메뉴 건너뛰기




Volumn 30, Issue 5, 2012, Pages 589-600

Polynomial fitting of DT-MRI fiber tracts allows accurate estimation of muscle architectural parameters

Author keywords

Curve fitting; Diffusion tensor; Muscle architecture; Noise; Skeletal muscle

Indexed keywords

ACCURACY; ANALYTICAL PARAMETERS; ARTICLE; ASPECT RATIO; CONTROLLED STUDY; CURVE FITTING; DATA ANALYSIS; DIFFUSION TENSOR IMAGING; FIBER CURVATURE; HUMAN; IMAGING AND DISPLAY; MUSCLE FIBER TRACKING; POLYNOMIAL FITTING; PRIORITY JOURNAL; REPRODUCIBILITY; SIGNAL NOISE RATIO; SIMULATION; TIBIALIS ANTERIOR MUSCLE; TISSUE STRUCTURE; VOXEL GEOMETRY;

EID: 84860477766     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2012.02.003     Document Type: Article
Times cited : (32)

References (34)
  • 2
    • 19544365262 scopus 로고    scopus 로고
    • Determination of mouse skeletal muscle architecture using three-dimensional diffusion tensor imaging
    • Heemskerk A.M., Strijkers G.J., Vilanova A., Drost M.R., Nicolay K. Determination of mouse skeletal muscle architecture using three-dimensional diffusion tensor imaging. Magn Reson Med 2005, 53:1333-1340.
    • (2005) Magn Reson Med , vol.53 , pp. 1333-1340
    • Heemskerk, A.M.1    Strijkers, G.J.2    Vilanova, A.3    Drost, M.R.4    Nicolay, K.5
  • 3
    • 34547697036 scopus 로고    scopus 로고
    • Quantitative diffusion tensor MRI-based fiber tracking of human skeletal muscle
    • Lansdown D.A., Ding Z., Wadington M., Hornberger J.L., Damon B.M. Quantitative diffusion tensor MRI-based fiber tracking of human skeletal muscle. J Appl Physiol 2007, 103:673-681.
    • (2007) J Appl Physiol , vol.103 , pp. 673-681
    • Lansdown, D.A.1    Ding, Z.2    Wadington, M.3    Hornberger, J.L.4    Damon, B.M.5
  • 4
    • 60549089070 scopus 로고    scopus 로고
    • Quantitative assessment of DTI-based muscle fiber tracking and optimal tracking parameters
    • Heemskerk A.M., Sinha T.K., Wilson K.J., Ding Z., Damon B.M. Quantitative assessment of DTI-based muscle fiber tracking and optimal tracking parameters. Magn Reson Med 2009, 61:467-472.
    • (2009) Magn Reson Med , vol.61 , pp. 467-472
    • Heemskerk, A.M.1    Sinha, T.K.2    Wilson, K.J.3    Ding, Z.4    Damon, B.M.5
  • 6
    • 33745714408 scopus 로고    scopus 로고
    • In vivo diffusion tensor imaging of the human calf muscle
    • Sinha S., Sinha U., Edgerton V.R. In vivo diffusion tensor imaging of the human calf muscle. J Magn Reson Imaging 2006, 24:182-190.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 182-190
    • Sinha, S.1    Sinha, U.2    Edgerton, V.R.3
  • 7
    • 79959601229 scopus 로고    scopus 로고
    • Reproducibility analysis of diffusion tensor indices and fiber architecture of human calf muscles in vivo at 1.5 Tesla in neutral and plantarflexed ankle positions at rest
    • Sinha S., Sinha U. Reproducibility analysis of diffusion tensor indices and fiber architecture of human calf muscles in vivo at 1.5 Tesla in neutral and plantarflexed ankle positions at rest. J Magn Reson Imaging 2011, 34:107-119.
    • (2011) J Magn Reson Imaging , vol.34 , pp. 107-119
    • Sinha, S.1    Sinha, U.2
  • 8
    • 79954575739 scopus 로고    scopus 로고
    • Human soleus muscle architecture at different ankle joint angles from magnetic resonance diffusion tensor imaging
    • Sinha U., Sinha S., Hodgson J.A., Edgerton R.V. Human soleus muscle architecture at different ankle joint angles from magnetic resonance diffusion tensor imaging. J Appl Physiol 2011, 110:807-819.
    • (2011) J Appl Physiol , vol.110 , pp. 807-819
    • Sinha, U.1    Sinha, S.2    Hodgson, J.A.3    Edgerton, R.V.4
  • 9
    • 36348937301 scopus 로고    scopus 로고
    • In vivo MR tractography of thigh muscles using diffusion imaging: initial results
    • Budzik J.F., Le Thuc V., Demondion X., Morel M., Chechin D., Cotten A. In vivo MR tractography of thigh muscles using diffusion imaging: initial results. Eur Radiol 2007, 17:3079-3085.
    • (2007) Eur Radiol , vol.17 , pp. 3079-3085
    • Budzik, J.F.1    Le Thuc, V.2    Demondion, X.3    Morel, M.4    Chechin, D.5    Cotten, A.6
  • 10
    • 63449126914 scopus 로고    scopus 로고
    • DTI-based muscle fiber tracking of the quadriceps mechanism in lateral patellar dislocation
    • Kan J.H., Heemskerk A.M., Ding Z., Gregory A., Mencio G., Spindler K., et al. DTI-based muscle fiber tracking of the quadriceps mechanism in lateral patellar dislocation. J Magn Reson Imaging 2009, 29:663-670.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 663-670
    • Kan, J.H.1    Heemskerk, A.M.2    Ding, Z.3    Gregory, A.4    Mencio, G.5    Spindler, K.6
  • 11
    • 79952439655 scopus 로고    scopus 로고
    • Extracting skeletal muscle fiber fields from noisy diffusion tensor data
    • Levin D.I., Gilles B., Madler B., Pai D.K. Extracting skeletal muscle fiber fields from noisy diffusion tensor data. Med Image Anal 2011, 15:340-353.
    • (2011) Med Image Anal , vol.15 , pp. 340-353
    • Levin, D.I.1    Gilles, B.2    Madler, B.3    Pai, D.K.4
  • 12
    • 79959216892 scopus 로고    scopus 로고
    • Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor
    • Zijta F., Froeling M., van der Paardt M., Lakeman M., Bipat S., Montauban van Swijndregt A., et al. Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor. Eur Radiol 2011, 21:1243-1249.
    • (2011) Eur Radiol , vol.21 , pp. 1243-1249
    • Zijta, F.1    Froeling, M.2    van der Paardt, M.3    Lakeman, M.4    Bipat, S.5    Montauban van Swijndregt, A.6
  • 13
    • 33644810277 scopus 로고    scopus 로고
    • Echoplanar diffusion tensor imaging of the lower leg musculature using eddy current nulled stimulated echo preparation
    • Steidle G., Schick F. Echoplanar diffusion tensor imaging of the lower leg musculature using eddy current nulled stimulated echo preparation. Magn Reson Med 2006, 55:541-548.
    • (2006) Magn Reson Med , vol.55 , pp. 541-548
    • Steidle, G.1    Schick, F.2
  • 14
    • 53549121202 scopus 로고    scopus 로고
    • Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations
    • Damon B.M. Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations. Magn Reson Med 2008, 60:934-944.
    • (2008) Magn Reson Med , vol.60 , pp. 934-944
    • Damon, B.M.1
  • 15
    • 67049158060 scopus 로고    scopus 로고
    • Diffusion tensor imaging and fiber tractography of skeletal muscle: optimization of B value for imaging at 1.5 T
    • Saupe N., White L.M., Stainsby J., Tomlinson G., Sussman M.S. Diffusion tensor imaging and fiber tractography of skeletal muscle: optimization of B value for imaging at 1.5 T. AJR Am J Roentgenol 2009, 192:W282-290.
    • (2009) AJR Am J Roentgenol , vol.192
    • Saupe, N.1    White, L.M.2    Stainsby, J.3    Tomlinson, G.4    Sussman, M.S.5
  • 16
    • 77957312485 scopus 로고    scopus 로고
    • Reproducibility of diffusion tensor imaging in human forearm muscles at 3.0 T in a clinical setting
    • Froeling M., Oudeman J., van den Berg S., Nicolay K., Maas M., Strijkers G.J., et al. Reproducibility of diffusion tensor imaging in human forearm muscles at 3.0 T in a clinical setting. Magn Reson Med 2010, 64:1182-1190.
    • (2010) Magn Reson Med , vol.64 , pp. 1182-1190
    • Froeling, M.1    Oudeman, J.2    van den Berg, S.3    Nicolay, K.4    Maas, M.5    Strijkers, G.J.6
  • 19
    • 79955766670 scopus 로고    scopus 로고
    • Combined diffusion and strain tensor MRI reveals a heterogeneous, planar pattern of strain development during isometric muscle contraction
    • Englund E.K., Elder C.P., Xu Q., Ding Z., Damon B.M. Combined diffusion and strain tensor MRI reveals a heterogeneous, planar pattern of strain development during isometric muscle contraction. Am J Physiol Regul Integr Comp Physiol 2011, 300:R1079-R1090.
    • (2011) Am J Physiol Regul Integr Comp Physiol , vol.300
    • Englund, E.K.1    Elder, C.P.2    Xu, Q.3    Ding, Z.4    Damon, B.M.5
  • 20
    • 43549123266 scopus 로고    scopus 로고
    • Associating the mesoscale fiber organization of the tongue with local strain rate during swallowing
    • Felton S.M., Gaige T.A., Benner T., Wang R., Reese T.G., Wedeen V.J., et al. Associating the mesoscale fiber organization of the tongue with local strain rate during swallowing. J Biomech 2008, 41:1782-1789.
    • (2008) J Biomech , vol.41 , pp. 1782-1789
    • Felton, S.M.1    Gaige, T.A.2    Benner, T.3    Wang, R.4    Reese, T.G.5    Wedeen, V.J.6
  • 21
    • 13844294050 scopus 로고    scopus 로고
    • A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii
    • Blemker S.S., Pinsky P.M., Delp S.L. A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii. J Biomech 2005, 38:657-665.
    • (2005) J Biomech , vol.38 , pp. 657-665
    • Blemker, S.S.1    Pinsky, P.M.2    Delp, S.L.3
  • 23
    • 0027926005 scopus 로고
    • Modelling the pressure and force equilibrium in unipennate muscles with in-line tendons
    • Van Leeuwen J.L., Spoor C.W. Modelling the pressure and force equilibrium in unipennate muscles with in-line tendons. Philos Trans R Soc Lond B Biol Sci 1993, 342:321-333.
    • (1993) Philos Trans R Soc Lond B Biol Sci , vol.342 , pp. 321-333
    • Van Leeuwen, J.L.1    Spoor, C.W.2
  • 24
    • 1542345718 scopus 로고    scopus 로고
    • Relationship between muscle architectural features and oxygenation status determined by near infrared device
    • Miura H., McCully K., Nioka S., Chance B. Relationship between muscle architectural features and oxygenation status determined by near infrared device. Eur J Appl Physiol 2004, 91:273-278.
    • (2004) Eur J Appl Physiol , vol.91 , pp. 273-278
    • Miura, H.1    McCully, K.2    Nioka, S.3    Chance, B.4
  • 25
    • 0036089873 scopus 로고    scopus 로고
    • In vivo determination of fascicle curvature in contracting human skeletal muscles
    • Muramatsu T., Muraoka T., Kawakami Y., Shibayama A., Fukunaga T. In vivo determination of fascicle curvature in contracting human skeletal muscles. J Appl Physiol 2002, 92:129-134.
    • (2002) J Appl Physiol , vol.92 , pp. 129-134
    • Muramatsu, T.1    Muraoka, T.2    Kawakami, Y.3    Shibayama, A.4    Fukunaga, T.5
  • 26
    • 0032783211 scopus 로고    scopus 로고
    • Non-invasive assessment of axonal fiber connectivity in the human brain via diffusion tensor MRI
    • Jones D.K., Simmons A., Williams S.C., Horsfield M.A. Non-invasive assessment of axonal fiber connectivity in the human brain via diffusion tensor MRI. Magn Reson Med 1999, 42:37-41.
    • (1999) Magn Reson Med , vol.42 , pp. 37-41
    • Jones, D.K.1    Simmons, A.2    Williams, S.C.3    Horsfield, M.A.4
  • 28
    • 0037381788 scopus 로고    scopus 로고
    • Classification and quantification of neuronal fiber pathways using diffusion tensor MRI
    • Ding Z., Gore J.C., Anderson A.W. Classification and quantification of neuronal fiber pathways using diffusion tensor MRI. Magn Reson Med 2003, 49:716-721.
    • (2003) Magn Reson Med , vol.49 , pp. 716-721
    • Ding, Z.1    Gore, J.C.2    Anderson, A.W.3
  • 30
    • 0032835247 scopus 로고    scopus 로고
    • Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
    • Jones D.K., Horsfield M.A., Simmons A. Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn Reson Med 1999, 42:515-525.
    • (1999) Magn Reson Med , vol.42 , pp. 515-525
    • Jones, D.K.1    Horsfield, M.A.2    Simmons, A.3
  • 31
    • 0030162959 scopus 로고    scopus 로고
    • Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI
    • Basser P.J., Pierpaoli C. Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. J Magn Reson B 1996, 111:209-219.
    • (1996) J Magn Reson B , vol.111 , pp. 209-219
    • Basser, P.J.1    Pierpaoli, C.2
  • 33
    • 84860441497 scopus 로고    scopus 로고
    • Wolfram, Inc., Champaign, IL
    • Mathworld W. Curvature 2011, Wolfram, Inc., Champaign, IL. http://mathworld.wolfram.com/Curvature.html.
    • (2011) Curvature
    • Mathworld, W.1
  • 34
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.