-
1
-
-
54749118597
-
A rational approach to perioperative fluid management
-
18813052 10.1097/ALN.0b013e3181863117
-
Chappell D, Jacob M, Hofmann-Kiefer K, Conzen P, Rehm M. A rational approach to perioperative fluid management. Anesthesiology. 2008;109(4):723-40.
-
(2008)
Anesthesiology
, vol.109
, Issue.4
, pp. 723-740
-
-
Chappell, D.1
Jacob, M.2
Hofmann-Kiefer, K.3
Conzen, P.4
Rehm, M.5
-
2
-
-
0036139802
-
Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures
-
11881887 10.1093/bja/88.1.65 1:STN:280:DC%2BD387kslaisQ%3D%3D
-
Venn R, Steele A, Richardson P, Poloniecki J, Grounds M, Newman P. Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth. 2002;88(1):65-71.
-
(2002)
Br J Anaesth
, vol.88
, Issue.1
, pp. 65-71
-
-
Venn, R.1
Steele, A.2
Richardson, P.3
Poloniecki, J.4
Grounds, M.5
Newman, P.6
-
3
-
-
27744442396
-
Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery
-
16155038 10.1093/bja/aei223 1:STN:280:DC%2BD2MrjslOjtQ%3D%3D
-
Wakeling HG, McFall MR, Jenkins CS, Woods WG, Miles WF, Barclay GR, Fleming SC. Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery. Br J Anaesth. 2005;95(5):634-42.
-
(2005)
Br J Anaesth
, vol.95
, Issue.5
, pp. 634-642
-
-
Wakeling, H.G.1
McFall, M.R.2
Jenkins, C.S.3
Woods, W.G.4
Miles, W.F.5
Barclay, G.R.6
Fleming, S.C.7
-
4
-
-
47549096309
-
Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
-
18628220 10.1378/chest.07-2331
-
Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134(1):172-8.
-
(2008)
Chest
, vol.134
, Issue.1
, pp. 172-178
-
-
Marik, P.E.1
Baram, M.2
Vahid, B.3
-
5
-
-
12144287425
-
Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
-
15090949 10.1097/01.CCM.0000114996.68110.C9
-
Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, Neumann A, Ali A, Cheang M, Kavinsky C, Parrillo JE. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med. 2004;32(3):691-9.
-
(2004)
Crit Care Med
, vol.32
, Issue.3
, pp. 691-699
-
-
Kumar, A.1
Anel, R.2
Bunnell, E.3
Habet, K.4
Zanotti, S.5
Marshall, S.6
Neumann, A.7
Ali, A.8
Cheang, M.9
Kavinsky, C.10
Parrillo, J.E.11
-
6
-
-
0035092478
-
Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
-
11243970 10.1378/chest.119.3.867 1:STN:280:DC%2BD3M3hs1Giuw%3D%3D
-
Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest. 2001;119(3):867-73.
-
(2001)
Chest
, vol.119
, Issue.3
, pp. 867-873
-
-
Feissel, M.1
Michard, F.2
Mangin, I.3
Ruyer, O.4
Faller, J.P.5
Teboul, J.L.6
-
7
-
-
23744504093
-
Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
-
16100177 10.1378/chest.128.2.848
-
Hofer CK, Muller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest. 2005;128(2):848-54.
-
(2005)
Chest
, vol.128
, Issue.2
, pp. 848-854
-
-
Hofer, C.K.1
Muller, S.M.2
Furrer, L.3
Klaghofer, R.4
Genoni, M.5
Zollinger, A.6
-
8
-
-
24744434154
-
Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients
-
16163911 10.1017/S0265021505001092 1:STN:280:DC%2BD2MvptlSrsw%3D%3D
-
Wiesenack C, Fiegl C, Keyser A, Prasser C, Keyl C. Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anaesthesiol. 2005;22(9):658-65.
-
(2005)
Eur J Anaesthesiol
, vol.22
, Issue.9
, pp. 658-665
-
-
Wiesenack, C.1
Fiegl, C.2
Keyser, A.3
Prasser, C.4
Keyl, C.5
-
9
-
-
27144504066
-
Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients
-
16277719 10.1186/cc3799
-
Cannesson M, Besnard C, Durand PG, Bohe J, Jacques D. Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients. Crit Care. 2005;9(5):R562-8.
-
(2005)
Crit Care
, vol.9
, Issue.5
-
-
Cannesson, M.1
Besnard, C.2
Durand, P.G.3
Bohe, J.4
Jacques, D.5
-
10
-
-
56849106745
-
Using ventilation-induced plethysmographic variations to optimize patient fluid status
-
18997528 10.1097/ACO.0b013e32831504ca
-
Desebbe O, Cannesson M. Using ventilation-induced plethysmographic variations to optimize patient fluid status. Curr Opin Anaesthesiol. 2008;21(6):772-8.
-
(2008)
Curr Opin Anaesthesiol
, vol.21
, Issue.6
, pp. 772-778
-
-
Desebbe, O.1
Cannesson, M.2
-
11
-
-
47249097004
-
Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre
-
18522935 10.1093/bja/aen133 1:STN:280:DC%2BD1cvktVeksA%3D%3D
-
Cannesson M, Desebbe O, Rosamel P, Delannoy B, Robin J, Bastien O, Lehot JJ. Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. Br J Anaesth. 2008;101(2):200-6.
-
(2008)
Br J Anaesth
, vol.101
, Issue.2
, pp. 200-206
-
-
Cannesson, M.1
Desebbe, O.2
Rosamel, P.3
Delannoy, B.4
Robin, J.5
Bastien, O.6
Lehot, J.J.7
-
12
-
-
84862175860
-
Use of plethysmographic variability index derived from the Massimo((R)) pulse oximeter to predict fluid or preload responsiveness: A systematic review and meta-analysis
-
22452345 10.1111/j.1365-2044.2012.07117.x 1:STN:280: DC%2BC38vpvFKltA%3D%3D [Meta-Analysis Research Support, Non-U.S. Gov't Review]
-
Yin JY, Ho KM. Use of plethysmographic variability index derived from the Massimo((R)) pulse oximeter to predict fluid or preload responsiveness: a systematic review and meta-analysis. Anaesthesia. 2012;67(7):777-83. [Meta-Analysis Research Support, Non-U.S. Gov't Review].
-
(2012)
Anaesthesia
, vol.67
, Issue.7
, pp. 777-783
-
-
Yin, J.Y.1
Ho, K.M.2
-
13
-
-
84856268441
-
Is the pleth variability index a surrogate for pulse pressure variation in a pediatric population undergoing spine fusion?
-
22142032 10.1111/j.1460-9592.2011.03745.x
-
Feldman JM, Sussman E, Singh D, Friedman BJ. Is the pleth variability index a surrogate for pulse pressure variation in a pediatric population undergoing spine fusion? Paediatr Anaesth. 2012;22(3):250-5.
-
(2012)
Paediatr Anaesth
, vol.22
, Issue.3
, pp. 250-255
-
-
Feldman, J.M.1
Sussman, E.2
Singh, D.3
Friedman, B.J.4
-
14
-
-
0024389972
-
Blood pressure and cerebral haemorrhage and ischaemia in very low birthweight infants
-
2737101 10.1016/0378-3782(89)90120-5 1:STN:280:DyaL1M3ovFCmtQ%3D%3D
-
Watkins AM, West CR, Cooke RW. Blood pressure and cerebral haemorrhage and ischaemia in very low birthweight infants. Early Hum Dev. 1989;19(2):103-10.
-
(1989)
Early Hum Dev
, vol.19
, Issue.2
, pp. 103-110
-
-
Watkins, A.M.1
West, C.R.2
Cooke, R.W.3
-
15
-
-
0019489860
-
Aortic blood pressure during the first 12 hours of life in infants with birth weight 610 to 4,220 grams
-
7254989 1:STN:280:DyaL3M3ks1Grtg%3D%3D [Comparative Study Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, H.S.]
-
Versmold HT, Kitterman JA, Phibbs RH, Gregory GA, Tooley WH. Aortic blood pressure during the first 12 hours of life in infants with birth weight 610 to 4,220 grams. Pediatrics. 1981;67(5):607-13. [Comparative Study Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, P.H.S.].
-
(1981)
Pediatrics
, vol.67
, Issue.5
, pp. 607-613
-
-
Versmold, H.T.1
Kitterman, J.A.2
Phibbs, R.H.3
Gregory, G.A.4
Tooley, W.H.5
-
16
-
-
0032753466
-
Blood pressure measurements in the newborn
-
10572732 1:STN:280:DC%2BD3c%2FjvFShtQ%3D%3D
-
Nuntnarumit P, Yang W, Bada-Ellzey HS. Blood pressure measurements in the newborn. Clin Perinatol. 1999;26(4):981-96.
-
(1999)
Clin Perinatol
, vol.26
, Issue.4
, pp. 981-996
-
-
Nuntnarumit, P.1
Yang, W.2
Bada-Ellzey, H.S.3
-
17
-
-
41349123564
-
Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms?
-
18349191 10.1213/ane.0b013e318167ab1f table of contents
-
Cannesson M, Delannoy B, Morand A, Rosamel P, Attof Y, Bastien O, Lehot JJ. Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms? Anesth Analg. 2008;106(4):1189-94. table of contents.
-
(2008)
Anesth Analg
, vol.106
, Issue.4
, pp. 1189-1194
-
-
Cannesson, M.1
Delannoy, B.2
Morand, A.3
Rosamel, P.4
Attof, Y.5
Bastien, O.6
Lehot, J.J.7
-
18
-
-
0020569289
-
Water distribution in the foetus and newborn infant
-
6351536 10.1111/j.1651-2227.1983.tb09852.x 1:STN:280:DyaL3szgsV2nuw%3D%3D
-
Friis-Hansen B. Water distribution in the foetus and newborn infant. Acta Paediatr Scand Suppl. 1983;305:7-11.
-
(1983)
Acta Paediatr Scand Suppl
, vol.305
, pp. 7-11
-
-
Friis-Hansen, B.1
-
19
-
-
79952113754
-
Neonatal fluid management
-
21033013 10.1016/j.bpa.2010.02.014
-
Murat I, Humblot A, Girault L, Piana F. Neonatal fluid management. Best Pract Res Clin Anaesthesiol. 2010;24(3):365-74.
-
(2010)
Best Pract Res Clin Anaesthesiol
, vol.24
, Issue.3
, pp. 365-374
-
-
Murat, I.1
Humblot, A.2
Girault, L.3
Piana, F.4
-
20
-
-
33744512099
-
Cardiovascular support of the sick neonate
-
10.1016/j.cupe.2006.03.010
-
Mupanemunda RH. Cardiovascular support of the sick neonate. Current Paediatrics. 2006;16(3):176-81.
-
(2006)
Current Paediatrics
, vol.16
, Issue.3
, pp. 176-181
-
-
Mupanemunda, R.H.1
-
22
-
-
41349122492
-
The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room
-
18349192 10.1213/01.ane.0000297291.01615.5c table of contents
-
Cannesson M, Slieker J, Desebbe O, Bauer C, Chiari P, Henaine R, Lehot JJ. The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room. Anesth Analg. 2008;106(4):1195-200. table of contents.
-
(2008)
Anesth Analg
, vol.106
, Issue.4
, pp. 1195-1200
-
-
Cannesson, M.1
Slieker, J.2
Desebbe, O.3
Bauer, C.4
Chiari, P.5
Henaine, R.6
Lehot, J.J.7
-
23
-
-
77957721641
-
Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management
-
20705785
-
Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010;111(4):910-4.
-
(2010)
Anesth Analg
, vol.111
, Issue.4
, pp. 910-914
-
-
Forget, P.1
Lois, F.2
De Kock, M.3
-
24
-
-
80054801542
-
First day of life reference values for pleth variability index in spontaneously breathing term newborns
-
22024762 10.1159/000331774
-
Latini G, Dipaola L, De Felice C. First day of life reference values for pleth variability index in spontaneously breathing term newborns. Neonatology. 2012;101(3):179-82.
-
(2012)
Neonatology
, vol.101
, Issue.3
, pp. 179-182
-
-
Latini, G.1
Dipaola, L.2
De Felice, C.3
-
25
-
-
26444447577
-
Noninvasive monitoring of peripheral perfusion
-
16170543 10.1007/s00134-005-2790-2
-
Lima A, Bakker J. Noninvasive monitoring of peripheral perfusion. Intensive Care Med. 2005;31(10):1316-26.
-
(2005)
Intensive Care Med
, vol.31
, Issue.10
, pp. 1316-1326
-
-
Lima, A.1
Bakker, J.2
-
26
-
-
33746529977
-
What is the best site for measuring the effect of ventilation on the pulse oximeter waveform?
-
16861419 10.1213/01.ane.0000222477.67637.17 table of contents
-
Shelley KH, Jablonka DH, Awad AA, Stout RG, Rezkanna H, Silverman DG. What is the best site for measuring the effect of ventilation on the pulse oximeter waveform? Anesth Analg. 2006;103(2):372-7. table of contents.
-
(2006)
Anesth Analg
, vol.103
, Issue.2
, pp. 372-377
-
-
Shelley, K.H.1
Jablonka, D.H.2
Awad, A.A.3
Stout, R.G.4
Rezkanna, H.5
Silverman, D.G.6
-
27
-
-
77949290710
-
The ability of pleth variability index to predict the hemodynamic effects of positive end-expiratory pressure in mechanically ventilated patients under general anesthesia
-
20185658 10.1213/ANE.0b013e3181cd6d06
-
Desebbe O, Boucau C, Farhat F, Bastien O, Lehot JJ, Cannesson M. The ability of pleth variability index to predict the hemodynamic effects of positive end-expiratory pressure in mechanically ventilated patients under general anesthesia. Anesth Analg. 2010;110(3):792-8.
-
(2010)
Anesth Analg
, vol.110
, Issue.3
, pp. 792-798
-
-
Desebbe, O.1
Boucau, C.2
Farhat, F.3
Bastien, O.4
Lehot, J.J.5
Cannesson, M.6
-
28
-
-
77950497478
-
Pleth variability index predicts hypotension during anesthesia induction
-
20236098 10.1111/j.1399-6576.2010.02225.x 1:CAS:528:DC%2BC3cXmtFCrsLY%3D
-
Tsuchiya M, Yamada T, Asada A. Pleth variability index predicts hypotension during anesthesia induction. Acta Anaesthesiol Scand. 2010;54(5):596-602.
-
(2010)
Acta Anaesthesiol Scand
, vol.54
, Issue.5
, pp. 596-602
-
-
Tsuchiya, M.1
Yamada, T.2
Asada, A.3
-
29
-
-
77953799075
-
Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery
-
20035228 1:CAS:528:DC%2BC3cXnvFKns7w%3D
-
Zimmermann M, Feibicke T, Keyl C, Prasser C, Moritz S, Graf BM, Wiesenack C. Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery. Eur J Anaesthesiol. 2010;27(6):555-61.
-
(2010)
Eur J Anaesthesiol
, vol.27
, Issue.6
, pp. 555-561
-
-
Zimmermann, M.1
Feibicke, T.2
Keyl, C.3
Prasser, C.4
Moritz, S.5
Graf, B.M.6
Wiesenack, C.7
-
30
-
-
33747619832
-
Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: Is the perfusion index of any value?
-
16810522 10.1007/s00134-006-0254-y
-
Hummler HD, Engelmann A, Pohlandt F, Hogel J, Franz AR. Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: is the perfusion index of any value? Intensive Care Med. 2006;32(9):1428-31.
-
(2006)
Intensive Care Med
, vol.32
, Issue.9
, pp. 1428-1431
-
-
Hummler, H.D.1
Engelmann, A.2
Pohlandt, F.3
Hogel, J.4
Franz, A.R.5
|