메뉴 건너뛰기




Volumn 24, Issue 5, 2009, Pages 842-849

Influence of the length of the loading period after placement of orthodontic mini-implants on changes in bone histomorphology: Microcomputed tomographic and histologic analysis

Author keywords

Histomorphometry; Microcomputed tomography; Mini implant

Indexed keywords

ANIMAL; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE REGENERATION; COMPARATIVE STUDY; DOG; IMAGE PROCESSING; INSTRUMENTATION; MALE; MANDIBLE; MECHANICAL STRESS; METHODOLOGY; MICRO-COMPUTED TOMOGRAPHY; ORTHODONTICS; PATHOLOGY; PHYSIOLOGY; RADIOGRAPHY; THREE DIMENSIONAL IMAGING; TIME; TOOTH IMPLANTATION;

EID: 77649227396     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (37)
  • 1
    • 1042284432 scopus 로고    scopus 로고
    • Immediate loading of implants used for orthodontic anchorage
    • Melsen B, Costa A. Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res 2000; 3: 23-28.
    • (2000) Clin Orthod Res , vol.3 , pp. 23-28
    • Melsen, B.1    Costa, A.2
  • 3
    • 0030325414 scopus 로고    scopus 로고
    • The use of palatal implants for orthodontic anchorage. Design and clinical application of the Orthosystem
    • Wehrbein H, Merz BR, Diedrich P, Glatzmaier J. The use of palatal implants for orthodontic anchorage. Design and clinical application of the Orthosystem. Clin Oral Implants Res 1996; 7: 410-416.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 410-416
    • Wehrbein, H.1    Merz, B.R.2    Diedrich, P.3    Glatzmaier, J.4
  • 4
    • 7044264818 scopus 로고    scopus 로고
    • Sliding mechanics with microscrew implant anchorage
    • Park HS, Kwon TG. Sliding mechanics with microscrew implant anchorage. Angle Orthod 2004; 74: 703-710.
    • (2004) Angle Orthod , vol.74 , pp. 703-710
    • Park, H.S.1    Kwon, T.G.2
  • 5
    • 33744458766 scopus 로고    scopus 로고
    • Parameters affecting primary stability of orthodontic mini-implants
    • Wilmes B, Rademacher C, Olthoff G, Drescher D. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 2006; 67: 162-174.
    • (2006) J Orofac Orthop , vol.67 , pp. 162-174
    • Wilmes, B.1    Rademacher, C.2    Olthoff, G.3    Drescher, D.4
  • 7
    • 28644442241 scopus 로고    scopus 로고
    • Histologic and histomorphometric findings from retrieved, immediately occlusally loaded implants in humans
    • Romanos GE, Testori T, Degidi M, Piattelli A. Histologic and histomorphometric findings from retrieved, immediately occlusally loaded implants in humans. J Periodontol 2005; 76: 1823-1832.
    • (2005) J Periodontol , vol.76 , pp. 1823-1832
    • Romanos, G.E.1    Testori, T.2    Degidi, M.3    Piattelli, A.4
  • 8
    • 0024198247 scopus 로고
    • Bone tissue interface
    • Roberts WE. Bone tissue interface. J Dent Educ 1988; 52: 804-809.
    • (1988) J Dent Educ , vol.52 , pp. 804-809
    • Roberts, W.E.1
  • 9
    • 0033002343 scopus 로고    scopus 로고
    • A non-destructive technique for 3-D microstructural phenotypic characterisation of bones in genetically altered mice: Preliminary data in growth hormone transgenic animals and normal controls
    • Graichen H, Lochmuller EM, Wolf E, et al. A non-destructive technique for 3-D microstructural phenotypic characterisation of bones in genetically altered mice: Preliminary data in growth hormone transgenic animals and normal controls. Anat Embryol (Berl) 1999; 199: 239-248.
    • (1999) Anat Embryol (Berl) , vol.199 , pp. 239-248
    • Graichen, H.1    Lochmuller, E.M.2    Wolf, E.3
  • 10
    • 18744406031 scopus 로고    scopus 로고
    • Correlation between microtomography and histomorphometry for assessment of implant osseointegration
    • Park YS, Yi KY, Lee IS, Jung YC. Correlation between microtomography and histomorphometry for assessment of implant osseointegration. Clin Oral Implants Res 2005; 16: 156-160.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 156-160
    • Park, Y.S.1    Yi, K.Y.2    Lee, I.S.3    Jung, Y.C.4
  • 12
    • 0034585175 scopus 로고    scopus 로고
    • Use of microfocus computerized tomography as a new technique for characterizing bone tissue around oral implants
    • Van Oossterwyck H, Duyck J, Vander Sloten J, et al. Use of microfocus computerized tomography as a new technique for characterizing bone tissue around oral implants. J Oral Implantol 2000; 26: 5-12.
    • (2000) J Oral Implantol , vol.26 , pp. 5-12
    • Van Oossterwyck, H.1    Duyck, J.2    Vander Sloten, J.3
  • 13
    • 0038749451 scopus 로고    scopus 로고
    • Potential application of high-resolution microfocus X-ray techniques for observation of bone structure and boneimplant interface
    • Kiba H, Hayakawa T, Oba S, Kuwabara M, Habata I, Yamamoto H. Potential application of high-resolution microfocus X-ray techniques for observation of bone structure and boneimplant interface. Int J Oral Maxillofac Implants 2003; 18: 279-285.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 279-285
    • Kiba, H.1    Hayakawa, T.2    Oba, S.3    Kuwabara, M.4    Habata, I.5    Yamamoto, H.6
  • 14
    • 0345596449 scopus 로고    scopus 로고
    • Morphometric analysis of human bone biopsies: A quantitative structural comparison of histological sections and micro-computed tomography
    • Muller R, Van Campenhout H, Van Damme B, et al. Morphometric analysis of human bone biopsies: A quantitative structural comparison of histological sections and micro-computed tomography. Bone 1998; 23: 59-66.
    • (1998) Bone , vol.23 , pp. 59-66
    • Muller, R.1    Van Campenhout, H.2    Van Damme, B.3
  • 15
    • 33744969864 scopus 로고    scopus 로고
    • Effect of controlled early implant loading on bone healing and bone mass in guinea pigs, as assessed by micro-CT and histology
    • De Smet E, Jaecques SV, Wevers M, et al. Effect of controlled early implant loading on bone healing and bone mass in guinea pigs, as assessed by micro-CT and histology. Eur J Oral Sci 2006; 114: 232-242.
    • (2006) Eur J Oral Sci , vol.114 , pp. 232-242
    • De Smet, E.1    Jaecques, S.V.2    Wevers, M.3
  • 16
    • 10644287805 scopus 로고    scopus 로고
    • Osteoconductive modifications of Ti-implants in a goat defect model: Characterization of bone growth with SR muCT and histology
    • Bernhardt R, van den Dolder J, Bierbaum S, et al. Osteoconductive modifications of Ti-implants in a goat defect model: Characterization of bone growth with SR muCT and histology. Biomaterials 2005; 26: 3009-3019.
    • (2005) Biomaterials , vol.26 , pp. 3009-3019
    • Bernhardt, R.1    van den Dolder, J.2    Bierbaum, S.3
  • 17
    • 3042802525 scopus 로고    scopus 로고
    • A low-temperature biomimetic calcium phosphate surface enhances early implant fixation in a rat model
    • Kuroda S, Virdi AS, Li P, Healy KE, Sumner DR. A low-temperature biomimetic calcium phosphate surface enhances early implant fixation in a rat model. J Biomed Mater Res A 2004; 70: 66-73.
    • (2004) J Biomed Mater Res A , vol.70 , pp. 66-73
    • Kuroda, S.1    Virdi, A.S.2    Li, P.3    Healy, K.E.4    Sumner, D.R.5
  • 18
    • 0033175895 scopus 로고    scopus 로고
    • The effects of operator technique and bur design on temperature during osseous preparation for osteosynthesis self-tapping screws
    • Kerawala CJ, Martin IC, Allan W, Williams ED. The effects of operator technique and bur design on temperature during osseous preparation for osteosynthesis self-tapping screws. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1999; 88: 145-150.
    • (1999) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.88 , pp. 145-150
    • Kerawala, C.J.1    Martin, I.C.2    Allan, W.3    Williams, E.D.4
  • 19
    • 0036184391 scopus 로고    scopus 로고
    • AO self-drilling and self-tapping screws in rat calvarial bone: An ultrastructural study of the implant interface
    • Sowden D, Schmitz JP. AO self-drilling and self-tapping screws in rat calvarial bone: An ultrastructural study of the implant interface. J Oral Maxillofac Surg 2002; 60: 294-299.
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 294-299
    • Sowden, D.1    Schmitz, J.P.2
  • 22
    • 68349090758 scopus 로고    scopus 로고
    • Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants
    • Park H. Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants. Korea J Orthod 2006; 36: 16-29.
    • (2006) Korea J Orthod , vol.36 , pp. 16-29
    • Park, H.1
  • 23
    • 5144223585 scopus 로고    scopus 로고
    • Comparison of microfocus-and synchrotron X-ray tomography for the analysis of osteointegration around Ti6Al4V implants
    • Bernhardt R, Scharnweber D, Muller B, et al. Comparison of microfocus-and synchrotron X-ray tomography for the analysis of osteointegration around Ti6Al4V implants. Eur Cell Mater 2004; 7: 42-51.
    • (2004) Eur Cell Mater , vol.7 , pp. 42-51
    • Bernhardt, R.1    Scharnweber, D.2    Muller, B.3
  • 25
    • 34249882779 scopus 로고    scopus 로고
    • Histomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage
    • Freire JN, Silva NR, Gil JN, Magini RS, Coelho PG. Histomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage. Am J Orthod Dentofacial Orthop 2007; 131: 704.e1-e9.
    • (2007) Am J Orthod Dentofacial Orthop , vol.131
    • Freire, J.N.1    Silva, N.R.2    Gil, J.N.3    Magini, R.S.4    Coelho, P.G.5
  • 26
    • 34547305979 scopus 로고    scopus 로고
    • Biological and biomechanical evaluation of interface reaction at conical screw-type implants
    • Buchter A, Joos U, Wiesmann HP, Seper L, Meyer U. Biological and biomechanical evaluation of interface reaction at conical screw-type implants. Head Face Med 2006; 2: 5.
    • (2006) Head Face Med , vol.2 , pp. 5
    • Buchter, A.1    Joos, U.2    Wiesmann, H.P.3    Seper, L.4    Meyer, U.5
  • 27
    • 0342601513 scopus 로고    scopus 로고
    • Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat
    • Branemark R, Ohrnell L-O, Nilsson P, Thomsen P. Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat. Biomaterials 1997; 18: 969-978.
    • (1997) Biomaterials , vol.18 , pp. 969-978
    • Branemark, R.1    Ohrnell, L.-O.2    Nilsson, P.3    Thomsen, P.4
  • 28
    • 0032052556 scopus 로고    scopus 로고
    • Does microdamage accumulation affect the mechanical properties of bone?
    • Burr DB, Turner CH, Naick P, et al. Does microdamage accumulation affect the mechanical properties of bone? J Biomech 1998; 31: 337-345.
    • (1998) J Biomech , vol.31 , pp. 337-345
    • Burr, D.B.1    Turner, C.H.2    Naick, P.3
  • 30
    • 2342508008 scopus 로고    scopus 로고
    • Microdamage and bone strength
    • Burr D. Microdamage and bone strength. Osteoporos Int 2003; 14: S67-S72.
    • (2003) Osteoporos Int , vol.14 , pp. S67-S72
    • Burr, D.1
  • 31
    • 0029439224 scopus 로고
    • Remodeling dynamics of bone supporting rigidly fixed titanium implants: A histomorphometric comparison in four species including humans
    • Garetto LP, Chen J, Parr JA, Roberts WE. Remodeling dynamics of bone supporting rigidly fixed titanium implants: A histomorphometric comparison in four species including humans. Implant Dent 1995; 4: 235-243.
    • (1995) Implant Dent , vol.4 , pp. 235-243
    • Garetto, L.P.1    Chen, J.2    Parr, J.A.3    Roberts, W.E.4
  • 32
    • 0022067362 scopus 로고
    • Force degradation of orthodontic elastomeric chains-A product comparison study
    • De Genova DC, McInnes-Ledoux P, Weinberg R, Shaye R. Force degradation of orthodontic elastomeric chains-A product comparison study. Am J Orthod 1985; 87: 377-384.
    • (1985) Am J Orthod , vol.87 , pp. 377-384
    • De Genova, D.C.1    McInnes-Ledoux, P.2    Weinberg, R.3    Shaye, R.4
  • 35
    • 37449028311 scopus 로고    scopus 로고
    • Biomechanical and histological comparison of self-drilling and self-tapping orthodontic microimplants in dogs
    • Chen Y, Shin H-I, Kyung H-M. Biomechanical and histological comparison of self-drilling and self-tapping orthodontic microimplants in dogs. Am J Orthod Dentofacial Orthop 2008; 133: 44-50.
    • (2008) Am J Orthod Dentofacial Orthop , vol.133 , pp. 44-50
    • Chen, Y.1    Shin, H.-I.2    Kyung, H.-M.3
  • 36
    • 0031913789 scopus 로고    scopus 로고
    • Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws
    • Heidemann W, Gerlach KL, Grobel KH, Kollner HG. Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws. J Craniomaxillofac Surg 1998; 26: 50-55.
    • (1998) J Craniomaxillofac Surg , vol.26 , pp. 50-55
    • Heidemann, W.1    Gerlach, K.L.2    Grobel, K.H.3    Kollner, H.G.4
  • 37
    • 0034025662 scopus 로고    scopus 로고
    • Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws
    • Brown GA, McCarthy T, Bourgeault CA, Callahan DJ. Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws. J Orthop Res 2000; 18: 307-312.
    • (2000) J Orthop Res , vol.18 , pp. 307-312
    • Brown, G.A.1    McCarthy, T.2    Bourgeault, C.A.3    Callahan, D.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.