-
1
-
-
79951927394
-
64-Slice multidetector row CT angiography of the abdomen: Comparison of low versus high concentration iodinated contrast media in a porcine model
-
Holalkere NS, Matthes K, Kalva SP, et al. 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model. Br J Radiol 2011; 84:221-228
-
(2011)
Br J Radiol
, vol.84
, pp. 221-228
-
-
Holalkere, N.S.1
Matthes, K.2
Kalva, S.P.3
-
2
-
-
27144460830
-
Angiographic imaging of the lower extremities with multidetector CT
-
DOI 10.1016/j.rcl.2005.08.008, PII S0033838905001296, Multidetector CT of the Abdomen
-
Hiatt MD, Fleischmann D, Hellinger JC, Rubin GD. Angiographic imaging of the lower extremities with multidetector CT. Radiol Clin North Am 2005; 43:1119-1127, ix (Pubitemid 41505388)
-
(2005)
Radiologic Clinics of North America
, vol.43
, Issue.6
, pp. 1119-1127
-
-
Hiatt, M.D.1
Fleischmann, D.2
Hellinger, J.C.3
Rubin, G.D.4
-
3
-
-
3342879024
-
Computed tomography angiography: State-of-the-art imaging using multidetector-row technology
-
DOI 10.1097/01.rct.0000120859.80935.10
-
Napoli A, Fleischmann D, Chan FP, et al. Computed tomography angiography: state-of-the-art imaging using multidetector-row technology. J Comput Assist Tomogr 2004; 28(suppl 1):S32-S45 (Pubitemid 38988806)
-
(2004)
Journal of Computer Assisted Tomography
, vol.28
, Issue.SUPPL. 1
-
-
Napoli, A.1
Fleischmann, D.2
Chan, F.P.3
Catalano, C.4
Hellinger, J.C.5
Passariello, R.6
Rubin, G.D.7
-
4
-
-
0034311882
-
Multislice CT angiography
-
Prokop M. Multislice CT angiography. Eur J Radiol 2000; 36:86-96
-
(2000)
Eur J Radiol
, vol.36
, pp. 86-96
-
-
Prokop, M.1
-
5
-
-
63449097524
-
High-pitch spiral acquisition: A new scan mode for coronary CT angiography
-
Achenbach S, Marwan M, Schepis T, et al. High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr 2009; 3:117-121
-
(2009)
J Cardiovasc Comput Tomogr
, vol.3
, pp. 117-121
-
-
Achenbach, S.1
Marwan, M.2
Schepis, T.3
-
6
-
-
77950604781
-
High-pitch dual-source CT angiography of the thoracic and abdominal aorta: Is simultaneous coronary artery assessment possible?
-
Goetti R, Baumuller S, Feuchtner G, et al. High-pitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible? AJR 2010; 194:938-944
-
(2010)
AJR
, vol.194
, pp. 938-944
-
-
Goetti, R.1
Baumuller, S.2
Feuchtner, G.3
-
7
-
-
77952097970
-
Dual-source chest CT angiography with high temporal resolution and high pitch modes: Evaluation of image quality in 140 patients
-
Tacelli N, Remy-Jardin M, Flohr T, et al. Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patients. Eur Radiol 2010; 20:1188-1196
-
(2010)
Eur Radiol
, vol.20
, pp. 1188-1196
-
-
Tacelli, N.1
Remy-Jardin, M.2
Flohr, T.3
-
8
-
-
78650555385
-
High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization
-
Karlo C, Leschka S, Goetti RP, et al. High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization. Eur Radiol 2011; 21:205-212
-
(2011)
Eur Radiol
, vol.21
, pp. 205-212
-
-
Karlo, C.1
Leschka, S.2
Goetti, R.P.3
-
9
-
-
79957825412
-
Use of high-pitch dual-source computed tomography of the abdomen and pelvis to markedly reduce scan time: Clinical feasibility study
-
Hardie AD, Mayes N, Boulter DJ. Use of high-pitch dual-source computed tomography of the abdomen and pelvis to markedly reduce scan time: clinical feasibility study. J Comput Assist Tomogr 2011; 35:353-355
-
(2011)
J Comput Assist Tomogr
, vol.35
, pp. 353-355
-
-
Hardie, A.D.1
Mayes, N.2
Boulter, D.J.3
-
10
-
-
84857042898
-
High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
-
Beeres M, Schell B, Mastragelopoulos A, et al. High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: initial experience. Eur Radiol 2012; 22:129-137
-
(2012)
Eur Radiol
, vol.22
, pp. 129-137
-
-
Beeres, M.1
Schell, B.2
Mastragelopoulos, A.3
-
11
-
-
0033788187
-
European measurements of aircraft crew exposure to cosmic radiation
-
Menzel HG, O'Sullivan D, Beck P, Bartlett D. European measurements of aircraft crew exposure to cosmic radiation. Health Phys 2000; 79:563-567
-
(2000)
Health Phys
, vol.79
, pp. 563-567
-
-
Menzel, H.G.1
O'Sullivan, D.2
Beck, P.3
Bartlett, D.4
-
12
-
-
33846667184
-
Abdominal aortic aneurysm: Can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose?
-
DOI 10.1148/radiol.2413051571
-
Macari M, Chandarana H, Schmidt B, et al. Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? Radiology 2006; 241:908-914 (Pubitemid 46190559)
-
(2006)
Radiology
, vol.241
, Issue.3
, pp. 908-914
-
-
Macari, M.1
Chandarana, H.2
Schmidt, B.3
Lee, J.4
Lamparello, P.5
Babb, J.6
-
13
-
-
70349678698
-
Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: Assessment of image quality and radiation dose
-
Schindera ST, Graca P, Patak MA, et al. Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose. Invest Radiol 2009; 44:650-655
-
(2009)
Invest Radiol
, vol.44
, pp. 650-655
-
-
Schindera, S.T.1
Graca, P.2
Patak, M.A.3
-
14
-
-
77957866866
-
Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease
-
Utsunomiya D, Oda S, Funama Y, et al. Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease. Eur Radiol 2010; 20:2758-2765
-
(2010)
Eur Radiol
, vol.20
, pp. 2758-2765
-
-
Utsunomiya, D.1
Oda, S.2
Funama, Y.3
-
15
-
-
79751526184
-
Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examinations in 80 patients
-
Pontana F, Duhamel A, Pagniez J, et al. Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examinations in 80 patients. Eur Radiol 2011; 21:636-643
-
(2011)
Eur Radiol
, vol.21
, pp. 636-643
-
-
Pontana, F.1
Duhamel, A.2
Pagniez, J.3
-
16
-
-
67650790313
-
Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients
-
Szucs-Farkas Z, Strautz T, Patak MA, et al. Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients. Eur Radiol 2009; 19:1914-1922
-
(2009)
Eur Radiol
, vol.19
, pp. 1914-1922
-
-
Szucs-Farkas, Z.1
Strautz, T.2
Patak, M.A.3
-
17
-
-
67650067593
-
Effects of adaptive section collimation on patient radiation dose in multisection spiral CT
-
Deak PD, Langner O, Lell M, et al. Effects of adaptive section collimation on patient radiation dose in multisection spiral CT. Radiology 2009; 252:140-147
-
(2009)
Radiology
, vol.252
, pp. 140-147
-
-
Deak, P.D.1
Langner, O.2
Lell, M.3
-
18
-
-
79959591690
-
Radiation dose at coronary CT angiography: Second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT
-
[web]W550-W557
-
Fink C, Krissak R, Henzler T, et al. Radiation dose at coronary CT angiography: second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT. AJR 2011; 196:1075; [web]W550-W557
-
(2011)
AJR
, vol.196
, pp. 1075
-
-
Fink, C.1
Krissak, R.2
Henzler, T.3
-
19
-
-
0038051949
-
Comparison between low (3:1) and high (6:1) pitch for routine abdominal/pelvic imaging with multislice computed tomography
-
DOI 10.1097/00004728-200303000-00001
-
Sahani D, Saini S, D'Souza RV, et al. Comparison between low (3:1) and high (6:1) pitch for routine abdominal/pelvic imaging with multislice computed tomography. J Comput Assist Tomogr 2003; 27:105-109 (Pubitemid 37047202)
-
(2003)
Journal of Computer Assisted Tomography
, vol.27
, Issue.2
, pp. 105-109
-
-
Sahani, D.1
Saini, S.2
D'Souza, R.V.3
O'Neill, M.J.4
Prasad, S.R.5
Kalra, M.K.6
Halpern, E.F.7
Mueller, P.8
-
21
-
-
0345491057
-
Radiation exposure in spiral computed tomography: Dose distribution and dose reduction
-
DOI 10.1097/00004424-199901000-00008
-
Hidajat N, Mäurer J, Schröder RJ, Wolf M, Vogl T, Felix R. Radiation exposure in spiral computed tomography: dose distribution and dose reduction. Invest Radiol 1999; 34:51-57 (Pubitemid 29109157)
-
(1999)
Investigative Radiology
, vol.34
, Issue.1
, pp. 51-57
-
-
Hidajat, N.1
Maurer, J.2
Schroder, R.-J.3
Wolf, M.4
Vogl, T.5
Felix, R.6
-
22
-
-
0030472878
-
The effect of helical pitch and beam collimation on the lesion contrast and slice profile in helical CT imaging
-
DOI 10.1118/1.597774
-
Hu H, Fox SH. The effect of helical pitch and beam collimation on the lesion contrast and slice profile in helical CT imaging. Med Phys 1996; 23:1943-1954 (Pubitemid 27023692)
-
(1996)
Medical Physics
, vol.23
, Issue.12
, pp. 1943-1954
-
-
Hu, H.1
Fox, S.H.2
-
23
-
-
34548581922
-
Solid cancer incidence in atomic bomb survivors: 1958-1998
-
DOI 10.1667/RR0763.1
-
Preston DL, Ron E, Tokuoka S, et al. Solid cancer incidence in atomic bomb survivors: 1958-1998. Radiat Res 2007; 168:1-64 (Pubitemid 351292925)
-
(2007)
Radiation Research
, vol.168
, Issue.1
, pp. 1-64
-
-
Preston, D.L.1
Ron, E.2
Tokuoka, S.3
Funamoto, S.4
Nishi, N.5
Soda, M.6
Mabuchi, K.7
Kodama, K.8
-
24
-
-
69349096036
-
Exposure to low-dose ionizing radiation from medical imaging procedures
-
Fazel R, Krumholz HM, Wang Y, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 2009; 361:849-857
-
(2009)
N Engl J Med
, vol.361
, pp. 849-857
-
-
Fazel, R.1
Krumholz, H.M.2
Wang, Y.3
-
25
-
-
33746919048
-
Contrast-induced nephrotoxicity: Clinical landscape
-
Katzberg RW, Haller C. Contrast-induced nephrotoxicity: clinical landscape. Kidney Int Suppl 2006; 100:S3-S7
-
(2006)
Kidney Int Suppl
, vol.100
-
-
Katzberg, R.W.1
Haller, C.2
-
26
-
-
33747845241
-
Contrast media and nephropathy: Findings from systematic analysis and food and drug administration reports of adverse effects
-
DOI 10.1097/01.rli.0000229742.54589.7b, PII 0000442420060800000008
-
Solomon R, Dumouchel W. Contrast media and nephropathy: findings from systematic analysis and Food and Drug Administration reports of adverse effects. Invest Radiol 2006; 41:651-660 (Pubitemid 44284174)
-
(2006)
Investigative Radiology
, vol.41
, Issue.8
, pp. 651-660
-
-
Solomon, R.1
DuMouchel, W.2
|