메뉴 건너뛰기




Volumn 5, Issue 1, 2012, Pages 53-58

Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: Comparison of beam pitch and detector coverage with 128-detector row CT

Author keywords

128 Detector row CT; Beam pitch; Detector coverage; Over range area; Spiral dynamic z collimator; Unnecessary dose

Indexed keywords

ARTICLE; COLLIMATOR; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DOSIMETER; INTERMETHOD COMPARISON; PRIORITY JOURNAL; RADIATION BEAM; RADIATION DETECTION; RADIATION DOSE; RADIATION EXPOSURE; RADIATION MEASUREMENT; RADIOSENSITIVITY;

EID: 84858859655     PISSN: 18650333     EISSN: 18650341     Source Type: Journal    
DOI: 10.1007/s12194-011-0135-0     Document Type: Article
Times cited : (8)

References (22)
  • 1
    • 21144440833 scopus 로고    scopus 로고
    • The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations
    • DOI 10.1118/1.1924309
    • Tzedakis A, Damilakis J, Perisinakis K, Stratakis J, Gourtsoyiannis N. The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations. Med Phys. 2005;32:1621-9. (Pubitemid 40880556)
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 1621-1629
    • Tzedakis, A.1    Damilakis, J.2    Perisinakis, K.3    Stratakis, J.4    Gourtsoyiannis, N.5
  • 2
    • 0036336399 scopus 로고    scopus 로고
    • Primary radiation outside the imaged volume of a multislice helical CT scan
    • Nicholson R, Fetherston S. Primary radiation outside the imaged volume of a multislice helical CT scan. Br J Radiol. 2002;75: 518-22. (Pubitemid 34863408)
    • (2002) British Journal of Radiology , vol.75 , Issue.894 , pp. 518-522
    • Nicholson, R.1    Fetherston, S.2
  • 3
    • 34147100532 scopus 로고    scopus 로고
    • Energy imparted-based estimates of the effect of z overscanning on adult and pediatric patient effective doses from multi-slice computed tomography
    • DOI 10.1118/1.2436980
    • Theocharopoulos N, Damilakis J, Perisinakis K, Gourtsoyiannis N. Energy imparted-based estimates of the effect of z overscanning on adult and pediatric patient effective doses from multislice computed tomography. Med Phys. 2007;34:1139-52. (Pubitemid 46555745)
    • (2007) Medical Physics , vol.34 , Issue.4 , pp. 1139-1152
    • Theocharopoulos, N.1    Damilakis, J.2    Perisinakis, K.3    Gourtsoyiannis, N.4
  • 4
    • 34147097370 scopus 로고    scopus 로고
    • Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations
    • DOI 10.1118/1.2710331
    • Tzedakis A, Damilakis J, Perisinakis K, Karantanas A, Karabekios S, Gourtsoyiannis N. Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations. Med Phys. 2007;34: 1163-75. (Pubitemid 46555747)
    • (2007) Medical Physics , vol.34 , Issue.4 , pp. 1163-1175
    • Tzedakis, A.1    Damilakis, J.2    Perisinakis, K.3    Karantanas, A.4    Karabekios, S.5    Gourtsoyiannis, N.6
  • 5
    • 33845655515 scopus 로고    scopus 로고
    • Overranging in multisection CT: Quantification and relative contribution to dose - Comparison of four 16-section CT scanners
    • DOI 10.1148/radiol.2421051350
    • van der Molen AJ, Geleijns J. Overranging in multisection CT: quantification and relative contribution to dose - comparison of four 16-section CT scanners. Radiology. 2007;242:208-16. (Pubitemid 44956026)
    • (2007) Radiology , vol.242 , Issue.1 , pp. 208-216
    • Van Der, M.A.J.1    Geleijns, J.2
  • 7
    • 18844403150 scopus 로고    scopus 로고
    • Multi-detector row CT systems and image-reconstruction techniques
    • DOI 10.1148/radiol.2353040037
    • Flohr TG, Schaller S, Stierstorfer K, Bruder H, Ohnesorge BM, Schoepf UJ. Multi-detector row CT systems and image-reconstruction techniques. Radiology. 2005;235:756-73. (Pubitemid 40695869)
    • (2005) Radiology , vol.235 , Issue.3 , pp. 756-773
    • Flohr, T.G.1    Schaller, S.2    Stierstorfer, K.3    Bruder, H.4    Ohnesorge, B.M.5    Schoepf, U.J.6
  • 8
    • 0031956821 scopus 로고    scopus 로고
    • Algorithm for image reconstruction in multi-slice helical CT
    • DOI 10.1118/1.598230
    • Taguchi K, Aradate H. Algorithm for image reconstruction in multi-slice helical CT. Med Phys. 1998;25:550-61. (Pubitemid 28178363)
    • (1998) Medical Physics , vol.25 , Issue.4 , pp. 550-561
    • Taguchi, K.1    Aradate, H.2
  • 12
    • 60249097139 scopus 로고    scopus 로고
    • A comparison of the dosimetric characteristics of a glass rod dosimeter and a thermoluminescent dosimeter for mailed dosimeter
    • Rah J-E, Hong J-Y, Kim G-Y, Kim Y-L, Shin D-O, Suh T-S. A comparison of the dosimetric characteristics of a glass rod dosimeter and a thermoluminescent dosimeter for mailed dosimeter. Radiat Meas. 2009;44:18-22.
    • (2009) Radiat Meas , vol.44 , pp. 18-22
    • Rah, J.-E.1    Hong, J.-Y.2    Kim, G.-Y.3    Kim, Y.-L.4    Shin, D.-O.5    Suh, T.-S.6
  • 13
    • 0028070216 scopus 로고
    • Understanding and optimizing use of contrast material for CT of the liver
    • Baron RL. Understanding and optimizing use of contrast material for CT of the liver. AJR Am J Roentgenol. 1994;163:323-31. (Pubitemid 24242512)
    • (1994) American Journal of Roentgenology , vol.163 , Issue.2 , pp. 323-331
    • Baron, R.L.1
  • 14
    • 0036720964 scopus 로고    scopus 로고
    • Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multi-detector row helical CT
    • Awai K, Takada K, Onishi H, Hori S. Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT. Radiology. 2002;224:757-63. (Pubitemid 34919809)
    • (2002) Radiology , vol.224 , Issue.3 , pp. 757-763
    • Awai, K.1    Takada, K.2    Onishi, H.3    Hori, S.4
  • 17
    • 0037406916 scopus 로고    scopus 로고
    • Hepatic arteries in potential donors for living related liver transplantation: Evaluation with multi-detector row CT angiography
    • DOI 10.1148/radiol.2272012033
    • Lee SS, Kim TK, Byun JH, Ha HK, Kim PN, Kim AY, Lee SG, Lee MG. Hepatic arteries in potential donors for living related liver transplantation: evaluation with multi-detector row CT angiography. Radiology. 2003;227:391-9. (Pubitemid 36514752)
    • (2003) Radiology , vol.227 , Issue.2 , pp. 391-399
    • Lee, S.S.1    Kim, T.K.2    Byun, J.H.3    Ha, H.K.4    Kim, P.N.5    Kim, A.Y.6    Lee, S.G.7    Lee, M.-G.8
  • 18
    • 0036311793 scopus 로고    scopus 로고
    • Potential living liver donors: Evaluation with an all-in-one protocol with multi-detector row CT
    • Schroeder T, Nadalin S, Stattaus J, Debatin JF, Malago M, Ruehm SG. Potential living liver donors: evaluation with an allin- one protocol with multi-detector row CT. Radiology. 2002;224:586-91. (Pubitemid 34809145)
    • (2002) Radiology , vol.224 , Issue.2 , pp. 586-591
    • Schroeder, T.1    Nadalin, S.2    Stattaus, J.3    Debatin, J.F.4    Malago, M.5    Ruehm, S.G.6
  • 19
  • 20
    • 0346218104 scopus 로고    scopus 로고
    • Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient Weight
    • DOI 10.1148/radiol.2301021008
    • Awai K, Hiraishi K, Hori S. Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight. Radiology. 2004;230:142-50. (Pubitemid 37549795)
    • (2004) Radiology , vol.230 , Issue.1 , pp. 142-150
    • Awai, K.1    Hiraishi, K.2    Hori, S.3
  • 22
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. Radiographics. 2004;24:1679-91.
    • (2004) Radiographics , vol.24 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.