메뉴 건너뛰기




Volumn 1, Issue 1, 2013, Pages 11-16

Technical and methodological aspects of PET/MR

Author keywords

MR compatible PET; PET MR systems; Quantification

Indexed keywords

ALGORITHM; ANALYTICAL EQUIPMENT; ATTENUATION; CRYSTAL; DETECTOR; HUMAN; MAGNET; MAGNETIC FIELD; NUCLEAR MAGNETIC RESONANCE; NUCLEAR MAGNETIC RESONANCE SCANNER; PET SCANNER; PHOTON; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; RADIOFREQUENCY; REVIEW; SCINTILLATOR CRYSTAL; SIGNAL DETECTION; SIGNAL PROCESSING;

EID: 84885474275     PISSN: 22815872     EISSN: 22817565     Source Type: Journal    
DOI: 10.1007/s40336-013-0011-5     Document Type: Review
Times cited : (6)

References (46)
  • 1
    • 0028606312 scopus 로고
    • Use of a magnetic field to increase the spatial resolution of positron emission tomography
    • Hammer BE, Christensen NL, Heil BG (1994) Use of a magnetic field to increase the spatial resolution of positron emission tomography. Med Phys 21: 1917-1920.
    • (1994) Med Phys , vol.21 , pp. 1917-1920
    • Hammer, B.E.1    Christensen, N.L.2    Heil, B.G.3
  • 2
    • 84867582847 scopus 로고    scopus 로고
    • Simulation study of tissue-specific positron range correction for the new Biograph mMR whole-body PET/MR system
    • Kraus R, Delso G, Ziegler SI (2012) Simulation study of tissue-specific positron range correction for the new Biograph mMR whole-body PET/MR system. IEEE Trans Nucl Sci 59: 1900-1909.
    • (2012) IEEE Trans Nucl Sci , vol.59 , pp. 1900-1909
    • Kraus, R.1    Delso, G.2    Ziegler, S.I.3
  • 3
    • 0000347467 scopus 로고    scopus 로고
    • Development of a PET detector system compatible with MRI/NMR systems
    • Shao Y, Cherry SR, Farahani K et al (1997) Development of a PET detector system compatible with MRI/NMR systems. IEEE Trans Nucl Sci 44: 1167-1171.
    • (1997) IEEE Trans Nucl Sci , vol.44 , pp. 1167-1171
    • Shao, Y.1    Cherry, S.R.2    Farahani, K.3
  • 5
    • 0032765446 scopus 로고    scopus 로고
    • A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner
    • Slates RB, Farahani K, Shao Y et al (1999) A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner. Phys Med Biol 44: 2015-2027.
    • (1999) Phys Med Biol , vol.44 , pp. 2015-2027
    • Slates, R.B.1    Farahani, K.2    Shao, Y.3
  • 7
    • 0030169128 scopus 로고    scopus 로고
    • Initial results from the Sherbrooke avalanche photodiode positron tomograph
    • Lecomte R, Cadorette J, Rodrigue S et al (1996) Initial results from the Sherbrooke avalanche photodiode positron tomograph. IEEE Trans Nucl Sci 43: 1952-1957.
    • (1996) IEEE Trans Nucl Sci , vol.43 , pp. 1952-1957
    • Lecomte, R.1    Cadorette, J.2    Rodrigue, S.3
  • 8
    • 0035117806 scopus 로고    scopus 로고
    • A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals
    • Ziegler SI, Pichler BJ, Boening G et al (2001) A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals. Eur J Nucl Med 28: 136-143.
    • (2001) Eur J Nucl Med , vol.28 , pp. 136-143
    • Ziegler, S.I.1    Pichler, B.J.2    Boening, G.3
  • 9
    • 4644367934 scopus 로고    scopus 로고
    • Lutetium oxyorthosilicate block detector readout by avalanche photodiode arrays for high resolution animal PET
    • Pichler BJ, Swann BK, Rochelle J et al (2004) Lutetium oxyorthosilicate block detector readout by avalanche photodiode arrays for high resolution animal PET. Phys Med Biol 49: 4305-4319.
    • (2004) Phys Med Biol , vol.49 , pp. 4305-4319
    • Pichler, B.J.1    Swann, B.K.2    Rochelle, J.3
  • 10
    • 0038182873 scopus 로고    scopus 로고
    • Silicon photomultiplier and its possible applications
    • Buzhan P, Dolgoshein B, Filatov L et al (2003) Silicon photomultiplier and its possible applications. Nucl Instr Meth A 504: 48-52.
    • (2003) Nucl Instr Meth A , vol.504 , pp. 48-52
    • Buzhan, P.1    Dolgoshein, B.2    Filatov, L.3
  • 12
    • 84859416678 scopus 로고    scopus 로고
    • Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner
    • Yoon HS, Ko GB, Kwon SI et al (2012) Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner. J Nucl Med 53: 608-614.
    • (2012) J Nucl Med , vol.53 , pp. 608-614
    • Yoon, H.S.1    Ko, G.B.2    Kwon, S.I.3
  • 15
    • 79955416013 scopus 로고    scopus 로고
    • Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system
    • Zaidi H, Ojha N, Morich M et al (2011) Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system. Phys Med Biol 56: 3091-3106.
    • (2011) Phys Med Biol , vol.56 , pp. 3091-3106
    • Zaidi, H.1    Ojha, N.2    Morich, M.3
  • 16
    • 33846873900 scopus 로고    scopus 로고
    • Simultaneous MRI and PET imaging of a rat brain
    • Raylman RR, Majewski S, Lemieux SK et al (2006) Simultaneous MRI and PET imaging of a rat brain. Phys Med Biol 51: 6371-6379.
    • (2006) Phys Med Biol , vol.51 , pp. 6371-6379
    • Raylman, R.R.1    Majewski, S.2    Lemieux, S.K.3
  • 17
    • 34247199659 scopus 로고    scopus 로고
    • Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner
    • Catana C, Wu Y, Judenhofer MS et al (2006) Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner. J Nucl Med 47: 1968-1976.
    • (2006) J Nucl Med , vol.47 , pp. 1968-1976
    • Catana, C.1    Wu, Y.2    Judenhofer, M.S.3
  • 18
    • 41849093686 scopus 로고    scopus 로고
    • Simultaneous PET-MRI: a new approach for functional and morphological imaging
    • Judenhofer MS, Wehrl HF, Newport DF et al (2008) Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat Med 14: 459-465.
    • (2008) Nat Med , vol.14 , pp. 459-465
    • Judenhofer, M.S.1    Wehrl, H.F.2    Newport, D.F.3
  • 19
    • 79956152577 scopus 로고    scopus 로고
    • High resolution BrainPET combined with simultaneous MRI
    • Herzog H, Langen KJ, Weirich C et al (2011) High resolution BrainPET combined with simultaneous MRI. Nuklearmedizin 50: 74-82.
    • (2011) Nuklearmedizin , vol.50 , pp. 74-82
    • Herzog, H.1    Langen, K.J.2    Weirich, C.3
  • 22
    • 83755161889 scopus 로고    scopus 로고
    • Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner
    • Delso G, Furst S, Jakoby B et al (2011) Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med 52: 1914-1922.
    • (2011) J Nucl Med , vol.52 , pp. 1914-1922
    • Delso, G.1    Furst, S.2    Jakoby, B.3
  • 23
    • 69549121840 scopus 로고    scopus 로고
    • Monte Carlo simulations of the count rate performance of a clinical whole-body MR/PET scanner
    • Delso G, Martinez MJ, Torres I et al (2009) Monte Carlo simulations of the count rate performance of a clinical whole-body MR/PET scanner. Med Phys 36: 4126-4135.
    • (2009) Med Phys , vol.36 , pp. 4126-4135
    • Delso, G.1    Martinez, M.J.2    Torres, I.3
  • 24
    • 77952302436 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences
    • Keereman V, Fierens Y, Broux T et al (2010) MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences. J Nucl Med 51: 812-818.
    • (2010) J Nucl Med , vol.51 , pp. 812-818
    • Keereman, V.1    Fierens, Y.2    Broux, T.3
  • 25
    • 84860811781 scopus 로고    scopus 로고
    • MRI-based attenuation correction for hybrid PET/MRI systems: a 4-class tissue segmentation technique using a combined ultrashort-echo-time/Dixon MRI sequence
    • Berker Y, Franke J, Salomon A et al (2012) MRI-based attenuation correction for hybrid PET/MRI systems: a 4-class tissue segmentation technique using a combined ultrashort-echo-time/Dixon MRI sequence. J Nucl Med 53: 796-804.
    • (2012) J Nucl Med , vol.53 , pp. 796-804
    • Berker, Y.1    Franke, J.2    Salomon, A.3
  • 26
    • 77957038794 scopus 로고    scopus 로고
    • Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype
    • Catana C, van der Kouwe A, Benner T et al (2010) Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med 51: 1431-1438.
    • (2010) J Nucl Med , vol.51 , pp. 1431-1438
    • Catana, C.1    van der Kouwe, A.2    Benner, T.3
  • 27
    • 63849338624 scopus 로고    scopus 로고
    • Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data
    • Martinez-Moller A, Souvatzoglou M, Delso G et al (2009) Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J Nucl Med 50: 520-526.
    • (2009) J Nucl Med , vol.50 , pp. 520-526
    • Martinez-Moller, A.1    Souvatzoglou, M.2    Delso, G.3
  • 28
    • 76949090527 scopus 로고    scopus 로고
    • Three-region MRI-based whole-body attenuation correction for automated PET reconstruction
    • Steinberg J, Jia G, Sammet S et al (2010) Three-region MRI-based whole-body attenuation correction for automated PET reconstruction. Nucl Med Biol 37: 227-235.
    • (2010) Nucl Med Biol , vol.37 , pp. 227-235
    • Steinberg, J.1    Jia, G.2    Sammet, S.3
  • 29
    • 79551523276 scopus 로고    scopus 로고
    • Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
    • Schulz V, Torres-Espallardo I, Renisch S et al (2011) Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data. Eur J Nucl Med Mol Imaging 38: 138-152.
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , pp. 138-152
    • Schulz, V.1    Torres-Espallardo, I.2    Renisch, S.3
  • 30
    • 80855128883 scopus 로고    scopus 로고
    • The effect of errors in segmented attenuation maps on PET quantification
    • Keereman V, Holen RV, Mollet P, Vandenberghe S (2011) The effect of errors in segmented attenuation maps on PET quantification. Med Phys 38: 6010-6019.
    • (2011) Med Phys , vol.38 , pp. 6010-6019
    • Keereman, V.1    Holen, R.V.2    Mollet, P.3    Vandenberghe, S.4
  • 31
    • 14244251257 scopus 로고    scopus 로고
    • Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging
    • Montandon ML, Zaidi H (2005) Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging. Neuroimage 25: 278-286.
    • (2005) Neuroimage , vol.25 , pp. 278-286
    • Montandon, M.L.1    Zaidi, H.2
  • 32
    • 57349155316 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration
    • Hofmann M, Steinke F, Scheel V et al (2008) MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J Nucl Med 49: 1875-1883.
    • (2008) J Nucl Med , vol.49 , pp. 1875-1883
    • Hofmann, M.1    Steinke, F.2    Scheel, V.3
  • 33
    • 79960336732 scopus 로고    scopus 로고
    • Attenuation correction methods suitable for brain imaging with a PET/MRI scanner: a comparison of tissue atlas and template attenuation map approaches
    • Malone IB, Ansorge RE, Williams GB et al (2011) Attenuation correction methods suitable for brain imaging with a PET/MRI scanner: a comparison of tissue atlas and template attenuation map approaches. J Nucl Med 52: 1142-1149.
    • (2011) J Nucl Med , vol.52 , pp. 1142-1149
    • Malone, I.B.1    Ansorge, R.E.2    Williams, G.B.3
  • 34
    • 80052644918 scopus 로고    scopus 로고
    • MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods
    • Hofmann M, Bezrukov I, Mantlik F et al (2011) MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med 52: 1392-1399.
    • (2011) J Nucl Med , vol.52 , pp. 1392-1399
    • Hofmann, M.1    Bezrukov, I.2    Mantlik, F.3
  • 36
    • 84856853168 scopus 로고    scopus 로고
    • Time-of-flight PET data determine the attenuation sinogram up to a constant
    • Defrise M, Rezaei A, Nuyts J (2012) Time-of-flight PET data determine the attenuation sinogram up to a constant. Phys Med Biol 57: 885-899.
    • (2012) Phys Med Biol , vol.57 , pp. 885-899
    • Defrise, M.1    Rezaei, A.2    Nuyts, J.3
  • 39
    • 84870252314 scopus 로고    scopus 로고
    • Attenuation correction for PET/MR: problems, novel approaches and practical solutions
    • Martinez-Moller A, Nekolla SG (2012) Attenuation correction for PET/MR: problems, novel approaches and practical solutions. Z Med Phys 22: 299-310.
    • (2012) Z Med Phys , vol.22 , pp. 299-310
    • Martinez-Moller, A.1    Nekolla, S.G.2
  • 40
    • 78049448620 scopus 로고    scopus 로고
    • Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
    • Delso G, Martinez-Moller A, Bundschuh RA et al (2010) Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner. Phys Med Biol 55: 4361-4374.
    • (2010) Phys Med Biol , vol.55 , pp. 4361-4374
    • Delso, G.1    Martinez-Moller, A.2    Bundschuh, R.A.3
  • 41
    • 79959543762 scopus 로고    scopus 로고
    • The effect of MR surface coils on PET quantification in whole-body PET/MR: results from a pseudo-PET/MR phantom study
    • Tellmann L, Quick HH, Bockisch A, Herzog H, Beyer T (2011) The effect of MR surface coils on PET quantification in whole-body PET/MR: results from a pseudo-PET/MR phantom study. Med Phys 38: 2795-2805.
    • (2011) Med Phys , vol.38 , pp. 2795-2805
    • Tellmann, L.1    Quick, H.H.2    Bockisch, A.3    Herzog, H.4    Beyer, T.5
  • 42
    • 84864220423 scopus 로고    scopus 로고
    • Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils
    • Paulus DH, Braun H, Aklan B, Quick HH (2012) Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils. Med Phys 39: 4306-4315.
    • (2012) Med Phys , vol.39 , pp. 4306-4315
    • Paulus, D.H.1    Braun, H.2    Aklan, B.3    Quick, H.H.4
  • 44
    • 84873286392 scopus 로고    scopus 로고
    • Completion of a truncated attenuation image from the attenuated PET emission data
    • Nuyts J, Bal G, Kehren F et al (2012) Completion of a truncated attenuation image from the attenuated PET emission data. IEEE Trans Med Imaging 32(2): 237-246.
    • (2012) IEEE Trans Med Imaging , vol.32 , Issue.2 , pp. 237-246
    • Nuyts, J.1    Bal, G.2    Kehren, F.3
  • 45
    • 84880664944 scopus 로고    scopus 로고
    • MR-based field-of-view extension in MR/PET: B(0) homogenization using gradient enhancement (HUGE)
    • doi:10.1002/mrm.24555
    • Blumhagen JO, Ladebeck R, Fenchel M, Scheffler K (2012) MR-based field-of-view extension in MR/PET: B(0) homogenization using gradient enhancement (HUGE). Magn Reson Med. doi: 10. 1002/mrm. 24555.
    • (2012) Magn Reson Med
    • Blumhagen, J.O.1    Ladebeck, R.2    Fenchel, M.3    Scheffler, K.4
  • 46
    • 84870036887 scopus 로고    scopus 로고
    • Magnetic resonance-based motion correction for positron emission tomography imaging
    • Ouyang J, Li Q, El Fakhri G (2013) Magnetic resonance-based motion correction for positron emission tomography imaging. Semin Nucl Med 43: 60-67.
    • (2013) Semin Nucl Med , vol.43 , pp. 60-67
    • Ouyang, J.1    Li, Q.2    El Fakhri, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.