메뉴 건너뛰기




Volumn 46, Issue 10, 2013, Pages 3898-3909

Electrical performances optimization of Photovoltaic Modules with FMECA approach

Author keywords

Dust effect; Failure mode; Maintenance; Module; Photovoltaic; PV efficiency; Renewable energy

Indexed keywords

CONDITION MONITORING; DUST; ENERGY CONVERSION; FAILURE MODES; MAINTENANCE; OPTIMIZATION; PHOTOVOLTAIC EFFECTS; SUN;

EID: 84883522357     PISSN: 02632241     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.measurement.2013.08.003     Document Type: Article
Times cited : (56)

References (68)
  • 1
    • 0020172572 scopus 로고
    • Performance of experimental terrestrial photovoltaic modules
    • S.E. Forman Performance of experimental terrestrial photovoltaic modules IEEE Transactions on Reliability R-31 1982 235 245
    • (1982) IEEE Transactions on Reliability , vol.31 R- , pp. 235-245
    • Forman, S.E.1
  • 2
    • 0020171813 scopus 로고
    • Photovoltaic module reliability improvement through application testing and failure analysis
    • L.N. Dumas, and A. Shumka Photovoltaic module reliability improvement through application testing and failure analysis IEEE Trans. Reliability R-31 1982 228 234
    • (1982) IEEE Trans. Reliability , vol.31 R- , pp. 228-234
    • Dumas, L.N.1    Shumka, A.2
  • 5
    • 79954600069 scopus 로고    scopus 로고
    • Reliability of large-scale grid-connected photovoltaic systems
    • G. Zini, C. Mangeant, and J. Merten Reliability of large-scale grid-connected photovoltaic systems Renewable Energy 36 9 2011 2334 2340
    • (2011) Renewable Energy , vol.36 , Issue.9 , pp. 2334-2340
    • Zini, G.1    Mangeant, C.2    Merten, J.3
  • 6
    • 0003966213 scopus 로고    scopus 로고
    • IEC 60050-191 Chapter 191: Dependability and quality of service
    • IEC 60050-191 - International Electrotechnical Vocabulary. Chapter 191: Dependability and quality of service.
    • International Electrotechnical Vocabulary
  • 8
    • 1942436339 scopus 로고    scopus 로고
    • Assessing the reliability and degradation of photovoltaic module performance parameters
    • E.L. Meyer, and E.E. van Dyk Assessing the reliability and degradation of photovoltaic module performance parameters IEEE Transactions on Reliability 53 1 2004 83 92
    • (2004) IEEE Transactions on Reliability , vol.53 , Issue.1 , pp. 83-92
    • Meyer, E.L.1    Van Dyk, E.E.2
  • 11
    • 84872019154 scopus 로고    scopus 로고
    • Reliability assessment of photovoltaic power systems: Review of current status and future perspectives
    • Peng Zhang, Wenyuan Li, Sherwin Li, Yang Wang, and Weidong Xiao Reliability assessment of photovoltaic power systems: review of current status and future perspectives Applied Energy 104 2013 822 833 < http://dx.doi.org/10.1016/j.apenergy.2012.12.010 >.
    • (2013) Applied Energy , vol.104 , pp. 822-833
    • Zhang, P.1    Li, W.2    Li, S.3    Wang, Y.4    Xiao, W.5
  • 12
    • 79954600069 scopus 로고    scopus 로고
    • Reliability of large-scale grid-connected photovoltaic systems
    • 10.1016/j.renene.2011.01.036
    • Gabriele Zini, Christophe Mangeant, and Jens Merten Reliability of large-scale grid-connected photovoltaic systems Renewable Energy 36 2011 2334 2340 10.1016/j.renene.2011.01.036
    • (2011) Renewable Energy , vol.36 , pp. 2334-2340
    • Zini, G.1    Mangeant, C.2    Merten, J.3
  • 13
    • 0019560667 scopus 로고
    • Reliability considerations in the design of solar photovoltaic power systems
    • L.H. Stember Reliability considerations in the design of solar photovoltaic power systems Solar Cells 3 3 1981 269 285
    • (1981) Solar Cells , vol.3 , Issue.3 , pp. 269-285
    • Stember, L.H.1
  • 14
    • 0024860263 scopus 로고
    • Reliability analysis of photovoltaics systems
    • M.A. Hamdy, M.E. Beshir, and S.E. Elmasry Reliability analysis of photovoltaics systems Applied Energy 33 4 1989 253 263
    • (1989) Applied Energy , vol.33 , Issue.4 , pp. 253-263
    • Hamdy, M.A.1    Beshir, M.E.2    Elmasry, S.E.3
  • 16
    • 0028262789 scopus 로고
    • Reliability of photovoltaic modules II. Interconnections and bypass diodes effects
    • N.A. Al-Rawi, M.M. Al-Kaisi, and D. Asfer Reliability of photovoltaic modules II. Interconnections and bypass diodes effects Solar Energy Materials and Solar Cells 31 4 1994 469 480
    • (1994) Solar Energy Materials and Solar Cells , vol.31 , Issue.4 , pp. 469-480
    • Al-Rawi, N.A.1    Al-Kaisi, M.M.2    Asfer, D.3
  • 17
    • 0029274478 scopus 로고
    • Reliabiity and economic analysis of a power generation system including a photovoltaic system
    • A. Jain, S.C. Tripathy, and R. Balasubramanian Reliabiity and economic analysis of a power generation system including a photovoltaic system Energy Conversion and Management 36 3 1995 183 189
    • (1995) Energy Conversion and Management , vol.36 , Issue.3 , pp. 183-189
    • Jain, A.1    Tripathy, S.C.2    Balasubramanian, R.3
  • 18
    • 0141506147 scopus 로고    scopus 로고
    • Reliability estimation for components of photovoltaic systems
    • P.R. Mishra, and J.C. Joshi Reliability estimation for components of photovoltaic systems Energy Conversion and Management 37 9 1996 1371 1382
    • (1996) Energy Conversion and Management , vol.37 , Issue.9 , pp. 1371-1382
    • Mishra, P.R.1    Joshi, J.C.2
  • 19
    • 0036462457 scopus 로고    scopus 로고
    • Reliability evaluation of solar photovoltaic arrays
    • N.K. Gautam, and N.D. Kaushika Reliability evaluation of solar photovoltaic arrays Solar Energy 72 2 2002 129 141
    • (2002) Solar Energy , vol.72 , Issue.2 , pp. 129-141
    • Gautam, N.K.1    Kaushika, N.D.2
  • 25
    • 42649139269 scopus 로고    scopus 로고
    • Alookback - Quality and reliability facilitator - FMEA
    • B. Gollomp Alookback - quality and reliability facilitator - FMEA IEEE Instrumentation and Measurement Magazine 11 2 2008 58 59
    • (2008) IEEE Instrumentation and Measurement Magazine , vol.11 , Issue.2 , pp. 58-59
    • Gollomp, B.1
  • 26
    • 5044243070 scopus 로고    scopus 로고
    • Using cost based FMEA to enhance reliability and serviceability
    • Seung J. Rhee, and Kosuke Ishii Using cost based FMEA to enhance reliability and serviceability Advanced Engineering Informatics 17 3-4 2003 179 188
    • (2003) Advanced Engineering Informatics , vol.17 , Issue.34 , pp. 179-188
    • Rhee, S.J.1    Ishii, K.2
  • 27
    • 74449085807 scopus 로고    scopus 로고
    • Parameter selection for health monitoring of electronic products
    • Sachin Kumar, Eli Dolev, and Michael Pecht Parameter selection for health monitoring of electronic products Microelectronics Reliability 50 2 2010 161 168
    • (2010) Microelectronics Reliability , vol.50 , Issue.2 , pp. 161-168
    • Kumar, S.1    Dolev, E.2    Pecht, M.3
  • 29
    • 44949269730 scopus 로고
    • Reliability diagnostics of electronic equipment
    • V. Soljacic, and M. Kosic Reliability diagnostics of electronic equipment Measurement 8 3 1990 141 144
    • (1990) Measurement , vol.8 , Issue.3 , pp. 141-144
    • Soljacic, V.1    Kosic, M.2
  • 31
    • 84944652830 scopus 로고    scopus 로고
    • The FMEDA approach to improve the safety assessment according to the IEC61508
    • ISSN: 00262714, DOI: 10.1016/j.microrel.2010.07.121
    • M. Catelani, L. Ciani, and V. Luongo The FMEDA approach to improve the safety assessment according to the IEC61508 Microelectronics Reliability 9-11 50 2010 1230 1235 ISSN: 00262714, DOI: 10.1016/j.microrel.2010.07.121
    • (2010) Microelectronics Reliability , vol.9-11 , Issue.50 , pp. 1230-1235
    • Catelani, M.1    Ciani, L.2    Luongo, V.3
  • 34
    • 77957100667 scopus 로고    scopus 로고
    • Impact of dust on solar photovoltaic (PV) performance: Research status, challenges and recommendations
    • Monto Mani, and Rohit Pillai Impact of dust on solar photovoltaic (PV) performance: research status, challenges and recommendations Renewable and Sustainable Energy Reviews 14 9 2010 3124 3131
    • (2010) Renewable and Sustainable Energy Reviews , vol.14 , Issue.9 , pp. 3124-3131
    • Mani, M.1    Pillai, R.2
  • 40
    • 33947115241 scopus 로고    scopus 로고
    • GSM-based monitoring and control of photovoltaic power generation
    • M. Gagliarducci, D.A. Lampasi, and L. Podestà GSM-based monitoring and control of photovoltaic power generation Measurement 40 3 2007 314 321
    • (2007) Measurement , vol.40 , Issue.3 , pp. 314-321
    • Gagliarducci, M.1    Lampasi, D.A.2    Podestà, L.3
  • 41
    • 84860449116 scopus 로고    scopus 로고
    • Design and implementation of a low-cost multi-channel temperature measurement system for photovoltaic modules
    • Rustu Eke, A. Sertap Kavasoglu, and Nese Kavasoglu Design and implementation of a low-cost multi-channel temperature measurement system for photovoltaic modules Measurement 45 6 2012 1499 1509
    • (2012) Measurement , vol.45 , Issue.6 , pp. 1499-1509
    • Eke, R.1    Sertap Kavasoglu, A.2    Kavasoglu, N.3
  • 44
    • 79959521598 scopus 로고    scopus 로고
    • Experimental investigation of the impact of airborne dust deposition on the performance of solar photovoltaic (PV) modules
    • Hai Jiang, Lu Lin, and Ke Sun Experimental investigation of the impact of airborne dust deposition on the performance of solar photovoltaic (PV) modules Atmospheric Environment 45 25 2011 4299 4304
    • (2011) Atmospheric Environment , vol.45 , Issue.25 , pp. 4299-4304
    • Jiang, H.1    Lin, L.2    Sun, K.3
  • 45
    • 0032216059 scopus 로고    scopus 로고
    • A new correlation for direct beam solar radiation reveived by photvoltaic panel with sand dust accumulated on its surface
    • A.Y. Al-Hasan A new correlation for direct beam solar radiation reveived by photvoltaic panel with sand dust accumulated on its surface Solar Energy 63 5 1998 323 333
    • (1998) Solar Energy , vol.63 , Issue.5 , pp. 323-333
    • Al-Hasan, A.Y.1
  • 46
    • 0033167151 scopus 로고    scopus 로고
    • Aeolian dust deposition on Photovoltaic solar cells: The effects of wind velocity and airborne dust concentration, on cell performance
    • D. Goossens, and E. Van Kerschaever Aeolian dust deposition on Photovoltaic solar cells: the effects of wind velocity and airborne dust concentration, on cell performance Solar Energy 66 4 1999 277 289
    • (1999) Solar Energy , vol.66 , Issue.4 , pp. 277-289
    • Goossens, D.1    Van Kerschaever, E.2
  • 47
    • 0035314721 scopus 로고    scopus 로고
    • Effect of dust accumulation on solar transmittance through glass covers of plate-type collectors
    • 10.1016/j.renene.2005.03.002
    • A.A. Hegazy Effect of dust accumulation on solar transmittance through glass covers of plate-type collectors Renewable Energy 22 2001 525 540 10.1016/j.renene.2005.03.002
    • (2001) Renewable Energy , vol.22 , pp. 525-540
    • Hegazy, A.A.1
  • 48
    • 53749092161 scopus 로고    scopus 로고
    • Implementation for maintaining the building-top GPV system
    • 10.1016/j.renene.2008.05.044
    • N. Watjanatepin Implementation for maintaining the building-top GPV system Renewable Energy 34 2009 444 449 10.1016/j.renene.2008.05.044
    • (2009) Renewable Energy , vol.34 , pp. 444-449
    • Watjanatepin, N.1
  • 49
    • 24644524127 scopus 로고    scopus 로고
    • Dynamic life cycle assessment (LCA) of renewable energy technologies
    • M. Pehnt Dynamic life cycle assessment (LCA) of renewable energy technologies Renewable energy 31 2006 55 71
    • (2006) Renewable Energy , vol.31 , pp. 55-71
    • Pehnt, M.1
  • 50
    • 64549153996 scopus 로고    scopus 로고
    • A practical field study of various solar cells on their performance in Malaysia
    • 10.1016/j.renene.2008.12.005
    • N. Amin, C.W. Lung, and K. Sopian A practical field study of various solar cells on their performance in Malaysia Renewable Energy 34 2009 1939 1946 10.1016/j.renene.2008.12.005
    • (2009) Renewable Energy , vol.34 , pp. 1939-1946
    • Amin, N.1    Lung, C.W.2    Sopian, K.3
  • 51
    • 68049137320 scopus 로고    scopus 로고
    • Estimation of the energy of a PV generator using artificial neural network
    • 10.1016/j.renene.2009.05.020
    • F. Almonacid, C. Rus, P.J. Pérez, and L. Hontoria Estimation of the energy of a PV generator using artificial neural network Renewable Energy 34 2009 2743 2750 10.1016/j.renene.2009.05.020
    • (2009) Renewable Energy , vol.34 , pp. 2743-2750
    • Almonacid, F.1    Rus, C.2    Pérez, P.J.3    Hontoria, L.4
  • 52
    • 79954595633 scopus 로고    scopus 로고
    • Self-cleaning and antireflective packaging glass for solar modules
    • 10.1016/j.renene.2011.02.017
    • L.K. Verma, M. Sakhuja, J. Son, A.J. Danner, H. Yang, H.C. Zeng, and C.S. Bhatia Self-cleaning and antireflective packaging glass for solar modules Renewable Energy 36 2011 2489 2493 10.1016/j.renene.2011.02.017
    • (2011) Renewable Energy , vol.36 , pp. 2489-2493
    • Verma, L.K.1    Sakhuja, M.2    Son, J.3    Danner, A.J.4    Yang, H.5    Zeng, H.C.6    Bhatia, C.S.7
  • 53
    • 79957439132 scopus 로고    scopus 로고
    • Environmental effects on a grid connected 900 W photovoltaic thin-film amorphous silicon system
    • 10.1016/j.renene.2010.06.010
    • T. Al Hanai, R.B. Hashim, L. El Chaar, and L.A. Lamont Environmental effects on a grid connected 900 W photovoltaic thin-film amorphous silicon system Renewable Energy 36 2011 2615 2622 10.1016/j.renene.2010.06.010
    • (2011) Renewable Energy , vol.36 , pp. 2615-2622
    • Al Hanai, T.1    Hashim, R.B.2    El Chaar, L.3    Lamont, L.A.4
  • 54
    • 79957460139 scopus 로고    scopus 로고
    • Systematic experimental study of the pollution deposition impact on the energy yield of photovoltaic installations
    • 10.1016/j.renene.2011.03.004
    • J.K. Kaldellis, P. Fragos, and M. Kapsali Systematic experimental study of the pollution deposition impact on the energy yield of photovoltaic installations Renewable Energy 36 2011 2717 2724 10.1016/j.renene.2011.03.004
    • (2011) Renewable Energy , vol.36 , pp. 2717-2724
    • Kaldellis, J.K.1    Fragos, P.2    Kapsali, M.3
  • 55
    • 84155172192 scopus 로고    scopus 로고
    • Control analysis for solar panel dust mitigation using an electric curtain
    • 10.1016/j.renene.2011.10.014
    • D. Qian, J.S. Marshall, and J. Frolik Control analysis for solar panel dust mitigation using an electric curtain Renewable Energy 41 2012 134 144 10.1016/j.renene.2011.10.014
    • (2012) Renewable Energy , vol.41 , pp. 134-144
    • Qian, D.1    Marshall, J.S.2    Frolik, J.3
  • 56
    • 84858294850 scopus 로고    scopus 로고
    • Spatio-temporal assessment of dust risk maps for solar energy systems using proxy data
    • 10.1016/j.renene.2011.12.005
    • Y. Charabi, and A. Gastli Spatio-temporal assessment of dust risk maps for solar energy systems using proxy data Renewable Energy 44 2012 23 31 10.1016/j.renene.2011.12.005
    • (2012) Renewable Energy , vol.44 , pp. 23-31
    • Charabi, Y.1    Gastli, A.2
  • 57
    • 84863113755 scopus 로고    scopus 로고
    • Understanding the effects of sand and dust accumulation on photovoltaic modules
    • N.S. Beattie, R.S. Moir, C. Chacko, G. Buffoni, S.H. Roberts, and N.M. Pearsall Understanding the effects of sand and dust accumulation on photovoltaic modules Renewable Energy 48 2012 448 452 < http://dx.doi.org/10.1016/j. renene.2012.06.007 >
    • (2012) Renewable Energy , vol.48 , pp. 448-452
    • Beattie, N.S.1    Moir, R.S.2    Chacko, C.3    Buffoni, G.4    Roberts, S.H.5    Pearsall, N.M.6
  • 58
    • 84858739966 scopus 로고    scopus 로고
    • Effect of dust, humidity and air velocity on efficiency of photovoltaic cell
    • 10.1016/j.rser.2012.02.012
    • S. Mekhilefa, R. Saidurb, and M. Kamalisarvestanib Effect of dust, humidity and air velocity on efficiency of photovoltaic cell Renewable and Sustainable Energy Reviews 16 2012 2920 2925 10.1016/j.rser.2012.02.012
    • (2012) Renewable and Sustainable Energy Reviews , vol.16 , pp. 2920-2925
    • Mekhilefa, S.1    Saidurb, R.2    Kamalisarvestanib, M.3
  • 62
    • 79953687168 scopus 로고    scopus 로고
    • Practical handbook of photovoltaics
    • Elsevier, Oxford
    • T. Markvart, L. Castañer, Practical handbook of photovoltaics. Fundamental and applications, Elsevier, Oxford, 2003.
    • (2003) Fundamental and Applications
    • Markvart, T.1
  • 63
    • 84883739844 scopus 로고    scopus 로고
    • http://ita.arpalombardia.it/ITA/qaria/doc-RichiestaDati.asp.
  • 65
    • 70449894606 scopus 로고    scopus 로고
    • An on-board device for condition based maintenance on inverted fed induction machines
    • IEEE, Digital Object Identifier: 10.1109/IMTC.2009.5168633
    • L. Cristaldi, M. Faifer, S. Toscani, M. Lazzaroni, An on-board device for condition based maintenance on inverted fed induction machines, in: Instrumentation and Measurement Technology Conference, I2MTC '09. IEEE, Digital Object Identifier: 10.1109/IMTC.2009.5168633, 2009, pp. 1177-1182.
    • (2009) Instrumentation and Measurement Technology Conference, I2MTC '09 , pp. 1177-1182
    • Cristaldi, L.1    Faifer, M.2    Toscani, S.3    Lazzaroni, M.4