-
1
-
-
34247113966
-
-
The Future of Diabetes Diagnostics: Monitoring & Management in 2010, PJB Publications USA Inc., New York, NY, 2001.
-
-
-
-
2
-
-
34247139947
-
-
Pipeline Insight: Diabetes Drug Delivery and Diagnostics-Towards the Non-invasive Revolution, Datamonitor, London, UK, 2003.
-
-
-
-
3
-
-
34247140386
-
-
Diabetes and Diabetic Complications: Major World Markets, second ed., Kalorama Information, New York, NY, 2005.
-
-
-
-
4
-
-
34247122081
-
-
Noninvasive Glucose Monitors-Technology, Players and Prospects, Greystone Associates, Amherst, NH, 2004.
-
-
-
-
5
-
-
6044275963
-
Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium
-
Khalil O.S. Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. Diabetes Technol. Ther. 6 (2004) 660-697
-
(2004)
Diabetes Technol. Ther.
, vol.6
, pp. 660-697
-
-
Khalil, O.S.1
-
6
-
-
14844345011
-
Noninvasive and minimally invasive methods for transdermal glucose monitoring
-
Sieg A., Guy R.H., and Delgado-Charro M.B. Noninvasive and minimally invasive methods for transdermal glucose monitoring. Diabetes Technol. Ther. 7 (2005) 174-197
-
(2005)
Diabetes Technol. Ther.
, vol.7
, pp. 174-197
-
-
Sieg, A.1
Guy, R.H.2
Delgado-Charro, M.B.3
-
7
-
-
34247153680
-
-
www.mendosa.com/meters.htm, Last checked 22/03/2006.
-
-
-
-
8
-
-
0036623160
-
Health technology assessment for medical devices in Europe. What must be considered
-
Siebert M., Clauss L.C., Carlisle M., Casteels B., de Jong P., Kreuzer M., et al. Health technology assessment for medical devices in Europe. What must be considered. Int. J. Technol. Assess. Health Care 18 (2002) 733-740
-
(2002)
Int. J. Technol. Assess. Health Care
, vol.18
, pp. 733-740
-
-
Siebert, M.1
Clauss, L.C.2
Carlisle, M.3
Casteels, B.4
de Jong, P.5
Kreuzer, M.6
-
9
-
-
0032823886
-
Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy
-
Malin S.F., Ruchti T.L., Blank T.B., Thennadil S.N., and Monfre S.L. Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy. Clin. Chem. 45 (1999) 1651-1658
-
(1999)
Clin. Chem.
, vol.45
, pp. 1651-1658
-
-
Malin, S.F.1
Ruchti, T.L.2
Blank, T.B.3
Thennadil, S.N.4
Monfre, S.L.5
-
10
-
-
34247140741
-
-
R.W. Waynant, V.M. Chenault, Overview of non-invasive fluid glucose measurement using optical techniques to maintain glucose control in diabetes mellitus (http://www.ieee.org/organizations/pubs/newsletters/leos/apr98/overview.htm. Last checked 22/03/2006).
-
-
-
-
11
-
-
0031920445
-
Insulin-induced vasodilatation: physiology or pharmacology?
-
Yki-Jarvinen H., and Utriainen T. Insulin-induced vasodilatation: physiology or pharmacology?. Diabetologia 41 (1998) 369-379
-
(1998)
Diabetologia
, vol.41
, pp. 369-379
-
-
Yki-Jarvinen, H.1
Utriainen, T.2
-
12
-
-
0036354936
-
Acute hyperglycemia and hyperinsulinemia enhance vasodilatation in Type 1 diabetes mellitus without increasing capillary permeability and inducing endothelial dysfunction
-
Oomen P.H., Kant G.D., Dullaart R.P., Reitsma W.D., and Smit A.J. Acute hyperglycemia and hyperinsulinemia enhance vasodilatation in Type 1 diabetes mellitus without increasing capillary permeability and inducing endothelial dysfunction. Microvasc. Res. 63 (2002) 1-9
-
(2002)
Microvasc. Res.
, vol.63
, pp. 1-9
-
-
Oomen, P.H.1
Kant, G.D.2
Dullaart, R.P.3
Reitsma, W.D.4
Smit, A.J.5
-
14
-
-
0032997958
-
Skin collagen glycation, glycoxidation, and crosslinking are lower in subjects with long-term intensive versus conventional therapy of Type 1 diabetes: relevance of glycated collagen products versus HbA1c as markers of diabetic complications. DCCT Skin Collagen Ancillary Study Group. Diabetes Control and Complications Trial
-
Monnier V.M., Bautista O., Kenny D., Sell D.R., Fogarty J., Dahms W., et al. Skin collagen glycation, glycoxidation, and crosslinking are lower in subjects with long-term intensive versus conventional therapy of Type 1 diabetes: relevance of glycated collagen products versus HbA1c as markers of diabetic complications. DCCT Skin Collagen Ancillary Study Group. Diabetes Control and Complications Trial. Diabetes 48 (1999) 870-880
-
(1999)
Diabetes
, vol.48
, pp. 870-880
-
-
Monnier, V.M.1
Bautista, O.2
Kenny, D.3
Sell, D.R.4
Fogarty, J.5
Dahms, W.6
-
15
-
-
0141867692
-
Near-infrared thermo-optical response of the localized reflectance of intact diabetic and nondiabetic human skin
-
Yeh S.J., Khalil O.S., Hanna C.F., and Kantor S. Near-infrared thermo-optical response of the localized reflectance of intact diabetic and nondiabetic human skin. J. Biomed. Opt. 8 (2003) 534-544
-
(2003)
J. Biomed. Opt.
, vol.8
, pp. 534-544
-
-
Yeh, S.J.1
Khalil, O.S.2
Hanna, C.F.3
Kantor, S.4
-
16
-
-
0036525878
-
Properties of erythrocyte light refraction in diabetic patients
-
Mazarevica G., Freivalds T., and Jurka A. Properties of erythrocyte light refraction in diabetic patients. J. Biomed. Opt. 7 (2002) 244-247
-
(2002)
J. Biomed. Opt.
, vol.7
, pp. 244-247
-
-
Mazarevica, G.1
Freivalds, T.2
Jurka, A.3
-
17
-
-
0035671333
-
Image analysis for the detection of increased erythrocyte, leukocyte and platelet adhesiveness/aggregation in the peripheral blood of patients with diabetes mellitus
-
Fusman R., Rotstein R., Elishkewich K., Zeltser D., Cohen S., and Kofler M. Image analysis for the detection of increased erythrocyte, leukocyte and platelet adhesiveness/aggregation in the peripheral blood of patients with diabetes mellitus. Acta Diabetol. 38 (2001) 129-134
-
(2001)
Acta Diabetol.
, vol.38
, pp. 129-134
-
-
Fusman, R.1
Rotstein, R.2
Elishkewich, K.3
Zeltser, D.4
Cohen, S.5
Kofler, M.6
-
18
-
-
84891711974
-
Non-invasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip
-
Marbach R., Koschinsky T., Gries F.A., and Heise H.M. Non-invasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip. Appl. Spect. 47 (1993) 875-881
-
(1993)
Appl. Spect.
, vol.47
, pp. 875-881
-
-
Marbach, R.1
Koschinsky, T.2
Gries, F.A.3
Heise, H.M.4
-
19
-
-
0027624283
-
Non-invasive measurement of blood glucose concentrations by analyzing Fourier transform infrared absorbance spectra through oral mucosa
-
Kajiwara K., Uemura T., Kishikawa H., Nishida K., Hashiguchi Y., Uehara M., et al. Non-invasive measurement of blood glucose concentrations by analyzing Fourier transform infrared absorbance spectra through oral mucosa. Med. Biol. Eng. Comput. 31 (1993) S17-S22
-
(1993)
Med. Biol. Eng. Comput.
, vol.31
-
-
Kajiwara, K.1
Uemura, T.2
Kishikawa, H.3
Nishida, K.4
Hashiguchi, Y.5
Uehara, M.6
-
20
-
-
0035095542
-
Attenuated total reflection-Fourier transform infrared spectroscopy as a possible method to investigate biophysical parameters of stratum corneum in vivo
-
Brancaleon L., Bamberg M.P., Sakamaki T., and Kollias N. Attenuated total reflection-Fourier transform infrared spectroscopy as a possible method to investigate biophysical parameters of stratum corneum in vivo. J. Invest. Dermatol. 116 (2001) 380-386
-
(2001)
J. Invest. Dermatol.
, vol.116
, pp. 380-386
-
-
Brancaleon, L.1
Bamberg, M.P.2
Sakamaki, T.3
Kollias, N.4
-
21
-
-
18344404414
-
Human oral mucosa studies with varying blood glucose concentration by non-invasive ATR-FT-IR-spectroscopy
-
Heise H.M., and Marbach R. Human oral mucosa studies with varying blood glucose concentration by non-invasive ATR-FT-IR-spectroscopy. Cell. Mol. Biol. (Noisy-le-grand) 44 (1998) 899-912
-
(1998)
Cell. Mol. Biol. (Noisy-le-grand)
, vol.44
, pp. 899-912
-
-
Heise, H.M.1
Marbach, R.2
-
22
-
-
0038628894
-
Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects
-
Larin K.V., Eledrisi M.S., Motamedi M., and Esenaliev R.O. Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects. Diab. Care 25 (2002) 2263-2267
-
(2002)
Diab. Care
, vol.25
, pp. 2263-2267
-
-
Larin, K.V.1
Eledrisi, M.S.2
Motamedi, M.3
Esenaliev, R.O.4
-
23
-
-
0034045350
-
Noninvasive glucose measurement by monitoring of scattering coefficient during oral glucose tolerance tests. Non-Invasive Task Force
-
Heinemann L., Kramer U., Klotzer H.M., Hein M., Volz D., Hermann M., et al. Noninvasive glucose measurement by monitoring of scattering coefficient during oral glucose tolerance tests. Non-Invasive Task Force. Diabetes Technol. Ther. 2 (2000) 211-220
-
(2000)
Diabetes Technol. Ther.
, vol.2
, pp. 211-220
-
-
Heinemann, L.1
Kramer, U.2
Klotzer, H.M.3
Hein, M.4
Volz, D.5
Hermann, M.6
-
24
-
-
0038021219
-
Monitoring blood glucose changes in cutaneous tissue by temperature-modulated localized reflectance measurements
-
Yeh S.J., Hanna C.F., and Khalil O.S. Monitoring blood glucose changes in cutaneous tissue by temperature-modulated localized reflectance measurements. Clin. Chem. 49 (2003) 924-934
-
(2003)
Clin. Chem.
, vol.49
, pp. 924-934
-
-
Yeh, S.J.1
Hanna, C.F.2
Khalil, O.S.3
-
25
-
-
0033968170
-
Prospects for in vivo Raman spectroscopy
-
Hanlon E.B., Manoharan R., Koo T.W., Shafer K.E., Motz J.T., Fitzmaurice M., et al. Prospects for in vivo Raman spectroscopy. Phys. Med. Biol. 45 (2000) R1-R59
-
(2000)
Phys. Med. Biol.
, vol.45
-
-
Hanlon, E.B.1
Manoharan, R.2
Koo, T.W.3
Shafer, K.E.4
Motz, J.T.5
Fitzmaurice, M.6
-
26
-
-
0033140260
-
Laser-based measurement of glucose in the ocular aqueous humor: an efficacious portal for determination of serum glucose levels
-
Steffes P.G. Laser-based measurement of glucose in the ocular aqueous humor: an efficacious portal for determination of serum glucose levels. Diabetes Technol. Ther. 1 (1999) 129-133
-
(1999)
Diabetes Technol. Ther.
, vol.1
, pp. 129-133
-
-
Steffes, P.G.1
-
27
-
-
0017559256
-
Stimulated Raman spectroscopy using low-power cw lasers
-
Owyoung A., and Jones E. Stimulated Raman spectroscopy using low-power cw lasers. Opt. Lett. 1 (1977) 152-154
-
(1977)
Opt. Lett.
, vol.1
, pp. 152-154
-
-
Owyoung, A.1
Jones, E.2
-
28
-
-
34247131975
-
-
R.V. Tarr, P.G. Steffes, The non-invasive measure of d-glucose in the ocular aqueous humor using stimulated Raman spectroscopy (http://www.ieee.org/organizations/pubs/newsletters/leos/apr98/dgloucose.htm. Last checked 22/03/2006).
-
-
-
-
29
-
-
0346731180
-
A glucose biosensor based on surface-enhanced Raman scattering: improved partition layer, temporal stability, reversibility, and resistance to serum protein interference
-
Yonzon C.R., Haynes C.L., Zhang X., Walsh Jr. J.T., and Van Duyne R.P. A glucose biosensor based on surface-enhanced Raman scattering: improved partition layer, temporal stability, reversibility, and resistance to serum protein interference. Anal. Chem. 76 (2004) 78-85
-
(2004)
Anal. Chem.
, vol.76
, pp. 78-85
-
-
Yonzon, C.R.1
Haynes, C.L.2
Zhang, X.3
Walsh Jr., J.T.4
Van Duyne, R.P.5
-
30
-
-
0038649993
-
Combined in vivo confocal Raman spectroscopy and confocal microscopy of human skin
-
Caspers P.J., Lucassen G.W., and Puppels G.J. Combined in vivo confocal Raman spectroscopy and confocal microscopy of human skin. Biophys. J. 85 (2003) 572-580
-
(2003)
Biophys. J.
, vol.85
, pp. 572-580
-
-
Caspers, P.J.1
Lucassen, G.W.2
Puppels, G.J.3
-
31
-
-
0020077396
-
Noninvasive glucose monitoring of the aqueous humor of the eye: part I. Measurement of very small optical rotations
-
Rabinovitch B., March W.F., and Adams R.L. Noninvasive glucose monitoring of the aqueous humor of the eye: part I. Measurement of very small optical rotations. Diab. Care 5 (1982) 254-258
-
(1982)
Diab. Care
, vol.5
, pp. 254-258
-
-
Rabinovitch, B.1
March, W.F.2
Adams, R.L.3
-
32
-
-
34247152299
-
-
R.J. McNichols, B.D. Cameron, G.L. Coté, Development of a non-invasive polarimetric glucose sensor (http://www.ieee.org/organizations/pubs/newsletters/leos/apr98/glucosesensor.htm. Last checked 22/03/2006).
-
-
-
-
33
-
-
1342333818
-
Polarimetric methods for measurement of intra ocular glucose concentration
-
Rawer R., Stork W., and Muller-Glaser K.D. Polarimetric methods for measurement of intra ocular glucose concentration. Biomed. Tech. (Berl.) 47 Suppl. 1 (2002) 186-188
-
(2002)
Biomed. Tech. (Berl.)
, vol.47
, Issue.SUPPL. 1
, pp. 186-188
-
-
Rawer, R.1
Stork, W.2
Muller-Glaser, K.D.3
-
34
-
-
0032995738
-
Spectroscopic and clinical aspects of noninvasive glucose measurements
-
Khalil O.S. Spectroscopic and clinical aspects of noninvasive glucose measurements. Clin. Chem. 45 (1999) 165-177
-
(1999)
Clin. Chem.
, vol.45
, pp. 165-177
-
-
Khalil, O.S.1
-
35
-
-
0034944362
-
Measurement of the glucose transport time delay between the blood and aqueous humor of the eye for the eventual development of a noninvasive glucose sensor
-
Cameron B.D., Baba J.S., and Cote G.L. Measurement of the glucose transport time delay between the blood and aqueous humor of the eye for the eventual development of a noninvasive glucose sensor. Diabetes Technol. Ther. 3 (2001) 201-207
-
(2001)
Diabetes Technol. Ther.
, vol.3
, pp. 201-207
-
-
Cameron, B.D.1
Baba, J.S.2
Cote, G.L.3
-
36
-
-
0005789117
-
Measurement of the optical absorption coefficient of a liquid by use of a time-resolved photoacoustic technique
-
Shen Y., Lu Z., Spiers S., MacKenzie H.A., Ashton H.S., Hannigan J., et al. Measurement of the optical absorption coefficient of a liquid by use of a time-resolved photoacoustic technique. Appl. Opt. 39 (2000) 4007-4012
-
(2000)
Appl. Opt.
, vol.39
, pp. 4007-4012
-
-
Shen, Y.1
Lu, Z.2
Spiers, S.3
MacKenzie, H.A.4
Ashton, H.S.5
Hannigan, J.6
-
37
-
-
34247140740
-
-
http://www.integrity-app.com. Last checked 22/03/2006.
-
-
-
-
38
-
-
0032820949
-
Advances in photoacoustic noninvasive glucose testing
-
MacKenzie H.A., Ashton H.S., Spiers S., Shen Y., Freeborn S.S., Hannigan J., et al. Advances in photoacoustic noninvasive glucose testing. Clin. Chem. 45 (1999) 1587-1595
-
(1999)
Clin. Chem.
, vol.45
, pp. 1587-1595
-
-
MacKenzie, H.A.1
Ashton, H.S.2
Spiers, S.3
Shen, Y.4
Freeborn, S.S.5
Hannigan, J.6
-
39
-
-
0344034169
-
Influence of epidermal thickness, pigmentation and redness on skin autofluorescence
-
Sandby-Moller J., Poulsen T., and Wulf H.C. Influence of epidermal thickness, pigmentation and redness on skin autofluorescence. Photochem. Photobiol. 77 (2003) 616-620
-
(2003)
Photochem. Photobiol.
, vol.77
, pp. 616-620
-
-
Sandby-Moller, J.1
Poulsen, T.2
Wulf, H.C.3
-
40
-
-
33645291237
-
Initial clinical testing of a holographic non-invasive contact lens glucose sensor
-
Domschke A., March W.F., Kabilan S., and Lowe C. Initial clinical testing of a holographic non-invasive contact lens glucose sensor. Diabetes Technol. Ther. 8 (2006) 89-93
-
(2006)
Diabetes Technol. Ther.
, vol.8
, pp. 89-93
-
-
Domschke, A.1
March, W.F.2
Kabilan, S.3
Lowe, C.4
-
41
-
-
0033119151
-
Hyponatremia: evaluating the correction factor for hyperglycemia
-
Hillier T.A., Abbott R.D., and Barrett E.J. Hyponatremia: evaluating the correction factor for hyperglycemia. Am. J. Med. 106 (1999) 399-403
-
(1999)
Am. J. Med.
, vol.106
, pp. 399-403
-
-
Hillier, T.A.1
Abbott, R.D.2
Barrett, E.J.3
-
42
-
-
0033834696
-
Analysis of dielectric spectra of eukaryotic cells by computer modelling
-
Ermolina I., Polevaya Y., and Feldman Y. Analysis of dielectric spectra of eukaryotic cells by computer modelling. Eur. Biophys. J. 29 (2000) 141-145
-
(2000)
Eur. Biophys. J.
, vol.29
, pp. 141-145
-
-
Ermolina, I.1
Polevaya, Y.2
Feldman, Y.3
-
43
-
-
0033027086
-
Time domain dielectric spectroscopy study of human cells. II. Normal and malignant white blood cells
-
Polevaya Y., Ermolina I., Schlesinger M., Ginzburg B.Z., and Feldman Y. Time domain dielectric spectroscopy study of human cells. II. Normal and malignant white blood cells. Biochim. Biophys. Acta 1419 (1999) 257-271
-
(1999)
Biochim. Biophys. Acta
, vol.1419
, pp. 257-271
-
-
Polevaya, Y.1
Ermolina, I.2
Schlesinger, M.3
Ginzburg, B.Z.4
Feldman, Y.5
-
44
-
-
0242357278
-
First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
-
Caduff A., Hirt E., Feldman Y., Ali Z., and Heinemann L. First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system. Biosens. Bioelectron. 19 (2003) 209-217
-
(2003)
Biosens. Bioelectron.
, vol.19
, pp. 209-217
-
-
Caduff, A.1
Hirt, E.2
Feldman, Y.3
Ali, Z.4
Heinemann, L.5
-
45
-
-
0344873782
-
Study of a new electromagnetic sensor for glycaemia measurement: in vitro results on blood pig
-
Gourzi M., Rouane A., Guelaz R., Nadi M., and Jaspard F. Study of a new electromagnetic sensor for glycaemia measurement: in vitro results on blood pig. J. Med. Eng. Technol. 27 (2003) 276-281
-
(2003)
J. Med. Eng. Technol.
, vol.27
, pp. 276-281
-
-
Gourzi, M.1
Rouane, A.2
Guelaz, R.3
Nadi, M.4
Jaspard, F.5
-
46
-
-
12344275405
-
Non-invasive glycaemia blood measurements by electromagnetic sensor: study in static and dynamic blood circulation
-
Gourzi M., Rouane A., Guelaz R., Alavi M.S., McHugh M.B., Nadi M., et al. Non-invasive glycaemia blood measurements by electromagnetic sensor: study in static and dynamic blood circulation. J. Med. Eng. Technol. 29 (2005) 22-26
-
(2005)
J. Med. Eng. Technol.
, vol.29
, pp. 22-26
-
-
Gourzi, M.1
Rouane, A.2
Guelaz, R.3
Alavi, M.S.4
McHugh, M.B.5
Nadi, M.6
-
47
-
-
0034613001
-
A dielectric analysis of liquid and glassy solid glucose/water solutions
-
Moran G.R., Jeffrey K.R., Thomas J.M., and Stevens J.R. A dielectric analysis of liquid and glassy solid glucose/water solutions. Carbohydr. Res. 328 (2000) 573-584
-
(2000)
Carbohydr. Res.
, vol.328
, pp. 573-584
-
-
Moran, G.R.1
Jeffrey, K.R.2
Thomas, J.M.3
Stevens, J.R.4
-
48
-
-
12444301362
-
Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum
-
Gebhart S., Faupel M., Fowler R., Kapsner C., Lincoln D., McGee V., et al. Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum. Diabetes Technol. Ther. 5 (2003) 159-166
-
(2003)
Diabetes Technol. Ther.
, vol.5
, pp. 159-166
-
-
Gebhart, S.1
Faupel, M.2
Fowler, R.3
Kapsner, C.4
Lincoln, D.5
McGee, V.6
-
49
-
-
0034491769
-
Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels
-
Mitragotri S., Coleman M., Kost J., and Langer R. Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels. J. Appl. Physiol. 89 (2000) 961-966
-
(2000)
J. Appl. Physiol.
, vol.89
, pp. 961-966
-
-
Mitragotri, S.1
Coleman, M.2
Kost, J.3
Langer, R.4
-
50
-
-
0033361244
-
Application of the mixtures of experts algorithm for signal processing in a noninvasive glucose monitoring system
-
Kurnik R.T., Oliver J.J., Waterhouse S.R., Dunn T., Jayalakshmi Y., Lesho M., et al. Application of the mixtures of experts algorithm for signal processing in a noninvasive glucose monitoring system. Sens. Actuators B: Chem. 60 (1999) 19-26
-
(1999)
Sens. Actuators B: Chem.
, vol.60
, pp. 19-26
-
-
Kurnik, R.T.1
Oliver, J.J.2
Waterhouse, S.R.3
Dunn, T.4
Jayalakshmi, Y.5
Lesho, M.6
-
51
-
-
0035345431
-
Detection of hypoglycemia with the GlucoWatch biographer
-
Pitzer K.R., Desai S., Dunn T., Edelman S., Jayalakshmi Y., Kennedy J., et al. Detection of hypoglycemia with the GlucoWatch biographer. Diab. Care 24 (2001) 881-885
-
(2001)
Diab. Care
, vol.24
, pp. 881-885
-
-
Pitzer, K.R.1
Desai, S.2
Dunn, T.3
Edelman, S.4
Jayalakshmi, Y.5
Kennedy, J.6
-
52
-
-
0032882086
-
Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with Type 1 diabetes
-
Garg S.K., Potts R.O., Ackerman N.R., Fermi S.J., Tamada J.A., and Chase H.P. Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with Type 1 diabetes. Diab. Care 22 (1999) 1708-1714
-
(1999)
Diab. Care
, vol.22
, pp. 1708-1714
-
-
Garg, S.K.1
Potts, R.O.2
Ackerman, N.R.3
Fermi, S.J.4
Tamada, J.A.5
Chase, H.P.6
-
53
-
-
0033579205
-
Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team
-
Tamada J.A., Garg S., Jovanovic L., Pitzer K.R., Fermi S., and Potts R.O. Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team. JAMA 282 (1999) 1839-1844
-
(1999)
JAMA
, vol.282
, pp. 1839-1844
-
-
Tamada, J.A.1
Garg, S.2
Jovanovic, L.3
Pitzer, K.R.4
Fermi, S.5
Potts, R.O.6
-
54
-
-
0034124905
-
Effect of acetaminophen on the accuracy of glucose measurements obtained with the GlucoWatch biographer
-
Tierney M.J., Garg S., Ackerman N.R., Fermi S.J., Kennedy J., Lopatin M., et al. Effect of acetaminophen on the accuracy of glucose measurements obtained with the GlucoWatch biographer. Diabetes Technol. Ther. 2 (2000) 199-207
-
(2000)
Diabetes Technol. Ther.
, vol.2
, pp. 199-207
-
-
Tierney, M.J.1
Garg, S.2
Ackerman, N.R.3
Fermi, S.J.4
Kennedy, J.5
Lopatin, M.6
-
55
-
-
0034780892
-
Cygnus Research Team, Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes
-
Tierney M.J., Tamada J.A., Potts R.O., Jovanovic L., and Garg S. Cygnus Research Team, Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes. Biosens. Bioelectron. 16 (2001) 621-629
-
(2001)
Biosens. Bioelectron.
, vol.16
, pp. 621-629
-
-
Tierney, M.J.1
Tamada, J.A.2
Potts, R.O.3
Jovanovic, L.4
Garg, S.5
-
56
-
-
18644379515
-
Use of the GlucoWatch biographer in children and adolescents with diabetes
-
Eastman R.C., Chase H.P., Buckingham B., Hathout E.H., Fuller-Byk L., Leptien A.M.M., et al. Use of the GlucoWatch biographer in children and adolescents with diabetes. Pediatr. Diab. 3 (2002) 127-134
-
(2002)
Pediatr. Diab.
, vol.3
, pp. 127-134
-
-
Eastman, R.C.1
Chase, H.P.2
Buckingham, B.3
Hathout, E.H.4
Fuller-Byk, L.5
Leptien, A.M.M.6
-
57
-
-
0347986896
-
Use of the Cygnus GlucoWatch biographer at a diabetes camp
-
Gandrud L.M., Paguntalan H.U., Van Wyhe M.M., Kunselman B.L., Leptien A.D., Wilson D.M., et al. Use of the Cygnus GlucoWatch biographer at a diabetes camp. Pediatrics 113 (2004) 108-111
-
(2004)
Pediatrics
, vol.113
, pp. 108-111
-
-
Gandrud, L.M.1
Paguntalan, H.U.2
Van Wyhe, M.M.3
Kunselman, B.L.4
Leptien, A.D.5
Wilson, D.M.6
-
58
-
-
4344582891
-
Use of the noninvasive GlucoWatch Biographer during exercise of varying intensity
-
Nunnold T., Colberg S.R., Herriott M.T., and Somma C.T. Use of the noninvasive GlucoWatch Biographer during exercise of varying intensity. Diabetes Technol. Ther. 6 (2004) 454-462
-
(2004)
Diabetes Technol. Ther.
, vol.6
, pp. 454-462
-
-
Nunnold, T.1
Colberg, S.R.2
Herriott, M.T.3
Somma, C.T.4
-
59
-
-
3242759069
-
Noninvasive glucose monitoring by reverse iontophoresis in vivo: application of the internal standard concept
-
Sieg A., Guy R.H., and Delgado-Charro M.B. Noninvasive glucose monitoring by reverse iontophoresis in vivo: application of the internal standard concept. Clin. Chem. 50 (2004) 1383-1390
-
(2004)
Clin. Chem.
, vol.50
, pp. 1383-1390
-
-
Sieg, A.1
Guy, R.H.2
Delgado-Charro, M.B.3
-
60
-
-
4444379843
-
Rates of glucose change measured by blood glucose meter and the GlucoWatch Biographer during day, night, and around mealtimes
-
Dunn T.C., Eastman R.C., and Tamada J.A. Rates of glucose change measured by blood glucose meter and the GlucoWatch Biographer during day, night, and around mealtimes. Diabetes Care 27 (2004) 2161-2165
-
(2004)
Diabetes Care
, vol.27
, pp. 2161-2165
-
-
Dunn, T.C.1
Eastman, R.C.2
Tamada, J.A.3
-
61
-
-
6044276738
-
GlucoWatch G2 Biographer alarm reliability during hypoglycemia in children
-
Tsalikian E., Kollman C., Mauras N., Weinzimer S., Buckingham B., Xing D., et al. GlucoWatch G2 Biographer alarm reliability during hypoglycemia in children. Diabetes Technol. Ther. 6 (2004) 559-566
-
(2004)
Diabetes Technol. Ther.
, vol.6
, pp. 559-566
-
-
Tsalikian, E.1
Kollman, C.2
Mauras, N.3
Weinzimer, S.4
Buckingham, B.5
Xing, D.6
-
62
-
-
20344365604
-
Home use of the GlucoWatch G2 biographer in children with diabetes
-
Hathout E., Patel N., Southern C., Hill J., Anderson R., Sharkey J., et al. Home use of the GlucoWatch G2 biographer in children with diabetes. Pediatrics 115 (2005) 662-666
-
(2005)
Pediatrics
, vol.115
, pp. 662-666
-
-
Hathout, E.1
Patel, N.2
Southern, C.3
Hill, J.4
Anderson, R.5
Sharkey, J.6
-
63
-
-
21244434882
-
Diabetes Research in Children Network Study Gr@oup, Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in Type 1 diabetes
-
Fiallo-Scharer R. Diabetes Research in Children Network Study Gr@oup, Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in Type 1 diabetes. J. Clin. Endocrinol. Metab. 90 (2005) 3387-3391
-
(2005)
J. Clin. Endocrinol. Metab.
, vol.90
, pp. 3387-3391
-
-
Fiallo-Scharer, R.1
-
64
-
-
20544452543
-
Diabetes Research in Children Network, response to nocturnal alarms using a real-time glucose sensor
-
Buckingham B., Block J., Burdick J., Kalajian A., Kollman C., Choy M., et al. Diabetes Research in Children Network, response to nocturnal alarms using a real-time glucose sensor. Diabetes Technol. Ther. 7 (2005) 440-447
-
(2005)
Diabetes Technol. Ther.
, vol.7
, pp. 440-447
-
-
Buckingham, B.1
Block, J.2
Burdick, J.3
Kalajian, A.4
Kollman, C.5
Choy, M.6
-
65
-
-
0037386040
-
Use of the GlucoWatch biographer in children with Type 1 diabetes
-
Chase H.P., Roberts M.D., Wightman C., Klingensmith G., Garg S.K., Van Wyhe M., et al. Use of the GlucoWatch biographer in children with Type 1 diabetes. Pediatrics 111 (2003) 790-794
-
(2003)
Pediatrics
, vol.111
, pp. 790-794
-
-
Chase, H.P.1
Roberts, M.D.2
Wightman, C.3
Klingensmith, G.4
Garg, S.K.5
Van Wyhe, M.6
-
66
-
-
3042637599
-
The effect of preapplication of corticosteroids on skin irritation and performance of the GlucoWatch G2 Biographer
-
Tamada J.A., Davis T.L., Leptien A.D., Lee J., Wang B., Lopatin M., et al. The effect of preapplication of corticosteroids on skin irritation and performance of the GlucoWatch G2 Biographer. Diabetes Technol. Ther. 6 (2004) 357-367
-
(2004)
Diabetes Technol. Ther.
, vol.6
, pp. 357-367
-
-
Tamada, J.A.1
Davis, T.L.2
Leptien, A.D.3
Lee, J.4
Wang, B.5
Lopatin, M.6
-
67
-
-
23044434520
-
Youth and parent satisfaction with clinical use of the GlucoWatch G2 Biographer in the management of pediatric Type 1 diabetes
-
The Diabetes Research in Children Network (DirecNet) Study Group
-
The Diabetes Research in Children Network (DirecNet) Study Group. Youth and parent satisfaction with clinical use of the GlucoWatch G2 Biographer in the management of pediatric Type 1 diabetes. Diabetes Care 28 (2005) 1929-1935
-
(2005)
Diabetes Care
, vol.28
, pp. 1929-1935
-
-
-
68
-
-
33646692450
-
Psychological aspects of continuous glucose monitoring in pediatric Type 1 diabetes
-
The Diabetes Research in Children Network (DirecNet) Study Group
-
The Diabetes Research in Children Network (DirecNet) Study Group. Psychological aspects of continuous glucose monitoring in pediatric Type 1 diabetes. Pediatr. Diab. 7 (2006) 32-38
-
(2006)
Pediatr. Diab.
, vol.7
, pp. 32-38
-
-
-
69
-
-
18144373420
-
A randomized multicenter trial comparing the GlucoWatch Biographer with standard glucose monitoring in children with Type 1 diabetes
-
Chase H.P., Beck R., Tamborlane W., Buckingham B., Mauras N., Tsalikian E., et al. A randomized multicenter trial comparing the GlucoWatch Biographer with standard glucose monitoring in children with Type 1 diabetes. Diabetes Care 28 (2005) 1101-1106
-
(2005)
Diabetes Care
, vol.28
, pp. 1101-1106
-
-
Chase, H.P.1
Beck, R.2
Tamborlane, W.3
Buckingham, B.4
Mauras, N.5
Tsalikian, E.6
-
70
-
-
0023205574
-
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
-
Clarke W.L., Cox D., Gonder-Frederick L.A., Carter W., and Pohl S.L. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 10 (1987) 622-628
-
(1987)
Diabetes Care
, vol.10
, pp. 622-628
-
-
Clarke, W.L.1
Cox, D.2
Gonder-Frederick, L.A.3
Carter, W.4
Pohl, S.L.5
-
71
-
-
4344582893
-
PENDRA: the once and future noninvasive continuous glucose monitoring device?
-
Weinzimer S.A. PENDRA: the once and future noninvasive continuous glucose monitoring device?. Diabetes Technol. Ther. 6 (2004) 442-444
-
(2004)
Diabetes Technol. Ther.
, vol.6
, pp. 442-444
-
-
Weinzimer, S.A.1
-
72
-
-
4344615386
-
Impact of posture and fixation technique on impedance spectroscopy used for continuous and noninvasive glucose monitoring
-
Pfutzner A., Caduff A., Larbig M., Schrepfer T., and Forst T. Impact of posture and fixation technique on impedance spectroscopy used for continuous and noninvasive glucose monitoring. Diabetes Technol. Ther. 6 (2004) 435-441
-
(2004)
Diabetes Technol. Ther.
, vol.6
, pp. 435-441
-
-
Pfutzner, A.1
Caduff, A.2
Larbig, M.3
Schrepfer, T.4
Forst, T.5
-
74
-
-
33750349120
-
-
A. Caduff, F. Dewarrat, M. Talary, G. Stalder, L. Heinemann, Y. Feldman, Non-invasive glucose monitoring in patients with diabetes: a novel system based on impedance spectroscopy, Biosens. Bioelectron., 2006 (Epub ahead of print: doi:10.1016/j.bios.2006.01.031 (March 6, 2006)).
-
-
-
-
75
-
-
0033086369
-
Fluorescein kinetics in interstitial fluid harvested from diabetic skin during fluorescein angiography: implications for glucose monitoring
-
Smith A., Yang D., Delcher H., Eppstein J., Williams D., and Wilkes S. Fluorescein kinetics in interstitial fluid harvested from diabetic skin during fluorescein angiography: implications for glucose monitoring. Diabetes Technol. Ther. 1 (1999) 21-27
-
(1999)
Diabetes Technol. Ther.
, vol.1
, pp. 21-27
-
-
Smith, A.1
Yang, D.2
Delcher, H.3
Eppstein, J.4
Williams, D.5
Wilkes, S.6
-
76
-
-
1242343833
-
Clinical evaluation of a continuous minimally invasive glucose flux sensor placed over ultrasonically permeated skin
-
Chuang H., Taylor E., and Davison T.W. Clinical evaluation of a continuous minimally invasive glucose flux sensor placed over ultrasonically permeated skin. Diabetes Technol. Ther. 6 (2004) 21-30
-
(2004)
Diabetes Technol. Ther.
, vol.6
, pp. 21-30
-
-
Chuang, H.1
Taylor, E.2
Davison, T.W.3
|