-
1
-
-
78651338445
-
Standards of medical care in diabetes-2011
-
Association A.D.
-
A. D. Association, "Standards of medical care in diabetes-2011," Diabetes Care, vol. 34, no. 1, pp. S11-S61, 2011
-
(2011)
Diabetes Care
, vol.34
, Issue.1
-
-
-
2
-
-
44849086395
-
Continuous glucose monitoring: The future of diabetes management
-
DOI 10.2337/diaspect.21.2.112
-
M. R. Burge, S. Mitchell, A. Sawyer, and D. S. Schade, "Continuous glucose monitoring: The future of diabetes management," Diabetes Spectr., vol. 21, no. 2, pp. 112-119, 2008 (Pubitemid 351792954)
-
(2008)
Diabetes Spectrum
, vol.21
, Issue.2
, pp. 112-119
-
-
Burge, M.R.1
Mitchell, S.2
Sawyer, A.3
Schade, D.S.4
-
3
-
-
18044367556
-
Biosensors for real-time in vivo measurements
-
DOI 10.1016/j.bios.2004.12.003, 20th Anniversary of Biosendors and Bioelectronics
-
G. S. Wilson and R. Gifford, "Biosensors for real-time in vivo measurements," Biosens. Bioelectron., vol. 20, no. 12, pp. 2388-2403, 2005 (Pubitemid 40602179)
-
(2005)
Biosensors and Bioelectronics
, vol.20
, Issue.12
, pp. 2388-2403
-
-
Wilson, G.S.1
Gifford, R.2
-
4
-
-
40449109054
-
Electrochemical glucose biosensors
-
DOI 10.1021/cr068123a
-
J. Wang, "Electrochemical glucose biosensors," Chem. Rev., vol. 108, no. 2, pp. 814-825, 2007 (Pubitemid 351344456)
-
(2008)
Chemical Reviews
, vol.108
, Issue.2
, pp. 814-825
-
-
Wang, J.1
-
5
-
-
80054998122
-
Optical methods for sensing glucose
-
M.-S. Steiner, A. Duerkop, and O. S. Wolfbeis, "Optical methods for sensing glucose," Chem. Soc. Rev., vol. 40, no. 9, pp. 4805-4839, 2011
-
(2011)
Chem. Soc. Rev.
, vol.40
, Issue.9
, pp. 4805-4839
-
-
Steiner, M.-S.1
Duerkop, A.2
Wolfbeis, O.S.3
-
6
-
-
0033624437
-
Optical glucose sensing in biological fluids: An overview
-
DOI 10.1117/1.429962
-
R. McNichols and G. Coté, "Optical glucose sensing in biological fluids: An overview," J. Biomed. Opt., vol. 5, no. 1, pp. 5-16, 2000 (Pubitemid 30556694)
-
(2000)
Journal of Biomedical Optics
, vol.5
, Issue.1
, pp. 5-16
-
-
McNichols, R.J.1
Cote, G.L.2
-
7
-
-
34247134514
-
Non-invasive glucose monitoring: Assessment of technologies and devices according to quantitative criteria
-
DOI 10.1016/j.diabres.2006.10.027, PII S0168822706004931
-
A. Tura, A. Maran, and G. Pacini, "Non-invasive glucose monitoring: Assessment of technologies and devices according to quantitative criteria," Diabetes Res. Clinical Pract., vol. 77, no. 1, pp. 16-40, 2007 (Pubitemid 46590478)
-
(2007)
Diabetes Research and Clinical Practice
, vol.77
, Issue.1
, pp. 16-40
-
-
Tura, A.1
Maran, A.2
Pacini, G.3
-
8
-
-
6044275963
-
Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium
-
DOI 10.1089/dia.2004.6.660
-
O. S. Khalil, "Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium," Diabetes Technol. Therapeutics, vol. 6, no. 5, pp. 660-697, 2004 (Pubitemid 39383073)
-
(2004)
Diabetes Technology and Therapeutics
, vol.6
, Issue.5
, pp. 660-697
-
-
Khalil, O.S.1
-
9
-
-
0032823886
-
Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy
-
S. F. Malin, T. L. Ruchti, T. B. Blank, S. N. Thennadil, and S. L. Monfre, "Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy," Clinical Chem., vol. 45, no. 9, pp. 1651-1658, 1999 (Pubitemid 29419031)
-
(1999)
Clinical Chemistry
, vol.45
, Issue.9
, pp. 1651-1658
-
-
Malin, S.F.1
Ruchti, T.L.2
Blank, T.B.3
Thennadil, S.N.4
Monfre, S.L.5
-
10
-
-
26444554176
-
Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy
-
DOI 10.1021/ac0504161
-
A. K. Amerov, J. Chen, G. W. Small, and M. A. Arnold, "Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy," Anal. Chem., vol. 77, no. 14, pp. 4587-4594, 2005 (Pubitemid 41542282)
-
(2005)
Analytical Chemistry
, vol.77
, Issue.14
, pp. 4587-4594
-
-
Amerov, A.K.1
Chen, J.2
Small, G.W.3
Arnold, M.A.4
-
11
-
-
0346731180
-
A Glucose Biosensor Based on Surface-Enhanced Raman Scattering: Improved Partition Layer, Temporal Stability, Reversibility, and Resistance to Serum Protein Interference
-
DOI 10.1021/ac035134k
-
C. R. Yonzon, C. L. Haynes, X. Zhang, R. P. Van Duyne, "A glucose biosensor based on surface-enhanced raman scattering: Improved partition layer, temporal stability, reversibility, and resistance to serum protein interference," Anal. Chem., vol. 76, no. 1, pp. 78-85, 2003 (Pubitemid 38040635)
-
(2004)
Analytical Chemistry
, vol.76
, Issue.1
, pp. 78-85
-
-
Yonzon, C.R.1
Haynes, C.L.2
Zhang, X.3
Walsh Jr., J.T.4
Van Duyne, R.P.5
-
12
-
-
0033968170
-
Prospects for in vivo Raman spectroscopy
-
E. B. Hanlon, R. Manoharan, T. W. Koo, K. E. Shafer, J. T. Motz, M. Fitzmaurice, J. R. Kramer, I. Itzkan, R. R. Dasari, and M. S. Feld, "Prospects for in vivo Raman spectroscopy," Phys. Med. Biol., vol. 45, no. 2, pp. R1-59, 2000
-
(2000)
Phys. Med. Biol.
, vol.45
, Issue.2
-
-
Hanlon, E.B.1
Manoharan, R.2
Koo, T.W.3
Shafer, K.E.4
Motz, J.T.5
Fitzmaurice, M.6
Kramer, J.R.7
Itzkan, I.8
Dasari, R.R.9
Feld, M.S.10
-
13
-
-
0020077396
-
Noninvasive glucose monitoring of the aqueous humor of the eye: Part I. Measurement of very small optical rotations
-
B. Rabinovitch, W. F. March, and R. L. Adams, "Noninvasive glucose monitoring of the aqueous humor of the Eye: Part I. Measurement of very small optical rotations," Diabetes Care, vol. 5, no. 3, pp. 254-258, 1982 (Pubitemid 12117175)
-
(1982)
Diabetes Care
, vol.5
, Issue.3
, pp. 254-258
-
-
Rabinovitch, B.1
March, W.F.2
Adams, R.L.3
-
14
-
-
10844238917
-
Non-invasive polarimetric measurement of glucose concentration in the anterior chamber of the eye
-
DOI 10.1007/s00417-004-1031-7
-
R. Rawer, W. Stork, and C. F. Kreiner, "Non-invasive polarimetric measurement of glucose concentration in the anterior chamber of the eye," Graefe's Archive Clinical Experim. Ophthalmol., vol. 242, no. 12, pp. 1017-1023, 2004 (Pubitemid 40003956)
-
(2004)
Graefe's Archive for Clinical and Experimental Ophthalmology
, vol.242
, Issue.12
, pp. 1017-1023
-
-
Rawer, R.1
Stork, W.2
Kreiner, C.F.3
-
15
-
-
0038628894
-
Noninvasive blood glucose monitoring with optical coherence tomography: A pilot study in human subjects
-
DOI 10.2337/diacare.25.12.2263
-
K. V. Larin, M. S. Eledrisi, M. Motamedi, and R. O. Esenaliev, "Noninvasive blood glucose monitoring with optical coherence tomography," Diabetes Care, vol. 25, no. 12, pp. 2263-2267, 2002 (Pubitemid 41071038)
-
(2002)
Diabetes Care
, vol.25
, Issue.12
, pp. 2263-2267
-
-
Larin, K.V.1
Eledrisi, M.S.2
Motamedi, M.3
Esenaliev, R.O.4
-
16
-
-
0000186093
-
Noninvasive monitoring of glucose concentration with optical coherence tomography
-
R. O. Esenaliev, K. V. Larin, I. V. Larina, and M. Motamedi, "Noninvasive monitoring of glucose concentration with optical coherence tomography," Opt. Lett., vol. 26, no. 13, pp. 992-994, 2001 (Pubitemid 33693170)
-
(2001)
Optics Letters
, vol.26
, Issue.13
, pp. 992-994
-
-
Esenaliev, R.O.1
Larin, K.V.2
Larina, I.V.3
Motamedi, M.4
-
17
-
-
0037534148
-
Precision of measurement of tissue optical properties with optical coherence tomography
-
A. I. Kholodnykh, I. Y. Petrova, K. V. Larin, M. Motamedi, and R. O. Esenaliev, "Precision of measurement of tissue optical properties with optical coherence tomography," Appl. Opt., vol. 42, no. 16, pp. 3027-3037, 2003
-
(2003)
Appl. Opt.
, vol.42
, Issue.16
, pp. 3027-3037
-
-
Kholodnykh, A.I.1
Petrova, I.Y.2
Larin, K.V.3
Motamedi, M.4
Esenaliev, R.O.5
-
18
-
-
0038119770
-
Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: A pilot study
-
DOI 10.1088/0031-9155/48/10/310, PII S0031915503587954
-
K. V. Larin, M. Motamedi, T. V. Ashitkov, and R. O. Esenaliev, "Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: A pilot study," Phys. Med. Biol., vol. 48, no. 10, pp. 1371-1390, 2003 (Pubitemid 36700471)
-
(2003)
Physics in Medicine and Biology
, vol.48
, Issue.10
, pp. 1371-1390
-
-
Larin, K.V.1
Motamedi, M.2
Ashitkov, T.V.3
Esenaliev, R.O.4
-
19
-
-
0001393616
-
Determination of glucose in blood based on the intrinsic fluorescence of glucose oxidase
-
J. F. Sierra, J. Galban, and J. R. Castillo, "Determination of glucose in blood based on the intrinsic fluorescence of glucose oxidase," Anal. Chem., vol. 69, no. 8, pp. 1471-1476, 1997
-
(1997)
Anal. Chem.
, vol.69
, Issue.8
, pp. 1471-1476
-
-
Sierra, J.F.1
Galban, J.2
Castillo, J.R.3
-
20
-
-
36849043512
-
Glucose determination by means of steadystate and time-course UV fluorescence in free or immobilized glucose oxidase
-
P. De Luca, M. Lepore, M. Portaccio, R. Esposito, S. Rossi, U. Bencivenga, and D. G. Mita, "Glucose determination by means of steadystate and time-course UV fluorescence in free or immobilized glucose oxidase," Sensors, vol. 7, no. 11, pp. 2612-2625, 2007
-
(2007)
Sensors
, vol.7
, Issue.11
, pp. 2612-2625
-
-
De Luca, P.1
Lepore, M.2
Portaccio, M.3
Esposito, R.4
Rossi, S.5
Bencivenga, U.6
Mita, D.G.7
-
21
-
-
37049067124
-
Novel photoinduced electron-transfer sensor for saccharides based on the interaction of boronic acid and amine
-
Jan.
-
T. D. James, K. R. A. S. Sandanayake, and S. Shinkai, "Novel photoinduced electron-transfer sensor for saccharides based on the interaction of boronic acid and amine," J. Chem. Soc., Chem. Commun., vol. 4, pp. 477-478, Jan. 1994
-
(1994)
J. Chem. Soc., Chem. Commun.
, vol.4
, pp. 477-478
-
-
James, T.D.1
Sandanayake, K.R.A.S.2
Shinkai, S.3
-
22
-
-
0033612320
-
A new glucoseselective fluorescent bisboronic acid. First report of strong -Furanose complexation in aqueous solution at physiological pH1
-
H. Eggert, J. Frederiksen, C. Morin, and J. C. Norrild, "A new glucoseselective fluorescent bisboronic acid. first report of strong -Furanose complexation in aqueous solution at physiological pH1," J. Organic Chem., vol. 64, no. 11, pp. 3846-3852, 1999
-
(1999)
J. Organic Chem.
, vol.64
, Issue.11
, pp. 3846-3852
-
-
Eggert, H.1
Frederiksen, J.2
Morin, C.3
Norrild, J.C.4
-
24
-
-
0020037173
-
Affinity sensor: A new technique for developing implantable sensors for glucose and other metabolites
-
J. S. Schultz, S. Mansouri, and I. J. Goldstein, "Affinity sensor: A new technique for developing implantable sensors for glucose and other metabolites," Diabetes Care, vol. 5, no. 3, pp. 245-253, 1982 (Pubitemid 12117174)
-
(1982)
Diabetes Care
, vol.5
, Issue.3
, pp. 245-253
-
-
Schultz, J.S.1
Mansouri, S.2
Goldstein, I.J.3
-
25
-
-
84966172549
-
A miniature optical glucose sensor based on affinity binding
-
S. Mansouri and J. S. Schultz, "A miniature optical glucose sensor based on affinity binding," Nat. Biotechnol., vol. 2, no. 10, pp. 885-890, 1984
-
(1984)
Nat. Biotechnol.
, vol.2
, Issue.10
, pp. 885-890
-
-
Mansouri, S.1
Schultz, J.S.2
-
26
-
-
33748704477
-
Thermostable proteins as probe for the design of advanced fluorescence biosensors
-
DOI 10.1007/s11157-006-0009-9
-
M. Champdor, M. Staiano, V. Aurilia, O. V. Stepanenko, A. Parracino, M. Rossi, and S. D'Auria, "Thermostable proteins as probe for the design of advanced fluorescence biosensors," Rev. Environ. Sci. Biotechnol., vol. 5, nos. 2-3, pp. 233-242, 2006 (Pubitemid 44394689)
-
(2006)
Re-views in Environmental Science and Biotechnology
, vol.5
, Issue.2-3
, pp. 233-242
-
-
De Champdore, M.1
Staiano, M.2
Aurilia, V.3
Stepanenko, O.V.4
Parracino, A.5
Rossi, M.6
D'Auria, S.7
-
27
-
-
45849100885
-
Engineering of ligand specificity of periplasmic binding protein for glucose sensing
-
A. Sakaguchi-Mikami, A. Taneoka, R. Yamoto, S. Ferri, and K. Sode, "Engineering of ligand specificity of periplasmic binding protein for glucose sensing," Biotechnol. Lett., vol. 30, no. 8, pp. 1453-1460, 2008
-
(2008)
Biotechnol. Lett.
, vol.30
, Issue.8
, pp. 1453-1460
-
-
Sakaguchi-Mikami, A.1
Taneoka, A.2
Yamoto, R.3
Ferri, S.4
Sode, K.5
-
28
-
-
33747349486
-
Concanavalin A for in vivo glucose sensing: A biotoxicity review
-
DOI 10.1016/j.bios.2006.01.008, PII S0956566306000297
-
R. Ballerstadt, C. Evans, R. McNichols, A. Gowda, "Concanavalin A for in vivo glucose sensing: A biotoxicity review," Biosens. Bioelectron., vol. 22, no. 2, pp. 275-284, 2006 (Pubitemid 44247619)
-
(2006)
Biosensors and Bioelectronics
, vol.22
, Issue.2
, pp. 275-284
-
-
Ballerstadt, R.1
Evans, C.2
McNichols, R.3
Gowda, A.4
-
29
-
-
0034282501
-
A fluorescence affinity hollow fiber sensor for continuous transdermal glucose monitoring
-
R. Ballerstadt and J. S. Schultz, "A fluorescence affinity hollow fiber sensor for continuous transdermal glucose monitoring," Anal. Chem., vol. 72, no. 17, pp. 4185-4192, 2000
-
(2000)
Anal. Chem.
, vol.72
, Issue.17
, pp. 4185-4192
-
-
Ballerstadt, R.1
Schultz, J.S.2
-
30
-
-
1042275717
-
In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring
-
DOI 10.1016/j.bios.2003.08.019
-
R. Ballerstadt, A. Polak, A. Beuhler, and J. Frye, "In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring," Biosens. Bioelectron., vol. 19, no. 8, pp. 905-914, 2004 (Pubitemid 38201341)
-
(2004)
Biosensors and Bioelectronics
, vol.19
, Issue.8
, pp. 905-914
-
-
Ballerstadt, R.1
Polak, A.2
Beuhler, A.3
Frye, J.4
-
31
-
-
33748423435
-
In vivo performance evaluation of a transdermal near-infrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring
-
DOI 10.1089/dia.2006.8.296
-
R. Ballerstadt, C. Evans, A. Gowda, and R. McNichols, "In vivo performance evaluation of a transdermal near-infrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring," Diabetes Technol. Therapeutics, vol. 8, no. 3, pp. 296-311, 2006 (Pubitemid 46100524)
-
(2006)
Diabetes Technology and Therapeutics
, vol.8
, Issue.3
, pp. 296-311
-
-
Ballerstadt, R.1
Evans, C.2
Gowda, A.3
McNichols, R.4
-
32
-
-
34548811952
-
Affinity-based turbidity sensor for glucose monitoring by optical coherence tomography: Toward the development of an implantable sensor
-
DOI 10.1021/ac0707434
-
R. Ballerstadt, A. Kholodnykh, C. Evans, A. Gowda, A. Boretsky, and R. McNichols, "Affinity-based turbidity sensor for glucose monitoring by optical coherence tomography: Toward the development of an implantable sensor," Anal. Chem., vol. 79, no. 18, pp. 6965-6974, 2007 (Pubitemid 47438675)
-
(2007)
Analytical Chemistry
, vol.79
, Issue.18
, pp. 6965-6974
-
-
Ballerstadt, R.1
Kholodnykh, A.2
Evans, C.3
Boretsky, A.4
Motamedi, M.5
Gowda, A.6
McNichols, R.7
-
33
-
-
84255172520
-
Suspended, micron-scale corner cube retroreflectors as ultra-bright optical labels
-
T. Sherlock, A. Nasrullah, J. Litvinov, E. Cacao, J. Knoop, S. Kemper, K. Kourentzi, A. Kar, P. Ruchhoeft, and R. Willson, "Suspended, micron-scale corner cube retroreflectors as ultra-bright optical labels," J. Vacuum Sci. Technol. B, Microelectron. Nanometer Struct., vol. 29, no. 6, pp. 06FA01-1-06FA01-5, 2011
-
(2011)
J. Vacuum Sci. Technol. B, Microelectron. Nanometer Struct.
, vol.29
, Issue.6
-
-
Sherlock, T.1
Nasrullah, A.2
Litvinov, J.3
Cacao, E.4
Knoop, J.5
Kemper, S.6
Kourentzi, K.7
Kar, A.8
Ruchhoeft, P.9
Willson, R.10
-
34
-
-
0346981999
-
Influencing receptor-ligand binding mechanisms with multivalent ligand architecture
-
DOI 10.1021/ja027184x
-
J. E. Gestwicki, C. W. Cairo, L. E. Strong, K. A. Oetjen, and L. L. Kiessling, "Influencing receptor-ligand binding mechanisms with multivalent ligand architecture," J. Amer. Chem. Soc., vol. 124, no. 50, pp. 14922-14933, 2002 (Pubitemid 36014100)
-
(2002)
Journal of the American Chemical Society
, vol.124
, Issue.50
, pp. 14922-14933
-
-
Gestwicki, J.E.1
Cairo, C.W.2
Strong, L.E.3
Oetjen, K.A.4
Kiessling, L.L.5
-
35
-
-
84863391625
-
Depth-resolved imaging and detection of micro-retroreflectors within biological tissue using optical coherence tomography
-
S. N. Ivers, S. A. Baranov, T. Sherlock, K. Kourentzi, P. Ruchhoeft, R. Willson, and K. V. Larin, "Depth-resolved imaging and detection of micro-retroreflectors within biological tissue using optical coherence tomography," Biomed. Opt. Exp., vol. 1, no. 2, pp. 367-377, 2010
-
(2010)
Biomed. Opt. Exp.
, vol.1
, Issue.2
, pp. 367-377
-
-
Ivers, S.N.1
Baranov, S.A.2
Sherlock, T.3
Kourentzi, K.4
Ruchhoeft, P.5
Willson, R.6
Larin, K.V.7
-
37
-
-
0033327503
-
Optical Coherence Tomography (OCT): A review
-
DOI 10.1109/2944.796348
-
J. M. Schmitt, "Optical coherence tomography (OCT): A review," IEEE J. Sel. Topics Quantum Electron., vol. 5, no. 4, pp. 1205-1215, Jul. 1999 (Pubitemid 30544923)
-
(1999)
IEEE Journal on Selected Topics in Quantum Electronics
, vol.5
, Issue.4
, pp. 1205-1215
-
-
Schmitt, J.M.1
-
38
-
-
76749159949
-
Magneto-optical biosensing platform based on light scattering from self-assembled chains of functionalized rotating magnetic beads
-
S. Y. Park, H. Handa, and A. Sandhu, "Magneto-optical biosensing platform based on light scattering from self-assembled chains of functionalized rotating magnetic beads," Nano Lett., vol. 10, no. 2, pp. 446-451, 2009.
-
(2009)
Nano Lett.
, vol.10
, Issue.2
, pp. 446-451
-
-
Park, S.Y.1
Handa, H.2
Sandhu, A.3
|