1
-
-
0023032866
-
MR artifacts: A review
-
Bellon EM, Haacke EM, Coleman PE, Sacco DC, Steiger DA, Gangarosa RE,. MR artifacts: a review. AJR Am J Roentgenol 1986; 147: 1271-1281. (Pubitemid 17185046)
-
(1986)
American Journal of Roentgenology
, vol.147
, Issue.6
, pp. 1271-1281
-
-
Bellon, E.M.1
Haacke, E.M.2
Coleman, P.E.3
-
2
-
-
0032737049
-
MR imaging artifacts. Challenges and solutions
-
Mirowitz SA,. MR imaging artifacts. Challenges and solutions. Magn Reson Imaging Clin N Am 1999; 7: 717-732.
-
(1999)
Magn Reson Imaging Clin N Am
, vol.7
, pp. 717-732
-
-
Mirowitz, S.A.1
-
4
-
-
32544439888
-
AAPM/RSNA physics tutorial for residents: MR artifacts, safety, and quality control
-
DOI 10.1148/rg.261055134
-
Zhuo J, Gullapalli RP,. AAPM/RSNA physics tutorial for residents: MR artifacts, safety, and quality control. Radiographics 2006; 26: 275-297. (Pubitemid 43235018)
-
(2006)
Radiographics
, vol.26
, Issue.1
, pp. 275-297
-
-
Zhuo, J.1
Gullapalli, R.P.2
-
5
-
-
34247893954
-
Artifacts in body MR imaging: Their appearance and how to eliminate them
-
DOI 10.1007/s00330-006-0470-4
-
Stadler A, Schima W, Ba-Ssalamah A, Kettenbach J, Eisenhuber E,. Artifacts in body MR imaging: their appearance and how to eliminate them. Eur Radiol 2007; 17: 1242-1255. (Pubitemid 46691954)
-
(2007)
European Radiology
, vol.17
, Issue.5
, pp. 1242-1255
-
-
Stadler, A.1
Schima, W.2
Ba-Ssalamah, A.3
Kettenbach, J.4
Eisenhuber, E.5
-
6
-
-
79958071014
-
An image-based approach to understanding the physics of MR artifacts
-
Morelli JN, Runge VM, Ai F, et al. An image-based approach to understanding the physics of MR artifacts. Radiographics 2011; 31: 849-866.
-
(2011)
Radiographics
, vol.31
, pp. 849-866
-
-
Morelli, J.N.1
Runge, V.M.2
Ai, F.3
-
7
-
-
0025832805
-
Rapid in vivo proton shimming
-
Schneider E, Glover G,. Rapid in vivo proton shimming. Magn Reson Med 1991; 18: 335-347.
-
(1991)
Magn Reson Med
, vol.18
, pp. 335-347
-
-
Schneider, E.1
Glover, G.2
-
8
-
-
0029266887
-
Unsuppressed fat in the right anterior diaphragmatic region on fat-suppressed T2-weighted fast spin-echo MR images
-
Yoshimitsu K, Varma DG, Jackson EF,. Unsuppressed fat in the right anterior diaphragmatic region on fat-suppressed T2-weighted fast spin-echo MR images. J Magn Reson Imaging 1995; 5: 145-149.
-
(1995)
J Magn Reson Imaging
, vol.5
, pp. 145-149
-
-
Yoshimitsu, K.1
Varma, D.G.2
Jackson, E.F.3
-
9
-
-
0033707950
-
Origin of a signal intensity loss artifact in fat-saturation MR imaging
-
Axel L, Kolman L, Charafeddine R, Hwang SN, Stolpen AH,. Origin of a signal intensity loss artifact in fat-saturation MR imaging. Radiology 2000; 217: 911-915.
-
(2000)
Radiology
, vol.217
, pp. 911-915
-
-
Axel, L.1
Kolman, L.2
Charafeddine, R.3
Hwang, S.N.4
Stolpen, A.H.5
-
10
-
-
0026648242
-
Fat-suppression failure artifacts simulating pathology on frequency-selective fat-suppression MR images of the head and neck
-
Anzai Y, Lufkin RB, Jabour BA, Hanafee WN,. Fat-suppression failure artifacts simulating pathology on frequency-selective fat-suppression MR images of the head and neck. AJNR Am J Neuroradiol 1992; 13: 879-884.
-
(1992)
AJNR Am J Neuroradiol
, vol.13
, pp. 879-884
-
-
Anzai, Y.1
Lufkin, R.B.2
Jabour, B.A.3
Hanafee, W.N.4
-
11
-
-
0034546352
-
Suppression of intravascular signal on fat-saturated contrast-enhanced thoracic MR arteriograms
-
Siegelman ES, Charafeddine R, Stolpen AH, Axel L,. Suppression of intravascular signal on fat-saturated contrast-enhanced thoracic MR arteriograms. Radiology 2000; 217: 115-118. (Pubitemid 33097586)
-
(2000)
Radiology
, vol.217
, Issue.1
, pp. 115-118
-
-
Siegelman, E.S.1
Charafeddine, R.2
Stolpen, A.H.3
Axel, L.4
-
12
-
-
0021132985
-
Simple proton spectroscopic imaging
-
Dixon WT,. Simple proton spectroscopic imaging. Radiology 1984; 153: 189-194. (Pubitemid 14043406)
-
(1984)
Radiology
, vol.153
, Issue.1
, pp. 189-194
-
-
Dixon, W.T.1
-
13
-
-
3543083453
-
Breath-hold water and fat imaging using a dual-echo two-point dixon technique with an efficient and robust phase-correction algorithm
-
DOI 10.1002/mrm.20146
-
Ma J,. Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm. Magn Reson Med 2004; 52: 415-419. (Pubitemid 39025289)
-
(2004)
Magnetic Resonance in Medicine
, vol.52
, Issue.2
, pp. 415-419
-
-
Ma, J.1
-
14
-
-
23244463430
-
Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): Application with fast spin-echo imaging
-
DOI 10.1002/mrm.20624
-
Reeder SB, Pineda AR, Wen Z, et al. Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging. Magn Reson Med 2005; 54: 636-644. (Pubitemid 41233758)
-
(2005)
Magnetic Resonance in Medicine
, vol.54
, Issue.3
, pp. 636-644
-
-
Reeder, S.B.1
Pineda, A.R.2
Wen, Z.3
Shimakawa, A.4
Yu, H.5
Brittain, J.H.6
Gold, G.E.7
Beaulieu, C.H.8
Pelc, N.T.9
-
15
-
-
0030900987
-
Design of adiabatic pulses for fat-suppression using analytic solutions of the bloch equation
-
Rosenfeld D, Panfil SL, Zur Y,. Design of adiabatic pulses for fat-suppression using analytic solutions of the Bloch equation. Magn Reson Med 1997; 37: 793-801. (Pubitemid 27187821)
-
(1997)
Magnetic Resonance in Medicine
, vol.37
, Issue.5
, pp. 793-801
-
-
Rosenfeld, D.1
Panfil, S.L.2
Zur, Y.3
-
16
-
-
84869462402
-
Rapid gradient-echo imaging
-
Hargreaves BA,. Rapid gradient-echo imaging. J Magn Reson Imaging 2012; 36: 1300-1313.
-
(2012)
J Magn Reson Imaging
, vol.36
, pp. 1300-1313
-
-
Hargreaves, B.A.1
-
17
-
-
0023872880
-
An analysis of fast imaging sequences with steady-state transverse magnetization refocusing
-
Zur Y, Stokar S, Bendel P,. An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 1988; 6: 175-193. (Pubitemid 18066057)
-
(1988)
Magnetic Resonance in Medicine
, vol.6
, Issue.2
, pp. 175-193
-
-
Zur, Y.1
Stokar, S.2
Bendel, P.3
-
18
-
-
4344614596
-
Quantitative evaluation of metal artifact reduction techniques
-
DOI 10.1002/jmri.20144
-
Kolind SH, MacKay AL, Munk PL, Xiang QS,. Quantitative evaluation of metal artifact reduction techniques. J Magn Reson Imaging 2004; 20: 487-495. (Pubitemid 39121948)
-
(2004)
Journal of Magnetic Resonance Imaging
, vol.20
, Issue.3
, pp. 487-495
-
-
Kolind, S.H.1
MacKay, A.L.2
Munk, P.L.3
Xiang, Q.-S.4
-
19
-
-
0000389382
-
Active magnetic screening of gradient coils in NMR imaging
-
Mansfield P, Chapman BLW,. Active magnetic screening of gradient coils in NMR imaging. J Magn Reson 1986; 66: 573-576.
-
(1986)
J Magn Reson
, vol.66
, pp. 573-576
-
-
Mansfield, P.1
Chapman, B.L.W.2
-
20
-
-
0002982248
-
Self-shielded gradient coils for nuclear magnetic resonance imaging
-
Roemer PB, Hickey JS,. Self-shielded gradient coils for nuclear magnetic resonance imaging. US Patent 1988; 4, 737, 716.
-
(1988)
US Patent
, vol.4
, Issue.737
, pp. 716
-
-
Roemer, P.B.1
Hickey, J.S.2
-
22
-
-
44949288378
-
Optimization of eddy current compensation
-
Van Vaals JJ, Bergman AH,. Optimization of eddy current compensation. J Magn Reson 1990; 90: 52-70.
-
(1990)
J Magn Reson
, vol.90
, pp. 52-70
-
-
Van Vaals, J.J.1
Bergman, A.H.2
-
23
-
-
0027602212
-
Semiautomated method for noise reduction and background phase error correction in MR phase velocity data
-
Walker PG, Cranney GB, Scheidegger MB, Waseleski G, Pohost GM, Yoganathan AP,. Semiautomated method for noise reduction and background phase error correction in MR phase velocity data. J Magn Reson Imaging 1993; 3: 521-530.
-
(1993)
J Magn Reson Imaging
, vol.3
, pp. 521-530
-
-
Walker, P.G.1
Cranney, G.B.2
Scheidegger, M.B.3
Waseleski, G.4
Pohost, G.M.5
Yoganathan, A.P.6
-
24
-
-
0029303811
-
Validation of cine phase-contrast MR imaging for motion analysis
-
Lingamneni A, Hardy PA, Powell KA, Pelc NJ, White RD,. Validation of cine phase-contrast MR imaging for motion analysis. J Magn Reson Imaging 1995; 5: 331-338.
-
(1995)
J Magn Reson Imaging
, vol.5
, pp. 331-338
-
-
Lingamneni, A.1
Hardy, P.A.2
Powell, K.A.3
Pelc, N.J.4
White, R.D.5
-
25
-
-
84882673293
-
Fast spin echo prescan for MRI system
-
Hinks RS,. Fast spin echo prescan for MRI system. U.S. Patent 1995; 5, 378, 985.
-
(1995)
U.S. Patent
, vol.5
, Issue.378
, pp. 985
-
-
Hinks, R.S.1
-
26
-
-
84882615086
-
Fast spin echo phase correction for MRI system
-
Ma J, Zhou X,. Fast spin echo phase correction for MRI system. U.S. Patent 2002; 6, 369, 568.
-
(2002)
U.S. Patent
, vol.6
, Issue.369
, pp. 568
-
-
Ma, J.1
Zhou, X.2
-
27
-
-
6844246168
-
Method for correcting image distortion due to gradient nonuniformity
-
Glover GH, Pelc NJ,. Method for correcting image distortion due to gradient nonuniformity. U.S. Patent 1986; 4, 591, 789.
-
(1986)
U.S. Patent
, vol.4
, Issue.591
, pp. 789
-
-
Glover, G.H.1
Pelc, N.J.2
-
28
-
-
17144430524
-
A complete distortion correction for MR images: I. Gradient warp correction
-
DOI 10.1088/0031-9155/50/7/001
-
Doran SJ, Charles-Edwards L, Reinsberg SA, Leach MO,. A complete distortion correction for MR images: I. Gradient warp correction. Phys Med Biol 2005; 50: 1343-1361. (Pubitemid 40524529)
-
(2005)
Physics in Medicine and Biology
, vol.50
, Issue.7
, pp. 1343-1361
-
-
Doran, S.J.1
Charles-Edwards, L.2
Reinsberg, S.A.3
Leach, M.O.4
-
29
-
-
12744262814
-
Central brightening due to constructive interference with, without, and despite dielectric resonance
-
Collins CM, Liu W, Schreiber W, Yang QX, Smith MB,. Central brightening due to constructive interference with, without, and despite dielectric resonance. J Magn Reson Imaging 2005; 21: 192-196.
-
(2005)
J Magn Reson Imaging
, vol.21
, pp. 192-196
-
-
Collins, C.M.1
Liu, W.2
Schreiber, W.3
Yang, Q.X.4
Smith, M.B.5
-
30
-
-
33947162337
-
A simple solution for reducing artefacts due to conductive and dielectric effects in clinical magnetic resonance imaging at 3 T
-
DOI 10.1016/j.ejrad.2006.11.014, PII S0720048X06004827
-
Sreenivas M, Lowry M, Gibbs P, Pickles M, Turnbull LW,. A simple solution for reducing artefacts due to conductive and dielectric effects in clinical magnetic resonance imaging at 3T. Eur J Radiol 2007; 62: 143-146. (Pubitemid 46413622)
-
(2007)
European Journal of Radiology
, vol.62
, Issue.1
, pp. 143-146
-
-
Sreenivas, M.1
Lowry, M.2
Gibbs, P.3
Pickles, M.4
Turnbull, L.W.5
-
31
-
-
44449139521
-
Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion
-
DOI 10.1002/jmri.21164
-
Franklin KM, Dale BM, Merkle EM,. Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion. J Magn Reson Imaging 2008; 27: 1443-1447. (Pubitemid 351770701)
-
(2008)
Journal of Magnetic Resonance Imaging
, vol.27
, Issue.6
, pp. 1443-1447
-
-
Franklin, K.M.1
Dale, B.M.2
Merkle, E.M.3
-
32
-
-
34948897576
-
Body MR imaging at 3.0 T: Understanding the opportunities and challenges
-
discussion 1462-1444
-
Barth MM, Smith MP, Pedrosa I, Lenkinski RE, Rofsky NM,. Body MR imaging at 3.0 T: understanding the opportunities and challenges. Radiographics 2007; 27: 1445-1462; discussion 1462-1444.
-
(2007)
Radiographics
, vol.27
, pp. 1445-1462
-
-
Barth, M.M.1
Smith, M.P.2
Pedrosa, I.3
Lenkinski, R.E.4
Rofsky, N.M.5
-
33
-
-
33744534543
-
Parallel RF transmission in MRI
-
DOI 10.1002/nbm.1049
-
Katscher U, Bornert P,. Parallel RF transmission in MRI. NMR Biomed 2006; 19: 393-400. (Pubitemid 43811112)
-
(2006)
NMR in Biomedicine
, vol.19
, Issue.3
, pp. 393-400
-
-
Katscher, U.1
Bornert, P.2
-
34
-
-
33846078031
-
Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
-
DOI 10.1002/mrm.21120
-
Yarnykh VL,. Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med 2007; 57: 192-200. (Pubitemid 46067949)
-
(2007)
Magnetic Resonance in Medicine
, vol.57
, Issue.1
, pp. 192-200
-
-
Yarnykh, V.L.1
-
35
-
-
77955289545
-
B1 mapping by Bloch-Siegert shift
-
Sacolick LI, Wiesinger F, Hancu I, Vogel MW,. B1 mapping by Bloch-Siegert shift. Magn Reson Med 2010; 63: 1315-1322.
-
(2010)
Magn Reson Med
, vol.63
, pp. 1315-1322
-
-
Sacolick, L.I.1
Wiesinger, F.2
Hancu, I.3
Vogel, M.W.4
-
36
-
-
0025226022
-
Mueller OM. The NMR phased array
-
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM. The NMR phased array. Magn Reson Med 1990; 16: 192-225.
-
(1990)
Magn Reson Med
, vol.16
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
-
37
-
-
33847774807
-
A review of methods for correction of intensity inhomogeneity in MRI
-
DOI 10.1109/TMI.2006.891486
-
Vovk U, Pernus F, Likar B,. A review of methods for correction of intensity inhomogeneity in MRI. IEEE Trans Med Imaging 2007; 26: 405-421. (Pubitemid 46392348)
-
(2007)
IEEE Transactions on Medical Imaging
, vol.26
, Issue.3
, pp. 405-421
-
-
Vovk, U.1
Pernus, F.2
Likar, B.3
-
38
-
-
84925562974
-
The FSE "cusp" artifact: Interactions between rf rolloff, gradient rollover, and B0 homogeneity
-
Nice, France, (abstract 756)
-
Steckner MC, Dannels WR,. The FSE "cusp" artifact: interactions between rf rolloff, gradient rollover, and B0 homogeneity. In: Proceedings of the 3rd Annual Meeting of ISMRM, Nice, France, 1995. (abstract 756).
-
(1995)
Proceedings of the 3rd Annual Meeting of ISMRM
-
-
Steckner, M.C.1
Dannels, W.R.2
-
39
-
-
84882624531
-
The FSE cusp artifact: A phase wrap-in artifact seen on routine clinical MR images of the knee
-
Philadelphia, Pennsylvania, (abstract 1033)
-
Kim JK, White LM, Hinks RS, King KF,. The FSE cusp artifact: a phase wrap-in artifact seen on routine clinical MR images of the knee. In: Proceedings of the 7th Annual Meeting of ISMRM, Philadelphia, Pennsylvania, 1999. (abstract 1033).
-
(1999)
Proceedings of the 7th Annual Meeting of ISMRM
-
-
Kim, J.K.1
White, L.M.2
Hinks, R.S.3
King, K.F.4
-
40
-
-
84882633864
-
Method and system of MR imaging with reduced FSE cusp artifacts
-
King KF, Hinks RS,. Method and system of MR imaging with reduced FSE cusp artifacts. U.S. Patent 2007; 7, 250, 762.
-
(2007)
U.S. Patent
, vol.7
, Issue.250
, pp. 762
-
-
King, K.F.1
Hinks, R.S.2
-
41
-
-
84882678146
-
Method for reducing artifacts in MR images acquired with phased array surface coil
-
Frederick PS, Johnson JA,. Method for reducing artifacts in MR images acquired with phased array surface coil. U.S. Patent 2000; 6, 134, 465.
-
(2000)
U.S. Patent
, vol.6
, Issue.134
, pp. 465
-
-
Frederick, P.S.1
Johnson, J.A.2
-
42
-
-
0028397143
-
SNORE: Spike noise removal and detection
-
Foo TF, Grigsby NS, Mitchell JD, Slayman BE,. SNORE: spike noise removal and detection. IEEE Trans Med Imaging 1994; 13: 133-136.
-
(1994)
IEEE Trans Med Imaging
, vol.13
, pp. 133-136
-
-
Foo, T.F.1
Grigsby, N.S.2
Mitchell, J.D.3
Slayman, B.E.4
-
43
-
-
0019043355
-
Spin warp NMR imaging and applications to human whole-body imaging
-
Edelstein WA, Hutchison JM, Johnson G, Redpath T,. Spin warp NMR imaging and applications to human whole-body imaging. Phys Med Biol 1980; 25: 751-756.
-
(1980)
Phys Med Biol
, vol.25
, pp. 751-756
-
-
Edelstein, W.A.1
Hutchison, J.M.2
Johnson, G.3
Redpath, T.4
-
44
-
-
0036263907
-
Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
-
DOI 10.1002/mrm.10171
-
Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002; 47: 1202-1210. (Pubitemid 34587412)
-
(2002)
Magnetic Resonance in Medicine
, vol.47
, Issue.6
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
45
-
-
38949120094
-
Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods
-
DOI 10.1002/mrm.21481
-
Brau AC, Beatty PJ, Skare S, Bammer R,. Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods. Magn Reson Med 2008; 59: 382-395. (Pubitemid 351220102)
-
(2008)
Magnetic Resonance in Medicine
, vol.59
, Issue.2
, pp. 382-395
-
-
Brau, A.C.S.1
Beatty, P.J.2
Skare, S.3
Bammer, R.4
-
46
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
-
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P,. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42: 952-962. (Pubitemid 29521486)
-
(1999)
Magnetic Resonance in Medicine
, vol.42
, Issue.5
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
47
-
-
9644252786
-
The SENSE ghost: Field-of-view restrictions for SENSE imaging
-
DOI 10.1002/jmri.20204
-
Goldfarb JW,. The SENSE ghost: field-of-view restrictions for SENSE imaging. J Magn Reson Imaging 2004; 20: 1046-1051. (Pubitemid 39577908)
-
(2004)
Journal of Magnetic Resonance Imaging
, vol.20
, Issue.6
, pp. 1046-1051
-
-
Goldfarb, J.W.1
-
48
-
-
0022001804
-
Edge artifacts in MR images: Chemical shift effect
-
Babcock EE, Brateman L, Weinreb JC, Horner SD, Nunnally RL,. Edge artifacts in MR images: chemical shift effect. J Comput Assist Tomogr 1985; 9: 252-257. (Pubitemid 15115312)
-
(1985)
Journal of Computer Assisted Tomography
, vol.9
, Issue.2
, pp. 252-257
-
-
Babcock, E.E.1
Brateman, L.2
Weinreb, J.C.3
-
50
-
-
0023277320
-
Chemical shift-induced amplitude modulations in images obtained with gradient refocusing
-
DOI 10.1016/0730-725X(87)90045-2
-
Wehrli FW, Perkins TG, Shimakawa A, Roberts F,. Chemical shift-induced amplitude modulations in images obtained with gradient refocusing. Magn Reson Imaging 1987; 5: 157-158. (Pubitemid 17082839)
-
(1987)
Magnetic Resonance Imaging
, vol.5
, Issue.2
, pp. 157-158
-
-
Wehrli, F.W.1
Perkins, T.G.2
Shimakawa, A.3
Roberts, F.4
-
51
-
-
0026788427
-
Chemical shift magnetic resonance imaging: Applications in the abdomen and pelvis
-
Mitchell DG,. Chemical shift magnetic resonance imaging: applications in the abdomen and pelvis. Top Magn Reson Imaging 1992; 4: 46-63.
-
(1992)
Top Magn Reson Imaging
, vol.4
, pp. 46-63
-
-
Mitchell, D.G.1
-
52
-
-
0026770295
-
Factors influencing contrast in fast spin-echo MR imaging
-
Constable RT, Anderson AW, Zhong J, Gore JC,. Factors influencing contrast in fast spin-echo MR imaging. Magn Reson Imaging 1992; 10: 497-511.
-
(1992)
Magn Reson Imaging
, vol.10
, pp. 497-511
-
-
Constable, R.T.1
Anderson, A.W.2
Zhong, J.3
Gore, J.C.4
-
53
-
-
0021958023
-
MR image artifacts from periodic motion
-
DOI 10.1118/1.595782
-
Wood ML, Henkelman RM,. MR image artifacts from periodic motion. Med Phys 1985; 12: 143-151. (Pubitemid 15088996)
-
(1985)
Medical Physics
, vol.12
, Issue.2
, pp. 143-151
-
-
Wood, M.L.1
Henkelman, R.M.2
-
55
-
-
0023197057
-
Spatial presaturation: A method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging
-
Felmlee JP, Ehman RL,. Spatial presaturation: a method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging. Radiology 1987; 164: 559-564. (Pubitemid 17097985)
-
(1987)
Radiology
, vol.164
, Issue.2
, pp. 559-564
-
-
Felmlee, J.P.1
Ehman, R.L.2
-
56
-
-
0027931324
-
MR imaging of the liver at 1.5 T: Value of signal averaging in suppressing motion artifacts
-
Gazelle GS, Saini S, Hahn PF, Goldberg MA, Halpern EF,. MR imaging of the liver at 1.5 T: value of signal averaging in suppressing motion artifacts. AJR Am J Roentgenol 1994; 163: 335-337. (Pubitemid 24242514)
-
(1994)
American Journal of Roentgenology
, vol.163
, Issue.2
, pp. 335-337
-
-
Gazelle, G.S.1
Saini, S.2
Hahn, P.F.3
Goldberg, M.A.4
Halpern, E.F.5
-
57
-
-
0022474288
-
Artifacts from pulsatile flow in MR imaging
-
Perman WH, Moran PR, Moran RA, Bernstein MA,. Artifacts from pulsatile flow in MR imaging. J Comput Assist Tomogr 1986; 10: 473-483. (Pubitemid 16066482)
-
(1986)
Journal of Computer Assisted Tomography
, vol.10
, Issue.3
, pp. 473-483
-
-
Perman, W.H.1
Moran, P.R.2
Moran, R.A.3
Bernstein, M.A.4
-
58
-
-
0021235637
-
Direct cardiac NMR imaging of heart wall and blood flow velocity
-
van Dijk P,. Direct cardiac NMR imaging of heart wall and blood flow velocity. J Comput Assist Tomogr 1984; 8: 429-436. (Pubitemid 14112512)
-
(1984)
Journal of Computer Assisted Tomography
, vol.8
, Issue.3
, pp. 429-436
-
-
Van Dijk, P.1
-
59
-
-
0023217321
-
Improving MR image quality in the presence of motion by using rephasing gradients
-
Haacke EM, Lenz GW,. Improving MR image quality in the presence of motion by using rephasing gradients. AJR Am J Roentgenol 1987; 148: 1251-1258. (Pubitemid 17083103)
-
(1987)
American Journal of Roentgenology
, vol.148
, Issue.6
, pp. 1251-1258
-
-
Haacke, E.M.1
Lenz, G.W.2
-
60
-
-
0025182426
-
Flow artifact reduction in MRI: A review of the roles of gradient moment nulling and spatial presaturation
-
DOI 10.1002/mrm.1910140214
-
Ehman RL, Felmlee JP,. Flow artifact reduction in MRI: a review of the roles of gradient moment nulling and spatial presaturation. Magn Reson Med 1990; 14: 293-307. (Pubitemid 20248613)
-
(1990)
Magnetic Resonance in Medicine
, vol.14
, Issue.2
, pp. 293-307
-
-
Ehman, R.L.1
Felmlee, J.P.2
|