메뉴 건너뛰기




Volumn 60, Issue 9, 2013, Pages 2504-2510

Accurate measurement of concurrent flexion-extension and internal-external rotations in smart knee prostheses

Author keywords

Anisotropic magneto resistive (AMR) sensors; input selection; instrumented prosthesis; knee rotations

Indexed keywords

ANISOTROPY; ARTIFICIAL LIMBS; ERRORS; KNEE PROSTHESES; MAGNETOS; MEASUREMENTS; NEURAL NETWORKS; PHYSIOLOGICAL MODELS; REGRESSION ANALYSIS; ROTATION; SENSORS;

EID: 84883011967     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2013.2259489     Document Type: Article
Times cited : (9)

References (36)
  • 2
    • 0029310686 scopus 로고
    • Kinetic analysis of the lower limbs during walking: What information can be gained from a three-dimensional model?
    • J. J. Eng and D. A. Winter, "Kinetic analysis of the lower limbs during walking: What information can be gained from a three-dimensional model?," J. Biomech., vol. 28, no. 6, pp. 753-758, 1995.
    • (1995) J. Biomech , vol.28 , Issue.6 , pp. 753-758
    • Eng, J.J.1    Winter, D.A.2
  • 3
    • 10744225725 scopus 로고    scopus 로고
    • A Three-Dimensional Kinematic and Dynamic Study of the Lower Limb during the Stance Phase of Gait Using an Homogeneous Matrix Approach
    • DOI 10.1109/TBME.2003.820357
    • N. Doriot and L. Ch̀eze, "A three-dimensional kinematic and dynamic study of the lower limb during the stance phase of gait using an homogeneous matrix approach," IEEE Trans. Biomed. Eng., vol. 51, no. 1, pp. 21-27, Jan. 2004. (Pubitemid 38009959)
    • (2004) IEEE Transactions on Biomedical Engineering , vol.51 , Issue.1 , pp. 21-27
    • Doriot, N.1    Cheze, L.2
  • 4
    • 16544389145 scopus 로고    scopus 로고
    • A 3D generic inverse dynamic method using wrench notation and quaternion algebra
    • R.Dumas, R.Aissaoui, and J. A. de Guise, "A 3D generic inverse dynamic method using wrench notation and quaternion algebra," Comput. Meth. Biomech. Biomed. Eng., vol. 7, no. 3, pp. 159-166, 2004.
    • (2004) Comput. Meth. Biomech. Biomed. Eng , vol.7 , Issue.3 , pp. 159-166
    • Dumas, R.1    Aissaoui, R.2    De Guise, J.A.3
  • 5
    • 33847611229 scopus 로고    scopus 로고
    • 3D inverse dynamics in non-orthonormal segment coordinate system
    • DOI 10.1007/s11517-006-0156-8
    • R. Dumas and L. Ch̀eze, "3D inverse dynamics in non-orthonormal segment coordinate system," Med. Bio. Eng. Comput., vol. 45, no. 3, pp. 315-322, 2007. (Pubitemid 46359455)
    • (2007) Medical and Biological Engineering and Computing , vol.45 , Issue.3 , pp. 315-322
    • Dumas, R.1    Cheze, L.2
  • 6
    • 19644398653 scopus 로고    scopus 로고
    • Human movement analysis using stereophotogrammetry Part 3. Soft tissue artifact assessment and compensation
    • DOI 10.1016/j.gaitpost.2004.05.002
    • A. Leardini, L. Chiari, U. Della Croce, and A. Cappozzo, "Human movement analysis using stereophotogrammetry Part 3. Soft tissue artifact assessment and compensation," Gait Posture, vol. 21, pp. 212-225, 2005. (Pubitemid 41556840)
    • (2005) Gait and Posture , vol.21 , Issue.2 , pp. 212-225
    • Leardini, A.1    Chiari, A.2    Della Croce, U.3    Cappozzo, A.4
  • 7
    • 33748304160 scopus 로고    scopus 로고
    • Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo
    • DOI 10.1016/j.gaitpost.2005.04.012, PII S0966636205001700
    • D. L. Benoit, D. K. Ramsey, M. Lamontagne, L. Xu, P. Wretenberg, and P. Renstrom, "Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo," Gait Posture, vol. 24, no. 2, pp. 152-164, 2006. (Pubitemid 44332252)
    • (2006) Gait and Posture , vol.24 , Issue.2 , pp. 152-164
    • Benoit, D.L.1    Ramsey, D.K.2    Lamontagne, M.3    Xu, L.4    Wretenberg, P.5    Renstrom, P.6
  • 8
    • 40249094435 scopus 로고    scopus 로고
    • Ambulatory measurement of 3D knee joint angle
    • J. Favre, B. M. Jolles, R. Aissaoui, and K. Aminian, "Ambulatory measurement of 3D knee joint angle," J. Biomech., vol. 41, pp. 1029-1035, 2008.
    • (2008) J. Biomech , vol.41 , pp. 1029-1035
    • Favre, J.1    Jolles, B.M.2    Aissaoui, R.3    Aminian, K.4
  • 9
    • 23844513274 scopus 로고    scopus 로고
    • A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes
    • DOI 10.1109/TBME.2005.851475
    • H. Dejnabadi, B. M. Jolles, and K Aminian, "A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes," IEEE Trans. Biomed. Eng., vol. 52, no. 8, pp. 1478-1484, Aug. 2005. (Pubitemid 41169542)
    • (2005) IEEE Transactions on Biomedical Engineering , vol.52 , Issue.8 , pp. 1478-1484
    • Dejnabadi, H.1    Jolles, B.M.2    Aminian, K.3
  • 10
    • 79551543214 scopus 로고    scopus 로고
    • Ambulatory estimation of knee-joint kinematics in anatomical coordinate system using accelerometers and magnetometers
    • Feb.
    • L. Kun, Y. Inoue, K. Shibata, and C. Enguo, "Ambulatory estimation of knee-joint kinematics in anatomical coordinate system using accelerometers and magnetometers," IEEE Trans. Biomed. Eng., vol. 58, no. 2, pp. 435-442, Feb. 2011.
    • (2011) IEEE Trans. Biomed. Eng , vol.58 , Issue.2 , pp. 435-442
    • Kun, L.1    Inoue, Y.2    Shibata, K.3    Enguo, C.4
  • 11
    • 34250788516 scopus 로고    scopus 로고
    • A magnetometer-based approach for studying human movements
    • DOI 10.1109/TBME.2007.890742
    • S. Bonnet and R. H́eliot, "A magnetometer-based approach for studying human movements," IEEE Trans. Biomed. Eng., vol. 54, no. 7, pp. 1353-1355, Jul. 2007. (Pubitemid 46956955)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.7 , pp. 1353-1355
    • Bonnet, S.1    Heliot, R.2
  • 12
    • 34247345871 scopus 로고    scopus 로고
    • Ambulatory position and orientation tracking fusing magnetic and inertial sensing
    • DOI 10.1109/TBME.2006.889184, 15
    • D. Roetenberg, P. J. Slycke, and P. H. Veltink, "Ambulatory position and orientation tracking fusing magnetic and inertial sensing," IEEE Trans. Biomed. Eng., vol. 54, no. 5, pp. 883-890, May 2007. (Pubitemid 46628581)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.5 , pp. 883-890
    • Roetenberg, D.1    Slycke, P.J.2    Veltink, P.H.3
  • 13
    • 0033678224 scopus 로고    scopus 로고
    • Three-dimensional knee analyzer validation by simple fluoroscopic study
    • S. Ganjikia, N. Duval, L. H. Yahia, and J. de Guise, "Three- dimensional knee analyzer validation by simple fluoroscopic study," Knee, vol. 7, pp. 221-231, 2000.
    • (2000) Knee , vol.7 , pp. 221-231
    • Ganjikia, S.1    Duval, N.2    Yahia, L.H.3    De Guise, J.4
  • 14
    • 70349449601 scopus 로고    scopus 로고
    • Functional calibration procedure for 3D knee joint angle description using inertial sensors
    • J. Favre, R. Aissaoui, B. M. Jolles, J. A. De Guise, and K. Aminian, "Functional calibration procedure for 3D knee joint angle description using inertial sensors," J. Biomech., vol. 42, pp. 2330-2335, 2009.
    • (2009) J. Biomech , vol.42 , pp. 2330-2335
    • Favre, J.1    Aissaoui, R.2    Jolles, B.M.3    De Guise, J.A.4    Aminian, K.5
  • 15
    • 0026848920 scopus 로고
    • Threedimensional kinematics of the human knee during walking
    • M. A. Lafortune, P. R. Cavanagh, H. J. Sommer, and A. Kalenak, "Threedimensional kinematics of the human knee during walking," J. Biomech., vol. 25, no. 4, pp. 347-357, 1992.
    • (1992) J. Biomech , vol.25 , Issue.4 , pp. 347-357
    • Lafortune, M.A.1    Cavanagh, P.R.2    Sommer, H.J.3    Kalenak, A.4
  • 16
    • 50449108996 scopus 로고    scopus 로고
    • Precision assessment of model-based RSAfor a total knee prosthesis in a biplanar set-up
    • C. Trozzi, B. L. Kaptein, E. H. Garling, T. Shelyakova, A. Russo, L. Bragonzoni, and S. Martelli, "Precision assessment of model-based RSAfor a total knee prosthesis in a biplanar set-up," knee, vol. 15, pp. 396-402, 2008.
    • (2008) Knee , vol.15 , pp. 396-402
    • Trozzi, C.1    Kaptein, B.L.2    Garling, E.H.3    Shelyakova, T.4    Russo, A.5    Bragonzoni, L.6    Martelli, S.7
  • 18
    • 54449093932 scopus 로고    scopus 로고
    • In vivo knee forces during recreation and exercise after knee arthroplasty
    • D. D. D'Lima, N. Steklov, S. Patil, and C. W. Colwell, "In vivo knee forces during recreation and exercise after knee arthroplasty," Clin. Orthop. Related Res., vol. 466, pp. 2605-2611, 2008.
    • (2008) Clin. Orthop. Related Res , vol.466 , pp. 2605-2611
    • D'Lima, D.D.1    Steklov, N.2    Patil, S.3    Colwell, C.W.4
  • 19
    • 79951601209 scopus 로고    scopus 로고
    • Design and test of an autonomous sensor for force measurements in human knee implants
    • D. Crescini, E. Sardini, and M. Serpelloni, "Design and test of an autonomous sensor for force measurements in human knee implants," Sens. Actuators A Phys., vol. 166, pp. 1-8, 2011.
    • (2011) Sens. Actuators A Phys , vol.166 , pp. 1-8
    • Crescini, D.1    Sardini, E.2    Serpelloni, M.3
  • 21
    • 84892566385 scopus 로고    scopus 로고
    • Instrumented knee prosthesis for force and kinematics measurements
    • to be published DOI:10.1109/TASE.2012.2226030
    • A. Arami et al., "Instrumented knee prosthesis for force and kinematics measurements," IEEE Trans. Autom. Sci. Eng., to be published. Available: http://ieeexplore.ieee.org/xpls/abs-all.jsp?arnumber=6410368=1. DOI:10.1109/TASE.2012.2226030.
    • IEEE Trans. Autom. Sci. Eng.
    • Arami, A.1
  • 22
    • 84863595467 scopus 로고    scopus 로고
    • Accurate internal-external rotation measurement in total knee prostheses: A magnetic solution
    • A. Arami, J. Miehlbradt, and K. Aminian, "Accurate internal-external rotation measurement in total knee prostheses: A magnetic solution," J. Biomech., vol. 45, pp. 2023-2027, 2012.
    • (2012) J. Biomech , vol.45 , pp. 2023-2027
    • Arami, A.1    Miehlbradt, J.2    Aminian, K.3
  • 23
    • 84860879612 scopus 로고    scopus 로고
    • A randomised controlled clinical trial and gait analysis of fixed-and mobile-bearing total knee replacements with a five-year follow-up
    • B. M. Jolles et al., "A randomised controlled clinical trial and gait analysis of fixed-and mobile-bearing total knee replacements with a five-year follow-up," J. Bone Joint Surg. Br., vol. 94, pp. 648-655, 2012.
    • (2012) J. Bone Joint Surg. Br , vol.94 , pp. 648-655
    • Jolles, B.M.1
  • 24
    • 0020433171 scopus 로고
    • The influence of total knee-replacement design on walking and stair-climbing
    • T. P. Andriacchi, J. O. Galante, and R. W. Fermier, "The influence of total knee-replacement design on walking and stair-climbing," J. Bone Joint Surg. Amer., vol. 64, no. 9, pp. 1328-1335, 1982. (Pubitemid 13169602)
    • (1982) Journal of Bone and Joint Surgery - Series A , vol.64 , Issue.9 , pp. 1328-1335
    • Andriacchi, T.P.1    Galante, J.O.2    Fermier, R.W.3
  • 25
    • 26044476613 scopus 로고    scopus 로고
    • A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years
    • DOI 10.2106/JBJS.D.02221
    • S. Bhan, R. Malhotra, E. K. Kiran, S. Shukla, and M. Bijjawara, "A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years," J. Bone Joint Surg. Amer., vol. 87, no. 10, pp. 2290-2296, 2005. (Pubitemid 41407556)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.10 , pp. 2290-2296
    • Bhan, S.1    Malhotra, R.2    Kiran, E.K.3    Shukla, S.4    Bijjawara, M.5
  • 26
    • 0018087555 scopus 로고
    • The mechanics of the knee and prosthesis design
    • J. Goodfellowand J. O'Conner, "The mechanics of the knee and prosthesis design," J. Bone Joint Surg. Br., vol. 60-B, no. 3, pp. 358-369, 1978.
    • (1978) J. Bone Joint Surg. Br. , vol.3 , pp. 358-369
    • Goodfellowand, J.1    O'Conner, J.2
  • 27
    • 0035117514 scopus 로고    scopus 로고
    • Survival analysis of cemented Press-Fit Condylar total knee arthroplasty
    • DOI 10.1054/arth.2001.20254
    • F. M. Khaw, L. M. Kirk, and P. J. Gregg, "Survival analysis of cemented press-fit condylar total knee arthroplasty," J. Arthroplasty, vol. 16, pp. 161-167, 2001. (Pubitemid 32163842)
    • (2001) Journal of Arthroplasty , vol.16 , Issue.2 , pp. 161-167
    • Khaw, F.-M.1    Kirk, L.M.G.2    Gregg, P.J.3
  • 28
    • 42749089846 scopus 로고    scopus 로고
    • Fixedbearing versus mobile-bearing total knee arthroplasty: A prospective randomized, clinical and radiological study with mid-term results at 7 years
    • A. L̈adermann, A. L̈ubbeke, R. Stern, N. Riand, and D. Fritschy, "Fixedbearing versus mobile-bearing total knee arthroplasty: A prospective randomized, clinical and radiological study with mid-term results at 7 years," knee, vol. 15, pp. 206-210, 2008.
    • (2008) Knee , vol.15 , pp. 206-210
    • L̈adermann, A.1    L̈ubbeke, A.2    Stern, R.3    Riand, N.4    Fritschy, D.5
  • 29
    • 77449133451 scopus 로고    scopus 로고
    • Fixed-versusmobilebearing total knee arthroplasty in Indian patients
    • A.Vasdev, S.Kumar,G. Chadha, and S. P. Mandal, "Fixed- versusmobilebearing total knee arthroplasty in Indian patients," J. Orthop. Surg., vol. 17, no. 2, pp. 179-182, 2009.
    • (2009) J. Orthop. Surg , vol.17 , Issue.2 , pp. 179-182
    • Vasdev, A.1    Kumar, S.2    Chadha, G.3    Mandal, S.P.4
  • 30
    • 84882971092 scopus 로고    scopus 로고
    • Soft tissue artifact assessment during treadmill walking in subjects with total knee arthroplasty
    • submitted for publication
    • A. Barre, J.-P. Thiran, B. M. Jolles, N. Theumann, and K. Aminian, "Soft tissue artifact assessment during treadmill walking in subjects with total knee arthroplasty," IEEE Trans. Biomed. Eng., submitted for publication.
    • IEEE Trans. Biomed. Eng
    • Barre, A.1    Thiran, J.-P.2    Jolles, B.M.3    Theumann, N.4    Aminian, K.5
  • 32
    • 0028468293 scopus 로고
    • Using mutual information for selecting features in supervised neural net learning
    • Jul
    • R. Battiti, "Using mutual information for selecting features in supervised neural net learning," IEEE Trans. Neural Netw., vol. 5, no. 4, pp. 537-550, Jul. 1994.
    • (1994) IEEE Trans. Neural Netw , vol.5 , Issue.4 , pp. 537-550
    • Battiti, R.1
  • 33
    • 24344458137 scopus 로고    scopus 로고
    • Feature selection based on mutual information: Criteria of Max-Dependency, Max-Relevance, and Min-Redundancy
    • DOI 10.1109/TPAMI.2005.159
    • H. Peng, F. Long, and C. Ding, "Feature selection based on mutual information: Criteria of max-dependency, max-relevance and minredundancy," IEEE Trans. Pattern Anal. Mach. Intell., vol. 27, no. 8, pp. 1226-1238, Aug. 2005. (Pubitemid 41245053)
    • (2005) IEEE Transactions on Pattern Analysis and Machine Intelligence , vol.27 , Issue.8 , pp. 1226-1238
    • Peng, H.1    Long, F.2    Ding, C.3
  • 34
    • 33846669123 scopus 로고    scopus 로고
    • Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants
    • DOI 10.1109/TBME.2006.886857, 9
    • F. Graichen, R. Arnold, A. Rohlmann, and G. Bergmann, "Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants," IEEE Trans. Biomed. Eng., vol. 54, no. 2, pp. 253-261, Feb. 2007. (Pubitemid 46188168)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.2 , pp. 253-261
    • Graichen, F.1    Arnold, R.2    Rohlmann, A.3    Bergmann, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.