메뉴 건너뛰기




Volumn 101, Issue 4, 2004, Pages 847-854

Application of Bispectral Index® Narcotrend® index to the measurement of the etectroencephalographic effects of isoflurane with and without burst suppression

Author keywords

[No Author keywords available]

Indexed keywords

ISOFLURANE;

EID: 4644289240     PISSN: 00033022     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000542-200410000-00008     Document Type: Article
Times cited : (54)

References (16)
  • 1
    • 0031657514 scopus 로고    scopus 로고
    • A primer for electroencephalogram signal processing in anesthesia
    • Rampil IJ: A primer for electroencephalogram signal processing in anesthesia. ANESTHESIOLOGY 1998; 89:980-1002
    • (1998) Anesthesiology , vol.89 , pp. 980-1002
    • Rampil, I.J.1
  • 2
    • 0038110672 scopus 로고    scopus 로고
    • Narcotrend monitoring allows faster emergence and a reduction of drug consumption in propofol-remifentanil anesthesia
    • Kreuer S, Biedler A, Larsen R, Altmann S, Wilhelm W: Narcotrend monitoring allows faster emergence and a reduction of drug consumption in propofol-remifentanil anesthesia. ANESTHESIOLOGY 2003; 99:34-41
    • (2003) Anesthesiology , vol.99 , pp. 34-41
    • Kreuer, S.1    Biedler, A.2    Larsen, R.3    Altmann, S.4    Wilhelm, W.5
  • 3
    • 0035543938 scopus 로고    scopus 로고
    • The Narcotrend-a new electroencephalogram monitor designed to measure the depth of anaesthesia: A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia
    • Kreuer S, Biedler A, Larsen R, Schoth S, Altmann S, Wilhelm W: The Narcotrend-a new electroencephalogram monitor designed to measure the depth of anaesthesia: A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia. Anaesthesist 2001; 50:921-5
    • (2001) Anaesthesist , vol.50 , pp. 921-925
    • Kreuer, S.1    Biedler, A.2    Larsen, R.3    Schoth, S.4    Altmann, S.5    Wilhelm, W.6
  • 4
    • 0036829311 scopus 로고    scopus 로고
    • Narcotrend, bispectral index and classical electroencephalogram variables during emergence from propofol/remifentanil anesthesia
    • Schmidt GN, Bischoff P, Standl T, Voigt M, Papavero L, Schulte am Esch J: Narcotrend, bispectral index and classical electroencephalogram variables during emergence from propofol/remifentanil anesthesia. Anesth Analg 2002; 95: 1324-30
    • (2002) Anesth Analg , vol.95 , pp. 1324-1330
    • Schmidt, G.N.1    Bischoff, P.2    Standl, T.3    Voigt, M.4    Papavero, L.5    Schulte Am Esch, J.6
  • 5
    • 0030901893 scopus 로고    scopus 로고
    • Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers
    • Glass PS, Bloom M, Kearse L, Rosow C, Sebel P, Manberg P: Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers. ANESTHESIOLOGY 1997; 86:836-47
    • (1997) Anesthesiology , vol.86 , pp. 836-847
    • Glass, P.S.1    Bloom, M.2    Kearse, L.3    Rosow, C.4    Sebel, P.5    Manberg, P.6
  • 6
    • 0031018117 scopus 로고    scopus 로고
    • A comparison of spectral edge, delta power, and bispectral index as electroencephalogram measures of alfentanil, propofol, and miclazolam drug effect
    • Billard V, Gambus PL, Chamoun N, Stanski DR, Shafer SL: A comparison of spectral edge, delta power, and bispectral index as electroencephalogram measures of alfentanil, propofol, and miclazolam drug effect. Clin Pharmacol Ther 1997; 61:45-5
    • (1997) Clin Pharmacol Ther , vol.61 , pp. 45-45
    • Billard, V.1    Gambus, P.L.2    Chamoun, N.3    Stanski, D.R.4    Shafer, S.L.5
  • 7
    • 0018394195 scopus 로고
    • Simultaneous modeling of pharmacokinetics and pharmacodynamics: Application to d-tubocurarine
    • Sheiner LB, Stanski DR, Vozeh S, Miller RD, Ham J: Simultaneous modeling of pharmacokinetics and pharmacodynamics: Application to d-tubocurarine. Clin Pharmacol Ther 1979; 25:358-71
    • (1979) Clin Pharmacol Ther , vol.25 , pp. 358-371
    • Sheiner, L.B.1    Stanski, D.R.2    Vozeh, S.3    Miller, R.D.4    Ham, J.5
  • 8
    • 0025907775 scopus 로고
    • Electroencephalographic quantitation of opioid effect: Comparative pharmacodynamics of fentanyl and sufentanil
    • Scott JC, Cooke JE, Stanski DR: Electroencephalographic quantitation of opioid effect: Comparative pharmacodynamics of fentanyl and sufentanil. ANESTHESIOLOGY 1991; 74:34-42
    • (1991) Anesthesiology , vol.74 , pp. 34-42
    • Scott, J.C.1    Cooke, J.E.2    Stanski, D.R.3
  • 9
    • 0032839987 scopus 로고    scopus 로고
    • Comparative pharmacodynamic modeling of the electroencephalography- slowing effect of isoflurane, sevoflurane, and desflurane
    • Rehberg B, Bouillon T, Zinserling J, Hoeft A: Comparative pharmacodynamic modeling of the electroencephalography-slowing effect of isoflurane, sevoflurane, and desflurane. ANESTHESIOLOGY 1999; 91:397-405
    • (1999) Anesthesiology , vol.91 , pp. 397-405
    • Rehberg, B.1    Bouillon, T.2    Zinserling, J.3    Hoeft, A.4
  • 10
    • 0032936803 scopus 로고    scopus 로고
    • The dynamic relationship between end-tidal sevoflurane and isoflurane concentrations and Bispectral Index and spectral edge frequency of the electroencephalogram
    • Olofsen E, Dahan A: The dynamic relationship between end-tidal sevoflurane and isoflurane concentrations and Bispectral Index and spectral edge frequency of the electroencephalogram. ANESTHESIOLOGY 1999; 90:1345-53
    • (1999) Anesthesiology , vol.90 , pp. 1345-1353
    • Olofsen, E.1    Dahan, A.2
  • 11
    • 0030021080 scopus 로고    scopus 로고
    • Measuring the performance of anesthetic depth indicators
    • Smith WD, Dutton RC, Smith NT: Measuring the performance of anesthetic depth indicators. ANESTHESIOLOGY 1996; 84:38-51
    • (1996) Anesthesiology , vol.84 , pp. 38-51
    • Smith, W.D.1    Dutton, R.C.2    Smith, N.T.3
  • 12
    • 0003043542 scopus 로고
    • The possible effect of the aggregation of the molecules of hemoglobin on its dissociation curves
    • Hill AV: The possible effect of the aggregation of the molecules of hemoglobin on its dissociation curves. J Physiol 1910; 40:iv-vii
    • (1910) J Physiol , vol.40
    • Hill, A.V.1
  • 14
    • 0034946118 scopus 로고    scopus 로고
    • Shannon entropy applied to the measurement of the electroencephalographic effects of desflurane
    • Bruhn J, Lehmann LE, Roepcke H, Bouillon TW, Hoeft A: Shannon entropy applied to the measurement of the electroencephalographic effects of desflurane. ANESTHESIOLOGY 2001; 95:30-5
    • (2001) Anesthesiology , vol.95 , pp. 30-35
    • Bruhn, J.1    Lehmann, L.E.2    Roepcke, H.3    Bouillon, T.W.4    Hoeft, A.5
  • 15
    • 0034846487 scopus 로고    scopus 로고
    • Onset of propofol-induced burst suppression may be correctly detected as deepening of anaesthesia by approximate entropy but not by bispectral index
    • Bruhn J, Bouillon TW, Shafer SL: Onset of propofol-induced burst suppression may be correctly detected as deepening of anaesthesia by approximate entropy but not by bispectral index. Br J Anaesth 2001; 87:505-7
    • (2001) Br J Anaesth , vol.87 , pp. 505-507
    • Bruhn, J.1    Bouillon, T.W.2    Shafer, S.L.3
  • 16
    • 0034424760 scopus 로고    scopus 로고
    • Bispectral Index (BIS) and burst suppression: Revealing a part of the BIS algorithm
    • Bruhn J, Bouillon TW, Shafer SL: Bispectral Index (BIS) and burst suppression: Revealing a part of the BIS algorithm. J Clin Monit 2001; 16:593-6
    • (2001) J Clin Monit , vol.16 , pp. 593-596
    • Bruhn, J.1    Bouillon, T.W.2    Shafer, S.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.