메뉴 건너뛰기




Volumn 105, Issue 2, 2003, Pages 219-225

Estimation of central aortic pressure by SphygmoCor® requires intra-arterial peripheral pressures

Author keywords

Applanation tonometry; Catheter central pressure; Central aortic pressure; Generalized transfer function; Radial artery

Indexed keywords

ADULT; AGED; AORTA PRESSURE; ARTERIAL PRESSURE; ARTICLE; ASSAY; BLOOD PRESSURE MONITORING; BRACHIAL ARTERY; CONTROLLED STUDY; CUFF; DEVICE; DIASTOLIC BLOOD PRESSURE; FEMALE; HEART CATHETERIZATION; HUMAN; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; PRIORITY JOURNAL; RADIAL ARTERY; RECORDING; SYSTOLIC BLOOD PRESSURE; TECHNIQUE; TONOMETRY;

EID: 0043092329     PISSN: 01435221     EISSN: None     Source Type: Journal    
DOI: 10.1042/CS20030012     Document Type: Article
Times cited : (102)

References (26)
  • 1
    • 0035724737 scopus 로고    scopus 로고
    • Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform
    • Pauca, A., O'Rourke, M. and Kon, N. (2001) Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform. Hypertension 38, 932-937
    • (2001) Hypertension , vol.38 , pp. 932-937
    • Pauca, A.1    O'Rourke, M.2    Kon, N.3
  • 3
    • 0030475770 scopus 로고    scopus 로고
    • Derivation of the ascending aortic-carotid pressure transfer function with an arterial model
    • Karamanoglu, M. and Feneley, M. P. (1996) Derivation of the ascending aortic-carotid pressure transfer function with an arterial model. Am. J. Physiol. 271, H2399-H2404
    • (1996) Am. J. Physiol. , vol.271
    • Karamanoglu, M.1    Feneley, M.P.2
  • 4
    • 0030970060 scopus 로고    scopus 로고
    • Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function
    • Chen, C. H., Nevo, E., Fetics, B. et al. (1997) Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function. Circulation 95, 1827-1836
    • (1997) Circulation , vol.95 , pp. 1827-1836
    • Chen, C.H.1    Nevo, E.2    Fetics, B.3
  • 5
    • 0027460281 scopus 로고
    • An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man
    • Karamanoglu, M., O'Rourke, M. F., Avolio, A. P. and Kelly, R. P. (1993) An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. Eur. Heart J. 14, 160-167
    • (1993) Eur. Heart J. , vol.14 , pp. 160-167
    • Karamanoglu, M.1    O'Rourke, M.F.2    Avolio, A.P.3    Kelly, R.P.4
  • 6
    • 0003479390 scopus 로고
    • Determination of the ascending aortic pressure wave augmentation from the radial artery pressure pulse contour in humans
    • O'Rourke, M., Lei, J., Gallagher, D. E., and Avolio, A. (1995) Determination of the ascending aortic pressure wave augmentation from the radial artery pressure pulse contour in humans. Circulation 92, 745
    • (1995) Circulation , vol.92 , pp. 745
    • O'Rourke, M.1    Lei, J.2    Gallagher, D.E.3    Avolio, A.4
  • 7
    • 0032773452 scopus 로고    scopus 로고
    • Regarding the accuracy of generalized transfer functions for estimating central aortic blood pressure
    • Lehmann, E. D. (1999) Regarding the accuracy of generalized transfer functions for estimating central aortic blood pressure. J. Hypertens. 17, 1225-1227
    • (1999) J. Hypertens. , vol.17 , pp. 1225-1227
    • Lehmann, E.D.1
  • 8
    • 0034085677 scopus 로고    scopus 로고
    • Where is the evidence that radial artery tonometry can be used to accurately and noninvasively predict central aortic blood pressure in patients with diabetes?
    • Lehmann, E. D. (2000) Where is the evidence that radial artery tonometry can be used to accurately and noninvasively predict central aortic blood pressure in patients with diabetes? Diabetes Care 23, 869-871
    • (2000) Diabetes Care , vol.23 , pp. 869-871
    • Lehmann, E.D.1
  • 9
    • 0032984064 scopus 로고    scopus 로고
    • Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry
    • Fetics, B., Nevo, E., Chen, C. H. and Kass, D. A. (1999) Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry. IEEE Trans. Biomed. Eng. 46, 698-706
    • (1999) IEEE Trans. Biomed. Eng. , vol.46 , pp. 698-706
    • Fetics, B.1    Nevo, E.2    Chen, C.H.3    Kass, D.A.4
  • 10
    • 0030334214 scopus 로고    scopus 로고
    • Estimation of ascending aortic pressure from radial arterial pressure using a generalised transfer function
    • Takazawa, K., O'Rourke, M., Fukita, M. et al. (1996) Estimation of ascending aortic pressure from radial arterial pressure using a generalised transfer function. Z. Kardiol. 85, 137-139
    • (1996) Z. Kardiol. , vol.85 , pp. 137-139
    • Takazawa, K.1    O'Rourke, M.2    Fukita, M.3
  • 11
    • 26544462599 scopus 로고    scopus 로고
    • Reproducibility of non-invasive markers of arterial compliance measured by applanation tonometry
    • Hart, C. M. and Murphy, M. B. (2000) Reproducibility of non-invasive markers of arterial compliance measured by applanation tonometry. J. Hum. Hypertens. 18, S196
    • (2000) J. Hum. Hypertens. , vol.18
    • Hart, C.M.1    Murphy, M.B.2
  • 12
    • 0032818956 scopus 로고    scopus 로고
    • The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography
    • Siebenhofer, A., Kemp, C., Sutton, A. and Williams, B. (1999) The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography. J. Hum. Hypertens. 13, 625-629
    • (1999) J. Hum. Hypertens. , vol.13 , pp. 625-629
    • Siebenhofer, A.1    Kemp, C.2    Sutton, A.3    Williams, B.4
  • 13
    • 0032408206 scopus 로고    scopus 로고
    • Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
    • Wilkinson, I., Fuchs, S., Jansen, I. et al. (1998) Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis. J. Hum. Hypertens. 16, 2079-2084
    • (1998) J. Hum. Hypertens. , vol.16 , pp. 2079-2084
    • Wilkinson, I.1    Fuchs, S.2    Jansen, I.3
  • 14
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Altman, D. and Bland, J. (1983) Measurement in medicine: the analysis of method comparison studies. The Statistician 32, 307-317
    • (1983) The Statistician , vol.32 , pp. 307-317
    • Altman, D.1    Bland, J.2
  • 15
    • 0020403175 scopus 로고
    • Noninvasive estimation of central aortic pressure using the oscillometric method for analyzing systemic artery pulsatile blood flow: Comparative study of indirect systolic, diastolic, and mean brachial artery pressure with simultaneous direct ascending aortic pressure measurements
    • Borow, K. M. and Newburger, J. W. (1982) Noninvasive estimation of central aortic pressure using the oscillometric method for analyzing systemic artery pulsatile blood flow: comparative study of indirect systolic, diastolic, and mean brachial artery pressure with simultaneous direct ascending aortic pressure measurements. Am. Heart J. 103, 879-886
    • (1982) Am. Heart J. , vol.103 , pp. 879-886
    • Borow, K.M.1    Newburger, J.W.2
  • 16
    • 0016316447 scopus 로고
    • Comparison of direct and indirect arterial pressure measurements in hospitalised patients
    • Breit, S. and O'Rourke, M. (1974) Comparison of direct and indirect arterial pressure measurements in hospitalised patients. Aust. N. Z. J. Med. 4, 485-491
    • (1974) Aust. N. Z. J. Med. , vol.4 , pp. 485-491
    • Breit, S.1    O'Rourke, M.2
  • 17
    • 0021833226 scopus 로고
    • Blood pressure measurement in the elderly: Correlation of arterial stiffness with difference between intra-arterial and cuff pressures
    • Finnegan, T., Spence, D., Wong, D. and Wells, G. (1985) Blood pressure measurement in the elderly: correlation of arterial stiffness with difference between intra-arterial and cuff pressures. J. Hypertens. 3, 231-235
    • (1985) J. Hypertens. , vol.3 , pp. 231-235
    • Finnegan, T.1    Spence, D.2    Wong, D.3    Wells, G.4
  • 18
    • 0000251220 scopus 로고
    • Comparison of direct and indirect blood pressure determinations
    • Roberts, L., Smiley, J. and Manning, G. (1953) Comparison of direct and indirect blood pressure determinations. Circulation 8, 232-242
    • (1953) Circulation , vol.8 , pp. 232-242
    • Roberts, L.1    Smiley, J.2    Manning, G.3
  • 19
    • 0043264782 scopus 로고
    • Comparison of simultaneous indirect (auscultatory) and direct (intra-arterial) measurements of arterial pressure in man
    • Steele, J. (1941) Comparison of simultaneous indirect (auscultatory) and direct (intra-arterial) measurements of arterial pressure in man. J. Mt Sinai Hosp. 8, 1042-1050
    • (1941) J. Mt Sinai Hosp. , vol.8 , pp. 1042-1050
    • Steele, J.1
  • 20
    • 0032419233 scopus 로고    scopus 로고
    • Accuracy of a new wrist cuff oscillometric blood pressure device: Comparisons with intra-arterial and mercury manometer measurements
    • Watson, S., Wenzel, R., Di Matteo, C., Meier, B. and Luscher, T. (1998) Accuracy of a new wrist cuff oscillometric blood pressure device: comparisons with intra-arterial and mercury manometer measurements. Am. J. Hypertens. 11, 1469-1474
    • (1998) Am. J. Hypertens. , vol.11 , pp. 1469-1474
    • Watson, S.1    Wenzel, R.2    Di Matteo, C.3    Meier, B.4    Luscher, T.5
  • 21
    • 1842426223 scopus 로고    scopus 로고
    • Evaluation of three devices for self-measurement of blood pressure: According to the revised British Hypertension Society protocol: The Omron HEM-705CP, Phillips HP5332, and Nissei DS-175
    • O'Brien, E., Mee, F., Atkins, N. and Thomas, M. (1996) Evaluation of three devices for self-measurement of blood pressure: according to the revised British Hypertension Society protocol: the Omron HEM-705CP, Phillips HP5332, and Nissei DS-175. Blood Pressure Monitoring 1, 5-61
    • (1996) Blood Pressure Monitoring , vol.1 , pp. 5-61
    • O'Brien, E.1    Mee, F.2    Atkins, N.3    Thomas, M.4
  • 22
    • 0024237423 scopus 로고
    • Treatment for one year with perindopril: Effect on cardiac mass and arterial compliance in essential hypertension
    • Asmar, R., Journo, H., Lacolley, P., Billaud, E. and Levy, B. (1988) Treatment for one year with perindopril: effect on cardiac mass and arterial compliance in essential hypertension. J. Hypertens. 6, S33-S39
    • (1988) J. Hypertens. , vol.6
    • Asmar, R.1    Journo, H.2    Lacolley, P.3    Billaud, E.4    Levy, B.5
  • 23
    • 0027458595 scopus 로고
    • Arterial alterations with aging and high blood pressure. A non-invasive study of carotid and femoral arteries
    • Benetos, A., Laurent, S., Hoeks, A. P., Boutouyrie, P. H. and Safar, M. E. (1993) Arterial alterations with aging and high blood pressure. A non-invasive study of carotid and femoral arteries. Arterioscler. Thromb. 13, 90-97
    • (1993) Arterioscler. Thromb. , vol.13 , pp. 90-97
    • Benetos, A.1    Laurent, S.2    Hoeks, A.P.3    Boutouyrie, P.H.4    Safar, M.E.5
  • 24
    • 0030430615 scopus 로고    scopus 로고
    • Systemic arterial compliance is decreased in newly-diagnosed patients with coronary heart disease: Implications for prediction of risk
    • Cameron, J. D., Jennings, G. L. and Dart, A. M. (1996) Systemic arterial compliance is decreased in newly-diagnosed patients with coronary heart disease: implications for prediction of risk. J. Cardiovasc. Risk 3, 495-500
    • (1996) J. Cardiovasc. Risk , vol.3 , pp. 495-500
    • Cameron, J.D.1    Jennings, G.L.2    Dart, A.M.3
  • 25
    • 0024361736 scopus 로고
    • Regional aortic compliance studied by magnetic resonance imaging: The effects of age, training and coronary artery disease
    • Mohiaddin, R., Underwood, S., Bogren, H., Firmin, D., Klipstein, R. and Rees, R. (1989) Regional aortic compliance studied by magnetic resonance imaging: the effects of age, training and coronary artery disease. Br. Heart J. 62, 90-96
    • (1989) Br. Heart J. , vol.62 , pp. 90-96
    • Mohiaddin, R.1    Underwood, S.2    Bogren, H.3    Firmin, D.4    Klipstein, R.5    Rees, R.6
  • 26
    • 0015579398 scopus 로고
    • In vivo comparison of catheter manometer systems with the catheter-tip micromanometer
    • Gould, K., Trenholme, S. and Kennedy, J. (1973) In vivo comparison of catheter manometer systems with the catheter-tip micromanometer. J. Appl. Physiol. 34, 263-267
    • (1973) J. Appl. Physiol. , vol.34 , pp. 263-267
    • Gould, K.1    Trenholme, S.2    Kennedy, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.