메뉴 건너뛰기




Volumn 28, Issue 3, 2011, Pages 213-220

Assessment of the risk of perforation of the mandibular canal by implant drill using density and thickness parameters

Author keywords

damage inferior alveolar nerve; implant drills

Indexed keywords

ADULT; AGE; AGED; ARTICLE; BONE DENSITY; COMPUTER ASSISTED TOMOGRAPHY; CONE BEAM COMPUTED TOMOGRAPHY; EQUIPMENT; FEMALE; HISTOLOGY; HUMAN; JAW DISEASE; MALE; MANDIBLE; MANDIBULAR NERVE; MIDDLE AGED; MOLAR TOOTH; MULTIDETECTOR COMPUTED TOMOGRAPHY; PARESTHESIA; PEROPERATIVE COMPLICATION; PHYSIOLOGY; PREMOLAR TOOTH; RADIOGRAPHY; RISK ASSESSMENT; SEX DIFFERENCE; TOOTH ARCH; TOOTH IMPLANTATION; TRIGEMINAL NERVE INJURY; YOUNG ADULT;

EID: 84884211320     PISSN: 07340664     EISSN: 17412358     Source Type: Journal    
DOI: 10.1111/j.1741-2358.2009.00362.x     Document Type: Article
Times cited : (25)

References (63)
  • 1
    • 26844501676 scopus 로고    scopus 로고
    • Implant reversible complications: Classification and treatments
    • Park SH, Wang HL,. Implant reversible complications: classification and treatments. Implant Dent 2005; 14: 211-220.
    • (2005) Implant Dent , vol.14 , pp. 211-220
    • Park, S.H.1    Wang, H.L.2
  • 3
    • 21344445524 scopus 로고    scopus 로고
    • Critical hemorrhage in the floor of the mouth during implant placement in the first mandibular premolar position: A case report
    • DOI 10.1097/01.id.0000165028.89434.99
    • Kalpidis CD, Konstantinidis AB,. Critical hemorrhage in the floor of the mouth during implant placement in the first mandibular premolar position: a case report. Implant Dent 2005; 14: 117-124. (Pubitemid 40905323)
    • (2005) Implant Dentistry , vol.14 , Issue.2 , pp. 117-124
    • Kalpidis, C.D.1    Konstantinidis, A.B.2
  • 4
    • 34249815545 scopus 로고    scopus 로고
    • Cortical bone thickness in dentate and edentulous human cadavers
    • Katranji A, Misch K, Wang HL,. Cortical bone thickness in dentate and edentulous human cadavers. J Periodontol 2007; 78: 874-878.
    • (2007) J Periodontol , vol.78 , pp. 874-878
    • Katranji, A.1    Misch, K.2    Wang, H.L.3
  • 6
    • 0043261428 scopus 로고    scopus 로고
    • Management of the implant periapical lesions: A case report
    • Oh TJ, Joogkyo Y, Wang HL,. Management of the implant periapical lesions: a case report. Implant Dent 2003; 12: 41-46.
    • (2003) Implant Dent , vol.12 , pp. 41-46
    • Oh, T.J.1    Joogkyo, Y.2    Wang, H.L.3
  • 7
    • 0035347079 scopus 로고    scopus 로고
    • Development and Treatment of Retrograde Peri-implantitis Involving a Site with a History of Failed Endodontic and Apicoectomy Procedures: A Series of Reports
    • Ayangco L, Sheridan PJ,. Development and treatment of retrograde periimplantittis involving a site with a history of failed endodontic and apicectomy procedures: a series of reports. Int J Oral Maxillofac Implants 2001; 16: 412-417. (Pubitemid 33673144)
    • (2001) International Journal of Oral and Maxillofacial Implants , vol.16 , Issue.3 , pp. 412-417
    • Ayangco, L.1    Sheridan, P.J.2
  • 10
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit
    • Ericksson AR, Albrektsson T,. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent 1983; 50: 101-107.
    • (1983) J Prosthet Dent , vol.50 , pp. 101-107
    • Ericksson, A.R.1    Albrektsson, T.2
  • 13
    • 0036788376 scopus 로고    scopus 로고
    • Heat generation during implant drilling: The significance of motor speed
    • Sharaway M, Misch CE, Tehemar S, et al. Heat generation during implant drilling: the significance of motor speed. J Oral Maxillofac Surg 2002; 60: 1160-1169.
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 1160-1169
    • Sharaway, M.1    Misch, C.E.2    Tehemar, S.3
  • 14
    • 0345227294 scopus 로고    scopus 로고
    • An infected jawbone site compromising successful osseointegration
    • DOI 10.1046/j.0906-6713.2002.03311.x
    • Quirynen M, Gijbels F, Jacobs R,. An infected jawbone site compromising successful osseointegration. Periodontology 2000 2003; 33: 129-144. (Pubitemid 37487559)
    • (2003) Periodontology 2000 , vol.33 , pp. 129-144
    • Quiryen, M.1    Gijbels, F.2    Jacobs, R.3
  • 15
    • 33646502118 scopus 로고    scopus 로고
    • Significance of primary stability for osseointegration of dental implants
    • DOI 10.1111/j.1600-0501.2005.01201.x
    • Lioubavina-Hack N, Lang NP, Karring T,. Significance of primary stability for osseointegration of dental implants. Clin Oral Implants Res 2006; 17: 244-250. (Pubitemid 43709390)
    • (2006) Clinical Oral Implants Research , vol.17 , Issue.3 , pp. 244-250
    • Lioubavina-Hack, N.1    Lang, N.P.2    Karring, T.3
  • 16
    • 0038284316 scopus 로고    scopus 로고
    • The jumping distance revisited: An experimental study in the dog
    • DOI 10.1034/j.1600-0501.2003.140105.x
    • Boticelli D, Berglundh T, Lindhe J, et al. The jumping distance revisited: An experimental study in the dog. Clin Oral Implants Res 2003; 14: 35-42. (Pubitemid 37490588)
    • (2003) Clinical Oral Implants Research , vol.14 , Issue.1 , pp. 35-42
    • Botticelli, D.1    Berglundh, T.2    Buser, D.3    Lindhe, J.4
  • 20
    • 30144434331 scopus 로고    scopus 로고
    • Significance of osteoporosis in craniomaxillofacial surgery: A review of the literature
    • DOI 10.1007/s00198-005-1967-4
    • Hohlweg-Majert B, Schmelzeisen R, Schneider E, et al. Significance of osteoporosis in craniomaxillofacial surgery: a review of the literature. Osteoporos Int 2006; 17: 167-179. (Pubitemid 43053579)
    • (2006) Osteoporosis International , vol.17 , Issue.2 , pp. 167-179
    • Hohlweg-Majert, B.1    Schmelzeisen, R.2    Pfeiffer, B.M.3    Schneider, E.4
  • 21
    • 0026281398 scopus 로고
    • Management of mandibular fractures in patients with endosseous implants
    • Tolman DE, Keller EE,. Management of mandibular fractures in patients with endosseous implants. Int J Oral Maxillofac Implants 1991; 6: 427-436.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 427-436
    • Tolman, D.E.1    Keller, E.E.2
  • 22
    • 7244239093 scopus 로고    scopus 로고
    • Injury to the inferior alveolar nerve during implant placement: A formula for protection of the patient and clinician
    • Worthington P,. Injury to the inferior alveolar nerve during implant placement: a formula for protection of the patient and clinician. Int J Oral Maxillofac Implants 2004; 19: 731-734. (Pubitemid 39430462)
    • (2004) International Journal of Oral and Maxillofacial Implants , vol.19 , Issue.5 , pp. 731-734
    • Worthington, P.1
  • 23
    • 0026931182 scopus 로고
    • Altered sensations following mandibular implant surgery: A retrospective study
    • Ellies LG,. Altered sensations following mandibular implant surgery: a retrospective study. J Prosthet Dent 1992; 68: 664-671.
    • (1992) J Prosthet Dent , vol.68 , pp. 664-671
    • Ellies, L.G.1
  • 24
    • 0027872438 scopus 로고
    • The prevalence of altered sensation association with implant surgery
    • Ellies LG, Hawker PB,. The prevalence of altered sensation association with implant surgery. Int J Oral Maxillofac Implants 1993; 8: 674-679.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 674-679
    • Ellies, L.G.1    Hawker, P.B.2
  • 25
    • 0030750912 scopus 로고    scopus 로고
    • Patients' perception of sensory disturbances of the mental nerve before and after implant surgery: A prospective study of 110 patients
    • DOI 10.1016/S0266-4356(97)90043-7
    • Wismeijer D, Van Waas MAJ, Vermeeren JUF, Kalk W,. Patients' perception of sensory disturbance of the mental nerve before and after implant surgery: a prospective study of 110 patients. Br J Oral Maxillofac Surg 1997; 35: 254-259. (Pubitemid 27380057)
    • (1997) British Journal of Oral and Maxillofacial Surgery , vol.35 , Issue.4 , pp. 254-259
    • Wismeijer, D.1    Van Waas, M.A.J.2    Vermeeren, J.I.J.F.3    Kalk, W.4
  • 26
    • 0032710022 scopus 로고    scopus 로고
    • The incidence of altered sensation of the mental nerve after mandibular implant placement
    • Bartling R, Freeman K, Krayt RA,. The incidence of altered sensation of the mental nerve after mandibular implant placement. J Oral Maxillofac Surg 1999; 57: 1408-1410.
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 1408-1410
    • Bartling, R.1    Freeman, K.2    Krayt, R.A.3
  • 27
    • 0025688549 scopus 로고
    • Predictable mandibular nerve location - A clinical zone of safety
    • Misch CE, Crawford EA,. Predictable mandibular nerve location - a clinical zone of safety. Int J Oral Implantol 1990; 7: 37-40.
    • (1990) Int J Oral Implantol , vol.7 , pp. 37-40
    • Misch, C.E.1    Crawford, E.A.2
  • 28
    • 0026112449 scopus 로고
    • A comparison of panoramic radiography with computed tomography in the planning of implant surgery
    • Tal H, Moses O,. A comparison of panoramic radiography with computed tomography in the planning of implant surgery. Dentomaxillofac Radiol 1991; 20: 40-42.
    • (1991) Dentomaxillofac Radiol , vol.20 , pp. 40-42
    • Tal, H.1    Moses, O.2
  • 30
    • 0031894044 scopus 로고    scopus 로고
    • Inflammatory disease of the jaw: Appearance of reformatted CT scans
    • Abrahams JJ, Berger SB,. Inflammatory disease of the jaw: appearance on reformatted CT scans. Am J Roentgenology 1998; 170: 1085-1091. (Pubitemid 28172904)
    • (1998) American Journal of Roentgenology , vol.170 , Issue.4 , pp. 1085-1091
    • Abrahams, J.J.1    Berger, S.B.2
  • 31
    • 0016220056 scopus 로고
    • Studies of residual ridge resorption: Part 1: Use of panoramic radiographs for evaluation and classification of mandibular resorption
    • Wical KF, Swoope CC,. Studies of residual ridge resorption: part 1: Use of panoramic radiographs for evaluation and classification of mandibular resorption. J Prosthet Dent 1974; 32: 7-12.
    • (1974) J Prosthet Dent , vol.32 , pp. 7-12
    • Wical, K.F.1    Swoope, C.C.2
  • 32
    • 0027355488 scopus 로고
    • Treatment planning, placement of implants in the posterior maxillae: Report of 732 consecutive Nobelpharma implants
    • Bahat O,. Treatment planning, placement of implants in the posterior maxillae: report of 732 consecutive Nobelpharma implants. Int J Oral Maxillofac Implants 1993; 8: 151-161.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 151-161
    • Bahat, O.1
  • 33
    • 0039784995 scopus 로고
    • A comparison of the accuracy of periapical, panoramic, and computerized tomographic radiographs in locating the mandibular canal
    • Sonick M, Abrahams MD, Faiella RA,. A comparison of the accuracy of periapical, panoramic, and computerized tomographic radiographs in locating the mandibular canal. Int J Oral Maxillofac Implants 1994; 9: 455-460.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 455-460
    • Sonick, M.1    Abrahams, M.D.2    Faiella, R.A.3
  • 34
    • 0023905804 scopus 로고    scopus 로고
    • Quantitative CT for determination of bone mineral density: A review
    • Cann CE,. Quantitative CT for determination of bone mineral density: a review. Radiology 1998; 166: 509-522.
    • (1998) Radiology , vol.166 , pp. 509-522
    • Cann, C.E.1
  • 36
    • 0025396337 scopus 로고
    • A precise radiographic method to determine the location of the inferior alveolar canal in the posterior edentulous mandible: Implications for dental implants. Part 2: Clinical application
    • Stella JP, Tharanon W,. A precise radiographic method to determine the location of the inferior alveolar canal in the posterior edentulous mandible: implications for dental implants. Part 2: Clinical application. Int J Oral Maxillofac Implants 1990; 5: 23-30.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 23-30
    • Stella, J.P.1    Tharanon, W.2
  • 37
    • 0023110319 scopus 로고
    • Dental radiography: Efficacy in the assessment of intraosseous lesions of the face and jaws in asymptomatic patients
    • Zeichner SJ, Ruttiman UE, Webber RL,. Dental radiography: Efficacy in the assessment of intraosseous lesions of the face and jaws in the asymptomatic patients. Radiology 1987; 162: 691-695. (Pubitemid 17019197)
    • (1987) Radiology , vol.162 , Issue.3 , pp. 691-695
    • Zeichner, S.J.1    Ruttimannn, U.E.2    Webber, R.L.3
  • 38
    • 0037608932 scopus 로고    scopus 로고
    • Advanced imaging: Magnetic resonance imaging in implant dentistry - A review
    • DOI 10.1034/j.1600-0501.2003.140103.x
    • Gray CF, Redpath TW, Smith FW, et al. Advanced imaging: magnetic resonance imaging in implant dentistry. Clin Oral Implants Res 2003; 14: 18-27. (Pubitemid 37490586)
    • (2003) Clinical Oral Implants Research , vol.14 , Issue.1 , pp. 18-27
    • Gray, C.F.1    Redpath, T.W.2    Smith, F.W.3    Staff, R.T.4
  • 39
    • 0025617788 scopus 로고
    • Density of bone: Effect on treatment plans, surgical approach, healing, and progressive loading
    • Misch CE,. Density of bone: effect on treatment plans, surgical approach, healing, and progressive loading. Int J Oral Implant 1990; 6: 23-31.
    • (1990) Int J Oral Implant , vol.6 , pp. 23-31
    • Misch, C.E.1
  • 43
    • 0023358833 scopus 로고
    • Computed tomography. Part 1. Preoperative assessment of the mandible for endosseous implant surgery
    • Schwarz MS, Rothman SL, Rhodes ML, Chafetz N,. Computed tomography. Part 1. Preoperative assessment of the mandible for endosseous implant surgery. Int J Oral Maxillofac Implants 1987; 2: 137-141.
    • (1987) Int J Oral Maxillofac Implants , vol.2 , pp. 137-141
    • Schwarz, M.S.1    Rothman, S.L.2    Rhodes, M.L.3    Chafetz, N.4
  • 44
    • 0040362764 scopus 로고
    • Bone character: Second vital implant criterion
    • Misch CE,. Bone character: second vital implant criterion. Dent Today 1988; 7: 39-40.
    • (1988) Dent Today , vol.7 , pp. 39-40
    • Misch, C.E.1
  • 46
    • 0000714284 scopus 로고
    • Temperature changes during high speed drilling on bone
    • Rafel SS,. Temperature changes during high speed drilling on bone. J Oral Surg Anesth Hosp Dent Serv 1962; 20: 475-477.
    • (1962) J Oral Surg Anesth Hosp Dent Serv , vol.20 , pp. 475-477
    • Rafel, S.S.1
  • 47
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • Matthewes J, Hirsch C,. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg 1972; 45: 297-308.
    • (1972) J Bone Joint Surg , vol.45 , pp. 297-308
    • Matthewes, J.1    Hirsch, C.2
  • 48
    • 0029683215 scopus 로고
    • The effect of speed, pressure, and time on bone temperature during the drilling of implant sites
    • Brisntan DL,. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants 1976; 11: 35-37.
    • (1976) Int J Oral Maxillofac Implants , vol.11 , pp. 35-37
    • Brisntan, D.L.1
  • 49
    • 0025060760 scopus 로고
    • The effect of diameter and length of hydroxylapatite-coated dental implants on ultimate pullout force in dog alveolar bone
    • Block MS, Delgado A, Fontenot MG,. The effect of diameter and length of hydroxilapatite-coated dental implants on ultimate pullout force in dog alveolar bone. J Oral Maxillofac Surg 1990; 48: 174-178. (Pubitemid 20053176)
    • (1990) Journal of Oral and Maxillofacial Surgery , vol.48 , Issue.2 , pp. 174-178
    • Block, M.S.1    Delgado, A.2    Fontenot, M.G.3
  • 51
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography)
    • Houndsfield GN,. Computerized transverse axial scanning (tomography). Br J Radiol 1973; 46: 1016-1022.
    • (1973) Br J Radiol , vol.46 , pp. 1016-1022
    • Houndsfield, G.N.1
  • 52
    • 0013864447 scopus 로고
    • Factors affecting the determination of the physical properties of femoral cortical bone
    • Sedlin ED, Hirsch C,. Factors affecting the determination of the physical properties of femoral cortical bone. Acta Orthop Scand 1966; 37: 29-48.
    • (1966) Acta Orthop Scand , vol.37 , pp. 29-48
    • Sedlin, E.D.1    Hirsch, C.2
  • 54
    • 0035261160 scopus 로고    scopus 로고
    • Bone classification: An objective scale of bone density using the computerized tomography scan
    • Norton MR, Gamble C,. Bone classification: an objective scale of bone density using the computerized tomography scan. Clin Oral Implants Res 2001; 12: 79-84. (Pubitemid 33723216)
    • (2001) Clinical Oral Implants Research , vol.12 , Issue.1 , pp. 79-84
    • Norton, M.R.1    Gamble, C.2
  • 55
    • 0017642925 scopus 로고
    • Investigation of variable factors in drilling bone
    • Hobkirk J, Rusiniak K,. Investigation of variable factors in drilling bone. J Oral Surg 1977; 35: 968-973. (Pubitemid 8242795)
    • (1977) Journal of Oral Surgery , vol.35 , Issue.12 , pp. 968-973
    • Hobkirk, J.A.1    Rusiniak, K.2
  • 56
    • 17844379203 scopus 로고    scopus 로고
    • Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: A clinical study
    • Ikumi N, Tsutsumi S,. Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: a clinical study. Int J Oral Maxillofac Implants 2005; 20: 253-260. (Pubitemid 40592213)
    • (2005) International Journal of Oral and Maxillofacial Implants , vol.20 , Issue.2 , pp. 253-260
    • Ikumi, N.1    Tsutsumi, S.2
  • 57
    • 0033067941 scopus 로고    scopus 로고
    • Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement
    • DOI 10.1016/S0278-2391(99)90437-8
    • Misch CE, Qu Z, Bidez MW,. Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement. J Oral Maxillofac Surg 1999; 57: 700-706. (Pubitemid 29269607)
    • (1999) Journal of Oral and Maxillofacial Surgery , vol.57 , Issue.6 , pp. 700-706
    • Misch, C.E.1    Qu, Z.2    Bidez, M.W.3
  • 58
    • 0028701318 scopus 로고
    • Second stage failures related to bone quality in patients receiving endosseous dental implants: DICRG Interim Report No. 7. Dental Implant Clinical Research Group
    • Truhlar RS, Morris HF, Ochi S, et al. Second stage failures related to bone quality in patients receiving endosseous dental implants: DICRG Interim Report No. 7. Dental Implant Clinical Research Group. Implant Dent 1994; 3: 252-255.
    • (1994) Implant Dent , vol.3 , pp. 252-255
    • Truhlar, R.S.1    Morris, H.F.2    Ochi, S.3
  • 59
    • 0027352853 scopus 로고
    • Influences of drill cooling and bone structure on primary implant fixation
    • Haider R, Wadzek G, Plenk H Jr,. Influences of drill cooling and bone structure on primary implant fixation. Int J Oral Maxillofac Implants 1993; 8: 83-91.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 83-91
    • Haider, R.1    Wadzek, G.2    Plenk, Jr.H.3
  • 62
    • 0035553213 scopus 로고    scopus 로고
    • Alternative to the inferior alveolar nerve block anesthesia when placing mandibular dental implants posterior to the mental foramen
    • Heller AA, Shankland WE II,. Alternative to the inferior alveolar nerve block anesthesia when placing mandibular dental implants posterior to the mental foramen. J Oral Implantol 2001; 27: 127-133.
    • (2001) J Oral Implantol , vol.27 , pp. 127-133
    • Heller, A.A.1    Shankland, I.I.W.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.