTED TOMOGRAPHY; NUCLEAR MEDICINE; PRIORITY JOURNAL; RADIATION DOSE; REVIEW; X RAY TUBE;

EID: 79751531405     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-011-2056-z     Document Type: Review
Times cited : (242)

References (34)
  • 1
    • 0015580637 scopus 로고
    • Computerized transverse axial tomography
    • 1:STN:280:DyaE3s%2Fps1KqtQ%3D%3D 10.1259/0007-1285-46-552-1023 4686818
    • J Ambrose G Hounsfield 1973 Computerized transverse axial tomography Br J Radiol 46 148 149 1:STN:280:DyaE3s%2Fps1KqtQ%3D%3D 10.1259/0007-1285-46-552- 1023 4686818
    • (1973) Br J Radiol , vol.46 , pp. 148-149
    • Ambrose, J.1    Hounsfield, G.2
  • 2
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography). Part 1. Description of system
    • 1:STN:280:DyaE2c%2Fkt1Cjtw%3D%3D 10.1259/0007-1285-46-552-1016 4757352
    • GN Hounsfield 1973 Computerized transverse axial scanning (tomography). Part 1. Description of system Br J Radiol 46 1016 1022 1:STN:280: DyaE2c%2Fkt1Cjtw%3D%3D 10.1259/0007-1285-46-552-1016 4757352
    • (1973) Br J Radiol , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 3
    • 73149113560 scopus 로고    scopus 로고
    • Projected cancer risks from computed tomographic scans performed in the United States in 2007
    • 10.1001/archinternmed.2009.440 20008689
    • A Berrington de Gonzalez M Mahesh KP Kim, et al. 2009 Projected cancer risks from computed tomographic scans performed in the United States in 2007 Arch Intern Med 169 2071 2077 10.1001/archinternmed.2009.440 20008689
    • (2009) Arch Intern Med , vol.169 , pp. 2071-2077
    • Berrington De Gonzalez, A.1    Mahesh, M.2    Kim, K.P.3
  • 4
    • 0016068330 scopus 로고
    • The Fourier reconstruction of a head section
    • LA Shepp BF Logan 1974 The Fourier reconstruction of a head section IEEE Trans Nucl Sci NS21 21 34
    • (1974) IEEE Trans Nucl Sci , vol.21 , pp. 21-34
    • Shepp, L.A.1    Logan, B.F.2
  • 5
    • 0001169360 scopus 로고
    • Über die Bestimmung von Funktionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten
    • J Radon 1917 Über die Bestimmung von Funktionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten Berichte Sächsische Acadamie der Wissenschaften 69 262
    • (1917) Berichte Sächsische Acadamie der Wissenschaften , vol.69 , pp. 262
    • Radon, J.1
  • 6
    • 0016984643 scopus 로고
    • A maximum likelihood approach to emission image reconstruction from projections
    • 10.1109/TNS.1976.4328496
    • AJ Rockmore A Macovski 1976 A maximum likelihood approach to emission image reconstruction from projections IEEE Trans Nucl Sci 23 1428 1432 10.1109/TNS.1976.4328496
    • (1976) IEEE Trans Nucl Sci , vol.23 , pp. 1428-1432
    • Rockmore, A.J.1    MacOvski, A.2
  • 7
    • 79751538632 scopus 로고    scopus 로고
    • Evaluation of two new iterative techniques for reducing metal artifacts in computed tomography
    • in press
    • Boas FE, Fleischmann D (2011) Evaluation of two new iterative techniques for reducing metal artifacts in computed tomography. Radiology in press
    • (2011) Radiology
    • Boas, F.E.1    Fleischmann, D.2
  • 8
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience
    • 10.1148/radiol.09090094 20032149
    • D Marin RC Nelson ST Schindera, et al. 2010 Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience Radiology 254 145 153 10.1148/radiol. 09090094 20032149
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 10
    • 79751534189 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): Evaluation of image noise reduction in 32 patients
    • 10.1007/s00330-010-1990-5
    • F Pontana J Pagniez T Flohr, et al. 2010 Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients Eur Radiol 10.1007/s00330-010-1990-5
    • (2010) Eur Radiol
    • Pontana, F.1    Pagniez, J.2    Flohr, T.3
  • 11
    • 0017604036 scopus 로고
    • Gated computed tomography of the human heart
    • SS Sagel ES Weiss RG Gillard, et al. 1977 Gated computed tomography of the human heart Invest Radiol 12 563 566 1:STN:280:DyaE1c%2Fms1eitw%3D%3D 10.1097/00004424-197711000-00019 591261 (Pubitemid 8258547)
    • (1977) Investigative Radiology , vol.12 , Issue.6 , pp. 563-566
    • Sagel, S.S.1    Weiss, E.S.2    Gillard, R.G.3
  • 12
    • 0017740652 scopus 로고
    • Stop-action cardiac computed tomography
    • 1:STN:280:DyaE2s7kvFOjug%3D%3D 322209
    • GS Harell DF Guthaner RS Breiman, et al. 1977 Stop-action cardiac computed tomography Radiology 123 515 517 1:STN:280:DyaE2s7kvFOjug%3D%3D 322209
    • (1977) Radiology , vol.123 , pp. 515-517
    • Harell, G.S.1    Guthaner, D.F.2    Breiman, R.S.3
  • 13
    • 59649127716 scopus 로고    scopus 로고
    • Estimated radiation dose associated with cardiac CT angiography
    • 1:CAS:528:DC%2BD1MXhtlyksbk%3D 10.1001/jama.2009.54 19190314
    • J Hausleiter T Meyer F Hermann, et al. 2009 Estimated radiation dose associated with cardiac CT angiography JAMA 301 500 507 1:CAS:528: DC%2BD1MXhtlyksbk%3D 10.1001/jama.2009.54 19190314
    • (2009) JAMA , vol.301 , pp. 500-507
    • Hausleiter, J.1    Meyer, T.2    Hermann, F.3
  • 14
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    • 10.1148/radiol.2463070989 18195386
    • JP Earls EL Berman BA Urban, et al. 2008 Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose Radiology 246 742 753 10.1148/radiol.2463070989 18195386
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3
  • 16
    • 78149484685 scopus 로고    scopus 로고
    • Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): Performance studies
    • 10.1118/1.3460318 20879597
    • J Tang J Hsieh GH Chen 2010 Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies Med Phys 37 4377 4388 10.1118/1.3460318 20879597
    • (2010) Med Phys , vol.37 , pp. 4377-4388
    • Tang, J.1    Hsieh, J.2    Chen, G.H.3
  • 17
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    • DOI 10.1118/1.2836423
    • GH Chen J Tang S Leng 2008 Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets Med Phys 35 660 663 10.1118/1.2836423 18383687 (Pubitemid 351190885)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 660-663
    • Chen, G.-H.1    Tang, J.2    Leng, S.3
  • 20
    • 40049100060 scopus 로고    scopus 로고
    • An outlook on x-ray CT research and development
    • DOI 10.1118/1.2836950
    • G Wang H Yu B De Man 2008 An outlook on x-ray CT research and development Med Phys 35 1051 1064 10.1118/1.2836950 18404940 (Pubitemid 351322651)
    • (2008) Medical Physics , vol.35 , Issue.3 , pp. 1051-1064
    • Wang, G.1    Yu, H.2    De Man, B.3
  • 21
    • 0019125112 scopus 로고
    • Three-dimensional imaging of heart, lungs, and circulation
    • EL Ritman JH Kinsey RA Robb BK Gilbert LD Harris EH Wood 1980 Three-dimensional imaging of heart, lungs, and circulation Science 210 273 280 1:STN:280:DyaL3M%2FjtlOgsA%3D%3D 10.1126/science.7423187 7423187 (Pubitemid 11208461)
    • (1980) Science , vol.210 , Issue.4467 , pp. 273-280
    • Ritman, E.L.1    Kinsey, J.H.2    Robb, R.A.3
  • 23
    • 4644266911 scopus 로고    scopus 로고
    • New x-ray tube performance in computed tomography by introducing the rotating envelope tube technology
    • DOI 10.1118/1.1783552
    • P Schardt J Deuringer J Freudenberger, et al. 2004 New x-ray tube performance in computed tomography by introducing the rotating envelope tube technology Med Phys 31 2699 2706 10.1118/1.1783552 15487753 (Pubitemid 39287887)
    • (2004) Medical Physics , vol.31 , Issue.9 , pp. 2699-2706
    • Schardt, P.1    Deuringer, J.2    Freudenberger, J.3    Hell, E.4    Knupfer, W.5    Mattern, D.6    Schild, M.7
  • 24
    • 79751525771 scopus 로고
    • General Electric Company Patent No. 1215116, USA
    • Coolidge WD, General Electric Company (1917) X-ray apparatus. Patent No. 1215116, USA
    • (1917) X-ray Apparatus
    • Coolidge, W.D.1
  • 25
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in X-ray computerized tomography
    • 1:STN:280:DyaE2s%2FhtlOntg%3D%3D 10.1088/0031-9155/21/5/002 967922
    • RE Alvarez A Macovski 1976 Energy-selective reconstructions in X-ray computerized tomography Phys Med Biol 21 733 744 1:STN:280: DyaE2s%2FhtlOntg%3D%3D 10.1088/0031-9155/21/5/002 967922
    • (1976) Phys Med Biol , vol.21 , pp. 733-744
    • Alvarez, R.E.1    MacOvski, A.2
  • 26
    • 67649207868 scopus 로고    scopus 로고
    • Photon counting energy dispersive detector arrays for X-ray imaging
    • 10.1109/TNS.2009.2013709 19920884
    • JS Iwanczyk E Nygard O Meirav, et al. 2009 Photon counting energy dispersive detector arrays for X-ray imaging IEEE Trans Nucl Sci 56 535 542 10.1109/TNS.2009.2013709 19920884
    • (2009) IEEE Trans Nucl Sci , vol.56 , pp. 535-542
    • Iwanczyk, J.S.1    Nygard, E.2    Meirav, O.3
  • 27
    • 67049172574 scopus 로고    scopus 로고
    • Hypervascular liver tumors: Low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection-initial clinical experience
    • 10.1148/radiol.2513081330 19346514
    • D Marin RC Nelson E Samei, et al. 2009 Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection-initial clinical experience Radiology 251 771 779 10.1148/radiol.2513081330 19346514
    • (2009) Radiology , vol.251 , pp. 771-779
    • Marin, D.1    Nelson, R.C.2    Samei, E.3
  • 29
    • 56149119702 scopus 로고    scopus 로고
    • Abdominal aorta: Evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms-initial observations
    • 10.1148/radiol.2492080359 18812561
    • H Chandarana MC Godoy I Vlahos, et al. 2008 Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms-initial observations Radiology 249 692 700 10.1148/radiol.2492080359 18812561
    • (2008) Radiology , vol.249 , pp. 692-700
    • Chandarana, H.1    Godoy, M.C.2    Vlahos, I.3
  • 30
    • 56149116093 scopus 로고    scopus 로고
    • Endoleaks after endovascular abdominal aortic aneurysm repair: Detection with dual-energy dual-source CT
    • 10.1148/radiol.2483080193 18780822
    • P Stolzmann T Frauenfelder T Pfammatter, et al. 2008 Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT Radiology 249 682 691 10.1148/radiol.2483080193 18780822
    • (2008) Radiology , vol.249 , pp. 682-691
    • Stolzmann, P.1    Frauenfelder, T.2    Pfammatter, T.3
  • 31
    • 59249098264 scopus 로고    scopus 로고
    • Dual energy CT: Preliminary observations and potential clinical applications in the abdomen
    • 10.1007/s00330-008-1122-7 18677487
    • A Graser TR Johnson H Chandarana M Macari 2009 Dual energy CT: preliminary observations and potential clinical applications in the abdomen Eur Radiol 19 13 23 10.1007/s00330-008-1122-7 18677487
    • (2009) Eur Radiol , vol.19 , pp. 13-23
    • Graser, A.1    Johnson, T.R.2    Chandarana, H.3    MacAri, M.4
  • 32
    • 77950613338 scopus 로고    scopus 로고
    • Dual-energy CT as a potential new diagnostic tool in the management of gout in the acute setting
    • 10.2214/AJR.09.2428 20308513
    • S Nicolaou CJ Yong-Hing S Galea-Soler DJ Hou L Louis P Munk 2010 Dual-energy CT as a potential new diagnostic tool in the management of gout in the acute setting AJR Am J Roentgenol 194 1072 1078 10.2214/AJR.09.2428 20308513
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 1072-1078
    • Nicolaou, S.1    Yong-Hing, C.J.2    Galea-Soler, S.3    Hou, D.J.4    Louis, L.5    Munk, P.6
  • 33
    • 58049200258 scopus 로고    scopus 로고
    • Dual-energy CT discrimination of iodine and calcium: Experimental results and implications for lower extremity CT angiography
    • 10.1016/j.acra.2008.09.004 19124101
    • DN Tran M Straka JE Roos S Napel D Fleischmann 2009 Dual-energy CT discrimination of iodine and calcium: experimental results and implications for lower extremity CT angiography Acad Radiol 16 160 171 10.1016/j.acra.2008.09.004 19124101
    • (2009) Acad Radiol , vol.16 , pp. 160-171
    • Tran, D.N.1    Straka, M.2    Roos, J.E.3    Napel, S.4    Fleischmann, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.