Volumn 41, Issue 5, 2008, Pages 1029-1035

Ambulatory measurement of 3D knee joint angle

Author keywords

3D kinematics; Accelerometer; Gyroscope; Inertial sensors; Knee; Orientation measurement

Indexed keywords

ACCELEROMETERS; BIOMECHANICS; GYROSCOPES; KINEMATICS; MEAN SQUARE ERROR;

EID: 40249094435     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2007.12.003     Document Type: Article
Times cited : (259)

References (28)
  • 2
    • 40249100724 scopus 로고    scopus 로고
    • Bachman, E., 2000. Inertial and magnetic tracking of limb segment orientation for inserting humans in synthetic environments. Ph.D. Thesis, Naval Postgraduate School, Monterey, CA, p. 178.
    • Bachman, E., 2000. Inertial and magnetic tracking of limb segment orientation for inserting humans in synthetic environments. Ph.D. Thesis, Naval Postgraduate School, Monterey, CA, p. 178.
  • 4
    • 84908219488 scopus 로고
    • Statistical-methods for assessing agreement between 2 methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical-methods for assessing agreement between 2 methods of clinical measurement. The Lancet 1 (1986) 307-310
    • (1986) The Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 0031952972 scopus 로고    scopus 로고
    • Ambulatory accelerometry to quantify motor behaviour in patients after failed back surgery: a validation study
    • Bussmann J.B.J., van de Laar Y.M., Neeleman M.P., and Stam H.J. Ambulatory accelerometry to quantify motor behaviour in patients after failed back surgery: a validation study. Pain 74 (1998) 153-161
    • (1998) Pain , vol.74 , pp. 153-161
    • Bussmann, J.B.J.1    van de Laar, Y.M.2    Neeleman, M.P.3    Stam, H.J.4
  • 6
    • 0031635738 scopus 로고    scopus 로고
    • Canan, S., Ozbay, Y., Karlik, B., 1998. A method for removing low varying frequency trend from ECG signal. In: IEEE Biomedical Engineering Days, Istanbul, Turkey, pp. 144-146.
    • Canan, S., Ozbay, Y., Karlik, B., 1998. A method for removing low varying frequency trend from ECG signal. In: IEEE Biomedical Engineering Days, Istanbul, Turkey, pp. 144-146.
  • 7
    • 0029311073 scopus 로고
    • Position and orientation in-space of bones during movement-anatomical frame definition and determination
    • Cappozzo A., Catani F., Della Croce U., and Leardini A. Position and orientation in-space of bones during movement-anatomical frame definition and determination. Clinical Biomechanics 10 (1995) 171-178
    • (1995) Clinical Biomechanics , vol.10 , pp. 171-178
    • Cappozzo, A.1    Catani, F.2    Della Croce, U.3    Leardini, A.4
  • 8
    • 0033708454 scopus 로고    scopus 로고
    • Caruso, M.J., 2000. Applications of magnetic sensors for low cost compass systems. In: IEEE Position Location and Navigation Symposium, San Diego, CA, USA, pp. 177-184.
    • Caruso, M.J., 2000. Applications of magnetic sensors for low cost compass systems. In: IEEE Position Location and Navigation Symposium, San Diego, CA, USA, pp. 177-184.
  • 9
    • 33744494032 scopus 로고    scopus 로고
    • Six DOF in vivo kinematics of the ankle joint complex: application of a combined dual-orthogonal fluoroscopic and magnetic resonance imaging technique
    • de Asla R.J., Wan L., Rubash H.E., and Li G. Six DOF in vivo kinematics of the ankle joint complex: application of a combined dual-orthogonal fluoroscopic and magnetic resonance imaging technique. Journal of Orthopaedic Research 24 (2006) 1019-1027
    • (2006) Journal of Orthopaedic Research , vol.24 , pp. 1019-1027
    • de Asla, R.J.1    Wan, L.2    Rubash, H.E.3    Li, G.4
  • 10
    • 0032994668 scopus 로고    scopus 로고
    • Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles
    • Della Croce U., Cappozzo A., and Kerrigan D.C. Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles. Medical and Biological Engineering and Computing 37 (1999) 155-161
    • (1999) Medical and Biological Engineering and Computing , vol.37 , pp. 155-161
    • Della Croce, U.1    Cappozzo, A.2    Kerrigan, D.C.3
  • 11
    • 33745711958 scopus 로고    scopus 로고
    • A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries
    • Favre J., Luthi F., Jolles B.M., Siegrist O., Najafi B., and Aminian K. A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries. Knee Surgery Sports Traumatology Arthroscopy 14 (2006) 592-604
    • (2006) Knee Surgery Sports Traumatology Arthroscopy , vol.14 , pp. 592-604
    • Favre, J.1    Luthi, F.2    Jolles, B.M.3    Siegrist, O.4    Najafi, B.5    Aminian, K.6
  • 12
    • 33744510704 scopus 로고    scopus 로고
    • Quaternion-based fusion of gyroscopes and accelerometers to improve 3D angle measurement
    • Favre J., Jolles B.M., Siegrist O., and Aminian K. Quaternion-based fusion of gyroscopes and accelerometers to improve 3D angle measurement. Electronics Letters 42 (2006) 612-614
    • (2006) Electronics Letters , vol.42 , pp. 612-614
    • Favre, J.1    Jolles, B.M.2    Siegrist, O.3    Aminian, K.4
  • 14
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of 3-dimensional motions-application to the knee
    • Grood E.S., and Suntay W.J. A joint coordinate system for the clinical description of 3-dimensional motions-application to the knee. Journal of Biomechanical Engineering-Transactions of the ASME 105 (1983) 136-144
    • (1983) Journal of Biomechanical Engineering-Transactions of the ASME , vol.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 15
    • 3042624688 scopus 로고    scopus 로고
    • Harada, T., Uchini, H., Mori, T., Sato, T., 2004. Portable absolute orientation estimation device with wireless network under accelerated situation. In: IEEE International Conference on Robotics Automation, vol. 2, New Orleans, LA, USA, pp. 1412-1417.
    • Harada, T., Uchini, H., Mori, T., Sato, T., 2004. Portable absolute orientation estimation device with wireless network under accelerated situation. In: IEEE International Conference on Robotics Automation, vol. 2, New Orleans, LA, USA, pp. 1412-1417.
  • 16
    • 0344950357 scopus 로고    scopus 로고
    • Movement parameters that distinguish between voluntary movements and levodopa-induced dyskinesia in Parkinson's disease
    • Keijsers N.L.W., Horstink M., and Gielen S. Movement parameters that distinguish between voluntary movements and levodopa-induced dyskinesia in Parkinson's disease. Human Movement Science 22 (2003) 67-89
    • (2003) Human Movement Science , vol.22 , pp. 67-89
    • Keijsers, N.L.W.1    Horstink, M.2    Gielen, S.3
  • 17
    • 12344305531 scopus 로고    scopus 로고
    • Real-time measurement of patellofemoral kinematics in asymptomatic subjects
    • Laprade J., and Lee R. Real-time measurement of patellofemoral kinematics in asymptomatic subjects. Knee 12 (2005) 63-72
    • (2005) Knee , vol.12 , pp. 63-72
    • Laprade, J.1    Lee, R.2
  • 18
    • 0033081250 scopus 로고    scopus 로고
    • Kinematics of the human ankle complex in passive flexion; a single degree of freedom system
    • Leardini A., O'Connor J.J., Catani F., and Giannini S. Kinematics of the human ankle complex in passive flexion; a single degree of freedom system. Journal of Biomechanics 32 (1999) 111-118
    • (1999) Journal of Biomechanics , vol.32 , pp. 111-118
    • Leardini, A.1    O'Connor, J.J.2    Catani, F.3    Giannini, S.4
  • 20
    • 0040165127 scopus 로고    scopus 로고
    • The effects of metals and interfering fields on electromagnetic trackers
    • Nixon M.A., McCallum B.C., Fright W.R., and Price N.B. The effects of metals and interfering fields on electromagnetic trackers. Presence 7 (1998) 204-217
    • (1998) Presence , vol.7 , pp. 204-217
    • Nixon, M.A.1    McCallum, B.C.2    Fright, W.R.3    Price, N.B.4
  • 21
    • 0025741099 scopus 로고
    • On the estimation of joint kinematics during gait
    • Ramakrishnan H.K., and Kadaba M.P. On the estimation of joint kinematics during gait. Journal of Biomechanics 24 (1991) 969-977
    • (1991) Journal of Biomechanics , vol.24 , pp. 969-977
    • Ramakrishnan, H.K.1    Kadaba, M.P.2
  • 22
    • 40249084641 scopus 로고    scopus 로고
    • Roetenberg, D., 2006. Inertial and magnetic sensing of human motion. Ph.D. Thesis, Twente University, Enschede, The Netherlands, p. 126.
    • Roetenberg, D., 2006. Inertial and magnetic sensing of human motion. Ph.D. Thesis, Twente University, Enschede, The Netherlands, p. 126.
  • 25
    • 0028329682 scopus 로고
    • Measurements of static magnetic fields in homes in the UK and their implication for epidemiological studies of exposure to alternating magnetic fields
    • Swanson J. Measurements of static magnetic fields in homes in the UK and their implication for epidemiological studies of exposure to alternating magnetic fields. Journal of Radiological Protection 14 (1994) 67-75
    • (1994) Journal of Radiological Protection , vol.14 , pp. 67-75
    • Swanson, J.1
  • 26
    • 78049249013 scopus 로고    scopus 로고
    • Van Bogard, J., 2000. Motion analysis technologies. In: IEEE International Conference on Pediatric Gait, Chicago, IL, USA, pp. 166-172.
    • Van Bogard, J., 2000. Motion analysis technologies. In: IEEE International Conference on Pediatric Gait, Chicago, IL, USA, pp. 166-172.
  • 27
    • 0029114425 scopus 로고
    • ISB recommendations for standardization in the reporting of kinematic data
    • Wu G., and Cavanagh P.R. ISB recommendations for standardization in the reporting of kinematic data. Journal of Biomechanics 28 (1995) 1257-1260
    • (1995) Journal of Biomechanics , vol.28 , pp. 1257-1260
    • Wu, G.1    Cavanagh, P.R.2
  • 28
    • 2942690285 scopus 로고    scopus 로고
    • A real-time articulated human motion tracking using tri-axis inertial/magnetic sensors package
    • Zhu R., and Zhou Z.Y. A real-time articulated human motion tracking using tri-axis inertial/magnetic sensors package. IEEE Transactions on Neural Systems and Rehabilitation Engineering 12 (2004) 295-302
    • (2004) IEEE Transactions on Neural Systems and Rehabilitation Engineering , vol.12 , pp. 295-302
    • Zhu, R.1    Zhou, Z.Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.