메뉴 건너뛰기




Volumn 11, Issue 3, 2006, Pages 157-160

Validation of the Microlife BPA100 Plus device for self-home blood pressure measurement according to the International Protocol

Author keywords

Accuracy; European Society of Hypertension; Home blood pressure; International Protocol; Microlife; Self measurement; Validation

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CLINICAL ARTICLE; CLINICAL PROTOCOL; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEVICE; DIASTOLIC BLOOD PRESSURE; FEMALE; HOME MONITORING; HUMAN; INTERMETHOD COMPARISON; MALE; MEAN ARTERIAL PRESSURE; MEDICAL SOCIETY; OBSERVER VARIATION; OSCILLOMETRY; PRACTICE GUIDELINE; PRIORITY JOURNAL; READING; SAMPLE SIZE; SELF EVALUATION; SPHYGMOMANOMETER; SYSTOLIC BLOOD PRESSURE; VALIDATION PROCESS;

EID: 33746112932     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.mbp.0000209071.84965.bf     Document Type: Article
Times cited : (30)

References (9)
  • 1
    • 0037527647 scopus 로고    scopus 로고
    • 2003 European Society of Hypertension-European Society of Cardiology guidelines for the management of arterial hypertension
    • European Society of Hypertension-European Society of Cardiology Guidelines Committee. 2003 European Society of Hypertension-European Society of Cardiology guidelines for the management of arterial hypertension. J Hypertens 2003; 21:1011-1053.
    • (2003) J Hypertens , vol.21 , pp. 1011-1053
  • 2
    • 0347423198 scopus 로고    scopus 로고
    • Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure
    • Chobanian AV, Bakris GL, Black HR, Cushman WC, Green LA, Izzo JL Jr, et al. Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. Hypertension 2003; 42:1206-1252.
    • (2003) Hypertension , vol.42 , pp. 1206-1252
    • Chobanian, A.V.1    Bakris, G.L.2    Black, H.R.3    Cushman, W.C.4    Green, L.A.5    Izzo Jr., J.L.6
  • 3
    • 20144375119 scopus 로고    scopus 로고
    • The 2005 Canadian Hypertension Education Program recommendations for the management of hypertension: Part 1 - Blood pressure measurement, diagnosis and assessment of risk
    • Hemmelgarn BR, McAlister FA, Myers MG, McKay DW, Bolli P, Abbott C, et al., for the Canadian Hypertension Educational Program. The 2005 Canadian Hypertension Education Program recommendations for the management of hypertension: part 1 - blood pressure measurement, diagnosis and assessment of risk. Can J Cardiol 2005; 21:645-656.
    • (2005) Can J Cardiol , vol.21 , pp. 645-656
    • Hemmelgarn, B.R.1    McAlister, F.A.2    Myers, M.G.3    McKay, D.W.4    Bolli, P.5    Abbott, C.6
  • 4
    • 12444277817 scopus 로고    scopus 로고
    • European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement
    • O'Brien E, Asmar R, Beilin L, Imai Y, Mancia G, Mengden T, et al., on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens 2003; 21:821-848.
    • (2003) J Hypertens , vol.21 , pp. 821-848
    • O'Brien, E.1    Asmar, R.2    Beilin, L.3    Imai, Y.4    Mancia, G.5    Mengden, T.6
  • 5
    • 33746147474 scopus 로고    scopus 로고
    • dabl® Educational Trust: Devices for blood pressure measurement. http://www.dableducational.com. Assessed 2 November 2005.
  • 7
    • 0027218269 scopus 로고
    • The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices
    • O'Brien E, Petrie J, Littler WA, de Swiet M, Padfield PL, Altman D, et al. The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices. J Hypertens 1993; 11(Suppl 2):S43-S63.
    • (1993) J Hypertens , vol.11 , Issue.2 SUPPL.
    • O'Brien, E.1    Petrie, J.2    Littler, W.A.3    De Swiet, M.4    Padfield, P.L.5    Altman, D.6
  • 8
    • 0035992025 scopus 로고    scopus 로고
    • International Protocol for validation of blood pressure measuring devices in adults
    • N. Atkins and W. Gerin on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension.
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, et al., with the statistical assistance of N. Atkins and W. Gerin on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7:3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6
  • 9
    • 5144226187 scopus 로고    scopus 로고
    • Self-blood pressure monitoring at home is an important adjunct to clinic measurements in patients with hypertension
    • Stergiou G, Mengden T, Padfield P, Parati G, O'Brien E, on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. Self-blood pressure monitoring at home is an important adjunct to clinic measurements in patients with hypertension. BMJ 2004; 329:870-871.
    • (2004) BMJ , vol.329 , pp. 870-871
    • Stergiou, G.1    Mengden, T.2    Padfield, P.3    Parati, G.4    O'Brien, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.