메뉴 건너뛰기




Volumn 27, Issue 2, 2013, Pages 225-233

Brain monitoring revisited: What is it all about?

Author keywords

awareness; bispectral index; drug consumption; entropy; mortality; narcotrend

Indexed keywords

ANESTHETIC AGENT; DESFLURANE; HYPERTENSIVE FACTOR; PROPOFOL; REMIFENTANIL;

EID: 84884151297     PISSN: 15216896     EISSN: 1532169X     Source Type: Journal    
DOI: 10.1016/j.bpa.2013.06.006     Document Type: Review
Times cited : (15)

References (67)
  • 1
    • 0034424760 scopus 로고    scopus 로고
    • Bispectral index (BIS) and burst suppression: Revealing a part of the BIS algorithm
    • J. Bruhn, T.W. Bouillon, and S.L. Shafer Bispectral index (BIS) and burst suppression: revealing a part of the BIS algorithm J Clin Monit Comput 16 2000 593 596
    • (2000) J Clin Monit Comput , vol.16 , pp. 593-596
    • Bruhn, J.1    Bouillon, T.W.2    Shafer, S.L.3
  • 2
    • 0031657514 scopus 로고    scopus 로고
    • A primer for EEG signal processing in anesthesia
    • I.J. Rampil A primer for EEG signal processing in anesthesia Anesthesiology 89 1998 980 1002
    • (1998) Anesthesiology , vol.89 , pp. 980-1002
    • Rampil, I.J.1
  • 3
    • 0028533403 scopus 로고
    • An introduction to bispectral analysis for the electroencephalogram
    • J.C. Sigl, and N.G. Chamoun An introduction to bispectral analysis for the electroencephalogram J Clin Monit 10 1994 392 404
    • (1994) J Clin Monit , vol.10 , pp. 392-404
    • Sigl, J.C.1    Chamoun, N.G.2
  • 4
    • 0842348904 scopus 로고    scopus 로고
    • Description of the Entropy algorithm as applied in the Datex-Ohmeda S/5 Entropy Module
    • H. Viertio-Oja, V. Maja, and M. Sarkela Description of the Entropy algorithm as applied in the Datex-Ohmeda S/5 Entropy Module Acta Anaesthesiol.Scand 48 2004 154 161
    • (2004) Acta Anaesthesiol.Scand , vol.48 , pp. 154-161
    • Viertio-Oja, H.1    Maja, V.2    Sarkela, M.3
  • 6
    • 0347063709 scopus 로고    scopus 로고
    • The Narcotrend monitor. Development and interpretation algorithms
    • B. Schultz, S. Kreuer, and W. Wilhelm The Narcotrend monitor. Development and interpretation algorithms Anaesthesist 52 2003 1143 1148
    • (2003) Anaesthesist , vol.52 , pp. 1143-1148
    • Schultz, B.1    Kreuer, S.2    Wilhelm, W.3
  • 7
    • 0031772264 scopus 로고    scopus 로고
    • Evoked responses in anaesthesia
    • C. Thornton, and R.M. Sharpe Evoked responses in anaesthesia Br J Anaesth 81 1998 771 781
    • (1998) Br J Anaesth , vol.81 , pp. 771-781
    • Thornton, C.1    Sharpe, R.M.2
  • 8
    • 0344237323 scopus 로고    scopus 로고
    • Quality of perioperative AEP-variability of expert ratings
    • G. Schneider, W. Nahm, and E.F. Kochs Quality of perioperative AEP-variability of expert ratings Br J Anaesth 91 2003 905 908
    • (2003) Br J Anaesth , vol.91 , pp. 905-908
    • Schneider, G.1    Nahm, W.2    Kochs, E.F.3
  • 9
    • 0021811777 scopus 로고
    • Evoked responses-A neurophysiological indicator of depth of anaesthesia?
    • P.S. Sebel, C.P. Heneghan, and D.A. Ingram Evoked responses-a neurophysiological indicator of depth of anaesthesia? Br J Anaesth 57 1985 841 842
    • (1985) Br J Anaesth , vol.57 , pp. 841-842
    • Sebel, P.S.1    Heneghan, C.P.2    Ingram, D.A.3
  • 10
    • 33750100791 scopus 로고    scopus 로고
    • Correlation of the A-line ARX index with acoustically evoked potential amplitude
    • I. Wenningmann, S. Paprotny, and S. Strassmann Correlation of the A-line ARX index with acoustically evoked potential amplitude Br J Anaesth 97 2006 666 675
    • (2006) Br J Anaesth , vol.97 , pp. 666-675
    • Wenningmann, I.1    Paprotny, S.2    Strassmann, S.3
  • 11
    • 33845655590 scopus 로고    scopus 로고
    • Does monitoring bispectral index or spectral entropy reduce sevoflurane use?
    • I. Aime, N. Verroust, and C. Masson-Lefoll Does monitoring bispectral index or spectral entropy reduce sevoflurane use? Anesth Analg 103 2006 1469 1477
    • (2006) Anesth Analg , vol.103 , pp. 1469-1477
    • Aime, I.1    Verroust, N.2    Masson-Lefoll, C.3
  • 12
    • 9844245889 scopus 로고    scopus 로고
    • Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia. BIS Utility Study Group
    • T.J. Gan, P.S. Glass, and A. Windsor Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia. BIS Utility Study Group Anesthesiology 87 1997 808 815
    • (1997) Anesthesiology , vol.87 , pp. 808-815
    • Gan, T.J.1    Glass, P.S.2    Windsor, A.3
  • 13
    • 14344273787 scopus 로고    scopus 로고
    • The effect of encephalogram bispectral index monitoring during total intravenous anesthesia with propofol in outpatient surgery
    • C. Anez, J. Papaceit, and J.M. Sala The effect of encephalogram bispectral index monitoring during total intravenous anesthesia with propofol in outpatient surgery Rev Esp Anestesiol Reanim 48 2001 264 269
    • (2001) Rev Esp Anestesiol Reanim , vol.48 , pp. 264-269
    • Anez, C.1    Papaceit, J.2    Sala, J.M.3
  • 14
    • 0032902210 scopus 로고    scopus 로고
    • EEG bispectral index monitoring in sevoflurane or propofol anaesthesia: Analysis of direct costs and immediate recovery
    • A. Yli-Hankala, A. Vakkuri, and P. Annila EEG bispectral index monitoring in sevoflurane or propofol anaesthesia: analysis of direct costs and immediate recovery Acta Anaesthesiol Scand 43 1999 545 549
    • (1999) Acta Anaesthesiol Scand , vol.43 , pp. 545-549
    • Yli-Hankala, A.1    Vakkuri, A.2    Annila, P.3
  • 15
    • 0038110672 scopus 로고    scopus 로고
    • Narcotrend monitoring allows faster emergence and a reduction of drug consumption in propofol-remifentanil anesthesia
    • S. Kreuer, A. Biedler, and R. Larsen Narcotrend monitoring allows faster emergence and a reduction of drug consumption in propofol-remifentanil anesthesia Anesthesiology 99 2003 34 41
    • (2003) Anesthesiology , vol.99 , pp. 34-41
    • Kreuer, S.1    Biedler, A.2    Larsen, R.3
  • 16
    • 0037298912 scopus 로고    scopus 로고
    • Different benefit of bispectral index (BIS) in desflurane and propofol anesthesia
    • M. Luginbuhl, S. Wuthrich, and S. Petersen-Felix Different benefit of bispectral index (BIS) in desflurane and propofol anesthesia Acta Anaesthesiol Scand 47 2003 165 173
    • (2003) Acta Anaesthesiol Scand , vol.47 , pp. 165-173
    • Luginbuhl, M.1    Wuthrich, S.2    Petersen-Felix, S.3
  • 17
    • 0030721955 scopus 로고    scopus 로고
    • Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia
    • D. Song, G.P. Joshi, and P.F. White Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia Anesthesiology 87 1997 842 848
    • (1997) Anesthesiology , vol.87 , pp. 842-848
    • Song, D.1    Joshi, G.P.2    White, P.F.3
  • 18
    • 0035076593 scopus 로고    scopus 로고
    • The effect of bispectral index monitoring on anesthetic use and recovery in children anesthetized with sevoflurane in nitrous oxide
    • C.F. Bannister, K.K. Brosius, and J.C. Sigl The effect of bispectral index monitoring on anesthetic use and recovery in children anesthetized with sevoflurane in nitrous oxide Anesth Analg 92 2001 877 881
    • (2001) Anesth Analg , vol.92 , pp. 877-881
    • Bannister, C.F.1    Brosius, K.K.2    Sigl, J.C.3
  • 19
    • 0038240787 scopus 로고    scopus 로고
    • Effect of bispectral index monitoring on sevoflurane consumption
    • H. Basar, S. Ozcan, and U. Buyukkocak Effect of bispectral index monitoring on sevoflurane consumption Eur J Anaesthesiol 20 2003 396 400
    • (2003) Eur J Anaesthesiol , vol.20 , pp. 396-400
    • Basar, H.1    Ozcan, S.2    Buyukkocak, U.3
  • 20
    • 14644443585 scopus 로고    scopus 로고
    • Effects of bispectral index monitoring on recovery from surgical anesthesia in 1,580 inpatients from an academic medical center
    • J.D. Pavlin, K.J. Souter, and J.Y. Hong Effects of bispectral index monitoring on recovery from surgical anesthesia in 1,580 inpatients from an academic medical center Anesthesiology 102 2005 566 573
    • (2005) Anesthesiology , vol.102 , pp. 566-573
    • Pavlin, J.D.1    Souter, K.J.2    Hong, J.Y.3
  • 21
    • 0035375466 scopus 로고    scopus 로고
    • Bispectral index monitoring in sevoflurane and remifentanil anesthesia. Analysis of drugs management and immediate recovery
    • S. Paventi, A. Santevecchi, and E. Metta Bispectral index monitoring in sevoflurane and remifentanil anesthesia. Analysis of drugs management and immediate recovery Minerva Anestesiol 67 2001 435 439
    • (2001) Minerva Anestesiol , vol.67 , pp. 435-439
    • Paventi, S.1    Santevecchi, A.2    Metta, E.3
  • 22
    • 1642314446 scopus 로고    scopus 로고
    • Does the use of electroencephalographic bispectral index or auditory evoked potential index monitoring facilitate recovery after desflurane anesthesia in the ambulatory setting?
    • P.F. White, H. Ma, and J. Tang Does the use of electroencephalographic bispectral index or auditory evoked potential index monitoring facilitate recovery after desflurane anesthesia in the ambulatory setting? Anesthesiology 100 2004 811 817
    • (2004) Anesthesiology , vol.100 , pp. 811-817
    • White, P.F.1    Ma, H.2    Tang, J.3
  • 23
    • 22944491748 scopus 로고    scopus 로고
    • Narcotrend or bispectral index monitoring during desflurane-remifentanil anesthesia: A comparison with a standard practice protocol
    • [table]
    • S. Kreuer, J. Bruhn, and C. Stracke Narcotrend or bispectral index monitoring during desflurane-remifentanil anesthesia: a comparison with a standard practice protocol Anesth Analg 101 2005 427 434 [table]
    • (2005) Anesth Analg , vol.101 , pp. 427-434
    • Kreuer, S.1    Bruhn, J.2    Stracke, C.3
  • 24
    • 0036239088 scopus 로고    scopus 로고
    • Titration of isoflurane using BIS index improves early recovery of elderly patients undergoing orthopedic surgeries
    • J. Wong, D. Song, and H. Blanshard Titration of isoflurane using BIS index improves early recovery of elderly patients undergoing orthopedic surgeries Can J Anaesth 49 2002 13 18
    • (2002) Can J Anaesth , vol.49 , pp. 13-18
    • Wong, J.1    Song, D.2    Blanshard, H.3
  • 25
    • 0035127571 scopus 로고    scopus 로고
    • Reduced isoflurane consumption with bispectral index monitoring
    • B. Guignard, C. Coste, and C. Menigaux Reduced isoflurane consumption with bispectral index monitoring Acta Anaesthesiol Scand 45 2001 308 314
    • (2001) Acta Anaesthesiol Scand , vol.45 , pp. 308-314
    • Guignard, B.1    Coste, C.2    Menigaux, C.3
  • 26
    • 0034854739 scopus 로고    scopus 로고
    • The effect of bispectral index monitoring on end-tidal gas concentration and recovery duration after outpatient anesthesia
    • D.J. Pavlin, J.Y. Hong, and P.R. Freund The effect of bispectral index monitoring on end-tidal gas concentration and recovery duration after outpatient anesthesia Anesth Analg 93 2001 613 619
    • (2001) Anesth Analg , vol.93 , pp. 613-619
    • Pavlin, D.J.1    Hong, J.Y.2    Freund, P.R.3
  • 27
    • 25844514234 scopus 로고    scopus 로고
    • Impact of the narcotrend index on propofol consumption and emergence times during total intravenous anaesthesia with propofol and remifentanil in children: A clinical utility study
    • F. Weber, F. Pohl, and H. Hollnberger Impact of the narcotrend index on propofol consumption and emergence times during total intravenous anaesthesia with propofol and remifentanil in children: a clinical utility study Eur J Anaesthesiol 22 2005 741 747
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 741-747
    • Weber, F.1    Pohl, F.2    Hollnberger, H.3
  • 28
    • 23044478546 scopus 로고    scopus 로고
    • Spectral entropy monitoring is associated with reduced propofol use and faster emergence in propofol-nitrous oxide-alfentanil anesthesia
    • A. Vakkuri, A. Yli-Hankala, and R. Sandin Spectral entropy monitoring is associated with reduced propofol use and faster emergence in propofol-nitrous oxide-alfentanil anesthesia Anesthesiology 103 2005 274 279
    • (2005) Anesthesiology , vol.103 , pp. 274-279
    • Vakkuri, A.1    Yli-Hankala, A.2    Sandin, R.3
  • 29
    • 84875908635 scopus 로고    scopus 로고
    • Impact of entropy monitoring on volatile anesthetic uptake
    • H.T. El, P. Van Der Linden, and H.S. De Impact of entropy monitoring on volatile anesthetic uptake Anesthesiology 2013
    • (2013) Anesthesiology
    • El, H.T.1    Van Der Linden, P.2    De, H.S.3
  • 30
    • 3342896458 scopus 로고    scopus 로고
    • Effects of Bispectral Index monitoring on ambulatory anesthesia: A meta-analysis of randomized controlled trials and a cost analysis
    • S.S. Liu Effects of Bispectral Index monitoring on ambulatory anesthesia: a meta-analysis of randomized controlled trials and a cost analysis Anesthesiology 101 2004 311 315
    • (2004) Anesthesiology , vol.101 , pp. 311-315
    • Liu, S.S.1
  • 31
    • 33750376621 scopus 로고    scopus 로고
    • Reduction in anaesthetic drug consumption is correlated with mean titrated intra-operative Bispectral Index values
    • R.K. Ellerkmann, S. Kreuer, and W. Wilhelm Reduction in anaesthetic drug consumption is correlated with mean titrated intra-operative Bispectral Index values Acta Anaesthesiol Scand 50 2006 1244 1249
    • (2006) Acta Anaesthesiol Scand , vol.50 , pp. 1244-1249
    • Ellerkmann, R.K.1    Kreuer, S.2    Wilhelm, W.3
  • 32
    • 75749089980 scopus 로고    scopus 로고
    • The entropy module and bispectral index as guidance for propofol-remifentanil anaesthesia in combination with regional anaesthesia compared with a standard clinical practice group
    • R.K. Ellerkmann, M. Soehle, and G. Riese The entropy module and bispectral index as guidance for propofol-remifentanil anaesthesia in combination with regional anaesthesia compared with a standard clinical practice group Anaesth Intensive Care 38 2010 159 166
    • (2010) Anaesth Intensive Care , vol.38 , pp. 159-166
    • Ellerkmann, R.K.1    Soehle, M.2    Riese, G.3
  • 33
    • 38449098872 scopus 로고    scopus 로고
    • Narcotrend-assisted propofol/remifentanil anaesthesia vs clinical practice: Does it make a difference?
    • I. Rundshagen, T. Hardt, and K. Cortina Narcotrend-assisted propofol/remifentanil anaesthesia vs clinical practice: does it make a difference? Br J Anaesth 99 2007 686 693
    • (2007) Br J Anaesth , vol.99 , pp. 686-693
    • Rundshagen, I.1    Hardt, T.2    Cortina, K.3
  • 34
    • 32544442007 scopus 로고    scopus 로고
    • Bispectral index monitoring does not improve early recovery of geriatric outpatients undergoing brief surgical procedures
    • E. Zohar, I. Luban, and P.F. White Bispectral index monitoring does not improve early recovery of geriatric outpatients undergoing brief surgical procedures Can J Anaesth 53 2006 20 25
    • (2006) Can J Anaesth , vol.53 , pp. 20-25
    • Zohar, E.1    Luban, I.2    White, P.F.3
  • 35
    • 2542562742 scopus 로고    scopus 로고
    • Bispectral index monitoring to prevent awareness during anaesthesia: The B-Aware randomised controlled trial
    • P.S. Myles, K. Leslie, and J. McNeil Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial Lancet 363 2004 1757 1763
    • (2004) Lancet , vol.363 , pp. 1757-1763
    • Myles, P.S.1    Leslie, K.2    McNeil, J.3
  • 36
    • 40849116197 scopus 로고    scopus 로고
    • Anesthesia awareness and the bispectral index
    • M.S. Avidan, L. Zhang, and B.A. Burnside Anesthesia awareness and the bispectral index N Engl J Med 358 2008 1097 1108
    • (2008) N Engl J Med , vol.358 , pp. 1097-1108
    • Avidan, M.S.1    Zhang, L.2    Burnside, B.A.3
  • 37
    • 84860389403 scopus 로고    scopus 로고
    • Prevention of intraoperative awareness in a high-risk surgical population
    • M.S. Avidan, E. Jacobsohn, and D. Glick Prevention of intraoperative awareness in a high-risk surgical population N Engl J Med 365 2011 591 600
    • (2011) N Engl J Med , vol.365 , pp. 591-600
    • Avidan, M.S.1    Jacobsohn, E.2    Glick, D.3
  • 38
    • 84866707863 scopus 로고    scopus 로고
    • Prevention of intraoperative awareness with explicit recall in an unselected surgical population: A randomized comparative effectiveness trial
    • G.A. Mashour, A. Shanks, and K.K. Tremper Prevention of intraoperative awareness with explicit recall in an unselected surgical population: a randomized comparative effectiveness trial Anesthesiology 117 2012 717 725
    • (2012) Anesthesiology , vol.117 , pp. 717-725
    • Mashour, G.A.1    Shanks, A.2    Tremper, K.K.3
  • 39
    • 0033768931 scopus 로고    scopus 로고
    • Clinical impact of hypnotic-titration guidelines based on EEG bispectral index (BIS) monitoring during routine anesthetic care
    • J.W. Johansen, P.S. Sebel, and J.C. Sigl Clinical impact of hypnotic-titration guidelines based on EEG bispectral index (BIS) monitoring during routine anesthetic care J Clin Anesth 12 2000 433 443
    • (2000) J Clin Anesth , vol.12 , pp. 433-443
    • Johansen, J.W.1    Sebel, P.S.2    Sigl, J.C.3
  • 40
    • 11344257731 scopus 로고    scopus 로고
    • Bispectral index and A-line AAI index as guidance for desflurane-remifentanil anaesthesia compared with a standard practice group: A multicentre study
    • J. Bruhn, S. Kreuer, and P. Bischoff Bispectral index and A-line AAI index as guidance for desflurane-remifentanil anaesthesia compared with a standard practice group: a multicentre study Br J Anaesth 94 2005 63 69
    • (2005) Br J Anaesth , vol.94 , pp. 63-69
    • Bruhn, J.1    Kreuer, S.2    Bischoff, P.3
  • 41
    • 0037381724 scopus 로고    scopus 로고
    • Impact of bispectral index monitoring on fast tracking of gynecologic patients undergoing laparoscopic surgery
    • S. Ahmad, M. Yilmaz, and R.J. Marcus Impact of bispectral index monitoring on fast tracking of gynecologic patients undergoing laparoscopic surgery Anesthesiology 98 2003 849 852
    • (2003) Anesthesiology , vol.98 , pp. 849-852
    • Ahmad, S.1    Yilmaz, M.2    Marcus, R.J.3
  • 42
    • 0036687261 scopus 로고    scopus 로고
    • Efficacy of bispectral index monitoring in improving anesthetic management, economics, and use of the operating theater
    • Y. Morimoto, S. Oka, and M. Mii Efficacy of bispectral index monitoring in improving anesthetic management, economics, and use of the operating theater Masui 51 2002 862 868
    • (2002) Masui , vol.51 , pp. 862-868
    • Morimoto, Y.1    Oka, S.2    Mii, M.3
  • 43
    • 0034758813 scopus 로고    scopus 로고
    • Sevoflurane titration using bispectral index decreases postoperative vomiting in phase II recovery after ambulatory surgery
    • K.A. Nelskyla, A.M. Yli-Hankala, and P.H. Puro Sevoflurane titration using bispectral index decreases postoperative vomiting in phase II recovery after ambulatory surgery Anesth Analg 93 2001 1165 1169
    • (2001) Anesth Analg , vol.93 , pp. 1165-1169
    • Nelskyla, K.A.1    Yli-Hankala, A.M.2    Puro, P.H.3
  • 44
    • 0032933744 scopus 로고    scopus 로고
    • Awareness during anesthesia: A closed claims analysis
    • K.B. Domino, K.L. Posner, and R.A. Caplan Awareness during anesthesia: a closed claims analysis Anesthesiology 90 1999 1053 1061
    • (1999) Anesthesiology , vol.90 , pp. 1053-1061
    • Domino, K.B.1    Posner, K.L.2    Caplan, R.A.3
  • 45
    • 0034716487 scopus 로고    scopus 로고
    • Awareness during anaesthesia: A prospective case study
    • R.H. Sandin, G. Enlund, and P. Samuelsson Awareness during anaesthesia: a prospective case study Lancet 355 2000 707 711
    • (2000) Lancet , vol.355 , pp. 707-711
    • Sandin, R.H.1    Enlund, G.2    Samuelsson, P.3
  • 46
    • 4143097160 scopus 로고    scopus 로고
    • The incidence of awareness during anesthesia: A multicenter United States study
    • [table]
    • P.S. Sebel, T.A. Bowdle, and M.M. Ghoneim The incidence of awareness during anesthesia: a multicenter United States study Anesth Analg 99 2004 833 839 [table]
    • (2004) Anesth Analg , vol.99 , pp. 833-839
    • Sebel, P.S.1    Bowdle, T.A.2    Ghoneim, M.M.3
  • 47
    • 0347473802 scopus 로고    scopus 로고
    • Reduction in the incidence of awareness using BIS monitoring
    • A. Ekman, M.L. Lindholm, and C. Lennmarken Reduction in the incidence of awareness using BIS monitoring Acta Anaesthesiol Scand 48 2004 20 26
    • (2004) Acta Anaesthesiol Scand , vol.48 , pp. 20-26
    • Ekman, A.1    Lindholm, M.L.2    Lennmarken, C.3
  • 48
    • 82255195507 scopus 로고    scopus 로고
    • Bispectral index monitoring prevent awareness during total intravenous anesthesia: A prospective, randomized, double-blinded, multi-center controlled trial
    • C. Zhang, L. Xu, and Y.Q. Ma Bispectral index monitoring prevent awareness during total intravenous anesthesia: a prospective, randomized, double-blinded, multi-center controlled trial Chin Med J (Engl) 124 2011 3664 3669
    • (2011) Chin Med J (Engl) , vol.124 , pp. 3664-3669
    • Zhang, C.1    Xu, L.2    Ma, Y.Q.3
  • 49
    • 16844387334 scopus 로고    scopus 로고
    • Impact of patient age on propofol consumption during propofol- remifentanil anaesthesia
    • S. Kreuer, J.U. Schreiber, and J. Bruhn Impact of patient age on propofol consumption during propofol-remifentanil anaesthesia Eur J Anaesthesiol 22 2005 123 128
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 123-128
    • Kreuer, S.1    Schreiber, J.U.2    Bruhn, J.3
  • 50
    • 0033970358 scopus 로고    scopus 로고
    • Influence of age on hypnotic requirement, bispectral index, and 95% spectral edge frequency associated with sedation induced by sevoflurane
    • T. Katoh, H. Bito, and S. Sato Influence of age on hypnotic requirement, bispectral index, and 95% spectral edge frequency associated with sedation induced by sevoflurane Anesthesiology 92 2000 55 61
    • (2000) Anesthesiology , vol.92 , pp. 55-61
    • Katoh, T.1    Bito, H.2    Sato, S.3
  • 51
    • 0032936803 scopus 로고    scopus 로고
    • The dynamic relationship between end-tidal sevoflurane and isoflurane concentrations and bispectral index and spectral edge frequency of the electroencephalogram
    • E. Olofsen, and A. Dahan The dynamic relationship between end-tidal sevoflurane and isoflurane concentrations and bispectral index and spectral edge frequency of the electroencephalogram Anesthesiology 90 1999 1345 1353
    • (1999) Anesthesiology , vol.90 , pp. 1345-1353
    • Olofsen, E.1    Dahan, A.2
  • 52
    • 9444236785 scopus 로고    scopus 로고
    • Spectral entropy and bispectral index as measures of the electroencephalographic effects of sevoflurane
    • R.K. Ellerkmann, V.M. Liermann, and T.M. Alves Spectral entropy and bispectral index as measures of the electroencephalographic effects of sevoflurane Anesthesiology 101 2004 1275 1282
    • (2004) Anesthesiology , vol.101 , pp. 1275-1282
    • Ellerkmann, R.K.1    Liermann, V.M.2    Alves, T.M.3
  • 53
    • 33646180669 scopus 로고    scopus 로고
    • Spectral entropy and bispectral index as measures of the electroencephalographic effects of propofol
    • R.K. Ellerkmann, M. Soehle, and T.M. Alves Spectral entropy and bispectral index as measures of the electroencephalographic effects of propofol Anesth Analg 102 2006 1456 1462
    • (2006) Anesth Analg , vol.102 , pp. 1456-1462
    • Ellerkmann, R.K.1    Soehle, M.2    Alves, T.M.3
  • 54
    • 41349112567 scopus 로고    scopus 로고
    • Comparative pharmacodynamic modeling using bispectral and narcotrend-index with and without a pharmacodynamic plateau during sevoflurane anesthesia
    • [table]
    • S. Kreuer, J. Bruhn, and E. Walter Comparative pharmacodynamic modeling using bispectral and narcotrend-index with and without a pharmacodynamic plateau during sevoflurane anesthesia Anesth Analg 106 2008 1171 1181 [table]
    • (2008) Anesth Analg , vol.106 , pp. 1171-1181
    • Kreuer, S.1    Bruhn, J.2    Walter, E.3
  • 55
    • 70349251133 scopus 로고    scopus 로고
    • Comparative pharmacodynamic modeling of desflurane, sevoflurane and isoflurane
    • S. Kreuer, J. Bruhn, and W. Wilhelm Comparative pharmacodynamic modeling of desflurane, sevoflurane and isoflurane J Clin Monit Comput 23 2009 299 305
    • (2009) J Clin Monit Comput , vol.23 , pp. 299-305
    • Kreuer, S.1    Bruhn, J.2    Wilhelm, W.3
  • 56
    • 41949131605 scopus 로고    scopus 로고
    • Failure of two commercial indexes and spectral parameters to reflect the pharmacodynamic effect of desflurane on EEG
    • S. Kreuer, J. Bruhn, and R. Ellerkmann Failure of two commercial indexes and spectral parameters to reflect the pharmacodynamic effect of desflurane on EEG J Clin Monit Comput 22 2008 149 158
    • (2008) J Clin Monit Comput , vol.22 , pp. 149-158
    • Kreuer, S.1    Bruhn, J.2    Ellerkmann, R.3
  • 57
    • 4644289240 scopus 로고    scopus 로고
    • Application of bispectral index and narcotrend index to the measurement of the electroencephalographic effects of isoflurane with and without burst suppression
    • S. Kreuer, J. Bruhn, and R. Larsen Application of bispectral index and narcotrend index to the measurement of the electroencephalographic effects of isoflurane with and without burst suppression Anesthesiology 101 2004 847 854
    • (2004) Anesthesiology , vol.101 , pp. 847-854
    • Kreuer, S.1    Bruhn, J.2    Larsen, R.3
  • 58
    • 1342267330 scopus 로고    scopus 로고
    • Narcotrend index versus bispectral index as electroencephalogram measures of anesthetic drug effect during propofol anesthesia
    • S. Kreuer, W. Wilhelm, and U. Grundmann Narcotrend index versus bispectral index as electroencephalogram measures of anesthetic drug effect during propofol anesthesia Anesth Analg 98 2004 692 697
    • (2004) Anesth Analg , vol.98 , pp. 692-697
    • Kreuer, S.1    Wilhelm, W.2    Grundmann, U.3
  • 59
    • 34250900993 scopus 로고    scopus 로고
    • Pharmacokinetic-pharmacodynamic models for inhaled anaesthetics
    • S. Kreuer, J. Bruhn, and W. Wilhelm Pharmacokinetic-pharmacodynamic models for inhaled anaesthetics Anaesthesist 56 2007 538 556
    • (2007) Anaesthesist , vol.56 , pp. 538-556
    • Kreuer, S.1    Bruhn, J.2    Wilhelm, W.3
  • 60
    • 81855221694 scopus 로고    scopus 로고
    • Relationship between bispectral index values and volatile anesthetic concentrations during the maintenance phase of anesthesia in the B-unaware trial
    • E.L. Whitlock, A.J. Villafranca, and N. Lin Relationship between bispectral index values and volatile anesthetic concentrations during the maintenance phase of anesthesia in the B-unaware trial Anesthesiology 115 2011 1209 1218
    • (2011) Anesthesiology , vol.115 , pp. 1209-1218
    • Whitlock, E.L.1    Villafranca, A.J.2    Lin, N.3
  • 61
    • 81855194109 scopus 로고    scopus 로고
    • Does depth of anesthesia monitoring improve postoperative outcomes?
    • T.G. Monk, and B.C. Weldon Does depth of anesthesia monitoring improve postoperative outcomes? Curr Opin Anaesthesiol 24 2011 665 669
    • (2011) Curr Opin Anaesthesiol , vol.24 , pp. 665-669
    • Monk, T.G.1    Weldon, B.C.2
  • 62
    • 59649090562 scopus 로고    scopus 로고
    • Mortality within 2 years after surgery in relation to low intraoperative bispectral index values and preexisting malignant disease
    • M.L. Lindholm, S. Traff, and F. Granath Mortality within 2 years after surgery in relation to low intraoperative bispectral index values and preexisting malignant disease Anesth Analg 108 2009 508 512
    • (2009) Anesth Analg , vol.108 , pp. 508-512
    • Lindholm, M.L.1    Traff, S.2    Granath, F.3
  • 63
    • 77949296405 scopus 로고    scopus 로고
    • The effect of bispectral index monitoring on long-term survival in the B-aware trial
    • K. Leslie, P.S. Myles, and A. Forbes The effect of bispectral index monitoring on long-term survival in the B-aware trial Anesth Analg 110 2010 816 822
    • (2010) Anesth Analg , vol.110 , pp. 816-822
    • Leslie, K.1    Myles, P.S.2    Forbes, A.3
  • 64
    • 77951673797 scopus 로고    scopus 로고
    • Association of perioperative risk factors and cumulative duration of low bispectral index with intermediate-term mortality after cardiac surgery in the B-unaware Trial
    • M.D. Kertai, N. Pal, and B.J. Palanca Association of perioperative risk factors and cumulative duration of low bispectral index with intermediate-term mortality after cardiac surgery in the B-unaware Trial Anesthesiology 112 2010 1116 1127
    • (2010) Anesthesiology , vol.112 , pp. 1116-1127
    • Kertai, M.D.1    Pal, N.2    Palanca, B.J.3
  • 65
    • 79953881805 scopus 로고    scopus 로고
    • Bispectral index monitoring, duration of bispectral index below 45, patient risk factors, and intermediate-term mortality after noncardiac surgery in the B-unaware trial
    • M.D. Kertai, B.J. Palanca, and N. Pal Bispectral index monitoring, duration of bispectral index below 45, patient risk factors, and intermediate-term mortality after noncardiac surgery in the B-unaware trial Anesthesiology 114 2011 545 556
    • (2011) Anesthesiology , vol.114 , pp. 545-556
    • Kertai, M.D.1    Palanca, B.J.2    Pal, N.3
  • 66
    • 84861595324 scopus 로고    scopus 로고
    • Hospital stay and mortality are increased in patients having a «triple low» of low blood pressure, low bispectral index, and low minimum alveolar concentration of volatile anesthesia
    • D.I. Sessler, J.C. Sigl, and S.D. Kelley Hospital stay and mortality are increased in patients having a «triple low» of low blood pressure, low bispectral index, and low minimum alveolar concentration of volatile anesthesia Anesthesiology 116 2012 1195 1203
    • (2012) Anesthesiology , vol.116 , pp. 1195-1203
    • Sessler, D.I.1    Sigl, J.C.2    Kelley, S.D.3
  • 67
    • 70350743287 scopus 로고    scopus 로고
    • Maximizing prediction probability PK as an alternative semiparametric approach to estimate the plasma effect-site equilibration rate constant ke0
    • R.K. Ellerkmann, J. Bruhn, and M. Soehle Maximizing prediction probability PK as an alternative semiparametric approach to estimate the plasma effect-site equilibration rate constant ke0 Anesth Analg 109 2009 1470 1488
    • (2009) Anesth Analg , vol.109 , pp. 1470-1488
    • Ellerkmann, R.K.1    Bruhn, J.2    Soehle, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.