-
1
-
-
36849100445
-
-
Restricted self-diffusion of protons in colloidal systems by pulsed-gradient spin-echo method. ; :
-
Tanner JE, Stejskal EO. Restricted self-diffusion of protons in colloidal systems by pulsed-gradient spin-echo method. J. Chem. Phys. 1968; 49(4): 1768-1777.
-
(1968)
J. Chem. Phys.
, vol.49
, Issue.4
, pp. 1768-1777
-
-
Tanner, J.E.1
Stejskal, E.O.2
-
2
-
-
0015152595
-
Pulsed NMR measurements of the diffusion constant of water in muscle
-
Finch ED, Harmon JF, Muller BH. Pulsed NMR measurements of the diffusion constant of water in muscle. Arch. Biochem. Biophys. 1971; 147(1): 299-310.
-
(1971)
Arch. Biochem. Biophys.
, vol.147
, Issue.1
, pp. 299-310
-
-
Finch, E.D.1
Harmon, J.F.2
Muller, B.H.3
-
3
-
-
0015939524
-
Implications of diffusion coefficient measurements for the structure of cellular water
-
Chang DC, Rorschach HE, Nichols BL, Hazlewood CF. Implications of diffusion coefficient measurements for the structure of cellular water. Ann. NY Acad. Sci. 1973; 204: 434-443.
-
(1973)
Ann. NY Acad. Sci.
, vol.204
, pp. 434-443
-
-
Chang, D.C.1
Rorschach, H.E.2
Nichols, B.L.3
Hazlewood, C.F.4
-
5
-
-
0017098107
-
Nuclear magnetic resonance measurement of skeletal muscle: anisotropy of the diffusion coefficient of the intracellular water
-
Cleveland GG, Chang DC, Hazlewood CF, Rorschach HE. Nuclear magnetic resonance measurement of skeletal muscle: anisotropy of the diffusion coefficient of the intracellular water. Biophys. J. 1976; 16(9): 1043-1053.
-
(1976)
Biophys. J.
, vol.16
, Issue.9
, pp. 1043-1053
-
-
Cleveland, G.G.1
Chang, D.C.2
Hazlewood, C.F.3
Rorschach, H.E.4
-
6
-
-
0025323825
-
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system
-
Moseley ME, Cohen Y, Kucharczyk J, Mintorovitch J, Asgari HS, Wendland MF, Tsuruda J, Norman D. Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system. Radiology 1990; 176(2): 439-445.
-
(1990)
Radiology
, vol.176
, Issue.2
, pp. 439-445
-
-
Moseley, M.E.1
Cohen, Y.2
Kucharczyk, J.3
Mintorovitch, J.4
Asgari, H.S.5
Wendland, M.F.6
Tsuruda, J.7
Norman, D.8
-
7
-
-
0025049046
-
Echo-planar imaging of intravoxel incoherent motion
-
Turner R, Le Bihan D, Maier J, Vavrek R, Hedges LK, Pekar J. Echo-planar imaging of intravoxel incoherent motion. Radiology 1990; 177(2): 407-414.
-
(1990)
Radiology
, vol.177
, Issue.2
, pp. 407-414
-
-
Turner, R.1
Le Bihan, D.2
Maier, J.3
Vavrek, R.4
Hedges, L.K.5
Pekar, J.6
-
8
-
-
0028154030
-
MR diffusion tensor spectroscopy and imaging
-
Basser PJ, Mattiello J, LeBihan D. MR diffusion tensor spectroscopy and imaging. Biophys. J. 1994; 66(1): 259-267.
-
(1994)
Biophys. J.
, vol.66
, Issue.1
, pp. 259-267
-
-
Basser, P.J.1
Mattiello, J.2
LeBihan, D.3
-
9
-
-
0028398052
-
Estimation of the effective self-diffusion tensor from the NMR spin echo
-
Basser PJ, Mattiello J, LeBihan D. Estimation of the effective self-diffusion tensor from the NMR spin echo. J. Magn. Reson. B 1994; 103(3): 247-254.
-
(1994)
J. Magn. Reson. B
, vol.103
, Issue.3
, pp. 247-254
-
-
Basser, P.J.1
Mattiello, J.2
LeBihan, D.3
-
10
-
-
7544247899
-
"Squashing peanuts and smashing pumpkins": how noise distorts diffusion-weighted MR data
-
Jones DK, Basser PJ. "Squashing peanuts and smashing pumpkins": how noise distorts diffusion-weighted MR data. Magn. Reson. Med. 2004; 52(5): 979-993.
-
(2004)
Magn. Reson. Med.
, vol.52
, Issue.5
, pp. 979-993
-
-
Jones, D.K.1
Basser, P.J.2
-
11
-
-
78650472921
-
Twenty-five pitfalls in the analysis of diffusion MRI data
-
Jones DK, Cercignani M. Twenty-five pitfalls in the analysis of diffusion MRI data. NMR Biomed. 2010; 23(7): 803-820.
-
(2010)
NMR Biomed.
, vol.23
, Issue.7
, pp. 803-820
-
-
Jones, D.K.1
Cercignani, M.2
-
13
-
-
35248816901
-
Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T
-
Farrell JAD, Landman BA, Jones CK, Smith SA, Prince JL, van Zijl PCM, Mori S. Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T. J. Magn. Reson. Imaging 2007; 26(3): 756-767.
-
(2007)
J. Magn. Reson. Imaging
, vol.26
, Issue.3
, pp. 756-767
-
-
Farrell, J.A.D.1
Landman, B.A.2
Jones, C.K.3
Smith, S.A.4
Prince, J.L.5
van Zijl, P.C.M.6
Mori, S.7
-
14
-
-
34347240742
-
Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
-
Landman BA, Farrell JAD, Jones CK, Smith SA, Prince JL, Mori S. Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T. Neuroimage 2007; 36(4): 1123-1138.
-
(2007)
Neuroimage
, vol.36
, Issue.4
, pp. 1123-1138
-
-
Landman, B.A.1
Farrell, J.A.D.2
Jones, C.K.3
Smith, S.A.4
Prince, J.L.5
Mori, S.6
-
15
-
-
0037367362
-
Basic principles of diffusion-weighted imaging
-
Bammer R Basic principles of diffusion-weighted imaging. Eur. J. Radiol. 2003; 45(3): 169-184.
-
(2003)
Eur. J. Radiol.
, vol.45
, Issue.3
, pp. 169-184
-
-
Bammer, R.1
-
16
-
-
1842533406
-
The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study
-
Jones DK. The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study. Magn. Reson. Med. 2004; 51(4): 807-815.
-
(2004)
Magn. Reson. Med.
, vol.51
, Issue.4
, pp. 807-815
-
-
Jones, D.K.1
-
17
-
-
79958248349
-
Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla
-
Polders DL, Leemans A, Hendrikse J, Donahue MJ, Luijten PR, Hoogduin JM. Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla. J. Magn. Reson. Imaging 2011; 33(6): 1456-1463.
-
(2011)
J. Magn. Reson. Imaging
, vol.33
, Issue.6
, pp. 1456-1463
-
-
Polders, D.L.1
Leemans, A.2
Hendrikse, J.3
Donahue, M.J.4
Luijten, P.R.5
Hoogduin, J.M.6
-
18
-
-
0033022384
-
Diffusion tensor imaging in biomechanical studies of skeletal muscle function
-
Van Donkelaar CCV, Kretzers LJ, Bovendeerd PH, Lataster LM, Nicolay K, Janssen JD, Drost MR. Diffusion tensor imaging in biomechanical studies of skeletal muscle function. J. Anat. 1999; 194(Pt 1): 79-88.
-
(1999)
J. Anat.
, vol.194
, Issue.PART 1
, pp. 79-88
-
-
Van Donkelaar, C.C.V.1
Kretzers, L.J.2
Bovendeerd, P.H.3
Lataster, L.M.4
Nicolay, K.5
Janssen, J.D.6
Drost, M.R.7
-
19
-
-
0036299019
-
Validation of diffusion tensor MRI-based muscle fiber tracking
-
Damon BM, Ding Z, Anderson AW, Freyer AS, Gore JC. Validation of diffusion tensor MRI-based muscle fiber tracking. Magn. Reson. Med. 2002; 48(1): 97-104.
-
(2002)
Magn. Reson. Med.
, vol.48
, Issue.1
, pp. 97-104
-
-
Damon, B.M.1
Ding, Z.2
Anderson, A.W.3
Freyer, A.S.4
Gore, J.C.5
-
20
-
-
19544365262
-
Determination of mouse skeletal muscle architecture using three-dimensional diffusion tensor imaging
-
Heemskerk AM, Strijkers GJ, Vilanova A, Drost MR, Nicolay K. Determination of mouse skeletal muscle architecture using three-dimensional diffusion tensor imaging. Magn. Reson. Med. 2005; 53(6): 1333-1340.
-
(2005)
Magn. Reson. Med.
, vol.53
, Issue.6
, pp. 1333-1340
-
-
Heemskerk, A.M.1
Strijkers, G.J.2
Vilanova, A.3
Drost, M.R.4
Nicolay, K.5
-
21
-
-
36348937301
-
In vivo MR tractography of thigh muscles using diffusion imaging: initial results
-
Budzik JF, Le Thuc V, Demondion X, Morel M, Chechin D, Cotten A. In vivo MR tractography of thigh muscles using diffusion imaging: initial results. Eur. Radiol. 2007; 17(12): 3079-3085.
-
(2007)
Eur. Radiol.
, vol.17
, Issue.12
, pp. 3079-3085
-
-
Budzik, J.F.1
Le Thuc, V.2
Demondion, X.3
Morel, M.4
Chechin, D.5
Cotten, A.6
-
22
-
-
63449126914
-
DTI-based muscle fiber tracking of the quadriceps mechanism in lateral patellar dislocation
-
Kan JH, Heemskerk AM, Ding Z, Gregory A, Mencio G, Spindler K, Damon BM. DTI-based muscle fiber tracking of the quadriceps mechanism in lateral patellar dislocation. J. Magn. Reson. Imaging 2009; 29(3): 663-670.
-
(2009)
J. Magn. Reson. Imaging
, vol.29
, Issue.3
, pp. 663-670
-
-
Kan, J.H.1
Heemskerk, A.M.2
Ding, Z.3
Gregory, A.4
Mencio, G.5
Spindler, K.6
Damon, B.M.7
-
23
-
-
77949683741
-
Repeatability of DTI-based skeletal muscle fiber tracking
-
Heemskerk AM, Sinha TK, Wilson KJ, Ding Z, Damon BM. Repeatability of DTI-based skeletal muscle fiber tracking. NMR Biomed. 2010; 23(3): 294-303.
-
(2010)
NMR Biomed.
, vol.23
, Issue.3
, pp. 294-303
-
-
Heemskerk, A.M.1
Sinha, T.K.2
Wilson, K.J.3
Ding, Z.4
Damon, B.M.5
-
24
-
-
84862740652
-
Diffusion-tensor MRI reveals the complex muscle architecture of the human forearm
-
Froeling M, Nederveen AJ, Heijtel DF, Lataster A, Bos C, Nicolay K, Maas M, Drost MR, Strijkers GJ. Diffusion-tensor MRI reveals the complex muscle architecture of the human forearm. J. Magn. Reson. Imaging 2012; 36(1): 237-248.
-
(2012)
J. Magn. Reson. Imaging
, vol.36
, Issue.1
, pp. 237-248
-
-
Froeling, M.1
Nederveen, A.J.2
Heijtel, D.F.3
Lataster, A.4
Bos, C.5
Nicolay, K.6
Maas, M.7
Drost, M.R.8
Strijkers, G.J.9
-
25
-
-
79959216892
-
Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor
-
Zijta FM, Froeling M, van der Paardt MP, Lakeman MM, Bipat S, van Swijndregt AD, Strijkers GJ, Nederveen AJ, Stoker J. Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor. Eur. Radiol. 2011; 21(6): 1243-1249.
-
(2011)
Eur. Radiol.
, vol.21
, Issue.6
, pp. 1243-1249
-
-
Zijta, F.M.1
Froeling, M.2
van der Paardt, M.P.3
Lakeman, M.M.4
Bipat, S.5
van Swijndregt, A.D.6
Strijkers, G.J.7
Nederveen, A.J.8
Stoker, J.9
-
26
-
-
33746905458
-
Diffusion tensor imaging in evaluation of human skeletal muscle injury
-
Zaraiskaya T, Kumbhare D, Noseworthy MD. Diffusion tensor imaging in evaluation of human skeletal muscle injury. J. Magn. Reson. Imaging 2006; 24(2): 402-408.
-
(2006)
J. Magn. Reson. Imaging
, vol.24
, Issue.2
, pp. 402-408
-
-
Zaraiskaya, T.1
Kumbhare, D.2
Noseworthy, M.D.3
-
27
-
-
80053016181
-
-
Strenuous resistance exercise effects on magnetic resonance diffusion parameters and muscle-tendon function in human skeletal muscle. ; :
-
Yanagisawa O, Kurihara T, Kobayashi N, Fukubayashi T. Strenuous resistance exercise effects on magnetic resonance diffusion parameters and muscle-tendon function in human skeletal muscle. J. Magn. Reson. Imaging 2011; 34(4): 887-894.
-
(2011)
J. Magn. Reson. Imaging
, vol.34
, Issue.4
, pp. 887-894
-
-
Yanagisawa, O.1
Kurihara, T.2
Kobayashi, N.3
Fukubayashi, T.4
-
28
-
-
84855181446
-
Diffusion tensor MRI to assess damage in healthy and dystrophic skeletal muscle after lengthening contractions
-
McMillan AB, Shi D, Pratt SJ, Lovering RM. Diffusion tensor MRI to assess damage in healthy and dystrophic skeletal muscle after lengthening contractions. J. Biomed. Biotechnol. 2011; 2011: 970726.
-
(2011)
J. Biomed. Biotechnol.
, vol.2011
, pp. 970726
-
-
McMillan, A.B.1
Shi, D.2
Pratt, S.J.3
Lovering, R.M.4
-
29
-
-
34547828030
-
Diffusion tensor MRI assessment of skeletal muscle architecture
-
Heemskerk AM, Damon BM. Diffusion tensor MRI assessment of skeletal muscle architecture. Curr. Med. Imaging Rev. 2007; 3(3): 152-160.
-
(2007)
Curr. Med. Imaging Rev.
, vol.3
, Issue.3
, pp. 152-160
-
-
Heemskerk, A.M.1
Damon, B.M.2
-
30
-
-
47349128375
-
Magnetic resonance imaging of mouse skeletal muscle to measure denervation atrophy
-
Zhang J, Zhang G, Morrison B, Mori S, Sheikh KA. Magnetic resonance imaging of mouse skeletal muscle to measure denervation atrophy. Exp. Neurol. 2008; 212(2): 448-457.
-
(2008)
Exp. Neurol.
, vol.212
, Issue.2
, pp. 448-457
-
-
Zhang, J.1
Zhang, G.2
Morrison, B.3
Mori, S.4
Sheikh, K.A.5
-
31
-
-
30344484227
-
Evaluation of diffusional anisotropy and microscopic structure in skeletal muscles using magnetic resonance
-
Saotome T, Sekino M, Eto F, Ueno S. Evaluation of diffusional anisotropy and microscopic structure in skeletal muscles using magnetic resonance. Magn. Reson. Imaging 2006; 24(1): 19-25.
-
(2006)
Magn. Reson. Imaging
, vol.24
, Issue.1
, pp. 19-25
-
-
Saotome, T.1
Sekino, M.2
Eto, F.3
Ueno, S.4
-
32
-
-
54949159178
-
Diffusion-weighted MRI of denervated muscle: a clinical and experimental study
-
Holl N, Echaniz-Laguna A, Bierry G, Mohr M, Loeffler JP, Moser T, Dietemann JL, Kremer S. Diffusion-weighted MRI of denervated muscle: a clinical and experimental study. Skel. Radiol. 2008; 37(12): 1111-1117.
-
(2008)
Skel. Radiol.
, vol.37
, Issue.12
, pp. 1111-1117
-
-
Holl, N.1
Echaniz-Laguna, A.2
Bierry, G.3
Mohr, M.4
Loeffler, J.P.5
Moser, T.6
Dietemann, J.L.7
Kremer, S.8
-
33
-
-
33746736174
-
DTI-based assessment of ischemia-reperfusion in mouse skeletal muscle
-
Heemskerk AM, Drost MR, van Bochove GS, van Oosterhout MF, Nicolay K, Strijkers GJ. DTI-based assessment of ischemia-reperfusion in mouse skeletal muscle. Magn. Reson. Med. 2006; 56(2): 272-281.
-
(2006)
Magn. Reson. Med.
, vol.56
, Issue.2
, pp. 272-281
-
-
Heemskerk, A.M.1
Drost, M.R.2
van Bochove, G.S.3
van Oosterhout, M.F.4
Nicolay, K.5
Strijkers, G.J.6
-
34
-
-
34247533658
-
Skeletal muscle degeneration and regeneration after femoral artery ligation in mice: monitoring with diffusion MR imaging
-
Heemskerk AM, Strijkers GJ, Drost MR, van Bochove GS, Nicolay K. Skeletal muscle degeneration and regeneration after femoral artery ligation in mice: monitoring with diffusion MR imaging. Radiology 2007; 243(2): 413-421.
-
(2007)
Radiology
, vol.243
, Issue.2
, pp. 413-421
-
-
Heemskerk, A.M.1
Strijkers, G.J.2
Drost, M.R.3
van Bochove, G.S.4
Nicolay, K.5
-
35
-
-
53549121202
-
Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations
-
Damon BM. Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations. Magn. Reson. Med. 2008; 60(4): 934-944.
-
(2008)
Magn. Reson. Med.
, vol.60
, Issue.4
, pp. 934-944
-
-
Damon, B.M.1
-
36
-
-
84859643944
-
Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding
-
Karampinos DC, Banerjee S, King KF, Link TM, Majumdar S. Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding. NMR Biomed. 2012; 25(5): 766-778.
-
(2012)
NMR Biomed.
, vol.25
, Issue.5
, pp. 766-778
-
-
Karampinos, D.C.1
Banerjee, S.2
King, K.F.3
Link, T.M.4
Majumdar, S.5
-
37
-
-
34547697036
-
Quantitative diffusion tensor MRI-based fiber tracking of human skeletal muscle
-
Lansdown DA, Ding Z, Wadington M, Hornberger JL, Damon BM. Quantitative diffusion tensor MRI-based fiber tracking of human skeletal muscle. J. Appl. Physiol. 2007; 103(2): 673-681.
-
(2007)
J. Appl. Physiol.
, vol.103
, Issue.2
, pp. 673-681
-
-
Lansdown, D.A.1
Ding, Z.2
Wadington, M.3
Hornberger, J.L.4
Damon, B.M.5
-
38
-
-
44949264013
-
AxCaliber: a method for measuring axon diameter distribution from diffusion MRI
-
Assaf Y, Blumenfeld-Katzir T, Yovel Y, Basser PJ. AxCaliber: a method for measuring axon diameter distribution from diffusion MRI. Magn. Reson. Med. 2008; 59(6): 1347-1354.
-
(2008)
Magn. Reson. Med.
, vol.59
, Issue.6
, pp. 1347-1354
-
-
Assaf, Y.1
Blumenfeld-Katzir, T.2
Yovel, Y.3
Basser, P.J.4
-
39
-
-
0034055761
-
Form follows function: how muscle shape is regulated by work
-
Russell B, Motlagh D, Ashley WW. Form follows function: how muscle shape is regulated by work. J. Appl. Physiol. 2000; 88(3): 1127-1132.
-
(2000)
J. Appl. Physiol.
, vol.88
, Issue.3
, pp. 1127-1132
-
-
Russell, B.1
Motlagh, D.2
Ashley, W.W.3
-
40
-
-
0015798531
-
Data on fibre size in thirty-six human muscles
-
Polgar J, Johnson MA, Weightman D, Appleton D. Data on fibre size in thirty-six human muscles. An autopsy study. J. Neurol. Sci. 1973; 19(3): 307-318.
-
(1973)
An autopsy study. J. Neurol. Sci.
, vol.19
, Issue.3
, pp. 307-318
-
-
Polgar, J.1
Johnson, M.A.2
Weightman, D.3
Appleton, D.4
-
41
-
-
79952439655
-
Extracting skeletal muscle fiber fields from noisy diffusion tensor data
-
Levin DI, Gilles B, Madler B, Pai DK. Extracting skeletal muscle fiber fields from noisy diffusion tensor data. Med. Image Anal. 2011; 15(3): 340-353.
-
(2011)
Med. Image Anal.
, vol.15
, Issue.3
, pp. 340-353
-
-
Levin, D.I.1
Gilles, B.2
Madler, B.3
Pai, D.K.4
-
42
-
-
3242803606
-
Musculoskeletal MRI at 3.0 T: relaxation times and image contrast
-
Gold GE, Han E, Stainsby J, Wright G, Brittain J, Beaulieu C. Musculoskeletal MRI at 3.0 T: relaxation times and image contrast. Am. J. Roentgenol. 2004; 183(2): 343-351.
-
(2004)
Am. J. Roentgenol.
, vol.183
, Issue.2
, pp. 343-351
-
-
Gold, G.E.1
Han, E.2
Stainsby, J.3
Wright, G.4
Brittain, J.5
Beaulieu, C.6
-
43
-
-
24144448806
-
T1, T2 relaxation and magnetization transfer in tissue at 3T
-
Stanisz GJ, Odrobina EE, Pun J, Escaravage M, Graham SJ, Bronskill MJ, Henkelman RM. T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn. Reson. Med. 2005; 54(3): 507-512.
-
(2005)
Magn. Reson. Med.
, vol.54
, Issue.3
, pp. 507-512
-
-
Stanisz, G.J.1
Odrobina, E.E.2
Pun, J.3
Escaravage, M.4
Graham, S.J.5
Bronskill, M.J.6
Henkelman, R.M.7
-
44
-
-
0032914675
-
NMR relaxation times in the human brain at 3.0 tesla
-
Wansapura JP, Holland SK, Dunn RS, Ball WS Jr. NMR relaxation times in the human brain at 3.0 tesla. J. Magn. Reson. Imaging 1999; 9(4): 531-538.
-
(1999)
J. Magn. Reson. Imaging
, vol.9
, Issue.4
, pp. 531-538
-
-
Wansapura, J.P.1
Holland, S.K.2
Dunn, R.S.3
Ball Jr., W.S.4
-
46
-
-
70450253112
-
Myofiber ellipticity as an explanation for transverse asymmetry of skeletal muscle diffusion MRI in vivo signal
-
Karampinos DC, King KF, Sutton BP, Georgiadis JG. Myofiber ellipticity as an explanation for transverse asymmetry of skeletal muscle diffusion MRI in vivo signal. Ann. Biomed. Eng. 2009; 37(12): 2532-2546.
-
(2009)
Ann. Biomed. Eng.
, vol.37
, Issue.12
, pp. 2532-2546
-
-
Karampinos, D.C.1
King, K.F.2
Sutton, B.P.3
Georgiadis, J.G.4
-
47
-
-
84885952934
-
-
Reconstruction of 3-D fabric structure and fiber nets in skeletal muscle via in vivo DTI. Proceedings of the 19th Annual Meeting ISMRM, Montreal, QC, Canada
-
Gharibans AA, Johnson CL, Chen DD, Georgiadis JG. Reconstruction of 3-D fabric structure and fiber nets in skeletal muscle via in vivo DTI. Proceedings of the 19th Annual Meeting ISMRM, Montreal, QC, Canada, 2011; 1154.
-
(2011)
, pp. 1154
-
-
Gharibans, A.A.1
Johnson, C.L.2
Chen, D.D.3
Georgiadis, J.G.4
-
48
-
-
33644810277
-
Echoplanar diffusion tensor imaging of the lower leg musculature using eddy current nulled stimulated echo preparation
-
Steidle G, Schick F. Echoplanar diffusion tensor imaging of the lower leg musculature using eddy current nulled stimulated echo preparation. Magn. Reson. Med. 2006; 55(3): 541-548.
-
(2006)
Magn. Reson. Med.
, vol.55
, Issue.3
, pp. 541-548
-
-
Steidle, G.1
Schick, F.2
-
49
-
-
0000211468
-
Analytical expressions for the B-matrix in NMR diffusion imaging and spectroscopy
-
Mattiello J, Basser PJ, Lebihan D. Analytical expressions for the B-matrix in NMR diffusion imaging and spectroscopy. J. Magn. Reson. Ser. A 1994; 108(2): 131-141.
-
(1994)
J. Magn. Reson. Ser. A
, vol.108
, Issue.2
, pp. 131-141
-
-
Mattiello, J.1
Basser, P.J.2
Lebihan, D.3
-
50
-
-
0032835247
-
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
-
Jones DK, Horsfield MA, Simmons A. Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn. Reson. Med. 1999; 42(3): 515-525.
-
(1999)
Magn. Reson. Med.
, vol.42
, Issue.3
, pp. 515-525
-
-
Jones, D.K.1
Horsfield, M.A.2
Simmons, A.3
-
51
-
-
0033869742
-
Minimal gradient encoding for robust estimation of diffusion anisotropy
-
Papadakis NG, Murrills CD, Hall LD, Huang CL, Adrian CT. Minimal gradient encoding for robust estimation of diffusion anisotropy. Magn. Reson. Imaging 2000; 18(6): 671-679.
-
(2000)
Magn. Reson. Imaging
, vol.18
, Issue.6
, pp. 671-679
-
-
Papadakis, N.G.1
Murrills, C.D.2
Hall, L.D.3
Huang, C.L.4
Adrian, C.T.5
-
52
-
-
17044379193
-
-
DTI visualization with streamsurfaces and evenly-spaced volume seeding. Conference Proceedings in VisSym '04 Joint Eurographics - IEEE TCVG Symposium on Visualization, Konstanz, Germany
-
Vilanova A, Berenshot G, van de Pul C. DTI visualization with streamsurfaces and evenly-spaced volume seeding. Conference Proceedings in VisSym '04 Joint Eurographics - IEEE TCVG Symposium on Visualization, Konstanz, Germany, 2004; 173-182.
-
(2004)
, pp. 173-182
-
-
Vilanova, A.1
Berenshot, G.2
van de Pul, C.3
-
53
-
-
33747872177
-
A unifying theoretical and algorithmic framework for least squares methods of estimation in diffusion tensor imaging
-
Koay CG, Chang LC, Carew JD, Pierpaoli C, Basser PJ. A unifying theoretical and algorithmic framework for least squares methods of estimation in diffusion tensor imaging. J. Magn. Reson. 2006; 182(1): 115-125.
-
(2006)
J. Magn. Reson.
, vol.182
, Issue.1
, pp. 115-125
-
-
Koay, C.G.1
Chang, L.C.2
Carew, J.D.3
Pierpaoli, C.4
Basser, P.J.5
-
54
-
-
33645760884
-
Investigation of anomalous estimates of tensor-derived quantities in diffusion tensor imaging
-
Koay CG, Carew JD, Alexander AL, Basser PJ, Meyerand ME. Investigation of anomalous estimates of tensor-derived quantities in diffusion tensor imaging. Magn. Reson. Med. 2006; 55(4): 930-936.
-
(2006)
Magn. Reson. Med.
, vol.55
, Issue.4
, pp. 930-936
-
-
Koay, C.G.1
Carew, J.D.2
Alexander, A.L.3
Basser, P.J.4
Meyerand, M.E.5
-
56
-
-
84885951977
-
-
Navigator aided, multishot EPI diffusion images of brain with complete orientation and anisotropy information. Proceedings of the XXth Annual Meeting ISMRM, Philadelphia, PA, USA
-
Muthupallai R, Holder C, Song A, Dixon W. Navigator aided, multishot EPI diffusion images of brain with complete orientation and anisotropy information. Proceedings of the XXth Annual Meeting ISMRM, Philadelphia, PA, USA, 1999; 1825.
-
(1999)
, pp. 1825
-
-
Muthupallai, R.1
Holder, C.2
Song, A.3
Dixon, W.4
-
57
-
-
84860477766
-
Polynomial fitting of DT-MRI fiber tracts allows accurate estimation of muscle architectural parameters
-
Damon BM, Heemskerk AM, Ding Z. Polynomial fitting of DT-MRI fiber tracts allows accurate estimation of muscle architectural parameters. Magn. Reson. Imaging 2012; 30(5): 489-500.
-
(2012)
Magn. Reson. Imaging
, vol.30
, Issue.5
, pp. 489-500
-
-
Damon, B.M.1
Heemskerk, A.M.2
Ding, Z.3
-
58
-
-
67049116294
-
The B-matrix must be rotated when correcting for subject motion in DTI data
-
Leemans A, Jones DK. The B-matrix must be rotated when correcting for subject motion in DTI data. Magn. Reson. Med. 2009; 61(6): 1336-1349.
-
(2009)
Magn. Reson. Med.
, vol.61
, Issue.6
, pp. 1336-1349
-
-
Leemans, A.1
Jones, D.K.2
-
59
-
-
84885959678
-
-
Automated muscle fat segmentation in DTI data of post-polio patients based on parameter distirbutions. Proceedings of the 20th Annual Meeting ISMRM, Melbourne, Australia
-
Froeling M, Strijkers GJ, Nollet F, de Visser M, Nicolay K, Nederveen AJ. Automated muscle fat segmentation in DTI data of post-polio patients based on parameter distirbutions. Proceedings of the 20th Annual Meeting ISMRM, Melbourne, Australia, 2012; 3264.
-
(2012)
, pp. 3264
-
-
Froeling, M.1
Strijkers, G.J.2
Nollet, F.3
de Visser, M.4
Nicolay, K.5
Nederveen, A.J.6
-
60
-
-
34547879249
-
Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters
-
Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J. Magn. Reson. Imaging 2007; 26(2): 375-385.
-
(2007)
J. Magn. Reson. Imaging
, vol.26
, Issue.2
, pp. 375-385
-
-
Dietrich, O.1
Raya, J.G.2
Reeder, S.B.3
Reiser, M.F.4
Schoenberg, S.O.5
-
61
-
-
24144470505
-
Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: application with cardiac imaging and a 32-channel cardiac coil
-
Reeder SB, Wintersperger BJ, Dietrich O, Lanz T, Greiser A, Reiser MF, Glazer GM, Schoenberg SO. Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: application with cardiac imaging and a 32-channel cardiac coil. Magn. Reson. Med. 2005; 54(3): 748-754.
-
(2005)
Magn. Reson. Med.
, vol.54
, Issue.3
, pp. 748-754
-
-
Reeder, S.B.1
Wintersperger, B.J.2
Dietrich, O.3
Lanz, T.4
Greiser, A.5
Reiser, M.F.6
Glazer, G.M.7
Schoenberg, S.O.8
-
62
-
-
0036134282
-
In vivo diffusion tensor imaging of human calf muscle
-
Sinha U, Yao L. In vivo diffusion tensor imaging of human calf muscle. J. Magn. Reson. Imaging 2002; 15(1): 87-95.
-
(2002)
J. Magn. Reson. Imaging
, vol.15
, Issue.1
, pp. 87-95
-
-
Sinha, U.1
Yao, L.2
-
63
-
-
0033945138
-
Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
-
Basser PJ, Pajevic S. Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise. Magn. Reson. Med. 2000; 44(1): 41-50.
-
(2000)
Magn. Reson. Med.
, vol.44
, Issue.1
, pp. 41-50
-
-
Basser, P.J.1
Pajevic, S.2
-
64
-
-
44449114653
-
The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging
-
Koay CG, Nevo U, Chang LC, Pierpaoli C, Basser PJ. The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging. IEEE Trans. Med. Imaging 2008; 27(6): 834-846.
-
(2008)
IEEE Trans. Med. Imaging
, vol.27
, Issue.6
, pp. 834-846
-
-
Koay, C.G.1
Nevo, U.2
Chang, L.C.3
Pierpaoli, C.4
Basser, P.J.5
-
65
-
-
84863855472
-
Six is enough? Comparison of diffusion parameters measured using six or more diffusion-encoding gradient directions with deterministic tractography
-
Lebel C, Benner T, Beaulieu C. Six is enough? Comparison of diffusion parameters measured using six or more diffusion-encoding gradient directions with deterministic tractography. Magn. Reson. Med. 2011; 68(3): 474-483.
-
(2011)
Magn. Reson. Med.
, vol.68
, Issue.3
, pp. 474-483
-
-
Lebel, C.1
Benner, T.2
Beaulieu, C.3
-
66
-
-
0035038227
-
Comparison of gradient encoding schemes for diffusion-tensor MRI
-
Hasan KM, Parker DL, Alexander AL. Comparison of gradient encoding schemes for diffusion-tensor MRI. J. Magn. Reson. Imaging 2001; 13(5): 769-780.
-
(2001)
J. Magn. Reson. Imaging
, vol.13
, Issue.5
, pp. 769-780
-
-
Hasan, K.M.1
Parker, D.L.2
Alexander, A.L.3
-
67
-
-
84885959096
-
-
Effect of b-value and TE on the estimation of intramyocellular diffusion properties in the presence of edema. Proceedings of the 17th Annual Meeting ISMRM, Honolulu, HI, USA
-
Damon B. Effect of b-value and TE on the estimation of intramyocellular diffusion properties in the presence of edema. Proceedings of the 17th Annual Meeting ISMRM, Honolulu, HI, USA, 2009; 1435.
-
(2009)
, pp. 1435
-
-
Damon, B.1
-
68
-
-
67049158060
-
Diffusion tensor imaging and fiber tractography of skeletal muscle: optimization of b value for imaging at 1.5 T
-
Saupe N, White LM, Stainsby J, Tomlinson G, Sussman MS. Diffusion tensor imaging and fiber tractography of skeletal muscle: optimization of b value for imaging at 1.5 T. Am. J. Roentgenol. 2009; 192(6): W282-W290.
-
(2009)
Am. J. Roentgenol.
, vol.192
, Issue.6
-
-
Saupe, N.1
White, L.M.2
Stainsby, J.3
Tomlinson, G.4
Sussman, M.S.5
-
69
-
-
55249092319
-
Diffusion tensor magnetic resonance imaging of the human calf - comparison between 1.5 T and 3.0 T - preliminary results
-
Saupe N, White LM, Sussman MS, Kassner A, Tomlinson G, Noseworthy MD. Diffusion tensor magnetic resonance imaging of the human calf - comparison between 1.5 T and 3.0 T - preliminary results. Invest. Radiol. 2008; 43(9): 612-618.
-
(2008)
Invest. Radiol.
, vol.43
, Issue.9
, pp. 612-618
-
-
Saupe, N.1
White, L.M.2
Sussman, M.S.3
Kassner, A.4
Tomlinson, G.5
Noseworthy, M.D.6
-
70
-
-
77955323071
-
Estimation of diffusion properties in crossing fiber bundles
-
Caan MW, Khedoe HG, Poot DH, den Dekker AJ, Olabarriaga SD, Grimbergen KA, van Vliet LJ, Vos FM. Estimation of diffusion properties in crossing fiber bundles. IEEE Trans. Med. Imaging 2010; 29(8): 1504-1515.
-
(2010)
IEEE Trans. Med. Imaging
, vol.29
, Issue.8
, pp. 1504-1515
-
-
Caan, M.W.1
Khedoe, H.G.2
Poot, D.H.3
Den Dekker, A.J.4
Olabarriaga, S.D.5
Grimbergen, K.A.6
van Vliet, L.J.7
Vos, F.M.8
-
71
-
-
48349147550
-
Compartmental relaxation and diffusion tensor imaging measurements in vivo in lambda-carrageenan-induced edema in rat skeletal muscle
-
Fan RH, Does MD. Compartmental relaxation and diffusion tensor imaging measurements in vivo in lambda-carrageenan-induced edema in rat skeletal muscle. NMR Biomed. 2008; 21(6): 566-573.
-
(2008)
NMR Biomed
, vol.21
, Issue.6
, pp. 566-573
-
-
Fan, R.H.1
Does, M.D.2
-
72
-
-
49249126731
-
On the correlation between T2 and tissue diffusion coefficients in exercised muscle: quantitative measurements at 3 T within the tibialis anterior
-
Ababneh ZQ, Ababneh R, Maier SE, Winalski CS, Oshio K, Ababneh AM, Mulkern RV. On the correlation between T2 and tissue diffusion coefficients in exercised muscle: quantitative measurements at 3 T within the tibialis anterior. MAGMA 2008; 21(4): 273-278.
-
(2008)
MAGMA
, vol.21
, Issue.4
, pp. 273-278
-
-
Ababneh, Z.Q.1
Ababneh, R.2
Maier, S.E.3
Winalski, C.S.4
Oshio, K.5
Ababneh, A.M.6
Mulkern, R.V.7
-
73
-
-
33746905458
-
Diffusion tensor imaging in evaluation of human skeletal muscle injury
-
Zaraiskaya T, Kumbhare D, Noseworthy MD. Diffusion tensor imaging in evaluation of human skeletal muscle injury. J. Magn. Reson. Imaging 2006; 24(2): 402-408.
-
(2006)
J. Magn. Reson. Imaging
, vol.24
, Issue.2
, pp. 402-408
-
-
Zaraiskaya, T.1
Kumbhare, D.2
Noseworthy, M.D.3
-
74
-
-
53049097306
-
MRI analysis of structural changes in skeletal muscles and surrounding tissues following long-term walking exercise with training equipment
-
Nakai R, Azuma T, Sudo M, Urayama S, Takizawa O, Tsutsumi S. MRI analysis of structural changes in skeletal muscles and surrounding tissues following long-term walking exercise with training equipment. J. Appl. Physiol. 2008; 105(3): 958-963.
-
(2008)
J. Appl. Physiol.
, vol.105
, Issue.3
, pp. 958-963
-
-
Nakai, R.1
Azuma, T.2
Sudo, M.3
Urayama, S.4
Takizawa, O.5
Tsutsumi, S.6
-
75
-
-
13844294050
-
A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii
-
Blemker SS, Pinsky PM, Delp SL. A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii. J. Biomech. 2005; 38(4): 657-665.
-
(2005)
J. Biomech.
, vol.38
, Issue.4
, pp. 657-665
-
-
Blemker, S.S.1
Pinsky, P.M.2
Delp, S.L.3
|