-
1
-
-
0033870513
-
A combined PET/CT scanner for clinical oncology
-
Beyer T. A combined PET/CT scanner for clinical oncology. J. Nucl. Med. 2000, 41:1369-1379.
-
(2000)
J. Nucl. Med.
, vol.41
, pp. 1369-1379
-
-
Beyer, T.1
-
2
-
-
84882557046
-
BeneWt of time-of-Xight information for whole-body FDG PET
-
Karp J.S. BeneWt of time-of-Xight information for whole-body FDG PET. J. Nucl. Med. 2006, 47(suppl):529.
-
(2006)
J. Nucl. Med.
, vol.47
, Issue.SUPPL.
, pp. 529
-
-
Karp, J.S.1
-
3
-
-
0033429622
-
Absolute quantitation of iodine-123 epidepride kinetics using single-photon emission tomography: Comparison with carbon-11 epidepride and positron emission to
-
Almeida P. Absolute quantitation of iodine-123 epidepride kinetics using single-photon emission tomography: Comparison with carbon-11 epidepride and positron emission to. Eur. J. Nucl. Med. 1999, 26:1580-1588.
-
(1999)
Eur. J. Nucl. Med.
, vol.26
, pp. 1580-1588
-
-
Almeida, P.1
-
4
-
-
2542423938
-
Brain 18F-FDG PET in the diagnosis of neurodegenerative dementias: Comparison with perfusion SPECT and with clinical evaluations lacking nuclear imaging
-
Silverman D.H.S. Brain 18F-FDG PET in the diagnosis of neurodegenerative dementias: Comparison with perfusion SPECT and with clinical evaluations lacking nuclear imaging. J. Nucl. Med. 2004, 45:597-607.
-
(2004)
J. Nucl. Med.
, vol.45
, pp. 597-607
-
-
Silverman, D.H.S.1
-
5
-
-
33645225125
-
A brief introduction to functional MRI
-
Pekar J.J. A brief introduction to functional MRI. IEEE Eng. Med. Biol. Mag. 2006, 35:24-26.
-
(2006)
IEEE Eng. Med. Biol. Mag.
, vol.35
, pp. 24-26
-
-
Pekar, J.J.1
-
6
-
-
0030679603
-
Requirements and implementation of a Xexible kinetic modeling tool
-
Burger C., Buck A. Requirements and implementation of a Xexible kinetic modeling tool. J. Nucl. Med. 1997, 138:1818-1823.
-
(1997)
J. Nucl. Med.
, vol.138
, pp. 1818-1823
-
-
Burger, C.1
Buck, A.2
-
8
-
-
0018845316
-
Noninvasive determination of local cerebral metabolic rate of glucose in man
-
Huang S.-C. Noninvasive determination of local cerebral metabolic rate of glucose in man. Am. J. Physiol. 1980, 238:E69-E82.
-
(1980)
Am. J. Physiol.
, vol.238
-
-
Huang, S.-C.1
-
10
-
-
0030815476
-
Parameter estimation techniques: A tutorial with application to conic Wtting
-
Zhang Z. Parameter estimation techniques: A tutorial with application to conic Wtting. Image and Vision Computing Journal 1997, 15:59-76.
-
(1997)
Image and Vision Computing Journal
, vol.15
, pp. 59-76
-
-
Zhang, Z.1
-
11
-
-
44349129408
-
The theory and applications of the exchange of inert gas at the lungs and tissues
-
Kety S.S. The theory and applications of the exchange of inert gas at the lungs and tissues. Pharmacol. Rev. 1951, 3:1-41.
-
(1951)
Pharmacol. Rev.
, vol.3
, pp. 1-41
-
-
Kety, S.S.1
-
12
-
-
0001609545
-
Measurement of local blood Xow by the exchange of an inert, diVusible substance
-
Kety S.S. Measurement of local blood Xow by the exchange of an inert, diVusible substance. Methods Med. Res. 1960, 8:228-236.
-
(1960)
Methods Med. Res.
, vol.8
, pp. 228-236
-
-
Kety, S.S.1
-
13
-
-
0026718393
-
Parameter-estimation by least-squares methods
-
Johnson M.L., Faunt L.M. Parameter-estimation by least-squares methods. Methods Enzymol. 1992, 210:1-37.
-
(1992)
Methods Enzymol.
, vol.210
, pp. 1-37
-
-
Johnson, M.L.1
Faunt, L.M.2
-
17
-
-
0035001109
-
An introduction to PET and SPECT neuroreceptor quantiWcation models
-
Ichise M., Meyer J.H., Yonekura Y. An introduction to PET and SPECT neuroreceptor quantiWcation models. J. Nucl. Med. 2001, 42:755-763.
-
(2001)
J. Nucl. Med.
, vol.42
, pp. 755-763
-
-
Ichise, M.1
Meyer, J.H.2
Yonekura, Y.3
-
18
-
-
0002171921
-
Accuracy of the oxygen-15 steady state technique for measuring rCBF and rCMRO2
-
Lammertsma A.A. Accuracy of the oxygen-15 steady state technique for measuring rCBF and rCMRO2. J. Cereb. Blood Flow Metab. 1981, 1(suppl):S3-S4.
-
(1981)
J. Cereb. Blood Flow Metab.
, vol.1
, Issue.SUPPL.
-
-
Lammertsma, A.A.1
-
19
-
-
0021255070
-
The requirement for constant arterial radioactivity in the C15O2 steady-state blood Xow model
-
Meyer E., Yamamoto Y.L. The requirement for constant arterial radioactivity in the C15O2 steady-state blood Xow model. J. Nucl. Med. 1984, 25:455-460.
-
(1984)
J. Nucl. Med.
, vol.25
, pp. 455-460
-
-
Meyer, E.1
Yamamoto, Y.L.2
-
20
-
-
0022353350
-
Analysis of some errors in the measurement of oxygen extraction and oxygen consumption by the equilibrium inhalation method
-
Correia J.A. Analysis of some errors in the measurement of oxygen extraction and oxygen consumption by the equilibrium inhalation method. J. Cereb. Blood Flow Metab. 1985, 5:591-599.
-
(1985)
J. Cereb. Blood Flow Metab.
, vol.5
, pp. 591-599
-
-
Correia, J.A.1
-
21
-
-
0036392071
-
Measurement of glucose consumption using [18F]Xuorodeoxyglucose
-
Wienhard K. Measurement of glucose consumption using [18F]Xuorodeoxyglucose. Methods 2002, 27:218-225.
-
(2002)
Methods
, vol.27
, pp. 218-225
-
-
Wienhard, K.1
-
22
-
-
0021985843
-
Glucose metabolic rate kinetic model parameter determination in humans: The lumped constants and rate constants for [18F]Xuorodeoxyglucose and [11C]deoxygluco
-
Reivich M. Glucose metabolic rate kinetic model parameter determination in humans: The lumped constants and rate constants for [18F]Xuorodeoxyglucose and [11C]deoxygluco. J. Cereb. Blood Flow Metab. 1985, 5:179-192.
-
(1985)
J. Cereb. Blood Flow Metab.
, vol.5
, pp. 179-192
-
-
Reivich, M.1
-
23
-
-
0021322753
-
Alternative approach to single-scan estimation of cerebral glucose metabolic rate using glucose analogs with particular application to ischemia
-
Hutchins G.D. Alternative approach to single-scan estimation of cerebral glucose metabolic rate using glucose analogs with particular application to ischemia. J. Cereb. Blood Flow Metab. 1984, 4:35-40.
-
(1984)
J. Cereb. Blood Flow Metab.
, vol.4
, pp. 35-40
-
-
Hutchins, G.D.1
-
24
-
-
0019987721
-
Alternative formula for glucose utilization using labeled deoxyglucose
-
Brooks R.A. Alternative formula for glucose utilization using labeled deoxyglucose. J. Nucl. Med. 1982, 23:533-539.
-
(1982)
J. Nucl. Med.
, vol.23
, pp. 533-539
-
-
Brooks, R.A.1
-
25
-
-
0026518393
-
A method for comparing diVerent procedures of estimating regional glucose metabolism using Xuorine-18-Xuorodeoxyglucose
-
Clark C.M., Grochowski E.W., Ammann W. A method for comparing diVerent procedures of estimating regional glucose metabolism using Xuorine-18-Xuorodeoxyglucose. J. Nucl. Med. 1992, 33:157-160.
-
(1992)
J. Nucl. Med.
, vol.33
, pp. 157-160
-
-
Clark, C.M.1
Grochowski, E.W.2
Ammann, W.3
-
26
-
-
0021013306
-
Vivo disturbance of the oxidative metabolism of glucose in human cerebral gliomas
-
Rhodes C.G. vivo disturbance of the oxidative metabolism of glucose in human cerebral gliomas. Ann. Neurol. 1983, 14:614-626.
-
(1983)
Ann. Neurol.
, vol.14
, pp. 614-626
-
-
Rhodes, C.G.1
-
27
-
-
0033737712
-
Anatomy of SUV
-
Huang S.-C. Anatomy of SUV. Nucl. Med. Biol. 2000, 27:643-646.
-
(2000)
Nucl. Med. Biol.
, vol.27
, pp. 643-646
-
-
Huang, S.-C.1
-
28
-
-
0027505656
-
InXuence of the blood glucose concentration on FDG uptake in cancer-A PET study
-
Lindholm P. InXuence of the blood glucose concentration on FDG uptake in cancer-A PET study. J. Nucl. Med. 1993, 34:1-6.
-
(1993)
J. Nucl. Med.
, vol.34
, pp. 1-6
-
-
Lindholm, P.1
-
29
-
-
0028784446
-
SUV: Standard uptake or silly useless value
-
Keyes J.W. SUV: Standard uptake or silly useless value. J. Nucl. Med. 1995, 36:1836-1839.
-
(1995)
J. Nucl. Med.
, vol.36
, pp. 1836-1839
-
-
Keyes, J.W.1
-
30
-
-
0027367203
-
Standardized uptake values of normal tissues at PET with 2-[Xuorine-18]-Xuoro-2-deoxy-D-glucose: Variations with body weight and a method for correction
-
Zasadny K.R., Wahl R.L. Standardized uptake values of normal tissues at PET with 2-[Xuorine-18]-Xuoro-2-deoxy-D-glucose: Variations with body weight and a method for correction. Radiology 1993, 189:847-850.
-
(1993)
Radiology
, vol.189
, pp. 847-850
-
-
Zasadny, K.R.1
Wahl, R.L.2
-
31
-
-
0027982920
-
Standardized uptake values of FDG: Body surface area correction is preferable to body weight correction
-
Kim C.K. Standardized uptake values of FDG: Body surface area correction is preferable to body weight correction. J. Nucl. Med. 1994, 35:164-167.
-
(1994)
J. Nucl. Med.
, vol.35
, pp. 164-167
-
-
Kim, C.K.1
-
32
-
-
0020063566
-
Measurement of local blood Xow and distribution volume with short-lived isotopes: a general input technique
-
Huang S.-C., Carson R.E., Phelps M.E. Measurement of local blood Xow and distribution volume with short-lived isotopes: a general input technique. J. Cereb. Blood Flow Metab. 1982, 2:99-108.
-
(1982)
J. Cereb. Blood Flow Metab.
, vol.2
, pp. 99-108
-
-
Huang, S.-C.1
Carson, R.E.2
Phelps, M.E.3
-
33
-
-
0020954789
-
Quantitative measurement of local cerebral blood Xow in humans by positron computed tomography and 15O-water
-
Huang S.-C. Quantitative measurement of local cerebral blood Xow in humans by positron computed tomography and 15O-water. J. Cereb. Blood Flow Metab. 1983, 3:141-153.
-
(1983)
J. Cereb. Blood Flow Metab.
, vol.3
, pp. 141-153
-
-
Huang, S.-C.1
-
34
-
-
0003164507
-
Techniques for functional imaging
-
Gordon and Breach Science Publishers, C.T. Leondes, D. Feng (Eds.)
-
Feng D. Techniques for functional imaging. Medical Imaging Systems Techniques and Applications 1997, 85-145. Gordon and Breach Science Publishers. C.T. Leondes, D. Feng (Eds.).
-
(1997)
Medical Imaging Systems Techniques and Applications
, pp. 85-145
-
-
Feng, D.1
-
35
-
-
0021319792
-
Strategy for the measurement of regional cerebral blood Xow using short-lived tracers and emission tomography
-
Alpert N.M. Strategy for the measurement of regional cerebral blood Xow using short-lived tracers and emission tomography. J. Nucl. Med. 1984, 4:28-34.
-
(1984)
J. Nucl. Med.
, vol.4
, pp. 28-34
-
-
Alpert, N.M.1
-
36
-
-
0022601993
-
Weighted integration method for local cerebral blood Xow measurements with positron emission tomography
-
Carson R.E., Huang S.-C., Green M.V. Weighted integration method for local cerebral blood Xow measurements with positron emission tomography. J. Cereb. Blood Flow Metab. 1986, 6:245-258.
-
(1986)
J. Cereb. Blood Flow Metab.
, vol.6
, pp. 245-258
-
-
Carson, R.E.1
Huang, S.-C.2
Green, M.V.3
-
37
-
-
0025756867
-
A new approach of weighted integration technique based on accumulated image using dynamic PET and H2 15O
-
Yokoi T. A new approach of weighted integration technique based on accumulated image using dynamic PET and H2 15O. J. Cereb. Blood Flow Metab. 1991, 11:492-501.
-
(1991)
J. Cereb. Blood Flow Metab.
, vol.11
, pp. 492-501
-
-
Yokoi, T.1
-
38
-
-
0029269576
-
Effect of real-time weighted integration system for rapid calculation of functional images in clinical positron emission tomography
-
Iida H. Effect of real-time weighted integration system for rapid calculation of functional images in clinical positron emission tomography. IEEE Trans. Med. Imaging 1995, 14:116-121.
-
(1995)
IEEE Trans. Med. Imaging
, vol.14
, pp. 116-121
-
-
Iida, H.1
-
39
-
-
0029484122
-
An evaluation of the algorithms for determining local cerebral metabolic rates of glucose using positron emission tomography dynamic data
-
Feng D. An evaluation of the algorithms for determining local cerebral metabolic rates of glucose using positron emission tomography dynamic data. IEEE Trans. Med. Imaging 1995, 14:697-710.
-
(1995)
IEEE Trans. Med. Imaging
, vol.14
, pp. 697-710
-
-
Feng, D.1
-
40
-
-
0031847281
-
Pharmacokinetic assessment of novel anti-cancer drugs using spectral analysis and positron emission tomography: a feasibility study, Cancer Chemother
-
Meikle S.R. Pharmacokinetic assessment of novel anti-cancer drugs using spectral analysis and positron emission tomography: a feasibility study, Cancer Chemother. Pharmacol. 1998, 42:183-193.
-
(1998)
Pharmacol.
, vol.42
, pp. 183-193
-
-
Meikle, S.R.1
-
42
-
-
0028179229
-
The use of spectral analysis to determine regional cerebral glucose utilization with positron emission tomography and [18F]Xuorodeoxyglucose: Theory, implemen
-
Turkheimer F. The use of spectral analysis to determine regional cerebral glucose utilization with positron emission tomography and [18F]Xuorodeoxyglucose: Theory, implemen. J. Cereb. Blood Flow Metab. 1994, 14:406-422.
-
(1994)
J. Cereb. Blood Flow Metab.
, vol.14
, pp. 406-422
-
-
Turkheimer, F.1
-
43
-
-
0030956911
-
The direct calculation of parametric images from dynamic PET data using maximumlikelihood iterative reconstruction
-
Matthews J. The direct calculation of parametric images from dynamic PET data using maximumlikelihood iterative reconstruction. Physics Med. Biol. 1997, 42:1155-1173.
-
(1997)
Physics Med. Biol.
, vol.42
, pp. 1155-1173
-
-
Matthews, J.1
-
44
-
-
0020956774
-
Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data
-
Patlak C.S., Blasberg R.G., Fenstermacher J.D. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J. Cereb. Blood Flow Metab. 1983, 3:1-7.
-
(1983)
J. Cereb. Blood Flow Metab.
, vol.3
, pp. 1-7
-
-
Patlak, C.S.1
Blasberg, R.G.2
Fenstermacher, J.D.3
-
45
-
-
0022389649
-
Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data Generalizations
-
Patlak C.S., Blasberg R.G. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data Generalizations. J. Cereb. Blood Flow Metab. 1985, 5:584-590.
-
(1985)
J. Cereb. Blood Flow Metab.
, vol.5
, pp. 584-590
-
-
Patlak, C.S.1
Blasberg, R.G.2
-
46
-
-
0021920844
-
Estimation of local cerebral glucose utilization by positron emission tomography of [18F] 2-Xuoro-2-deoxy-D-glucose: A critical appraisal of optimization proc
-
Wienhard K. Estimation of local cerebral glucose utilization by positron emission tomography of [18F] 2-Xuoro-2-deoxy-D-glucose: A critical appraisal of optimization proc. J. Cereb. Blood Flow Metab. 1985, 5:115-125.
-
(1985)
J. Cereb. Blood Flow Metab.
, vol.5
, pp. 115-125
-
-
Wienhard, K.1
-
47
-
-
0025127930
-
Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects
-
Logan J. Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects. J. Cereb. Blood Flow Metab. 1990, 10:740-747.
-
(1990)
J. Cereb. Blood Flow Metab.
, vol.10
, pp. 740-747
-
-
Logan, J.1
-
48
-
-
0028051572
-
Effects of blood Xow on [11C]raclopride binding in the brain: model simulations and kinetic analysis of PET data
-
Logan J. Effects of blood Xow on [11C]raclopride binding in the brain: model simulations and kinetic analysis of PET data. J. Cereb. Blood Flow Metab. 1994, 14:995-1010.
-
(1994)
J. Cereb. Blood Flow Metab.
, vol.14
, pp. 995-1010
-
-
Logan, J.1
-
49
-
-
0027463831
-
A new graphic plot analysis for cerebral blood Xow and partition coeYcient with iodine-123-iodoamphetamine and dynamic SPECT validation studies using oxygen-1
-
Yokoi T. A new graphic plot analysis for cerebral blood Xow and partition coeYcient with iodine-123-iodoamphetamine and dynamic SPECT validation studies using oxygen-1. J. Nucl. Med. 1993, 34:498-505.
-
(1993)
J. Nucl. Med.
, vol.34
, pp. 498-505
-
-
Yokoi, T.1
-
51
-
-
0030216228
-
An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation
-
Feng D. An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation. IEEE Trans. Med. Imaging 1996, 15:512-518.
-
(1996)
IEEE Trans. Med. Imaging
, vol.15
, pp. 512-518
-
-
Feng, D.1
-
52
-
-
0027609849
-
A study on statistically reliable and computationally eYcient algorithms for generating local cerebral blood Xow parametric image with positron emission tomog
-
Feng D., Wang Z., Huang S.-C. A study on statistically reliable and computationally eYcient algorithms for generating local cerebral blood Xow parametric image with positron emission tomog. IEEE Trans. Med. Imaging. 1993, 12:182-188.
-
(1993)
IEEE Trans. Med. Imaging.
, vol.12
, pp. 182-188
-
-
Feng, D.1
Wang, Z.2
Huang, S.-C.3
-
53
-
-
0032034228
-
Generalized linear least-squares method for fast generation of myocardial blood Xow parametric images with N-13 ammonia PET
-
Chen K. Generalized linear least-squares method for fast generation of myocardial blood Xow parametric images with N-13 ammonia PET. IEEE Trans. Med. Imaging. 1998, 17:236-243.
-
(1998)
IEEE Trans. Med. Imaging.
, vol.17
, pp. 236-243
-
-
Chen, K.1
-
54
-
-
29744441604
-
Fast parametric imaging algorithm for dual-input biomedical system parameter estimation
-
Choi H.-C. Fast parametric imaging algorithm for dual-input biomedical system parameter estimation. Comput. Methods Programs Biomed. 2006, 81:49-55.
-
(2006)
Comput. Methods Programs Biomed.
, vol.81
, pp. 49-55
-
-
Choi, H.-C.1
-
55
-
-
84882501079
-
Improved generalized linear least squares algorithms for generation of parametric images from dynamic SPECT
-
Wen L. Improved generalized linear least squares algorithms for generation of parametric images from dynamic SPECT. J. Nucl. Med. 2006, 47(suppl):61.
-
(2006)
J. Nucl. Med.
, pp. 61
-
-
Wen, L.1
-
57
-
-
17644385851
-
Effect of reconstruction and Wltering on kinetic parameter estimation bias and reliability for dynamic SPECT: A simulation study
-
Wen L. Effect of reconstruction and Wltering on kinetic parameter estimation bias and reliability for dynamic SPECT: A simulation study. IEEE Trans. Nucl. Sci. 2005, 52:69-78.
-
(2005)
IEEE Trans. Nucl. Sci.
, vol.52
, pp. 69-78
-
-
Wen, L.1
-
59
-
-
18844431381
-
Direct reconstruction of kinetic parameters images from dynamic PET data
-
Kamasak M.E. Direct reconstruction of kinetic parameters images from dynamic PET data. IEEE Trans. Med. Imaging 2005, 24:636-650.
-
(2005)
IEEE Trans. Med. Imaging
, vol.24
, pp. 636-650
-
-
Kamasak, M.E.1
-
60
-
-
0031982333
-
Kinetic parameter estimation from SPECT cone-beam projection measurements
-
Huesman R.H. Kinetic parameter estimation from SPECT cone-beam projection measurements. Physics Med. Biol. 1998, 43:973-982.
-
(1998)
Physics Med. Biol.
, vol.43
, pp. 973-982
-
-
Huesman, R.H.1
-
62
-
-
0000376405
-
Dynamic cardiac single-photon emission computed tomography
-
Mosby-Year Book Inc., France
-
Gullberg G.T. Dynamic cardiac single-photon emission computed tomography. Nuclear Cardiology: State of the Art and Future Directions 1998, 137-187. Mosby-Year Book Inc., France.
-
(1998)
Nuclear Cardiology: State of the Art and Future Directions
, pp. 137-187
-
-
Gullberg, G.T.1
-
63
-
-
0018582265
-
Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18)2-Xuoro-2-deoxy-D-glucose: Validation of method
-
Phelps M.E. Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18)2-Xuoro-2-deoxy-D-glucose: Validation of method. Ann. Neurol. 1979, 6:371-388.
-
(1979)
Ann. Neurol.
, vol.6
, pp. 371-388
-
-
Phelps, M.E.1
-
64
-
-
0024592575
-
Simple noninvasive quantiWcation method for measuring myocardial glucose utilization in humans employing positron emission tomography and Xuorine-18 deoxygluc
-
Gambhir S.S. Simple noninvasive quantiWcation method for measuring myocardial glucose utilization in humans employing positron emission tomography and Xuorine-18 deoxygluc. J. Nucl. Med. 1989, 30:359-366.
-
(1989)
J. Nucl. Med.
, vol.30
, pp. 359-366
-
-
Gambhir, S.S.1
-
65
-
-
0026767631
-
Use of the left ventricular time-activity curve as a noninvasive input function in dynamic oxygen-15-water positron emission tomography
-
Iida H. Use of the left ventricular time-activity curve as a noninvasive input function in dynamic oxygen-15-water positron emission tomography. J. Nucl. Med. 1992, 33:1669-1677.
-
(1992)
J. Nucl. Med.
, vol.33
, pp. 1669-1677
-
-
Iida, H.1
-
66
-
-
0028907866
-
Correction of spillover radioactivities for estimation of the blood time-activity curve from the image LV chamber in cardiac dynamic FDG PET studies
-
Lin K.-P. Correction of spillover radioactivities for estimation of the blood time-activity curve from the image LV chamber in cardiac dynamic FDG PET studies. Physics Med. Biol. 1995, 40:629-642.
-
(1995)
Physics Med. Biol.
, vol.40
, pp. 629-642
-
-
Lin, K.-P.1
-
67
-
-
0032886682
-
Regions of interest in the venous sinuses as input functions for quantitative PET
-
Wahl L.D., Asselin M.C., Nahmias C. Regions of interest in the venous sinuses as input functions for quantitative PET. J. Nucl. Med. 1999, 40:1666-1675.
-
(1999)
J. Nucl. Med.
, vol.40
, pp. 1666-1675
-
-
Wahl, L.D.1
Asselin, M.C.2
Nahmias, C.3
-
68
-
-
0025765313
-
Noninvasive method to obtain input function for measuring tissue glucose utilization of thoracic and abdominal organs
-
Ohtake T. Noninvasive method to obtain input function for measuring tissue glucose utilization of thoracic and abdominal organs. J. Nucl. Med. 1991, 32:1432-1438.
-
(1991)
J. Nucl. Med.
, vol.32
, pp. 1432-1438
-
-
Ohtake, T.1
-
69
-
-
0026532491
-
Use of the abdominal aorta for arterial input function determination in hepatic and renal PET studies
-
Germano G. Use of the abdominal aorta for arterial input function determination in hepatic and renal PET studies. J. Nucl. Med. 1992, 33:613-620.
-
(1992)
J. Nucl. Med.
, vol.33
, pp. 613-620
-
-
Germano, G.1
-
70
-
-
0028018347
-
Quantitative brain FDG/PET studies using dynamic aortic imaging
-
Dhawan V. Quantitative brain FDG/PET studies using dynamic aortic imaging. Physics Med. Biol. 1994, 39:1475-1487.
-
(1994)
Physics Med. Biol.
, vol.39
, pp. 1475-1487
-
-
Dhawan, V.1
-
71
-
-
0031782483
-
Noninvasive quantiWcation of the cerebral metabolic rate for glucose using positron emission tomography, 18F-Xuoro-2-deoxyglucose, the Patlak method, and an i
-
Chen K. Noninvasive quantiWcation of the cerebral metabolic rate for glucose using positron emission tomography, 18F-Xuoro-2-deoxyglucose, the Patlak method, and an i. J. Cereb. Blood Flow Metab. 1998, 18:716-723.
-
(1998)
J. Cereb. Blood Flow Metab.
, vol.18
, pp. 716-723
-
-
Chen, K.1
-
72
-
-
1242293832
-
Cluster analysis in kinetic modelling of the brain: a noninvasive alternative to arterial sampling
-
Liptrot M. Cluster analysis in kinetic modelling of the brain: a noninvasive alternative to arterial sampling. Neuroimage 2004, 21:483-493.
-
(2004)
Neuroimage
, vol.21
, pp. 483-493
-
-
Liptrot, M.1
-
73
-
-
0031282828
-
A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: Theory and simulation study
-
Feng D. A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: Theory and simulation study. IEEE Trans. Inf. Technol. Biomed. 1997, 1:243-254.
-
(1997)
IEEE Trans. Inf. Technol. Biomed.
, vol.1
, pp. 243-254
-
-
Feng, D.1
-
74
-
-
0035263431
-
Simultaneous estimation of physiological parameters and the input function-In vivo PET data
-
Wong K.P. Simultaneous estimation of physiological parameters and the input function-In vivo PET data. IEEE Trans. Inf. Technol. Biomed. 2001, 5:67-76.
-
(2001)
IEEE Trans. Inf. Technol. Biomed.
, vol.5
, pp. 67-76
-
-
Wong, K.P.1
-
75
-
-
0029743481
-
Distribution volume ratios without blood sampling from graphical analysis of PET data
-
Logan J. Distribution volume ratios without blood sampling from graphical analysis of PET data. J. Cereb. Blood Flow Metab. 1996, 16:834-840.
-
(1996)
J. Cereb. Blood Flow Metab.
, vol.16
, pp. 834-840
-
-
Logan, J.1
-
76
-
-
0031279782
-
Parametric imaging of ligand-receptor binding in PET using a simpliWed reference region model
-
Gunn R.N. Parametric imaging of ligand-receptor binding in PET using a simpliWed reference region model. Neuroimage 1997, 6:279-287.
-
(1997)
Neuroimage
, vol.6
, pp. 279-287
-
-
Gunn, R.N.1
-
77
-
-
0030468875
-
SimpliWed reference tissue model for PET receptor studies
-
Lammertsma A.A., Hume S.P. SimpliWed reference tissue model for PET receptor studies. Neuroimage 1996, 4:153-158.
-
(1996)
Neuroimage
, vol.4
, pp. 153-158
-
-
Lammertsma, A.A.1
Hume, S.P.2
-
78
-
-
0036898647
-
Noise reduction in the simpliWed reference tissue model for neuroreceptor functional imaging
-
Wu Y., Carson R.E. Noise reduction in the simpliWed reference tissue model for neuroreceptor functional imaging. J. Cereb. Blood Flow Metab. 2002, 22:1440-1452.
-
(2002)
J. Cereb. Blood Flow Metab.
, vol.22
, pp. 1440-1452
-
-
Wu, Y.1
Carson, R.E.2
-
79
-
-
0033729522
-
Graphical analysis of PET data applied to reversible and irreversible tracers
-
Logan J. Graphical analysis of PET data applied to reversible and irreversible tracers. Nucl. Med. Biol. 2000, 27:661-670.
-
(2000)
Nucl. Med. Biol.
, vol.27
, pp. 661-670
-
-
Logan, J.1
-
80
-
-
0029864267
-
Noninvasive quantiWcation of dopamine D2 receptors with iodine-123-IBF SPECT
-
Ichise M. Noninvasive quantiWcation of dopamine D2 receptors with iodine-123-IBF SPECT. J. Nucl. Med. 1996, 37:513-520.
-
(1996)
J. Nucl. Med.
, vol.37
, pp. 513-520
-
-
Ichise, M.1
-
81
-
-
0041335224
-
Linearized reference tissue parametric imaging methods: Application to [11C]DASB positron emission tomography studies of the serotonin transporter in human br
-
Ichise M. Linearized reference tissue parametric imaging methods: Application to [11C]DASB positron emission tomography studies of the serotonin transporter in human br. J. Cereb. Blood Flow Metab. 2003, 23:1096-1112.
-
(2003)
J. Cereb. Blood Flow Metab.
, vol.23
, pp. 1096-1112
-
-
Ichise, M.1
-
82
-
-
0027161814
-
Noninvasive quantitative Xuorodeoxyglucose PET studies with an estimated input function derived from a population-based arterial blood curve
-
Takikawa S. Noninvasive quantitative Xuorodeoxyglucose PET studies with an estimated input function derived from a population-based arterial blood curve. Radiology 1993, 188:131-136.
-
(1993)
Radiology
, vol.188
, pp. 131-136
-
-
Takikawa, S.1
-
83
-
-
0030895329
-
Evaluation of two population-based input functions for quantitative neurological FDG PET studies
-
Eberl S. Evaluation of two population-based input functions for quantitative neurological FDG PET studies. Eur. J. Nucl. Med. 1997, 24:299-304.
-
(1997)
Eur. J. Nucl. Med.
, vol.24
, pp. 299-304
-
-
Eberl, S.1
-
84
-
-
0033805895
-
SimpliWcation for measuring input function of FDG PET: investigation of 1-point blood sampling method
-
Wakita K. SimpliWcation for measuring input function of FDG PET: investigation of 1-point blood sampling method. J. Nucl. Med. 2000, 41:1484-1490.
-
(2000)
J. Nucl. Med.
, vol.41
, pp. 1484-1490
-
-
Wakita, K.1
-
85
-
-
0032845963
-
Noninvasive measurement of cerebral metabolic rate of glucose using standardized input function
-
Tsuchida T. Noninvasive measurement of cerebral metabolic rate of glucose using standardized input function. J. Nucl. Med. 1999, 40:1441-1445.
-
(1999)
J. Nucl. Med.
, vol.40
, pp. 1441-1445
-
-
Tsuchida, T.1
-
86
-
-
0033770345
-
Noninvasive estimation of FDG input function for quantiWcation of cerebral metabolic rate of glucose: optimization and multicenter evaluation
-
Shiozaki T. Noninvasive estimation of FDG input function for quantiWcation of cerebral metabolic rate of glucose: optimization and multicenter evaluation. J. Nucl. Med. 2000, 41:1612-1618.
-
(2000)
J. Nucl. Med.
, vol.41
, pp. 1612-1618
-
-
Shiozaki, T.1
-
87
-
-
0027572378
-
Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography
-
Feng D., Huang S.-C., Wang X. Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography. Int. J. Biomed. Comput. 1993, 32:95-110.
-
(1993)
Int. J. Biomed. Comput.
, vol.32
, pp. 95-110
-
-
Feng, D.1
Huang, S.-C.2
Wang, X.3
-
88
-
-
0033233328
-
Information technology applications in biomedical functional imaging
-
Feng D. Information technology applications in biomedical functional imaging. IEEE Trans. Inf. Technol. Biomed. 1999, 3:221-230.
-
(1999)
IEEE Trans. Inf. Technol. Biomed.
, vol.3
, pp. 221-230
-
-
Feng, D.1
-
89
-
-
0028533976
-
A computer simulation study on the input function sampling schedules in tracer kinetic modeling with positron emission tomography (PET)
-
Feng D., Wang X., Yan H. A computer simulation study on the input function sampling schedules in tracer kinetic modeling with positron emission tomography (PET). Comput. Methods Programs Biomed. 1994, 45:175-186.
-
(1994)
Comput. Methods Programs Biomed.
, vol.45
, pp. 175-186
-
-
Feng, D.1
Wang, X.2
Yan, H.3
-
90
-
-
28244439860
-
The prediction of rapid conversion to Alzheimer's disease in mild cognitive impairment using regional cerebral blood Xow SPECT
-
Hirao K. The prediction of rapid conversion to Alzheimer's disease in mild cognitive impairment using regional cerebral blood Xow SPECT. Neuroimage 2005, 28:1014-1021.
-
(2005)
Neuroimage
, vol.28
, pp. 1014-1021
-
-
Hirao, K.1
-
91
-
-
3242698677
-
Ictal SPECT analysis in epilepsy-Subtraction and statistical parametric mapping techniques
-
Knowlton R.C. Ictal SPECT analysis in epilepsy-Subtraction and statistical parametric mapping techniques. Neurology 2004, 63:10-15.
-
(2004)
Neurology
, vol.63
, pp. 10-15
-
-
Knowlton, R.C.1
-
92
-
-
0037255433
-
Neuroimaging in cerebrovascular disorders: measurement of cerebral physiology after stroke and assessment of stroke recovery
-
Mountz J.M., Liu H.G., Deutsch G. Neuroimaging in cerebrovascular disorders: measurement of cerebral physiology after stroke and assessment of stroke recovery. Semin. Nucl. Med. 2003, 33:56-76.
-
(2003)
Semin. Nucl. Med.
, vol.33
, pp. 56-76
-
-
Mountz, J.M.1
Liu, H.G.2
Deutsch, G.3
-
93
-
-
0035026142
-
Demonstration of positional posterior circulation cerebral ischemia on cerebral blood Xow SPECT
-
Shuke N. Demonstration of positional posterior circulation cerebral ischemia on cerebral blood Xow SPECT. Clin. Nucl. Med. 2001, 26:559-560.
-
(2001)
Clin. Nucl. Med.
, vol.26
, pp. 559-560
-
-
Shuke, N.1
-
94
-
-
0031713525
-
Noninvasive quantiWcation of cerebral blood Xow using oxygen-15-water and a dual-PET system
-
Iida H. Noninvasive quantiWcation of cerebral blood Xow using oxygen-15-water and a dual-PET system. J. Nucl. Med. 1998, 38:1789-1798.
-
(1998)
J. Nucl. Med.
, vol.38
, pp. 1789-1798
-
-
Iida, H.1
-
95
-
-
84882555180
-
Assessment of myocardial viability in dysfunctional myocardium
-
Churchill Livingstone, P.J. Ell, S.S. Gambhir (Eds.)
-
Sivaratnam D.A., Bonow R.O., KalV V. Assessment of myocardial viability in dysfunctional myocardium. Nuclear Medicine in Clinical Diagnosis and Treatment 2004, 1159-1170. Churchill Livingstone. 3rd ed. P.J. Ell, S.S. Gambhir (Eds.).
-
(2004)
Nuclear Medicine in Clinical Diagnosis and Treatment
, pp. 1159-1170
-
-
Sivaratnam, D.A.1
Bonow, R.O.2
KalV, V.3
-
96
-
-
33644855976
-
Imaging techniques in nuclear cardiology for the assessment of myocardial viability
-
Slart R.H.J.A. Imaging techniques in nuclear cardiology for the assessment of myocardial viability. Int. J. Cardiovasc. Imaging 2006, 22.
-
(2006)
Int. J. Cardiovasc. Imaging
, vol.22
-
-
Slart, R.H.J.A.1
-
97
-
-
0030136750
-
Three-dimensional correction for spillover and recovery of myocardial PET images
-
Nuyts J. Three-dimensional correction for spillover and recovery of myocardial PET images. J. Nucl. Med. 1996, 37:767-774.
-
(1996)
J. Nucl. Med.
, vol.37
, pp. 767-774
-
-
Nuyts, J.1
-
99
-
-
2642532097
-
Accuracy of a method using short inhalation of 15O-O2 for measuring cerebral oxygen extraction fraction with PET in healthy humans
-
Hattori N. Accuracy of a method using short inhalation of 15O-O2 for measuring cerebral oxygen extraction fraction with PET in healthy humans. J. Nucl. Med. 2004, 45:765-770.
-
(2004)
J. Nucl. Med.
, vol.45
, pp. 765-770
-
-
Hattori, N.1
-
100
-
-
0019141576
-
Quantitative measurement of regional cerebral blood Xow and oxygen metabolism in man using 15O and positron emission tomography
-
Frackowiak R.S. Quantitative measurement of regional cerebral blood Xow and oxygen metabolism in man using 15O and positron emission tomography. J. Comput. Assist. Tomog. 1980, 4:727-736.
-
(1980)
J. Comput. Assist. Tomog.
, vol.4
, pp. 727-736
-
-
Frackowiak, R.S.1
-
101
-
-
0021045980
-
Correction for the presence of intravascular oxygen-15 in the steady-state technique for measuring regional oxygen extraction ratio in the brain: 1
-
Lammertsma A.A., Jones T. Correction for the presence of intravascular oxygen-15 in the steady-state technique for measuring regional oxygen extraction ratio in the brain: 1. Description of the method. J. Cereb. Blood Flow Metab. 1983, 3:416-424.
-
(1983)
Description of the method. J. Cereb. Blood Flow Metab.
, vol.3
, pp. 416-424
-
-
Lammertsma, A.A.1
Jones, T.2
-
102
-
-
0023608447
-
Cerebral blood volume measured with inhaled C15O and positron emission tomography
-
Martin W.R., Powers W.J., Raichle M.E. Cerebral blood volume measured with inhaled C15O and positron emission tomography. J. Cereb. Blood Flow Metab. 1987, 7:421-426.
-
(1987)
J. Cereb. Blood Flow Metab.
, vol.7
, pp. 421-426
-
-
Martin, W.R.1
Powers, W.J.2
Raichle, M.E.3
-
103
-
-
0021355477
-
Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography
-
Mintun M.A. Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography. J. Nucl. Med. 1984, 25:177-187.
-
(1984)
J. Nucl. Med.
, vol.25
, pp. 177-187
-
-
Mintun, M.A.1
-
104
-
-
0027317388
-
Modeling approach to eliminate the need to separate arterial plasma in oxygen-15 inhalation positron emission tomography
-
Iida H., Jones T., Miura S. Modeling approach to eliminate the need to separate arterial plasma in oxygen-15 inhalation positron emission tomography. J. Nucl. Med. 1993, 34:1333-1340.
-
(1993)
J. Nucl. Med.
, vol.34
, pp. 1333-1340
-
-
Iida, H.1
Jones, T.2
Miura, S.3
-
105
-
-
0036653912
-
Evaluation of a commercial PET tomography-based system for the quantitative assessment of rCBF, rOEF and rCMRO2 by using sequential administration of 15O-labe
-
Shidahara M. Evaluation of a commercial PET tomography-based system for the quantitative assessment of rCBF, rOEF and rCMRO2 by using sequential administration of 15O-labe. Ann. Nucl. Med. 2002, 16:317-327.
-
(2002)
Ann. Nucl. Med.
, vol.16
, pp. 317-327
-
-
Shidahara, M.1
-
106
-
-
24944544834
-
Rapid quantitative measurement of CMRO2 and CBF by dual administration of 15O-labled oxygen and water during a single PETscan-A validation study and error ana
-
Kudomi N. Rapid quantitative measurement of CMRO2 and CBF by dual administration of 15O-labled oxygen and water during a single PETscan-A validation study and error ana. J. Cereb. Blood Flow Metab. 2005, 25:1209-1224.
-
(2005)
J. Cereb. Blood Flow Metab.
, vol.25
, pp. 1209-1224
-
-
Kudomi, N.1
-
107
-
-
0023221917
-
Delineation of myocardial oxygen utilization with carbon-11-labeled acetate
-
Brown M. Delineation of myocardial oxygen utilization with carbon-11-labeled acetate. Circulation 1987, 76:687-696.
-
(1987)
Circulation
, vol.76
, pp. 687-696
-
-
Brown, M.1
-
108
-
-
0024466543
-
Regional myocardial oxygen consumption determined noninvasively in humans with [1-11C]acetate and dynamic positron tomography
-
Armbrecht J.J. Regional myocardial oxygen consumption determined noninvasively in humans with [1-11C]acetate and dynamic positron tomography. Circulation 1989, 80:864-872.
-
(1989)
Circulation
, vol.80
, pp. 864-872
-
-
Armbrecht, J.J.1
-
109
-
-
0034745220
-
Use of [11C]acetate and [15O]O2 PET for the assessment of myocardial oxygen utilization in patients with chronic myocardial infraction
-
Ukkonen H. Use of [11C]acetate and [15O]O2 PET for the assessment of myocardial oxygen utilization in patients with chronic myocardial infraction. Eur. J. Nucl. Med. 2001, 28:334-339.
-
(2001)
Eur. J. Nucl. Med.
, vol.28
, pp. 334-339
-
-
Ukkonen, H.1
-
110
-
-
84882472954
-
Positron emission tomography
-
Churchill Livingstone, P.J. Ell, S.S. Gambhir (Eds.)
-
Camici P.G. Positron emission tomography. Nuclear Medicine in Clinical Diagnosis and Treatment 2004, 1075-1091. Churchill Livingstone. 3rd ed. P.J. Ell, S.S. Gambhir (Eds.).
-
(2004)
Nuclear Medicine in Clinical Diagnosis and Treatment
, pp. 1075-1091
-
-
Camici, P.G.1
-
111
-
-
0029757173
-
Noninvasive quantiWcation of regional myocardial metabolic rate of oxygen by use of 15O2 inhalation and positron emission tomography: Theory, error analysis,
-
Iida H. Noninvasive quantiWcation of regional myocardial metabolic rate of oxygen by use of 15O2 inhalation and positron emission tomography: Theory, error analysis,. Circulation 1996, 94:792-807.
-
(1996)
Circulation
, vol.94
, pp. 792-807
-
-
Iida, H.1
-
112
-
-
20244376908
-
Progress and promise of FDG-PET imaging for cancer patient management and oncologic drug development
-
KelloV G.J., HoVman J.M., Johnson B. Progress and promise of FDG-PET imaging for cancer patient management and oncologic drug development. Clin. Cancer Res. 2005, 11:2785-2808.
-
(2005)
Clin. Cancer Res.
, vol.11
, pp. 2785-2808
-
-
KelloV, G.J.1
HoVman, J.M.2
Johnson, B.3
-
113
-
-
4544318626
-
Vitro proton magnetic resonance spectroscopic lactate and choline measurements, 18F-FDG uptake, and prognosis in patients with lung adenocarcinoma
-
Guo J. vitro proton magnetic resonance spectroscopic lactate and choline measurements, 18F-FDG uptake, and prognosis in patients with lung adenocarcinoma. J. Nucl. Med. 2004, 45:1334-1339.
-
(2004)
J. Nucl. Med.
, vol.45
, pp. 1334-1339
-
-
Guo, J.1
-
114
-
-
0032888251
-
Prognostic importance of the standardized uptake value on 18F-Xuoro-2-deoxyglucose-positron emission tomography scan in non-small-cell lung cancer: An analysi
-
Vansteenkiste J.F. Prognostic importance of the standardized uptake value on 18F-Xuoro-2-deoxyglucose-positron emission tomography scan in non-small-cell lung cancer: An analysi. J. Clin. Oncol. 1999, 17:3201-3206.
-
(1999)
J. Clin. Oncol.
, vol.17
, pp. 3201-3206
-
-
Vansteenkiste, J.F.1
-
115
-
-
84882504815
-
Small cell lung cancer (SCLS): Glucose metabolism and prognostic signiWcance
-
Brink I. Small cell lung cancer (SCLS): Glucose metabolism and prognostic signiWcance. J. Nucl. Med. 2006, 47(suppl):163-164.
-
(2006)
J. Nucl. Med.
, vol.47
, Issue.SUPPL.
, pp. 163-164
-
-
Brink, I.1
-
116
-
-
0034086992
-
Monitoring response to therapy in cancer using [18F]-2-Xuoro-2-deoxy-D-glucose and positron emission tomography: An overview of diVerent analytical methods
-
Hoekstra C.J. Monitoring response to therapy in cancer using [18F]-2-Xuoro-2-deoxy-D-glucose and positron emission tomography: An overview of diVerent analytical methods. Eur. J. Nucl. Med. 2000, 27:731-743.
-
(2000)
Eur. J. Nucl. Med.
, vol.27
, pp. 731-743
-
-
Hoekstra, C.J.1
-
117
-
-
0034743416
-
On the quantiWcation of [18F]MPPF binding to 5-HT1A receptors in the human brain
-
Passchier J. On the quantiWcation of [18F]MPPF binding to 5-HT1A receptors in the human brain. J. Nucl. Med. 2001, 42:1025-1031.
-
(2001)
J. Nucl. Med.
, vol.42
, pp. 1025-1031
-
-
Passchier, J.1
-
119
-
-
0033791151
-
Measuring receptor occupancy with PET
-
Waard A.van Measuring receptor occupancy with PET. Current Pharm. Des. 2000, 6:1593-1610.
-
(2000)
Current Pharm. Des.
, vol.6
, pp. 1593-1610
-
-
van Waard, A.1
-
120
-
-
33745050401
-
Using positron emission tomography to facilitate CNS drug development
-
Lee C.-M., Farde L. Using positron emission tomography to facilitate CNS drug development. Trends Pharmacol. Sci. 2006, 27:310-315.
-
(2006)
Trends Pharmacol. Sci.
, vol.27
, pp. 310-315
-
-
Lee, C.-M.1
Farde, L.2
-
121
-
-
84882517740
-
Visual analysis of 11C-PIB PET and 18F-FDG PET for detection of Alzheimer's disease
-
Rowe C.C. Visual analysis of 11C-PIB PET and 18F-FDG PET for detection of Alzheimer's disease. J. Nucl. Med. 2006, 47(suppl):75.
-
(2006)
J. Nucl. Med.
, pp. 75
-
-
Rowe, C.C.1
|