메뉴 건너뛰기




Volumn 31, Issue 9, 2013, Pages 1847-1852

Determination of central blood pressure by a noninvasive method (brachial blood pressure and QKD interval): A noninvasive validation

Author keywords

Central blood pressure; Head up tilt; Holter recording; QKD interval; SphygmoCor

Indexed keywords

ADULT; AGED; ARTICLE; ASCENDING AORTA; BLOOD PRESSURE; BLOOD PRESSURE MEASUREMENT; BODY HEIGHT; COMPARATIVE STUDY; CONTROLLED STUDY; FEMALE; HEART RATE; HUMAN; MAJOR CLINICAL STUDY; MALE; NON INVASIVE PROCEDURE; PRIORITY JOURNAL; SPHYGMOMANOMETER;

EID: 84884206537     PISSN: 02636352     EISSN: 14735598     Source Type: Journal    
DOI: 10.1097/HJH.0b013e328362bab9     Document Type: Article
Times cited : (9)

References (32)
  • 1
    • 77954814318 scopus 로고    scopus 로고
    • Prediction of cardiovascular events and all-cause mortality with Central haemodynamics: A systematic review and meta-analysis
    • Vlachopoulos C, Aznaouridis K, O'Rourke MF, Safar ME, Baou K, Stefanadis C. Prediction of cardiovascular events and all-cause mortality with central haemodynamics: a systematic review and meta-analysis. Eur Heart J 2010; 31:1865-1871.
    • (2010) Eur Heart J , vol.31 , pp. 1865-1871
    • Vlachopoulos, C.1    Aznaouridis, K.2    O'Rourke, M.F.3    Safar, M.E.4    Baou, K.5    Stefanadis, C.6
  • 3
    • 34250875202 scopus 로고    scopus 로고
    • Central pressure more strongly relates to vascular disease and outcome than does brachial pressure: The strong heart study
    • Roman MJ, Devereux RB, Kizer J.R., Lee ET, Galloway JM, Ali T, et al. Central pressure more strongly relates to vascular disease and outcome than does brachial pressure: the Strong Heart Study. Hypertension 2007; 50:197-203.
    • (2007) Hypertension , vol.50 , pp. 197-203
    • Roman, M.J.1    Devereux, R.B.2    Kizer, J.R.3    Lee, E.T.4    Galloway, J.M.5    Ali, T.6
  • 4
    • 33645518432 scopus 로고    scopus 로고
    • Differential impact of blood pressure-lowering drugs on Central aortic pressure and clinical outcomes: Principal results of the conduit artery function evaluation (CAFE) study
    • Williams B, Lacy PS, Thom S.M., Cruickshank K., Stanton A, Collier D, et al Differential impact of blood pressure-lowering drugs on central aortic pressure and clinical outcomes: principal results of the Conduit Artery Function Evaluation (CAFE) study. Circulation 2006; 113:1213-1225.
    • (2006) Circulation , vol.113 , pp. 1213-1225
    • Williams, B.1    Lacy, P.S.2    Thom, S.M.3    Cruickshank, K.4    Stanton, A.5    Collier, D.6
  • 5
    • 76749131590 scopus 로고    scopus 로고
    • Cross-sectional characterization of all classes of antihypertensives in terms of Central blood pressure in Japanese hypertensive patients
    • Miyashita H, Aizawa A, Hashimoto J., Hirooka Y, Imai Y, Kawano Y., et al. Cross-sectional characterization of all classes of antihypertensives in terms of central blood pressure in Japanese hypertensive patients. Am J Hypertens 2010; 23:260-268.
    • (2010) Am J Hypertens , vol.23 , pp. 260-268
    • Miyashita, H.1    Aizawa, A.2    Hashimoto, J.3    Hirooka, Y.4    Imai, Y.5    Kawano, Y.6
  • 7
    • 0027460281 scopus 로고
    • An analysis of the relationship between Central aortic and peripheral upper limb pressure waves in man
    • Karamanoglu M, O'Rourke MF, Avolio AP, Kelly RP. An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. Eur Heart J 1993; 14:160-167.
    • (1993) Eur Heart J , vol.14 , pp. 160-167
    • Karamanoglu, M.1    O'Rourke, M.F.2    Avolio, A.P.3    Kelly, R.P.4
  • 8
    • 0030334214 scopus 로고    scopus 로고
    • Estimation of ascending aortic pressure from radial arterial pressure using a generalised transfer function
    • Takazawa K, O'Rourke MF, Fujita M, Tanaka N., Takeda K, Kurosu F, et al. Estimation of ascending aortic pressure from radial arterial pressure using a generalised transfer function. Zeitschrift fur Kardiologie 1996; 85 (SUPPL. 3):137-139.
    • (1996) Zeitschrift Fur Kardiologie , vol.85 , Issue.SUPPL. 3 , pp. 137-139
    • Takazawa, K.1    O'Rourke, M.F.2    Fujita, M.3    Tanaka, N.4    Takeda, K.5    Kurosu, F.6
  • 9
    • 84870257287 scopus 로고    scopus 로고
    • Clinical assessment of Central blood pressure
    • Miyashita H. Clinical assessment of central blood pressure. Curr Hypertens Rev 2012; 8:80-90.
    • (2012) Curr Hypertens Rev , vol.8 , pp. 80-90
    • Miyashita, H.1
  • 11
    • 77957284980 scopus 로고    scopus 로고
    • Invasive validation of a new oscillometric device (Arteriograph) for measuring augmentation index, Central blood pressure and aortic pulse wave velocity
    • Horvath IG, Nemwth A, Lenkey Z., Alessandri N, Tufano F, Kis P., et al. Invasive validation of a new oscillometric device (Arteriograph) for measuring augmentation index, central blood pressure and aortic pulse wave velocity. J Hypertens 2010; 28:2068-2675.
    • (2010) J Hypertens , vol.28 , pp. 2068-2675
    • Horvath, I.G.1    Nemwth, A.2    Lenkey, Z.3    Alessandri, N.4    Tufano, F.5    Kis, P.6
  • 12
    • 83155172358 scopus 로고    scopus 로고
    • Validation of a brachial cuff-based method for estimating Central systolic blood pressure
    • Weber T, Wassertheurer S, Rammer M., Maurer E, Hametner B, Mayer C.C., et al. Validation of a brachial cuff-based method for estimating central systolic blood pressure. Hypertension 2011; 58:825-832.
    • (2011) Hypertension , vol.58 , pp. 825-832
    • Weber, T.1    Wassertheurer, S.2    Rammer, M.3    Maurer, E.4    Hametner, B.5    Mayer, C.C.6
  • 13
    • 0026496365 scopus 로고
    • Noninvasive determination of aortic input impedance and external left ventricular power output: A validation and repeatability study of a new technique
    • Kelly R, Fitchett D. Noninvasive determination of aortic input impedance and external left ventricular power output: a validation and repeatability study of a new technique. J Am Coll Cardiol 1992; 20:952-963.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 952-963
    • Kelly, R.1    Fitchett, D.2
  • 14
    • 0035724737 scopus 로고    scopus 로고
    • Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform
    • Pauca AL, O'Rourke MF, Kon ND. Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform. Hypertension 2001; 38:932-937.
    • (2001) Hypertension , vol.38 , pp. 932-937
    • Pauca, A.L.1    O'Rourke, M.F.2    Kon, N.D.3
  • 15
    • 79951603923 scopus 로고    scopus 로고
    • Development and validation of a novel method to derive Central aortic systolic pressure from the radial pressure waveform using an N-point moving average method
    • Williams B, Lacy PS, Yan P, Hwee C.N., Liang C., Ting CM. Development and validation of a novel method to derive central aortic systolic pressure from the radial pressure waveform using an N-point moving average method. J Am Coll Cardiol 2011; 57:951-961.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 951-961
    • Williams, B.1    Lacy, P.S.2    Yan, P.3    Hwee, C.N.4    Liang, C.5    Ting, C.M.6
  • 16
    • 85084931884 scopus 로고    scopus 로고
    • Evaluation of the vicorder, a novel cuff-based device for the noninvasive estimation of Central blood pressure
    • Pucci G, Cheriyan J, Hubsch A., Hickson SS, Gajendragadkar PR, Watson T, et al Evaluation of the Vicorder, a novel cuff-based device for the noninvasive estimation of central blood pressure. J Hypertens 2012.
    • (2012) J Hypertens
    • Pucci, G.1    Cheriyan, J.2    Hubsch, A.3    Hickson, S.S.4    Gajendragadkar, P.R.5    Watson, T.6
  • 17
    • 84863816080 scopus 로고    scopus 로고
    • Determination of Central blood pressure by a noninvasive method (brachial BP and QKD interval)
    • Cremer A, Butlin M, Codjo L., Coulon P, Ranouil X, Joret C., et al. Determination of central blood pressure by a noninvasive method (brachial BP and QKD interval). J Hypertens 2012; 30:1533-1539.
    • (2012) J Hypertens , vol.30 , pp. 1533-1539
    • Cremer, A.1    Butlin, M.2    Codjo, L.3    Coulon, P.4    Ranouil, X.5    Joret, C.6
  • 18
    • 0028202475 scopus 로고
    • Assessment of arterial distensibility by monitoring the timing of korotkoff sounds
    • Gosse P, Guillo P, Ascher G., Clementy J. Assessment of arterial distensibility by monitoring the timing of Korotkoff sounds. Am J Hypertens 1994; 7:228-233.
    • (1994) Am J Hypertens , vol.7 , pp. 228-233
    • Gosse, P.1    Guillo, P.2    Ascher, G.3    Clementy, J.4
  • 19
    • 17044400614 scopus 로고    scopus 로고
    • Arterial stiffness evaluated by measurement of the QKD interval is an independent predictor of cardiovascular events
    • Gosse P, Lassere R, Minifie C., Lemetayer C, Clementy C. Arterial stiffness evaluated by measurement of the QKD interval is an independent predictor of cardiovascular events. Am J Hypertens 2005; 18 (4 Pt 1):470-476.
    • (2005) Am J Hypertens , vol.18 , Issue.4 PART 1 , pp. 470-476
    • Gosse, P.1    Lassere, R.2    Minifie, C.3    Lemetayer, C.4    Clementy, C.5
  • 20
    • 34547473157 scopus 로고    scopus 로고
    • Can ambulatory blood-pressure monitoring provide reliable indices of arterial stiffness?
    • Gosse P, Papioanou G, Coulon P., Reuter S, Lemetayer P, Safar M. Can ambulatory blood-pressure monitoring provide reliable indices of arterial stiffness? Am J Hypertens 2007; 20:831-838.
    • (2007) Am J Hypertens , vol.20 , pp. 831-838
    • Gosse, P.1    Papioanou, G.2    Coulon, P.3    Reuter, S.4    Lemetayer, P.5    Safar, M.6
  • 21
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: Recommendations of the European society of hypertension
    • O'Brien E., Waeber B, Parati G., Staessen J, Myers MG. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ 2001; 322:531-536.
    • (2001) BMJ , vol.322 , pp. 531-536
    • O'Brien, E.1    Waeber, B.2    Parati, G.3    Staessen, J.4    Myers, M.G.5
  • 22
    • 0033946588 scopus 로고    scopus 로고
    • Formula and nomogram for the sphygmomanometric calculation of the mean arterial pressure
    • Meaney E, Alva F, Moguel R., Meaney A, Alva J, Webel R. Formula and nomogram for the sphygmomanometric calculation of the mean arterial pressure. Heart 2000; 84:64.
    • (2000) Heart , vol.84 , pp. 64
    • Meaney, E.1    Alva, F.2    Moguel, R.3    Meaney, A.4    Alva, J.5    Webel, R.6
  • 23
    • 33746112932 scopus 로고    scopus 로고
    • Validation of the microlife BPA100 plus device for self-home blood pressure measurement according to the international protocol
    • Stergiou GS, Giovas PP, Neofytou M.S., Adamopoulos DN. Validation of the Microlife BPA100 Plus device for self-home blood pressure measurement according to the International Protocol. Blood Pressure Monit 2006; 11:157-160.
    • (2006) Blood Pressure Monit , vol.11 , pp. 157-160
    • Stergiou, G.S.1    Giovas, P.P.2    Neofytou, M.S.3    Adamopoulos, D.N.4
  • 24
    • 0033940218 scopus 로고    scopus 로고
    • Tilt methodology in reflex syncope: Emerging evidence
    • Fitzpatrick AP, Zaidi A. Tilt methodology in reflex syncope: emerging evidence. J Am Coll Cardiol 2000; 36:179-180.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 179-180
    • Fitzpatrick, A.P.1    Zaidi, A.2
  • 25
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 26
    • 0043092329 scopus 로고    scopus 로고
    • Estimation of Central aortic pressure by SphygmoCor requires intra-arterial peripheral pressures
    • Cloud GC, Rajkumar C, Kooner J., Cooke J, Bulpitt CJ. Estimation of central aortic pressure by SphygmoCor requires intra-arterial peripheral pressures. Clin Sci 2003; 105:219-225.
    • (2003) Clin Sci , vol.105 , pp. 219-225
    • Cloud, G.C.1    Rajkumar, C.2    Kooner, J.3    Cooke, J.4    Bulpitt, C.J.5
  • 27
    • 0037360953 scopus 로고    scopus 로고
    • Peripheral blood pressure measurement is as good as applanation tonometry at predicting ascending aortic blood pressure
    • Davies JI, Band MM, Pringle s, Ogston S., Struthers AD. Peripheral blood pressure measurement is as good as applanation tonometry at predicting ascending aortic blood pressure. J Hypertens 2003; 21:571-576.
    • (2003) J Hypertens , vol.21 , pp. 571-576
    • Davies, J.I.1    Band, M.M.2    Pringle, S.3    Ogston, S.4    Struthers, A.D.5
  • 28
    • 43449104250 scopus 로고    scopus 로고
    • Use of generalized transfer function-derived Central blood pressure for the calculation of baroreflex gain
    • Studinger P, Ungi I, Lenard Z., Mersich B, Rudas L, Kollai M., et al. Use of generalized transfer function-derived central blood pressure for the calculation of baroreflex gain. J Hypertens 2008; 26:1156-1162.
    • (2008) J Hypertens , vol.26 , pp. 1156-1162
    • Studinger, P.1    Ungi, I.2    Lenard, Z.3    Mersich, B.4    Rudas, L.5    Kollai, M.6
  • 29
    • 73849145402 scopus 로고    scopus 로고
    • Caution using brachial systolic pressure to calibrate radial tonometric pressure waveforms: Lessons from invasive study
    • Davies JE, Shamuganathan M, Francis D.P., Mayet J., Hackett DR, Hughes AD. Caution using brachial systolic pressure to calibrate radial tonometric pressure waveforms: lessons from invasive study. Hypertension 2010; 55:e4.
    • (2010) Hypertension , vol.55
    • Davies, J.E.1    Shamuganathan, M.2    Francis, D.P.3    Mayet, J.4    Hackett, D.R.5    Hughes, A.D.6
  • 30
    • 79956065780 scopus 로고    scopus 로고
    • Blood pressure measurement: Retrospective and prospective views
    • Smulyan H, Safar ME. Blood pressure measurement: retrospective and prospective views. Am J Hypertens 2011; 24:628-634.
    • (2011) Am J Hypertens , vol.24 , pp. 628-634
    • Smulyan, H.1    Safar, M.E.2
  • 32
    • 65349125428 scopus 로고    scopus 로고
    • Comparison of changes in heart rate variability and blood pressure during nitroglycerin administration and head-up tilt testing
    • Bosch TA, Kaufman CL, Williamson E.B., Duprez DA, Dengel DR. Comparison of changes in heart rate variability and blood pressure during nitroglycerin administration and head-up tilt testing. Clin Auton Res 2009; 19:46-50.
    • (2009) Clin Auton Res , vol.19 , pp. 46-50
    • Bosch, T.A.1    Kaufman, C.L.2    Williamson, E.B.3    Duprez, D.A.4    Dengel, D.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.