Technical note: Heterogeneity dose calculation accuracy in IMRT: study of five commercial treatment planning systems using an anthropomorphic thorax phantom
-
Davidson S.E., Popple R.A., Ibbott G.S., Followill D.S. Technical note: Heterogeneity dose calculation accuracy in IMRT: study of five commercial treatment planning systems using an anthropomorphic thorax phantom. Med Phys 2008, 35:5434-5439.
-
(2008)
Med Phys
, vol.35
, pp. 5434-5439
-
-
Davidson, S.E.1
Popple, R.A.2
Ibbott, G.S.3
Followill, D.S.4
-
2
-
-
84884357213
-
-
American Association of Physicists in Medicine Report No 85: Tissue inhomogeneity corrections for megavoltage photon beams. Madison, WI.
-
American Association of Physicists in Medicine Report No 85: Tissue inhomogeneity corrections for megavoltage photon beams. Madison, WI; 2004.
-
(2004)
-
-
-
3
-
-
33748881814
-
Dose distributions in SBRT of lung tumors: comparison between two different treatment planning algorithms and Monte-Carlo simulation including breathing motions
-
Lax I., Panettieri V., Wennberg B., et al. Dose distributions in SBRT of lung tumors: comparison between two different treatment planning algorithms and Monte-Carlo simulation including breathing motions. Acta Oncol 2006, 45:978-988.
-
(2006)
Acta Oncol
, vol.45
, pp. 978-988
-
-
Lax, I.1
Panettieri, V.2
Wennberg, B.3
-
4
-
-
33748297735
-
Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations
-
Vanderstraeten B., Reynaert N., Paelinck L., et al. Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations. Med Phys 2006, 33:3149-3158.
-
(2006)
Med Phys
, vol.33
, pp. 3149-3158
-
-
Vanderstraeten, B.1
Reynaert, N.2
Paelinck, L.3
-
5
-
-
44449122864
-
Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife
-
Wilcox E.E., Daskalov G.M. Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife. Med Phys 2008, 35:2259-2266.
-
(2008)
Med Phys
, vol.35
, pp. 2259-2266
-
-
Wilcox, E.E.1
Daskalov, G.M.2
-
6
-
-
2542481005
-
Modelling 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning
-
Deng J., Guerrero T., Ma C.M., Nath R. Modelling 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning. Phys Med Biol 2004, 49:1689-1704.
-
(2004)
Phys Med Biol
, vol.49
, pp. 1689-1704
-
-
Deng, J.1
Guerrero, T.2
Ma, C.M.3
Nath, R.4
-
7
-
-
0347625750
-
Commissioning 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning
-
Deng J., Ma C.M., Hai J., Nath R. Commissioning 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning. Med Phys 2003, 30:3124-3134.
-
(2003)
Med Phys
, vol.30
, pp. 3124-3134
-
-
Deng, J.1
Ma, C.M.2
Hai, J.3
Nath, R.4
-
8
-
-
78149333546
-
Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning
-
Fragoso M., Wen N., Kumar S., et al. Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning. Phys Med Biol 2010, 55:4445-4464.
-
(2010)
Phys Med Biol
, vol.55
, pp. 4445-4464
-
-
Fragoso, M.1
Wen, N.2
Kumar, S.3
-
9
-
-
0032435894
-
Monte Carlo treatment planning for stereotactic radiosurgery
-
Solberg T.D., DeMarco J.J., Holly F.E., Smathers J.B., DeSalles A.A. Monte Carlo treatment planning for stereotactic radiosurgery. Radiother Oncol 1998, 49:73-84.
-
(1998)
Radiother Oncol
, vol.49
, pp. 73-84
-
-
Solberg, T.D.1
DeMarco, J.J.2
Holly, F.E.3
Smathers, J.B.4
DeSalles, A.A.5
-
10
-
-
77957190458
-
Stereotactic, single-dose irradiation of lung tumors: a comparison of absolute dose and dose distribution between pencil beam and Monte Carlo algorithms based on actual patient CT scans
-
Chen H., Lohr F., Fritz P., et al. Stereotactic, single-dose irradiation of lung tumors: a comparison of absolute dose and dose distribution between pencil beam and Monte Carlo algorithms based on actual patient CT scans. Int J Radiat Oncol Biol Phys 2010, 78:955-963.
-
(2010)
Int J Radiat Oncol Biol Phys
, vol.78
, pp. 955-963
-
-
Chen, H.1
Lohr, F.2
Fritz, P.3
-
11
-
-
80053597735
-
Stereotactic radiosurgery-radiotherapy: should Monte Carlo treatment planning be used for all sites?
-
Wilcox E.E., Daskalov G.M., Lincoln H. Stereotactic radiosurgery-radiotherapy: should Monte Carlo treatment planning be used for all sites?. Pract Radiat Oncol 2011, 1:251-260.
-
(2011)
Pract Radiat Oncol
, vol.1
, pp. 251-260
-
-
Wilcox, E.E.1
Daskalov, G.M.2
Lincoln, H.3
-
12
-
-
77950559885
-
Comparison of planned dose distributions calculated by Monte Carlo and Ray-Trace algorithms for the treatment of lung tumors with cyberknife: a preliminary study in 33 patients
-
Wilcox E.E., Daskalov G.M., Lincoln H., Shumway R.C., Kaplan B.M., Colasanto J.M. Comparison of planned dose distributions calculated by Monte Carlo and Ray-Trace algorithms for the treatment of lung tumors with cyberknife: a preliminary study in 33 patients. Int J Radiat Oncol Biol Phys 2010, 77:277-284.
-
(2010)
Int J Radiat Oncol Biol Phys
, vol.77
, pp. 277-284
-
-
Wilcox, E.E.1
Daskalov, G.M.2
Lincoln, H.3
Shumway, R.C.4
Kaplan, B.M.5
Colasanto, J.M.6
-
13
-
-
77953960654
-
Clinical introduction of Monte Carlo treatment planning: a different prescription dose for non-small cell lung cancer according to tumor location and size
-
van der Voort van Zyp N.C., Hoogeman M.S., van de Water S., et al. Clinical introduction of Monte Carlo treatment planning: a different prescription dose for non-small cell lung cancer according to tumor location and size. Radiother Oncol 2010, 96:55-60.
-
(2010)
Radiother Oncol
, vol.96
, pp. 55-60
-
-
van der Voort van Zyp, N.C.1
Hoogeman, M.S.2
van de Water, S.3
-
14
-
-
84865694578
-
Tumor volume-adapted dosing in stereotactic ablative radiotherapy of lung tumors
-
Trakul N., Chang C.N., Harris J., et al. Tumor volume-adapted dosing in stereotactic ablative radiotherapy of lung tumors. Int J Radiat Oncol Biol Phys 2012, 84:231-237.
-
(2012)
Int J Radiat Oncol Biol Phys
, vol.84
, pp. 231-237
-
-
Trakul, N.1
Chang, C.N.2
Harris, J.3
-
15
-
-
27144516385
-
Dose-response in stereotactic irradiation of lung tumors
-
Wulf J., Baier K., Mueller G., Flentje M.P. Dose-response in stereotactic irradiation of lung tumors. Radiother Oncol 2005, 77:83-87.
-
(2005)
Radiother Oncol
, vol.77
, pp. 83-87
-
-
Wulf, J.1
Baier, K.2
Mueller, G.3
Flentje, M.P.4
-
16
-
-
64049110827
-
Dose-response relationship for image-guided stereotactic body radiotherapy of pulmonary tumors: relevance of 4D dose calculation
-
Guckenberger M., Wulf J., Mueller G., et al. Dose-response relationship for image-guided stereotactic body radiotherapy of pulmonary tumors: relevance of 4D dose calculation. Int J Radiat Oncol Biol Phys 2009, 74:47-54.
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.74
, pp. 47-54
-
-
Guckenberger, M.1
Wulf, J.2
Mueller, G.3
-
17
-
-
61349168409
-
Dosimetric evaluation of heterogeneity corrections for RTOG 0236: stereotactic body radiotherapy of inoperable stage I-II non-small-cell lung cancer
-
Xiao Y., Papiez L., Paulus R., et al. Dosimetric evaluation of heterogeneity corrections for RTOG 0236: stereotactic body radiotherapy of inoperable stage I-II non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 2009, 73:1235-1242.
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.73
, pp. 1235-1242
-
-
Xiao, Y.1
Papiez, L.2
Paulus, R.3
-
18
-
-
65649096221
-
The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: implications for tumour coverage
-
Aarup L.R., Nahum A.E., Zacharatou C., et al. The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: implications for tumour coverage. Radiother Oncol 2009, 91:405-414.
-
(2009)
Radiother Oncol
, vol.91
, pp. 405-414
-
-
Aarup, L.R.1
Nahum, A.E.2
Zacharatou, C.3
-
19
-
-
33846882623
-
Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations
-
Knoos T., Wieslander E., Cozzi L., et al. Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations. Phys Med Biol 2006, 51:5785-5807.
-
(2006)
Phys Med Biol
, vol.51
, pp. 5785-5807
-
-
Knoos, T.1
Wieslander, E.2
Cozzi, L.3
-
20
-
-
39049164591
-
Outcomes of risk-adapted fractionated stereotactic radiotherapy for stage I non-small-cell lung cancer
-
Lagerwaard F.J., Haasbeek C.J., Smit E.F., Slotman B.J., Senan S. Outcomes of risk-adapted fractionated stereotactic radiotherapy for stage I non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 2008, 70:685-692.
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.70
, pp. 685-692
-
-
Lagerwaard, F.J.1
Haasbeek, C.J.2
Smit, E.F.3
Slotman, B.J.4
Senan, S.5
-
21
-
-
34547510573
-
Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage I non-small cell lung cancer: updated results of 257 patients in a Japanese multi-institutional study
-
Onishi H., Shirato H., Nagata Y., et al. Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage I non-small cell lung cancer: updated results of 257 patients in a Japanese multi-institutional study. J Thorac Oncol 2007, 2(7 Suppl 3):S94-S100.
-
(2007)
J Thorac Oncol
, vol.2
, Issue.7 SUPPL. 3
-
-
Onishi, H.1
Shirato, H.2
Nagata, Y.3
-
22
-
-
77949520655
-
Stereotactic body radiation therapy for inoperable early stage lung cancer
-
Timmerman R., Paulus R., Galvin J., et al. Stereotactic body radiation therapy for inoperable early stage lung cancer. JAMA 2010, 303:1070-1076.
-
(2010)
JAMA
, vol.303
, pp. 1070-1076
-
-
Timmerman, R.1
Paulus, R.2
Galvin, J.3
-
23
-
-
84872682184
-
CyberKnife with tumor tracking: an effective treatment for high-risk surgical patients with stage I non-small cell lung cancer
-
Chen V.J., Oermann E., Vahdat S., et al. CyberKnife with tumor tracking: an effective treatment for high-risk surgical patients with stage I non-small cell lung cancer. Front Oncol 2012, 2:9.
-
(2012)
Front Oncol
, vol.2
, pp. 9
-
-
Chen, V.J.1
Oermann, E.2
Vahdat, S.3
|