메뉴 건너뛰기




Volumn 39, Issue 7, 2012, Pages 4306-4315

Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils

Author keywords

attenuation correction (AC); hybrid imaging; radiofrequency (RF) surface coil; simultaneous whole body PET MR; UTE sequence

Indexed keywords

DATA ACQUISITION; IMAGE REGISTRATION; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING; PHANTOMS; POSITRON EMISSION TOMOGRAPHY; SIGNAL RECEIVERS;

EID: 84864220423     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4729716     Document Type: Article
Times cited : (102)

References (29)
  • 1
    • 80053611395 scopus 로고    scopus 로고
    • An outlook on future design of hybrid PET/MRI systems
    • 10.1118/1.3633909
    • H. Zaidi and A. D. Guerra, An outlook on future design of hybrid PET/MRI systems., Med. Phys. 38 (10), 5667-5689 (2011). 10.1118/1.3633909
    • (2011) Med. Phys. , vol.38 , Issue.10 , pp. 5667-5689
    • Zaidi, H.1    Guerra, A.D.2
  • 5
    • 34247199659 scopus 로고    scopus 로고
    • Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner
    • C. Catana, Y. Wu, M. S. Judenhofer, J. Qi, B. J. Pichler, and S. R. Cherry, Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner., J. Nucl. Med. 47 (12), 1968-1976 (2006).
    • (2006) J. Nucl. Med. , vol.47 , Issue.12 , pp. 1968-1976
    • Catana, C.1    Wu, Y.2    Judenhofer, M.S.3    Qi, J.4    Pichler, B.J.5    Cherry, S.R.6
  • 7
    • 71849117812 scopus 로고    scopus 로고
    • The current state, challenges and perspectives of MR-PET
    • 10.1016/j.neuroimage.2009.10.036
    • H. Herzog, U. Pietrzyk, N. J. Shah, and K. Ziemons, The current state, challenges and perspectives of MR-PET., Neuroimage 49 (3), 2072-2082 (2010). 10.1016/j.neuroimage.2009.10.036
    • (2010) Neuroimage , vol.49 , Issue.3 , pp. 2072-2082
    • Herzog, H.1    Pietrzyk, U.2    Shah, N.J.3    Ziemons, K.4
  • 8
    • 84859416678 scopus 로고    scopus 로고
    • Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner
    • 10.2967/jnumed.111.097501
    • H. S. Yoon, G. B. Ko, S. I. Kwon, C. M. Lee, M. Ito, I. Chan Song, D. S. Lee, S. J. Hong, and J. S. Lee, Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner., J. Nucl. Med. 53 (4), 608-614 (2012). 10.2967/jnumed.111.097501
    • (2012) J. Nucl. Med. , vol.53 , Issue.4 , pp. 608-614
    • Yoon, H.S.1    Ko, G.B.2    Kwon, S.I.3    Lee, C.M.4    Ito, M.5    Chan Song, I.6    Lee, D.S.7    Hong, S.J.8    Lee, J.S.9
  • 9
    • 84864254117 scopus 로고    scopus 로고
    • Whole-body MR/PET hybrid imaging: Technical considerations, clinical workflow, and initial results
    • H. H. Quick, R. Ladebeck, and J. C. Georgi, Whole-body MR/PET hybrid imaging: Technical considerations, clinical workflow, and initial results., MAGNETOM Flash 1, 88-100 (2011).
    • (2011) MAGNETOM Flash , vol.1 , pp. 88-100
    • Quick, H.H.1    Ladebeck, R.2    Georgi, J.C.3
  • 10
    • 84858708392 scopus 로고    scopus 로고
    • Whole-body MR/PET: Applications in abdominal imaging
    • 10.1007/s00261-011-9809-7
    • N. F. Schwenzer, H. Schmidt, and C. D. Claussen, Whole-body MR/PET: applications in abdominal imaging., Abdom. Imaging 37, 20-28 (2012). 10.1007/s00261-011-9809-7
    • (2012) Abdom. Imaging , vol.37 , pp. 20-28
    • Schwenzer, N.F.1    Schmidt, H.2    Claussen, C.D.3
  • 12
    • 63849338624 scopus 로고    scopus 로고
    • Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: Evaluation with PET/CT data
    • 10.2967/jnumed.108.054726
    • A. Martinez-Möller, M. Souvatzoglou, G. Delso, R. A. Bundschuh, C. Chefdhotel, S. I. Ziegler, N. Navab, M. Schwaiger, and S. G. Nekolla, Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: Evaluation with PET/CT data., J. Nucl. Med. 50 (4), 520-526 (2009). 10.2967/jnumed.108.054726
    • (2009) J. Nucl. Med. , vol.50 , Issue.4 , pp. 520-526
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Delso, G.3    Bundschuh, R.A.4    Chefdhotel, C.5    Ziegler, S.I.6    Navab, N.7    Schwaiger, M.8    Nekolla, S.G.9
  • 13
    • 76949090527 scopus 로고    scopus 로고
    • Three-region MRI-based whole-body attenuation correction for automated PET reconstruction
    • 10.1016/j.nucmedbio.2009.11.002
    • J. Steinberg, G. Jia, S. Sammet, J. Zhang, N. Hall, and M. V. Knopp, Three-region MRI-based whole-body attenuation correction for automated PET reconstruction., Nucl. Med. Biol. 37 (2), 227-235 (2010). 10.1016/j.nucmedbio. 2009.11.002
    • (2010) Nucl. Med. Biol. , vol.37 , Issue.2 , pp. 227-235
    • Steinberg, J.1    Jia, G.2    Sammet, S.3    Zhang, J.4    Hall, N.5    Knopp, M.V.6
  • 15
    • 77957038794 scopus 로고    scopus 로고
    • Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype
    • 10.2967/jnumed.109.069112
    • C. Catana, A. v. d. Kouwe, T. Benner, C. J. Michel, M. Hamm, M. Fenchel, B. Fischl, B. Rosen, M. Schmand, and A. G. Sorensen, Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype., J. Nucl. Med. 51 (9), 1431-1438 (2010). 10.2967/jnumed.109. 069112
    • (2010) J. Nucl. Med. , vol.51 , Issue.9 , pp. 1431-1438
    • Catana, C.1    Kouwe, A.V.D.2    Benner, T.3    Michel, C.J.4    Hamm, M.5    Fenchel, M.6    Fischl, B.7    Rosen, B.8    Schmand, M.9    Sorensen, A.G.10
  • 16
    • 80855128883 scopus 로고    scopus 로고
    • The effect of errors in segmented attenuation maps on PET quantification
    • 10.1118/1.3651640
    • V. Keereman, R. van Holen, P. Mollet, and S. Vandenberghe, The effect of errors in segmented attenuation maps on PET quantification., Med. Phys. 38 (11), 6010-6019 (2011). 10.1118/1.3651640
    • (2011) Med. Phys. , vol.38 , Issue.11 , pp. 6010-6019
    • Keereman, V.1    Van Holen, R.2    Mollet, P.3    Vandenberghe, S.4
  • 17
    • 84860811781 scopus 로고    scopus 로고
    • MRI-based attenuation correction for hybrid PET/MRI systems: A 4-class tissue segmentation technique using a combined ultrashort-echo-time/Dixon MRI sequence
    • 10.2967/jnumed.111.092577
    • Y. Berker, J. Franke, A. Salomon, M. Palmowski, H. C. W. Donker, Y. Temur, Y. Mottaghy, C. Kuhl, D. Izquierdo-Garcia, Z. A. Fayad, F. Kiessling, and V. Schulz, MRI-based attenuation correction for hybrid PET/MRI systems: A 4-class tissue segmentation technique using a combined ultrashort-echo-time/ Dixon MRI sequence., J. Nucl. Med. 53 (5), 796-804 (2012). 10.2967/jnumed.111. 092577
    • (2012) J. Nucl. Med. , vol.53 , Issue.5 , pp. 796-804
    • Berker, Y.1    Franke, J.2    Salomon, A.3    Palmowski, M.4    Donker, H.C.W.5    Temur, Y.6    Mottaghy, Y.7    Kuhl, C.8    Izquierdo-Garcia, D.9    Fayad, Z.A.10    Kiessling, F.11    Schulz, V.12
  • 18
    • 77952302436 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences
    • 10.2967/jnumed.109.065425
    • V. Keereman, Y. Fierens, T. Broux, Y. D. Deene, M. Lonneux, and S. Vandenberghe, MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences., J. Nucl. Med. 51 (5), 812-818 (2010). 10.2967/jnumed.109. 065425
    • (2010) J. Nucl. Med. , vol.51 , Issue.5 , pp. 812-818
    • Keereman, V.1    Fierens, Y.2    Broux, T.3    Deene, Y.D.4    Lonneux, M.5    Vandenberghe, S.6
  • 19
    • 14244251257 scopus 로고    scopus 로고
    • Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging
    • 10.1016/j.neuroimage.2004.11.021
    • M. L. Montandon and H. Zaidi, Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging., Neuroimage 25 (1), 278-286 (2005). 10.1016/j.neuroimage.2004.11.021
    • (2005) Neuroimage , vol.25 , Issue.1 , pp. 278-286
    • Montandon, M.L.1    Zaidi, H.2
  • 20
    • 57349155316 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI: A novel approach combining pattern recognition and atlas registration
    • 10.2967/jnumed.107.049353
    • M. Hofmann, F. Steinke, V. Scheel, G. Charpiat, J. Farquhar, P. Aschoff, M. Brady, B. Schölkopf, and B. J. Pichler, MRI-based attenuation correction for PET/MRI: A novel approach combining pattern recognition and atlas registration., J. Nucl. Med. 49 (11), 1875-1883 (2008). 10.2967/jnumed.107. 049353
    • (2008) J. Nucl. Med. , vol.49 , Issue.11 , pp. 1875-1883
    • Hofmann, M.1    Steinke, F.2    Scheel, V.3    Charpiat, G.4    Farquhar, J.5    Aschoff, P.6    Brady, M.7    Schölkopf, B.8    Pichler, B.J.9
  • 23
    • 78049448620 scopus 로고    scopus 로고
    • Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
    • 10.1088/0031-9155/55/15/011
    • G. Delso, A. Martinez-Möller, R. A. Bundschuh, R. Ladebeck, Y. Candidus, D. Faul, and S. I. Ziegler, Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner., Phys. Med. Biol. 55 (15), 4361-4374 (2010). 10.1088/0031-9155/55/15/011
    • (2010) Phys. Med. Biol. , vol.55 , Issue.15 , pp. 4361-4374
    • Delso, G.1    Martinez-Möller, A.2    Bundschuh, R.A.3    Ladebeck, R.4    Candidus, Y.5    Faul, D.6    Ziegler, S.I.7
  • 24
    • 79959543762 scopus 로고    scopus 로고
    • The effect of MR surface coils on PET quantification in whole-body PET/MR: Results from a pseudo-PET/MR phantom study
    • 10.1118/1.3582699
    • L. Tellmann, H. H. Quick, A. Bockisch, H. Herzog, and T. Beyer, The effect of MR surface coils on PET quantification in whole-body PET/MR: Results from a pseudo-PET/MR phantom study., Med. Phys. 38 (5), 2795-2805 (2011). 10.1118/1.3582699
    • (2011) Med. Phys. , vol.38 , Issue.5 , pp. 2795-2805
    • Tellmann, L.1    Quick, H.H.2    Bockisch, A.3    Herzog, H.4    Beyer, T.5
  • 25
    • 79958775484 scopus 로고    scopus 로고
    • Effects of MR surface coils on PET quantification
    • 10.1118/1.3583697
    • L. R. MacDonald, S. Kohlmyer, C. Liu, T. K. Lewellen, and P. E. Kinahan, Effects of MR surface coils on PET quantification., Med. Phys. 38 (6), 2948-2956 (2011). 10.1118/1.3583697
    • (2011) Med. Phys. , vol.38 , Issue.6 , pp. 2948-2956
    • MacDonald, L.R.1    Kohlmyer, S.2    Liu, C.3    Lewellen, T.K.4    Kinahan, P.E.5
  • 26
    • 60549086399 scopus 로고    scopus 로고
    • Towards quantitative PET/MRI: A review of MR-based attenuation correction techniques
    • 10.1007/s00259-008-1007-7
    • M. Hofmann, B. J. Pichler, B. Schölkopf, and T. Beyer, Towards quantitative PET/MRI: A review of MR-based attenuation correction techniques., Eur. J. Nucl. Med. Mol. Imaging 36 (S1), 93-104 (2009). 10.1007/s00259-008-1007- 7
    • (2009) Eur. J. Nucl. Med. Mol. Imaging , vol.36 , Issue.S1 , pp. 93-104
    • Hofmann, M.1    Pichler, B.J.2    Schölkopf, B.3    Beyer, T.4
  • 27
    • 84856212651 scopus 로고    scopus 로고
    • Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA)
    • 10.1002/mrm.23017
    • D. M. Grodzki, P. M. Jakob, and B. Heismann, Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA)., Magn. Reson. Med. 67 (2), 510-518 (2012). 10.1002/mrm.23017
    • (2012) Magn. Reson. Med. , vol.67 , Issue.2 , pp. 510-518
    • Grodzki, D.M.1    Jakob, P.M.2    Heismann, B.3
  • 28
    • 33645510085 scopus 로고    scopus 로고
    • Method for transforming CT images for attenuation correction in PET/CT imaging
    • 10.1118/1.2174132
    • J. P. J. Carney, D. W. Townsend, V. Rappoport, and B. Bendriem, Method for transforming CT images for attenuation correction in PET/CT imaging., Med. Phys. 33 (4), 976-983 (2006). 10.1118/1.2174132
    • (2006) Med. Phys. , vol.33 , Issue.4 , pp. 976-983
    • Carney, J.P.J.1    Townsend, D.W.2    Rappoport, V.3    Bendriem, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.