메뉴 건너뛰기




Volumn 116, Issue 5, 2013, Pages

Relation between initial implant stability quotient and bone-implant contact percentage: An in vitro model study

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; AUDIOVISUAL EQUIPMENT; BONE; DENTAL PROCEDURE; MICRO-COMPUTED TOMOGRAPHY; PHYSIOLOGY; RADIOGRAPHY; THREE DIMENSIONAL IMAGING; TOOTH IMPLANT; TOOTH PROSTHESIS; YOUNG MODULUS;

EID: 84885426831     PISSN: 22124403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.oooo.2012.01.037     Document Type: Article
Times cited : (29)

References (31)
  • 1
    • 38949214763 scopus 로고    scopus 로고
    • Relationship between implant stability measured by resonance frequency analysis (RFA) and bone loss during early healing period
    • S.M. Yang, S.Y. Shin, and S.B. Kye Relationship between implant stability measured by resonance frequency analysis (RFA) and bone loss during early healing period Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105 2008 e12 e19
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.105
    • Yang, S.M.1    Shin, S.Y.2    Kye, S.B.3
  • 2
    • 62849086385 scopus 로고    scopus 로고
    • A comparative study of two noninvasive techniques to evaluate implant stability: Periotest and Osstell mentor
    • J.S. Oh, S.G. Kim, S.C. Lim, and J.L. Ong A comparative study of two noninvasive techniques to evaluate implant stability: Periotest and Osstell mentor Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107 2009 513 518
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.107 , pp. 513-518
    • Oh, J.S.1    Kim, S.G.2    Lim, S.C.3    Ong, J.L.4
  • 3
    • 77952388063 scopus 로고    scopus 로고
    • Effects of elasticity and structure of trabecular bone on the primary stability of dental implants
    • H.L. Huang, L.J. Fuh, M.G. Tu, and J.T. Hsu Effects of elasticity and structure of trabecular bone on the primary stability of dental implants J Med Biol Eng 30 2010 85 89
    • (2010) J Med Biol Eng , vol.30 , pp. 85-89
    • Huang, H.L.1    Fuh, L.J.2    Tu, M.G.3    Hsu, J.T.4
  • 4
    • 77954363541 scopus 로고    scopus 로고
    • Variations in bone density at dental implant sites in different regions of the jawbone
    • L.J. Fuh, H.L. Huang, C.S. Chen, K.L. Fu, Y.W. Shen, and M.G. Tu Variations in bone density at dental implant sites in different regions of the jawbone J Oral Rehabil 37 2010 346 351
    • (2010) J Oral Rehabil , vol.37 , pp. 346-351
    • Fuh, L.J.1    Huang, H.L.2    Chen, C.S.3    Fu, K.L.4    Shen, Y.W.5    Tu, M.G.6
  • 5
    • 68049132642 scopus 로고    scopus 로고
    • Bone strain and interfacial sliding analyses of platform switching and implant diameter on an immediately loaded implant: Experimental and three-dimensional finite element analyses
    • J.T. Hsu, L.J. Fuh, D.J. Lin, Y.W. Shen, and H.L. Huang Bone strain and interfacial sliding analyses of platform switching and implant diameter on an immediately loaded implant: experimental and three-dimensional finite element analyses J Periodontol 80 2009 1125 1132
    • (2009) J Periodontol , vol.80 , pp. 1125-1132
    • Hsu, J.T.1    Fuh, L.J.2    Lin, D.J.3    Shen, Y.W.4    Huang, H.L.5
  • 6
    • 18744396684 scopus 로고    scopus 로고
    • Implant design and intraosseous stability of immediately placed implants: A human cadaver study
    • M. Akkocaoglu, S. Uysal, I. Tekdemir, K. Akca, and M.C. Cehreli Implant design and intraosseous stability of immediately placed implants: a human cadaver study Clin Oral Implants Res 16 2005 202 209
    • (2005) Clin Oral Implants Res , vol.16 , pp. 202-209
    • Akkocaoglu, M.1    Uysal, S.2    Tekdemir, I.3    Akca, K.4    Cehreli, M.C.5
  • 7
    • 36148965544 scopus 로고    scopus 로고
    • Effect of surgical techniques on primary implant stability and peri-implant bone
    • M.I. Fanuscu, T.L. Chang, and K. Akça Effect of surgical techniques on primary implant stability and peri-implant bone J Oral Maxillofac Surg 65 2007 2487 2491
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 2487-2491
    • Fanuscu, M.I.1    Chang, T.L.2    Akça, K.3
  • 8
    • 60049098379 scopus 로고    scopus 로고
    • Implant stability in relation to osseointegration: An experimental study in the Labrador dog
    • I. Abrahamsson, E. Linder, and N.P. Lang Implant stability in relation to osseointegration: an experimental study in the Labrador dog Clin Oral Implants Res 20 2009 313 318
    • (2009) Clin Oral Implants Res , vol.20 , pp. 313-318
    • Abrahamsson, I.1    Linder, E.2    Lang, N.P.3
  • 9
    • 77649227396 scopus 로고    scopus 로고
    • Influence of the length of the loading period after placement of orthodontic mini-implants on changes in bone histomorphology: Microcomputed tomographic and histologic analysis
    • J.Y. Cha, J.K. Lim, J.W. Song, D. Sato, M. Kenmotsu, T. Inoue, and Y.C. Park Influence of the length of the loading period after placement of orthodontic mini-implants on changes in bone histomorphology: microcomputed tomographic and histologic analysis Int J Oral Maxillofac Implants 24 2009 842 849
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 842-849
    • Cha, J.Y.1    Lim, J.K.2    Song, J.W.3    Sato, D.4    Kenmotsu, M.5    Inoue, T.6    Park, Y.C.7
  • 10
    • 0345304947 scopus 로고    scopus 로고
    • Implant stability and histomorphometry: A correlation study in human cadavers using stepped cylinder implants
    • E. Nkenke, M. Hahn, K. Weinzierl, M. Radespiel-Tröger, F.W. Neukam, and K. Engelke Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants Clin Oral Implants Res 14 2003 601 609
    • (2003) Clin Oral Implants Res , vol.14 , pp. 601-609
    • Nkenke, E.1    Hahn, M.2    Weinzierl, K.3    Radespiel-Tröger, M.4    Neukam, F.W.5    Engelke, K.6
  • 11
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • N. Meredith Assessment of implant stability as a prognostic determinant Int J Prosthodont 11 1998 491 501
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 12
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in vivo A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
    • N. Meredith, K. Book, B. Friberg, T. Jemt, and L. Sennerby Resonance frequency measurements of implant stability in vivo A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla Clin Oral Implants Res 8 1997 226 233
    • (1997) Clin Oral Implants Res , vol.8 , pp. 226-233
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 13
    • 74049114936 scopus 로고    scopus 로고
    • A prospective follow-up study of 44 mandibular immediately loaded implants using resonance frequency analysis: Preliminary 1-year results
    • A.C. Melo, M.C. de Freitas, S.R. Bernardes, I.A. de Mattias Sartori, A.P. Bassi, and G. Thomé A prospective follow-up study of 44 mandibular immediately loaded implants using resonance frequency analysis: preliminary 1-year results Implant Dent 18 2009 530 538
    • (2009) Implant Dent , vol.18 , pp. 530-538
    • Melo, A.C.1    De Freitas, M.C.2    Bernardes, S.R.3    De Mattias Sartori, I.A.4    Bassi, A.P.5    Thomé, G.6
  • 14
    • 37249055018 scopus 로고    scopus 로고
    • Relevance of resonance frequency analysis to evaluate dental implant stability: Simulation and histomorphometrical animal experiments
    • Y. Ito, D. Sato, S. Yoneda, D. Ito, H. Kondo, and S. Kasugai Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments Clin Oral Implants Res 19 2008 9 14
    • (2008) Clin Oral Implants Res , vol.19 , pp. 9-14
    • Ito, Y.1    Sato, D.2    Yoneda, S.3    Ito, D.4    Kondo, H.5    Kasugai, S.6
  • 15
    • 0032059195 scopus 로고    scopus 로고
    • Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability
    • N. Meredith, B. Friberg, L. Sennerby, and C. Aparicio Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability Int J Prosthodont 11 1998 269 275
    • (1998) Int J Prosthodont , vol.11 , pp. 269-275
    • Meredith, N.1    Friberg, B.2    Sennerby, L.3    Aparicio, C.4
  • 16
    • 34547174147 scopus 로고    scopus 로고
    • Relations between the bone density values from computerized tomography, and implant stability parameters: A clinical study of 230 regular platform implants
    • I. Turkyilmaz, C. Tumer, E.N. Ozbek, and T.F. Tözüm Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants J Clin Periodontol 34 2007 716 722
    • (2007) J Clin Periodontol , vol.34 , pp. 716-722
    • Turkyilmaz, I.1    Tumer, C.2    Ozbek, E.N.3    Tözüm, T.F.4
  • 17
    • 26944498359 scopus 로고    scopus 로고
    • An evaluation of resonance frequency analysis for the determination of the primary stability of orthodontic palatal implants A study in human cadavers
    • T. Gedrange, V. Hietschold, R. Mai, P. Wolf, M. Nicklisch, and W. Harzer An evaluation of resonance frequency analysis for the determination of the primary stability of orthodontic palatal implants A study in human cadavers Clin Oral Implants Res 16 2005 425 431
    • (2005) Clin Oral Implants Res , vol.16 , pp. 425-431
    • Gedrange, T.1    Hietschold, V.2    Mai, R.3    Wolf, P.4    Nicklisch, M.5    Harzer, W.6
  • 18
    • 67650892092 scopus 로고    scopus 로고
    • Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants
    • M. Degidi, V. Perrotti, R. Strocchi, A. Piattelli, and G. Iezzi Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants Clin Oral Implants Res 20 2009 778 781
    • (2009) Clin Oral Implants Res , vol.20 , pp. 778-781
    • Degidi, M.1    Perrotti, V.2    Strocchi, R.3    Piattelli, A.4    Iezzi, G.5
  • 19
    • 36049049424 scopus 로고    scopus 로고
    • Roles of bone scintigraphy and resonance frequency analysis in evaluating osseointegration of endosseous implant
    • Y. Zhou, T. Jiang, M. Qian, X. Zhang, J. Wang, and B. Shi Roles of bone scintigraphy and resonance frequency analysis in evaluating osseointegration of endosseous implant Biomaterials 29 2008 461 474
    • (2008) Biomaterials , vol.29 , pp. 461-474
    • Zhou, Y.1    Jiang, T.2    Qian, M.3    Zhang, X.4    Wang, J.5    Shi, B.6
  • 20
    • 33845654011 scopus 로고    scopus 로고
    • Correlation between implant stability quotient and bone-implant contact: A retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans
    • A. Scarano, M. Degidi, G. Iezzi, G. Petrone, and A. Piattelli Correlation between implant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans Clin Implant Dent 8 2006 218 222
    • (2006) Clin Implant Dent , vol.8 , pp. 218-222
    • Scarano, A.1    Degidi, M.2    Iezzi, G.3    Petrone, G.4    Piattelli, A.5
  • 21
    • 79952060388 scopus 로고    scopus 로고
    • Comparison of initial stability parameters and histomorphometric analysis of implants inserted into extraction sockets: Human fresh cadaver study
    • S.H. Jun, B.M. Chang, H.P. Weber, and J.J. Kwon Comparison of initial stability parameters and histomorphometric analysis of implants inserted into extraction sockets: human fresh cadaver study Int J Oral Maxillofac Implants 25 2010 985 990
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 985-990
    • Jun, S.H.1    Chang, B.M.2    Weber, H.P.3    Kwon, J.J.4
  • 22
    • 0033067941 scopus 로고    scopus 로고
    • Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement
    • C.E. Misch, Z. Qu, and M.W. Bidez Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement J Oral Maxillofac Surg 57 1999 700 706
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 700-706
    • Misch, C.E.1    Qu, Z.2    Bidez, M.W.3
  • 23
    • 79959205947 scopus 로고    scopus 로고
    • Initial stability and bone strain evaluation of the immediately loaded dental implant: An in vitro model study
    • H.L. Huang, Y.Y. Chang, D.J. Lin, Y.F. Li, K.T. Chen, and J.T. Hsu Initial stability and bone strain evaluation of the immediately loaded dental implant: an in vitro model study Clin Oral Implants Res 22 2011 691 698
    • (2011) Clin Oral Implants Res , vol.22 , pp. 691-698
    • Huang, H.L.1    Chang, Y.Y.2    Lin, D.J.3    Li, Y.F.4    Chen, K.T.5    Hsu, J.T.6
  • 27
    • 33749606054 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in the dog mandible: Experimental comparison with histomorphometric data
    • H. Schliephake, A. Sewing, and A. Aref Resonance frequency measurements of implant stability in the dog mandible: experimental comparison with histomorphometric data Int J Oral Maxillofac Surg 35 2006 941 946
    • (2006) Int J Oral Maxillofac Surg , vol.35 , pp. 941-946
    • Schliephake, H.1    Sewing, A.2    Aref, A.3
  • 28
    • 0037210170 scopus 로고    scopus 로고
    • Bone formation after 4 weeks around blood-plasma-modified titanium implants with varying surface topographies: An in vivo study
    • A. Göransson, E. Jansson, P. Tengvall, and A. Wennerberg Bone formation after 4 weeks around blood-plasma-modified titanium implants with varying surface topographies: an in vivo study Biomaterials 24 2003 197 205
    • (2003) Biomaterials , vol.24 , pp. 197-205
    • Göransson, A.1    Jansson, E.2    Tengvall, P.3    Wennerberg, A.4
  • 29
    • 33746375362 scopus 로고    scopus 로고
    • Biomechanical aspects of initial intraosseous stability and implant design: A quantitative micro-morphometric analysis
    • K. Akça, T.L. Chang, I. Tekdemir, and M.I. Fanuscu Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis Clin Oral Implants Res 17 2006 465 472
    • (2006) Clin Oral Implants Res , vol.17 , pp. 465-472
    • Akça, K.1    Chang, T.L.2    Tekdemir, I.3    Fanuscu, M.I.4
  • 30
    • 33644863108 scopus 로고    scopus 로고
    • The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model
    • M.M. Shalabi, J.G. Wolke, and J.A. Jansen The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model Clin Oral Implants Res 17 2006 172 178
    • (2006) Clin Oral Implants Res , vol.17 , pp. 172-178
    • Shalabi, M.M.1    Wolke, J.G.2    Jansen, J.A.3
  • 31
    • 35748952794 scopus 로고    scopus 로고
    • The number of screws, bone quality, and friction coefficient affect acetabular cup stability
    • J.T. Hsu, C.H. Chang, H.L. Huang, M.E. Zobitz, W.P. Chen, K.A. Lai, and K.N. An The number of screws, bone quality, and friction coefficient affect acetabular cup stability Med Eng Phys 29 2007 1089 1095
    • (2007) Med Eng Phys , vol.29 , pp. 1089-1095
    • Hsu, J.T.1    Chang, C.H.2    Huang, H.L.3    Zobitz, M.E.4    Chen, W.P.5    Lai, K.A.6    An, K.N.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.