메뉴 건너뛰기




Volumn 22, Issue 4, 2012, Pages 299-310

Attenuation correction for PET/MR: Problems, novel approaches and practical solutions

Author keywords

Attenuation correction; PET MR

Indexed keywords

TRACER;

EID: 84870252314     PISSN: 09393889     EISSN: 18764436     Source Type: Journal    
DOI: 10.1016/j.zemedi.2012.08.003     Document Type: Article
Times cited : (57)

References (76)
  • 1
    • 60549093826 scopus 로고    scopus 로고
    • The potential of PET/MR for brain imaging
    • Heiss W.D. The potential of PET/MR for brain imaging. Eur J Nucl Med Mol Imaging 2009, 36(1):105-112.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.1 , pp. 105-112
    • Heiss, W.D.1
  • 2
    • 60549089555 scopus 로고    scopus 로고
    • Combined PET/MRI: a new dimension in whole-body oncology imaging?
    • Antoch G., Bockisch A. Combined PET/MRI: a new dimension in whole-body oncology imaging?. Eur J Nucl Med Mol Imaging 2009, 36(1):113-120.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.1 , pp. 113-120
    • Antoch, G.1    Bockisch, A.2
  • 3
    • 60649120728 scopus 로고    scopus 로고
    • PET and MRI in cardiac imaging: from validation studies to integrated applications
    • Nekolla S.G., Martinez-Möller A., Saraste A. PET and MRI in cardiac imaging: from validation studies to integrated applications. Eur J Nucl Med Mol Imaging 2009, 36(1):121-130.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.1 , pp. 121-130
    • Nekolla, S.G.1    Martinez-Möller, A.2    Saraste, A.3
  • 4
    • 79955416013 scopus 로고    scopus 로고
    • Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system
    • Zaidi H., Ojha N., Morich M., Griesmer J., Hu Z., Maniawski P., et al. Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system. Phys Med Biol 2011, 56(10):3091-3106.
    • (2011) Phys Med Biol , vol.56 , Issue.10 , pp. 3091-3106
    • Zaidi, H.1    Ojha, N.2    Morich, M.3    Griesmer, J.4    Hu, Z.5    Maniawski, P.6
  • 5
    • 83755161889 scopus 로고    scopus 로고
    • Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner
    • Delso G., Fürst S., Jakoby B., Ladebeck R., Ganter C., Nekolla S.G., et al. Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med 2011, 52:1914-1922.
    • (2011) J Nucl Med , vol.52 , pp. 1914-1922
    • Delso, G.1    Fürst, S.2    Jakoby, B.3    Ladebeck, R.4    Ganter, C.5    Nekolla, S.G.6
  • 6
    • 0037315301 scopus 로고    scopus 로고
    • Determination of the Attenuation Map in Emission Tomography
    • Zaidi H., Hasegawa B. Determination of the Attenuation Map in Emission Tomography. J Nucl Med 2003, 44:291-315.
    • (2003) J Nucl Med , vol.44 , pp. 291-315
    • Zaidi, H.1    Hasegawa, B.2
  • 7
    • 60549086399 scopus 로고    scopus 로고
    • Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
    • Hofmann M., Pichler B., Schölkopf B., Beyer T. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques. Eur J Nucl Med Mol Imaging 2009, 36(Suppl. 1):93-104.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1 , pp. 93-104
    • Hofmann, M.1    Pichler, B.2    Schölkopf, B.3    Beyer, T.4
  • 8
    • 0031791001 scopus 로고    scopus 로고
    • Attenuation correction for a combined 3D PET/CT scanner
    • Kinahan P.E., Townsend D.W., Beyer T., Sashin D. Attenuation correction for a combined 3D PET/CT scanner. Med Phys 1998, 25(10):2046-2053.
    • (1998) Med Phys , vol.25 , Issue.10 , pp. 2046-2053
    • Kinahan, P.E.1    Townsend, D.W.2    Beyer, T.3    Sashin, D.4
  • 9
    • 0037655094 scopus 로고    scopus 로고
    • Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology
    • Beyer T., Antoch G., Blodgett T., Freudenberg L.F., Akhurst T., Mueller S. Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology. Eur J Nucl Med 2003, 30:588-596.
    • (2003) Eur J Nucl Med , vol.30 , pp. 588-596
    • Beyer, T.1    Antoch, G.2    Blodgett, T.3    Freudenberg, L.F.4    Akhurst, T.5    Mueller, S.6
  • 10
    • 34047230826 scopus 로고    scopus 로고
    • Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions
    • Martinez-Möller A., Souvatzoglou M., Navab N., Schwaiger M., Nekolla S.G. Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions. J Nucl Med 2007, 48:188-193.
    • (2007) J Nucl Med , vol.48 , pp. 188-193
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Navab, N.3    Schwaiger, M.4    Nekolla, S.G.5
  • 12
    • 0037950269 scopus 로고    scopus 로고
    • Effects of nonionic intravenous contrast agents at PET/CT imaging: phantom and canine studies
    • Nakamoto Y., Chin B.B., Kraitchman D.L., Lawler L.P., Marshall L.T., Wahl R.L. Effects of nonionic intravenous contrast agents at PET/CT imaging: phantom and canine studies. Radiology 2003, 227:817-824.
    • (2003) Radiology , vol.227 , pp. 817-824
    • Nakamoto, Y.1    Chin, B.B.2    Kraitchman, D.L.3    Lawler, L.P.4    Marshall, L.T.5    Wahl, R.L.6
  • 13
    • 15844389922 scopus 로고    scopus 로고
    • Application of intravenous contrast in PET/CT: does it really introduce significant attenuation correction error?
    • Yau Y.Y., Chan W.S., Tam Y.M., Vernon P., Wong S., Coel M., et al. Application of intravenous contrast in PET/CT: does it really introduce significant attenuation correction error?. J Nucl Med 2005, 46:283-291.
    • (2005) J Nucl Med , vol.46 , pp. 283-291
    • Yau, Y.Y.1    Chan, W.S.2    Tam, Y.M.3    Vernon, P.4    Wong, S.5    Coel, M.6
  • 14
    • 0018983329 scopus 로고
    • Noise identification and removal in positron imaging systems
    • King P.H. Noise identification and removal in positron imaging systems. IEEE Trans Nucl Sci 1981, 28:148-151.
    • (1981) IEEE Trans Nucl Sci , vol.28 , pp. 148-151
    • King, P.H.1
  • 15
    • 0020660172 scopus 로고
    • Correction for scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the Projections
    • Bergstrom M., Eriksson L., Bohm C., Blomqvist G., Litton J. Correction for scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the Projections. J Comp Assist Tomogr 1983, 7(1):42-50.
    • (1983) J Comp Assist Tomogr , vol.7 , Issue.1 , pp. 42-50
    • Bergstrom, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 16
    • 0029797912 scopus 로고    scopus 로고
    • Correction for scatter in 3D brain PET using a dual energy window method
    • Grootoonk S., Spinks T.J., Sashin D., Spyrou N.M., Jones T. Correction for scatter in 3D brain PET using a dual energy window method. Phys Med Biol 1996, 41:2757-2774.
    • (1996) Phys Med Biol , vol.41 , pp. 2757-2774
    • Grootoonk, S.1    Spinks, T.J.2    Sashin, D.3    Spyrou, N.M.4    Jones, T.5
  • 17
    • 0001540219 scopus 로고
    • Correction for Scatter Using a Dual Energy Window Technique with a Tomograph Operating without Septa
    • Jones T., Michel C., Bol A. Correction for Scatter Using a Dual Energy Window Technique with a Tomograph Operating without Septa. IEEE Med Imaging Conf 1991, 1569-1573.
    • (1991) IEEE Med Imaging Conf , pp. 1569-1573
    • Jones, T.1    Michel, C.2    Bol, A.3
  • 19
    • 0028194423 scopus 로고
    • A PET scatter correction using simultaneous acquisitions with low and high lower energy thresholds
    • Bendriem B., Trébossen R., Frouin V., Syrota A. A PET scatter correction using simultaneous acquisitions with low and high lower energy thresholds. IEEE Med Imaging Conf 1993, 1779-1783.
    • (1993) IEEE Med Imaging Conf , pp. 1779-1783
    • Bendriem, B.1    Trébossen, R.2    Frouin, V.3    Syrota, A.4
  • 20
    • 3242772275 scopus 로고    scopus 로고
    • Optimization of a fully 3D single scatter simulation algorithm for 3D PET
    • Accorsi R., Adam L.E., Werner M.E., Karp J.S. Optimization of a fully 3D single scatter simulation algorithm for 3D PET. Phys Med Biol 2004, 49(12):2577-2598.
    • (2004) Phys Med Biol , vol.49 , Issue.12 , pp. 2577-2598
    • Accorsi, R.1    Adam, L.E.2    Werner, M.E.3    Karp, J.S.4
  • 21
    • 2442555874 scopus 로고    scopus 로고
    • Scatter modelling and compensation in emission tomography
    • Zaidi H., Koral K.F. Scatter modelling and compensation in emission tomography. Eur J Nucl Med 2004, 31(5):761-782.
    • (2004) Eur J Nucl Med , vol.31 , Issue.5 , pp. 761-782
    • Zaidi, H.1    Koral, K.F.2
  • 22
    • 0030067225 scopus 로고    scopus 로고
    • Model-based scatter correction for fully 3D PET
    • Ollinger J.M. Model-based scatter correction for fully 3D PET. Phys Med Biol 1996, 41:153-176.
    • (1996) Phys Med Biol , vol.41 , pp. 153-176
    • Ollinger, J.M.1
  • 23
    • 0001320737 scopus 로고    scopus 로고
    • A single scatter simulation technique for scatter correction in 3D PET
    • Kluwer Academic Publishers, Dordrecht, P. Grangeat, J.L. Amans (Eds.)
    • Watson C.C., Newport D., Casey M.E. A single scatter simulation technique for scatter correction in 3D PET. Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine 1996, 255-268. Kluwer Academic Publishers, Dordrecht. P. Grangeat, J.L. Amans (Eds.).
    • (1996) Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine , pp. 255-268
    • Watson, C.C.1    Newport, D.2    Casey, M.E.3
  • 24
    • 0034244929 scopus 로고    scopus 로고
    • New, faster, image-based scatter correction for 3D PET
    • Watson C.C. New, faster, image-based scatter correction for 3D PET. IEEE Trans Nuc Sci 2000, 47(4):1587-1594.
    • (2000) IEEE Trans Nuc Sci , vol.47 , Issue.4 , pp. 1587-1594
    • Watson, C.C.1
  • 26
    • 83755168338 scopus 로고    scopus 로고
    • Effect of patient arm motion in whole-body PET/CT
    • Lodge M.A., Mhlanga J.C., Cho S.Y., Wahl R.L. Effect of patient arm motion in whole-body PET/CT. J Nucl Med 2011, 52(12):1891-1897.
    • (2011) J Nucl Med , vol.52 , Issue.12 , pp. 1891-1897
    • Lodge, M.A.1    Mhlanga, J.C.2    Cho, S.Y.3    Wahl, R.L.4
  • 28
    • 0020048935 scopus 로고
    • Determination of object contour from projections for attenuation correction in cranial positron emission tomography
    • Bergström M., Litton J., Eriksson L., Bohm C., Blomqvist G. Determination of object contour from projections for attenuation correction in cranial positron emission tomography. J Comput Assist Tomogr 1982, 6:365-372.
    • (1982) J Comput Assist Tomogr , vol.6 , pp. 365-372
    • Bergström, M.1    Litton, J.2    Eriksson, L.3    Bohm, C.4    Blomqvist, G.5
  • 29
    • 85076214625 scopus 로고
    • Segmented MR images for brain attenuation correction in PET
    • Le Goff-Rougetet R., Frouin V., Bendriem B. Segmented MR images for brain attenuation correction in PET. Proc SPIE 1994, 2167:725-736.
    • (1994) Proc SPIE , vol.2167 , pp. 725-736
    • Le Goff-Rougetet, R.1    Frouin, V.2    Bendriem, B.3
  • 30
    • 0038247944 scopus 로고    scopus 로고
    • Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography
    • Zaidi H., Montandon M.L., Slosman D.O. Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography. Med Phys 2003, 30:937-948.
    • (2003) Med Phys , vol.30 , pp. 937-948
    • Zaidi, H.1    Montandon, M.L.2    Slosman, D.O.3
  • 31
    • 63849181542 scopus 로고    scopus 로고
    • MRI based attenuation correction for brain PET images
    • Springer, Berlin Heidelberg, T.M. Buzug, D. Holz, J. Bongartz, M. Kohl-Bareis, U. Hartmann, S. Weber (Eds.)
    • Rota Kops E., Qin P., Müller-Veggian M., Herzog H. MRI based attenuation correction for brain PET images. Advances in Medical Engineering 2007, 93-97. Springer, Berlin Heidelberg. T.M. Buzug, D. Holz, J. Bongartz, M. Kohl-Bareis, U. Hartmann, S. Weber (Eds.).
    • (2007) Advances in Medical Engineering , pp. 93-97
    • Rota Kops, E.1    Qin, P.2    Müller-Veggian, M.3    Herzog, H.4
  • 32
    • 84858663070 scopus 로고    scopus 로고
    • Attenuation correction in MR-BrainPET with segmented T1-weighted MR images of the patient's head - A comparative study with CT
    • Wagenknecht G., Rota Kops E., Mantlik F., Fried E., Pilz T., Hautzel H., et al. Attenuation correction in MR-BrainPET with segmented T1-weighted MR images of the patient's head - A comparative study with CT. IEEE Nucl Sci Symp Conf Rec 2011, 2261-2266.
    • (2011) IEEE Nucl Sci Symp Conf Rec , pp. 2261-2266
    • Wagenknecht, G.1    Rota Kops, E.2    Mantlik, F.3    Fried, E.4    Pilz, T.5    Hautzel, H.6
  • 34
    • 77957038794 scopus 로고    scopus 로고
    • Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype
    • Catana C., van der Kouwe A., Benner T., Vernon P., Wong S., Coel M., et al. Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype. J Nucl Med. 2010, 51:1431-1438.
    • (2010) J Nucl Med. , vol.51 , pp. 1431-1438
    • Catana, C.1    van der Kouwe, A.2    Benner, T.3    Vernon, P.4    Wong, S.5    Coel, M.6
  • 35
    • 84860811781 scopus 로고    scopus 로고
    • MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence
    • Berker Y., Franke J., Salomon A., Palmowski M., Donker H.C., Temur Y., et al. MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence. J Nucl Med 2012, 53(5):796-804.
    • (2012) J Nucl Med , vol.53 , Issue.5 , pp. 796-804
    • Berker, Y.1    Franke, J.2    Salomon, A.3    Palmowski, M.4    Donker, H.C.5    Temur, Y.6
  • 36
    • 43749088783 scopus 로고    scopus 로고
    • An approach for MR-based attenuation correction for combined MR/PET: effects of ignoring bones (abstract)
    • Martínez-Möller A., Souvatzoglou M., Botnar R., Navab N., Ziegler S., Schwaiger M., et al. An approach for MR-based attenuation correction for combined MR/PET: effects of ignoring bones (abstract). J Nucl Med 2007, 48(Suppl. 2):156P.
    • (2007) J Nucl Med , vol.48 , Issue.SUPPL. 2
    • Martínez-Möller, A.1    Souvatzoglou, M.2    Botnar, R.3    Navab, N.4    Ziegler, S.5    Schwaiger, M.6
  • 37
    • 63849338624 scopus 로고    scopus 로고
    • Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data
    • Martinez-Möller A., Souvatzoglou M., Delso G. Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data. J Nucl Med 2009, 50:520-526.
    • (2009) J Nucl Med , vol.50 , pp. 520-526
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Delso, G.3
  • 38
    • 51449106071 scopus 로고    scopus 로고
    • Dixon Techniques for Water and Fat Imaging
    • Ma J. Dixon Techniques for Water and Fat Imaging. J Magn Reson Imaging 2008, 28:543-558.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 543-558
    • Ma, J.1
  • 39
    • 76949090527 scopus 로고    scopus 로고
    • Three-region MRI-based whole-body attenuation correction for automated PET reconstruction
    • Steinberg J., Jia G., Sammet S., Zhang J., Hall N., Knopp M.V. Three-region MRI-based whole-body attenuation correction for automated PET reconstruction. Nucl Med Biol 2010, 37:227-235.
    • (2010) Nucl Med Biol , vol.37 , pp. 227-235
    • Steinberg, J.1    Jia, G.2    Sammet, S.3    Zhang, J.4    Hall, N.5    Knopp, M.V.6
  • 41
    • 84862643672 scopus 로고    scopus 로고
    • PET/MR imaging of bone lesions - implications for PET quantification from imperfect attenuation correction
    • Samarin A., Burger C., Wollenweber S.D., Crook D.W., Burger I.A., Schmid D.T., et al. PET/MR imaging of bone lesions - implications for PET quantification from imperfect attenuation correction. Eur J Nucl Med Mol Imaging 2012, 39(7):1154-1160.
    • (2012) Eur J Nucl Med Mol Imaging , vol.39 , Issue.7 , pp. 1154-1160
    • Samarin, A.1    Burger, C.2    Wollenweber, S.D.3    Crook, D.W.4    Burger, I.A.5    Schmid, D.T.6
  • 42
    • 80855128883 scopus 로고    scopus 로고
    • The effect of errors in segmented attenuation maps on PET quantification
    • Keereman V., Van Holen R., Mollet P., Candenberghe S. The effect of errors in segmented attenuation maps on PET quantification. Med Phys 2011, 38:6010-6019.
    • (2011) Med Phys , vol.38 , pp. 6010-6019
    • Keereman, V.1    Van Holen, R.2    Mollet, P.3    Candenberghe, S.4
  • 43
    • 84858681408 scopus 로고    scopus 로고
    • Impact of using different tissue classes on the accuracy of MR-based attenuation correction in PET-MRI
    • Akbarzadeh A., Ay M.R., Ahmadian A., Riahi Alam N., Zaidi H. Impact of using different tissue classes on the accuracy of MR-based attenuation correction in PET-MRI. IEEE Nucl Sci Symp Conf Rec 2011, 2524-2530.
    • (2011) IEEE Nucl Sci Symp Conf Rec , pp. 2524-2530
    • Akbarzadeh, A.1    Ay, M.R.2    Ahmadian, A.3    Riahi Alam, N.4    Zaidi, H.5
  • 44
    • 0024341837 scopus 로고
    • On-line brain attenuation correction in PET: towards a fully automated data handling in a clinical environment
    • Michel C., Bol A., DeVolder A.G., Goffinet A.M. On-line brain attenuation correction in PET: towards a fully automated data handling in a clinical environment. Eur J Nucl Med 1989, 15:712-718.
    • (1989) Eur J Nucl Med , vol.15 , pp. 712-718
    • Michel, C.1    Bol, A.2    DeVolder, A.G.3    Goffinet, A.M.4
  • 45
    • 0026901812 scopus 로고
    • Implementation and evaluation of a calculated attenuation correction for PET
    • Siegel S., Dahlbom M. Implementation and evaluation of a calculated attenuation correction for PET. IEEE Trans Nucl Sci 1992, 39:1117-1121.
    • (1992) IEEE Trans Nucl Sci , vol.39 , pp. 1117-1121
    • Siegel, S.1    Dahlbom, M.2
  • 46
    • 0035092988 scopus 로고    scopus 로고
    • Automated PET attenuation correction model for functional brain imaging
    • Weinzapfel B.T., Hutchins G.D. Automated PET attenuation correction model for functional brain imaging. J Nucl Med 2001, 42:483-491.
    • (2001) J Nucl Med , vol.42 , pp. 483-491
    • Weinzapfel, B.T.1    Hutchins, G.D.2
  • 47
    • 0033801296 scopus 로고    scopus 로고
    • Scatter and AC for brain SPECT using attenuation distributions inferred from a head atlas
    • Stodilka R.Z., Kemp B.J., Prato F.S., Kertesz A., Kuhl D., Nicholson R.L. Scatter and AC for brain SPECT using attenuation distributions inferred from a head atlas. J Nucl Med 2000, 41(9):1569-1578.
    • (2000) J Nucl Med , vol.41 , Issue.9 , pp. 1569-1578
    • Stodilka, R.Z.1    Kemp, B.J.2    Prato, F.S.3    Kertesz, A.4    Kuhl, D.5    Nicholson, R.L.6
  • 48
    • 14244251257 scopus 로고    scopus 로고
    • Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging
    • Montandon M.L., Zaidi H. Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging. NeuroImage 2005, 25:278-286.
    • (2005) NeuroImage , vol.25 , pp. 278-286
    • Montandon, M.L.1    Zaidi, H.2
  • 49
    • 63849317451 scopus 로고    scopus 로고
    • Template-based attenuation correction of PET in hybrid MR-PET [abstract]
    • Rota Kops E., Herzog H.R. Template-based attenuation correction of PET in hybrid MR-PET [abstract]. J Nucl Med 2008, 49(Suppl):162P.
    • (2008) J Nucl Med , vol.49 , Issue.SUPPL.
    • Rota Kops, E.1    Herzog, H.R.2
  • 50
    • 57349155316 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration
    • Hofmann M., Steinke F., Scheel V., Charpiat G., Farquhar J., Aschoff P., et al. MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J Nucl Med 2008, 49:1875-1883.
    • (2008) J Nucl Med , vol.49 , pp. 1875-1883
    • Hofmann, M.1    Steinke, F.2    Scheel, V.3    Charpiat, G.4    Farquhar, J.5    Aschoff, P.6
  • 51
    • 77952358732 scopus 로고    scopus 로고
    • MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration
    • Schreibmann E., Nye J.A., Schuster D.M., Martin D.R., Votaw J., Fox T. MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration. Med Phys 2010, 37:2101-2109.
    • (2010) Med Phys , vol.37 , pp. 2101-2109
    • Schreibmann, E.1    Nye, J.A.2    Schuster, D.M.3    Martin, D.R.4    Votaw, J.5    Fox, T.6
  • 52
    • 79960336732 scopus 로고    scopus 로고
    • Attenuation correction methods suitable for brain imaging with a PET/MRI scanner: a comparison of tissue atlas and template attenuation map approaches
    • Malone I.B., Ansorge R.E., Williams G.B., Nestor P.J., Carpenter T.A., Fryer T.D. Attenuation correction methods suitable for brain imaging with a PET/MRI scanner: a comparison of tissue atlas and template attenuation map approaches. J Nucl Med 2011, 52(7):1142-1149.
    • (2011) J Nucl Med , vol.52 , Issue.7 , pp. 1142-1149
    • Malone, I.B.1    Ansorge, R.E.2    Williams, G.B.3    Nestor, P.J.4    Carpenter, T.A.5    Fryer, T.D.6
  • 53
    • 43749114975 scopus 로고    scopus 로고
    • MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data
    • Beyer T., Weigert M., Quick H.H., Pietrzyk U., Vogt F., Palm C., et al. MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data. Eur J Nucl Med 2008, 35:1142-1146.
    • (2008) Eur J Nucl Med , vol.35 , pp. 1142-1146
    • Beyer, T.1    Weigert, M.2    Quick, H.H.3    Pietrzyk, U.4    Vogt, F.5    Palm, C.6
  • 54
    • 80052644918 scopus 로고    scopus 로고
    • MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods
    • Hofmann M., Bezrukov I., Mantlik F., Aschoff P., Steinke F., Beyer T., et al. MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med 2011, 52(9):1392-1399.
    • (2011) J Nucl Med , vol.52 , Issue.9 , pp. 1392-1399
    • Hofmann, M.1    Bezrukov, I.2    Mantlik, F.3    Aschoff, P.4    Steinke, F.5    Beyer, T.6
  • 55
    • 0018457105 scopus 로고
    • A new approach to the emission computerized tomography problem: Simultaneous calculation of attenuation and activity coefficients
    • Censor Y., Gustafson D., Lent A., Tuy H. A new approach to the emission computerized tomography problem: Simultaneous calculation of attenuation and activity coefficients. IEEE Trans Nucl Sci 1979, 26:2275-2279.
    • (1979) IEEE Trans Nucl Sci , vol.26 , pp. 2275-2279
    • Censor, Y.1    Gustafson, D.2    Lent, A.3    Tuy, H.4
  • 56
    • 84988201503 scopus 로고
    • Attenuation Correction in Positron Emission Tomography
    • Natterer F., Herzog H. Attenuation Correction in Positron Emission Tomography. Math Meth Appl Sci 1992, 15:321-330.
    • (1992) Math Meth Appl Sci , vol.15 , pp. 321-330
    • Natterer, F.1    Herzog, H.2
  • 57
    • 0032307814 scopus 로고    scopus 로고
    • Attenuation correction in PET using consistency information
    • Welch A. Attenuation correction in PET using consistency information. IEEE Trans Nucl Sci 1998, 45(6):3134-3141.
    • (1998) IEEE Trans Nucl Sci , vol.45 , Issue.6 , pp. 3134-3141
    • Welch, A.1
  • 58
    • 0032588587 scopus 로고    scopus 로고
    • Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms
    • Nuyts J., Dupont P., Stroobants S., Bennick R., Mortelmans L., Suetens P. Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms. IEEE Trans Med Imaging 1999, 18(5):393-403.
    • (1999) IEEE Trans Med Imaging , vol.18 , Issue.5 , pp. 393-403
    • Nuyts, J.1    Dupont, P.2    Stroobants, S.3    Bennick, R.4    Mortelmans, L.5    Suetens, P.6
  • 59
    • 0033800928 scopus 로고    scopus 로고
    • Simultaneous iterative reconstruction for emission and attenuation images in positron emission tomography
    • Glatting G., Wuchenauer M., Reske S.N. Simultaneous iterative reconstruction for emission and attenuation images in positron emission tomography. Med Phys 2000, 27:2065-2071.
    • (2000) Med Phys , vol.27 , pp. 2065-2071
    • Glatting, G.1    Wuchenauer, M.2    Reske, S.N.3
  • 60
    • 0034178298 scopus 로고    scopus 로고
    • Reconstruction of attenuation map using discrete consistency conditions
    • Bronnikov A.V. Reconstruction of attenuation map using discrete consistency conditions. IEEE Trans Med Imaging 2000, 19:451-462.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 451-462
    • Bronnikov, A.V.1
  • 61
    • 3042745611 scopus 로고    scopus 로고
    • Application of discrete data consistency conditions for selecting regularization parameters in PET attenuation map reconstruction
    • Panin V.Y., Kehren F., Hamill J., Michel C. Application of discrete data consistency conditions for selecting regularization parameters in PET attenuation map reconstruction. Phys Med Biol 2004, 49:2425-2436.
    • (2004) Phys Med Biol , vol.49 , pp. 2425-2436
    • Panin, V.Y.1    Kehren, F.2    Hamill, J.3    Michel, C.4
  • 64
    • 84856853168 scopus 로고    scopus 로고
    • Time-of-flight PET data determine the attenuation sinogram up to a constant
    • Defrise M., Rezaei A., Nuyts J. Time-of-flight PET data determine the attenuation sinogram up to a constant. Phys Med Biol 2012, 57:885-899.
    • (2012) Phys Med Biol , vol.57 , pp. 885-899
    • Defrise, M.1    Rezaei, A.2    Nuyts, J.3
  • 65
    • 77953505299 scopus 로고    scopus 로고
    • The effect of limited MR field of view in MR/PET attenuation correction
    • Delso G., Martinez-Möller A., Bundschuh R., Nekolla S., Ziegler S.I. The effect of limited MR field of view in MR/PET attenuation correction. Med Phys 2010, 37(6):2804-2812.
    • (2010) Med Phys , vol.37 , Issue.6 , pp. 2804-2812
    • Delso, G.1    Martinez-Möller, A.2    Bundschuh, R.3    Nekolla, S.4    Ziegler, S.I.5
  • 70
    • 78049448620 scopus 로고    scopus 로고
    • Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
    • Delso G., Martinez-Möller A., Bundschuh R.A., Ladebeck R., Candidus Y., Faul D., et al. Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner. Phys Med Biol 2010, 55(15):4361-4374.
    • (2010) Phys Med Biol , vol.55 , Issue.15 , pp. 4361-4374
    • Delso, G.1    Martinez-Möller, A.2    Bundschuh, R.A.3    Ladebeck, R.4    Candidus, Y.5    Faul, D.6
  • 72
    • 79959543762 scopus 로고    scopus 로고
    • The effect of MR surface coils on PET quantification in whole-body PET/MR: results from a pseudo-PET/MR phantom study
    • Tellmann L., Quick H.H., Bockisch A., Herzog H., Beyer T. The effect of MR surface coils on PET quantification in whole-body PET/MR: results from a pseudo-PET/MR phantom study. Med Phys 2011, 38(5):2795-2805.
    • (2011) Med Phys , vol.38 , Issue.5 , pp. 2795-2805
    • Tellmann, L.1    Quick, H.H.2    Bockisch, A.3    Herzog, H.4    Beyer, T.5
  • 74
    • 84871200664 scopus 로고    scopus 로고
    • MR/PET Attenuation correction using a multi tissue model for quantification of cardiac uptake: Initial comparison to PET/CT
    • Nekolla S., Souvatzoglou M., Schachoff S., Fürst S., Martinez-Möller A., Ziegler S., et al. MR/PET Attenuation correction using a multi tissue model for quantification of cardiac uptake: Initial comparison to PET/CT. J Nucl Med 2011, 52(Suppl. 1):440.
    • (2011) J Nucl Med , vol.52 , Issue.SUPPL. 1 , pp. 440
    • Nekolla, S.1    Souvatzoglou, M.2    Schachoff, S.3    Fürst, S.4    Martinez-Möller, A.5    Ziegler, S.6
  • 75
    • 84860889359 scopus 로고    scopus 로고
    • First clinical experience of integrated whole-body MR/PET. Comparison to PET/CT in patients with oncological diagnoses
    • Drzezga A., Souvatzoglou M., Eiber M., Beer A.J., Fürst S., Martinez-Möller A., et al. First clinical experience of integrated whole-body MR/PET. Comparison to PET/CT in patients with oncological diagnoses. J Nucl Med 2012, 53(6):845-855.
    • (2012) J Nucl Med , vol.53 , Issue.6 , pp. 845-855
    • Drzezga, A.1    Souvatzoglou, M.2    Eiber, M.3    Beer, A.J.4    Fürst, S.5    Martinez-Möller, A.6
  • 76
    • 80455149956 scopus 로고    scopus 로고
    • Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions
    • Eiber M., Martinez-Möller A., Souvatzoglou M., Holzapfel K., Pickhard A., Löffelbein D., et al. Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions. Eur J Nucl Med Mol Imaging 2011, 38(9):1691-1701.
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , Issue.9 , pp. 1691-1701
    • Eiber, M.1    Martinez-Möller, A.2    Souvatzoglou, M.3    Holzapfel, K.4    Pickhard, A.5    Löffelbein, D.6