메뉴 건너뛰기




Volumn 96, Issue 1, 2010, Pages 55-60

Clinical introduction of Monte Carlo treatment planning: A different prescription dose for non-small cell lung cancer according to tumor location and size

Author keywords

Dose prescription; Lung cancer; Monte Carlo; Stereotactic radiotherapy

Indexed keywords

ARTICLE; CANCER LOCALIZATION; CANCER SIZE; CYBERKNIFE; DOSIMETRY; LUNG NON SMALL CELL CANCER; MONTE CARLO METHOD; PRESCRIPTION; PRIORITY JOURNAL; RADIATION DOSE; RADIATION FIELD; TREATMENT PLANNING;

EID: 77953960654     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2010.04.009     Document Type: Article
Times cited : (56)

References (25)
  • 1
    • 4844229902 scopus 로고    scopus 로고
    • Stereotactic hypofractionated high-dose irradiation for stage I nonsmall cell lung carcinoma: clinical outcomes in 245 subjects in a Japanese multiinstitutional study
    • Onishi H., Araki T., Shirato H., et al. Stereotactic hypofractionated high-dose irradiation for stage I nonsmall cell lung carcinoma: clinical outcomes in 245 subjects in a Japanese multiinstitutional study. Cancer 101 (2004) 1623-1631
    • (2004) Cancer , vol.101 , pp. 1623-1631
    • Onishi, H.1    Araki, T.2    Shirato, H.3
  • 2
    • 65649110515 scopus 로고    scopus 로고
    • Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: clinical outcome
    • van der Voort van Zyp N.C., Prevost J.B., Hoogeman M.S., et al. Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: clinical outcome. Radiother Oncol 91 (2009) 296-300
    • (2009) Radiother Oncol , vol.91 , pp. 296-300
    • van der Voort van Zyp, N.C.1    Prevost, J.B.2    Hoogeman, M.S.3
  • 3
    • 33748881814 scopus 로고    scopus 로고
    • Dose distributions in SBRT of lung tumors: comparison between two different treatment planning algorithms and Monte-Carlo simulation including breathing motions
    • Lax I., Panettieri V., Wennberg B., et al. Dose distributions in SBRT of lung tumors: comparison between two different treatment planning algorithms and Monte-Carlo simulation including breathing motions. Acta Oncol 45 (2006) 978-988
    • (2006) Acta Oncol , vol.45 , pp. 978-988
    • Lax, I.1    Panettieri, V.2    Wennberg, B.3
  • 5
    • 49749088670 scopus 로고    scopus 로고
    • Developing, evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose
    • Schuring D., and Hurkmans C.W. Developing, evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose. Radiat Oncol 3 (2008) 21
    • (2008) Radiat Oncol , vol.3 , pp. 21
    • Schuring, D.1    Hurkmans, C.W.2
  • 6
    • 65649096221 scopus 로고    scopus 로고
    • The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: implications for tumour coverage
    • Aarup L.R., Nahum A.E., Zacharatou C., et al. The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: implications for tumour coverage. Radiother Oncol 91 (2009) 405-414
    • (2009) Radiother Oncol , vol.91 , pp. 405-414
    • Aarup, L.R.1    Nahum, A.E.2    Zacharatou, C.3
  • 8
    • 34347393495 scopus 로고    scopus 로고
    • Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy
    • Ding G.X., Duggan D.M., Lu B., et al. Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy. Med Phys 34 (2007) 2985-2994
    • (2007) Med Phys , vol.34 , pp. 2985-2994
    • Ding, G.X.1    Duggan, D.M.2    Lu, B.3
  • 9
    • 33748297735 scopus 로고    scopus 로고
    • Accuracy of patient dose calculation for lung IMRT: a comparison of Monte Carlo, convolution/superposition, and pencil beam computations
    • Vanderstraeten B., Reynaert N., Paelinck L., et al. Accuracy of patient dose calculation for lung IMRT: a comparison of Monte Carlo, convolution/superposition, and pencil beam computations. Med Phys 33 (2006) 3149-3158
    • (2006) Med Phys , vol.33 , pp. 3149-3158
    • Vanderstraeten, B.1    Reynaert, N.2    Paelinck, L.3
  • 10
    • 33846882623 scopus 로고    scopus 로고
    • Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations
    • Knoos T., Wieslander E., Cozzi L., et al. Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations. Phys Med Biol 51 (2006) 5785-5807
    • (2006) Phys Med Biol , vol.51 , pp. 5785-5807
    • Knoos, T.1    Wieslander, E.2    Cozzi, L.3
  • 11
    • 33748859087 scopus 로고    scopus 로고
    • Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: marker placement and early results
    • Nuyttens J.J., Prevost J.B., Praag J., et al. Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: marker placement and early results. Acta Oncol 45 (2006) 961-965
    • (2006) Acta Oncol , vol.45 , pp. 961-965
    • Nuyttens, J.J.1    Prevost, J.B.2    Praag, J.3
  • 13
    • 77953960001 scopus 로고    scopus 로고
    • van der Voort van Zyp NC, van der Holt B, van Klaveren RJ, Pattynama P, Maat A, Nuyttens JJ. Stereotactic body radiotherapy using real-time tumor tracking in octogenarians with non-small cell lung cancer. Lung Cancer
    • van der Voort van Zyp NC, van der Holt B, van Klaveren RJ, Pattynama P, Maat A, Nuyttens JJ. Stereotactic body radiotherapy using real-time tumor tracking in octogenarians with non-small cell lung cancer. Lung Cancer.
  • 14
    • 44349155376 scopus 로고    scopus 로고
    • Reducing monitor units for robotic radiosurgery by optimized use of multiple collimators
    • Poll J.J., Hoogeman M.S., Prevost J.B., Nuyttens J.J., Levendag P.C., and Heijmen B.J. Reducing monitor units for robotic radiosurgery by optimized use of multiple collimators. Med Phys 35 (2008) 2294-2299
    • (2008) Med Phys , vol.35 , pp. 2294-2299
    • Poll, J.J.1    Hoogeman, M.S.2    Prevost, J.B.3    Nuyttens, J.J.4    Levendag, P.C.5    Heijmen, B.J.6
  • 15
    • 70350693217 scopus 로고    scopus 로고
    • Accuracy of the Monte Carlo dose calculation algorithm for Cyberknife treatment of small lung lesions [abstract]
    • Hol M., Marijnissen J.P.A., van der Baan P., et al. Accuracy of the Monte Carlo dose calculation algorithm for Cyberknife treatment of small lung lesions [abstract]. Med Phys 35 (2008) 2953
    • (2008) Med Phys , vol.35 , pp. 2953
    • Hol, M.1    Marijnissen, J.P.A.2    van der Baan, P.3
  • 16
    • 0033962673 scopus 로고    scopus 로고
    • Photon beam characterization and modelling for Monte Carlo treatment planning
    • Deng J., Jiang S.B., Kapur A., Li J., Pawlicki T., and Ma C.M. Photon beam characterization and modelling for Monte Carlo treatment planning. Phys Med Biol 45 (2000) 411-427
    • (2000) Phys Med Biol , vol.45 , pp. 411-427
    • Deng, J.1    Jiang, S.B.2    Kapur, A.3    Li, J.4    Pawlicki, T.5    Ma, C.M.6
  • 17
    • 0035014154 scopus 로고    scopus 로고
    • Derivation of electron and photon energy spectra from electron beam central axis depth dose curves
    • Deng J., Jiang S.B., Pawlicki T., Li J., and Ma C.M. Derivation of electron and photon energy spectra from electron beam central axis depth dose curves. Phys Med Biol 46 (2001) 1429-1449
    • (2001) Phys Med Biol , vol.46 , pp. 1429-1449
    • Deng, J.1    Jiang, S.B.2    Pawlicki, T.3    Li, J.4    Ma, C.M.5
  • 18
    • 0033977586 scopus 로고    scopus 로고
    • Electron beam modeling and commissioning for Monte Carlo treatment planning
    • Jiang S.B., Kapur A., and Ma C.M. Electron beam modeling and commissioning for Monte Carlo treatment planning. Med Phys 27 (2000) 180-191
    • (2000) Med Phys , vol.27 , pp. 180-191
    • Jiang, S.B.1    Kapur, A.2    Ma, C.M.3
  • 19
    • 44649143846 scopus 로고    scopus 로고
    • Implementation of Monte Carlo dose calculation for CyberKnife treatment planning
    • Ma C.-M., Li J.S., Deng J., and Fan J. Implementation of Monte Carlo dose calculation for CyberKnife treatment planning. J Phys Conf Ser 102 (2008) 012016
    • (2008) J Phys Conf Ser , vol.102 , pp. 012016
    • Ma, C.-M.1    Li, J.S.2    Deng, J.3    Fan, J.4
  • 20
    • 36649020653 scopus 로고    scopus 로고
    • Report of the AAPM Task Group No. 105: issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
    • Chetty I.J., Curran B., Cygler J.E., et al. Report of the AAPM Task Group No. 105: issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med Phys 34 (2007) 4818-4853
    • (2007) Med Phys , vol.34 , pp. 4818-4853
    • Chetty, I.J.1    Curran, B.2    Cygler, J.E.3
  • 21
    • 34548457234 scopus 로고    scopus 로고
    • The IASLC Lung Cancer Staging Project: proposals for the revision of the TNM stage groupings in the forthcoming (seventh) edition of the TNM classification of malignant tumours
    • Goldstraw P., Crowley J., Chansky K., et al. The IASLC Lung Cancer Staging Project: proposals for the revision of the TNM stage groupings in the forthcoming (seventh) edition of the TNM classification of malignant tumours. J Thorac Oncol 2 (2007) 706-714
    • (2007) J Thorac Oncol , vol.2 , pp. 706-714
    • Goldstraw, P.1    Crowley, J.2    Chansky, K.3
  • 22
    • 60649101265 scopus 로고    scopus 로고
    • Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study
    • Hurkmans C.W., Cuijpers J.P., Lagerwaard F.J., et al. Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study. Radiat Oncol 4 (2009) 1
    • (2009) Radiat Oncol , vol.4 , pp. 1
    • Hurkmans, C.W.1    Cuijpers, J.P.2    Lagerwaard, F.J.3
  • 23
    • 61349168409 scopus 로고    scopus 로고
    • Dosimetric evaluation of heterogeneity corrections for RTOG 0236: stereotactic body radiotherapy of inoperable stage I-II non-small-cell lung cancer
    • Xiao Y., Papiez L., Paulus R., et al. Dosimetric evaluation of heterogeneity corrections for RTOG 0236: stereotactic body radiotherapy of inoperable stage I-II non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 73 (2009) 1235-1242
    • (2009) Int J Radiat Oncol Biol Phys , vol.73 , pp. 1235-1242
    • Xiao, Y.1    Papiez, L.2    Paulus, R.3
  • 24
    • 33748851899 scopus 로고    scopus 로고
    • Factors important for efficacy of stereotactic body radiotherapy of medically inoperable stage I lung cancer. A retrospective analysis of patients treated in the Nordic countries
    • Baumann P., Nyman J., Lax I., et al. Factors important for efficacy of stereotactic body radiotherapy of medically inoperable stage I lung cancer. A retrospective analysis of patients treated in the Nordic countries. Acta Oncol 45 (2006) 787-795
    • (2006) Acta Oncol , vol.45 , pp. 787-795
    • Baumann, P.1    Nyman, J.2    Lax, I.3
  • 25
    • 36749032206 scopus 로고    scopus 로고
    • A phase II study on stereotactic body radiotherapy for stage I non-small cell lung cancer
    • Koto M., Takai Y., Ogawa Y., et al. A phase II study on stereotactic body radiotherapy for stage I non-small cell lung cancer. Radiother Oncol 85 (2007) 429-434
    • (2007) Radiother Oncol , vol.85 , pp. 429-434
    • Koto, M.1    Takai, Y.2    Ogawa, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.