메뉴 건너뛰기




Volumn 1, Issue 4, 1997, Pages 243-254

A technique for extracting physiological parameters and the required input fuction smultaneously from PET iage masurements: Theory and smulation sudy

Author keywords

Modeling; Noninvasive measurement; Positron emission tomography (pet); Simulation

Indexed keywords

GLUCOSE;

EID: 0031282828     PISSN: 10897771     EISSN: None     Source Type: Journal    
DOI: 10.1109/4233.681168     Document Type: Article
Times cited : (149)

References (20)
  • 2
    • 0018582265 scopus 로고
    • Tomographie measurement of local cerebral glucose metabolic rate in humans with (F-18)2-fluoro-2-deoxy-D-glucose: Validation of method
    • M. E. Phelps, S. C. Huang, E. J. Huffman, C. Selin, L. Sokoloff, and D. E. Kühl, "Tomographie measurement of local cerebral glucose metabolic rate in humans with (F-18)2-fluoro-2-deoxy-D-glucose: Validation of method," Ann. Neural., vol. 6, pp. 371-388, 1979.
    • (1979) Ann. Neural. , vol.6 , pp. 371-388
    • Phelps, M.E.1    Huang, S.C.2    Huffman, E.J.3    Selin, C.4    Sokoloff, L.5    Kühl, D.E.6
  • 3
    • 0026841971 scopus 로고
    • Editorial: A bloody future for clinical PET
    • J. Correia, "Editorial: A bloody future for clinical PET," J. Nucl. Med., vol. 33, pp. 620-622, 1992.
    • (1992) J. Nucl. Med. , vol.33 , pp. 620-622
    • Correia, J.1
  • 5
    • 0005557888 scopus 로고    scopus 로고
    • Absolute cerebral blood flow with 15O-water and PET: Determination without a measured input function
    • R. Myers, V. Cunningham, D. Bailey, and T. Jones, Eds. San Diego, CA: Academic
    • R. E. Carson, Y. Yan, and R. Shrager, "Absolute cerebral blood flow with 15O-water and PET: Determination without a measured input function," Quantification of Brain Function Using PET, R. Myers, V. Cunningham, D. Bailey, and T. Jones, Eds. San Diego, CA: Academic, 1996, pp. 185-190.
    • (1996) Quantification of Brain Function Using PET , pp. 185-190
    • Carson, R.E.1    Yan, Y.2    Shrager, R.3
  • 6
    • 0021062116 scopus 로고
    • Measurement of regional tissue and blood radiotracer concentrations from serial tomographic images of the heart
    • E. Henze, S. C. Huang, O. Ratib, E. Huffman, M. E. Phelps, and H. R. Schelbert, "Measurement of regional tissue and blood radiotracer concentrations from serial tomographic images of the heart," J. Nucl. Med., vol. 24, pp. 987-996, 1983.
    • (1983) J. Nucl. Med. , vol.24 , pp. 987-996
    • Henze, E.1    Huang, S.C.2    Ratib, O.3    Huffman, E.4    Phelps, M.E.5    Schelbert, H.R.6
  • 7
    • 6844252219 scopus 로고
    • A method for correction myocardium to blood pool spillover in dynamic cardiac PET EDO studies
    • K. P. Lin, S. C. Huang, Y. Choi, R. Brunken, H. Scheiben, and M. E. Phelps, "A method for correction myocardium to blood pool spillover in dynamic cardiac PET EDO studies," J. Nucl. Med., vol. 33, p. 882, 1992.
    • (1992) J. Nucl. Med. , vol.33 , pp. 882
    • Lin, K.P.1    Huang, S.C.2    Choi, Y.3    Brunken, R.4    Scheiben, H.5    Phelps, M.E.6
  • 8
    • 0025740932 scopus 로고
    • The effects of measurement errors in plasma radioactivity curve on parameter estimation in positron emission tomography
    • K. Chen, S. C. Huang, and D. C. Yu, "The effects of measurement errors in plasma radioactivity curve on parameter estimation in positron emission tomography," Phys. Med. Biol., vol. 36, pp. 1183-1200, 1991.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 1183-1200
    • Chen, K.1    Huang, S.C.2    Yu C, D.3
  • 9
    • 0027572378 scopus 로고
    • Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography
    • D. Feng, S. C. Huang, and X. Wang, "Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography," Int. J. Biomed. Comput, vol. 32, pp. 95-110, 1993.
    • (1993) Int. J. Biomed. Comput , vol.32 , pp. 95-110
    • Feng, D.1    Huang, S.C.2    Wang, X.3
  • 10
    • 0021322753 scopus 로고
    • Alternative approach to single-scan estimation of cerebral glucose metabolic rate using glucose analogs, with particular application to ischemia
    • G. D. Hutchins, J. E. Holden, R. A. Koeppe, J. R. Halama, S. J. Gatley, and R. J. Nickles, "Alternative approach to single-scan estimation of cerebral glucose metabolic rate using glucose analogs, with particular application to ischemia," J. Cereb. Blood Flow Metab., vol. 4, pp. 35-410, 1984.
    • (1984) J. Cereb. Blood Flow Metab. , vol.4 , pp. 35-410
    • Hutchins, G.D.1    Holden, J.E.2    Koeppe, R.A.3    Halama, J.R.4    Gatley, S.J.5    Nickles, R.J.6
  • 11
    • 0027161814 scopus 로고
    • Noninvasive quantitative fluorodeoxyglucose PET studies with an estimated input function derived from a population-based arterial blood curve
    • S. Takikawa, V. Dhawam, P. Spetsieris, W. Robeson, T. Chaly, R. Dahl, D. Margouleff, and D. Eidelberg, "Noninvasive quantitative fluorodeoxyglucose PET studies with an estimated input function derived from a population-based arterial blood curve," Radiology, vol. 188, pp. 131-136, 1993.
    • (1993) Radiology , vol.188 , pp. 131-136
    • Takikawa, S.1    Dhawam, V.2    Spetsieris, P.3    Robeson, W.4    Chaly, T.5    Dahl, R.6    Margouleff, D.7    Eidelberg, D.8
  • 12
    • 0029146606 scopus 로고
    • An improved method to calculate cerebral metabolic rates of glucose using PET
    • R. L. Phillips, C. Y. Chen, D. F. Wong, and E. D. London, "An improved method to calculate cerebral metabolic rates of glucose using PET," J. Nucl. Med., vol. 36, pp. 1668-1679, 1995.
    • (1995) J. Nucl. Med. , vol.36 , pp. 1668-1679
    • Phillips, R.L.1    Chen, C.Y.2    Wong, D.F.3    London, E.D.4
  • 13
    • 0028533976 scopus 로고
    • A computer simulation study on the input function sampling schedules in tracer kinetic modeling with positron emission tomography (PET)
    • D. Feng, X. Wang, and H. Yan, "A computer simulation study on the input function sampling schedules in tracer kinetic modeling with positron emission tomography (PET)," Comput. Methods Program. Biomed., vol. 45, pp. 175-186, 1994.
    • (1994) Comput. Methods Program. Biomed. , vol.45 , pp. 175-186
    • Feng, D.1    Wang, X.2    Yan, H.3
  • 14
    • 0027530768 scopus 로고
    • A computer simulation study on the effects of input function measurement noise in tracer kinetic modeling with positron emission tomography (PET)
    • D. Feng and X. Wang, "A computer simulation study on the effects of input function measurement noise in tracer kinetic modeling with positron emission tomography (PET)," Comput. Biol. Med., vol. 23, pp. 57-68, 1993.
    • (1993) Comput. Biol. Med. , vol.23 , pp. 57-68
    • Feng, D.1    Wang, X.2
  • 15
    • 0030110831 scopus 로고    scopus 로고
    • A new double modeling approach for dynamic cardiac PET studies using noise and spillover contaminated LV measurements
    • Mar.
    • D. Feng, X. Li, and S. C. Huang, "A new double modeling approach for dynamic cardiac PET studies using noise and spillover contaminated LV measurements," IEEE Trans. Biomed. Eng., vol. 43, pp. 319-327, Mar. 1996.
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , pp. 319-327
    • Feng, D.1    Li, X.2    Huang, S.C.3
  • 16
    • 0029291712 scopus 로고
    • A method for biomédical system modeling and physiological parameter estimation using indirectly measured input functions
    • D. Feng and X. Wang, "A method for biomédical system modeling and physiological parameter estimation using indirectly measured input functions," Int. J. Syst. Sei., vol. 26, pp. 723-739, 1995.
    • (1995) Int. J. Syst. Sei. , vol.26 , pp. 723-739
    • Feng, D.1    Wang, X.2
  • 17
    • 0017368491 scopus 로고
    • The [14C] deoxyglucose method for the measurement of local cerebral glucose utilization: Theory, procedure and normal values in the conscious and anesthetized albino rat
    • L. Sokoloff, M. Reivich, C. Kennedy, M. H. DesRosiers, C. S. Patlak, K. D. Pettigrew, D. Kakurada, and M. Shinohara, "The [14C] deoxyglucose method for the measurement of local cerebral glucose utilization: Theory, procedure and normal values in the conscious and anesthetized albino rat," J. Neurochem., vol. 28, pp. 897-916, 1977.
    • (1977) J. Neurochem. , vol.28 , pp. 897-916
    • Sokoloff, L.1    Reivich, M.2    Kennedy, C.3    Desrosiers, M.H.4    Patlak, C.S.5    Pettigrew, K.D.6    Kakurada, D.7    Shinohara, M.8
  • 18
    • 0022586370 scopus 로고
    • Effects of temporal sampling, glucose metabolic rates, and disruptions of the blood-brain barrier on the FDG model with and without a vascular compartment: Studies in human brain tumors with PET
    • R. A. Hawkins, M. E. Phelps, and S. C. Huang, "Effects of temporal sampling, glucose metabolic rates, and disruptions of the blood-brain barrier on the FDG model with and without a vascular compartment: Studies in human brain tumors with PET," J. Cereb. Blood Flow Metab., vol. 6, pp. 170-183, 1986.
    • (1986) J. Cereb. Blood Flow Metab. , vol.6 , pp. 170-183
    • Hawkins, R.A.1    Phelps, M.E.2    Huang, S.C.3
  • 19
    • 0000873069 scopus 로고
    • A method for the solution of certain nonlinear problems in least squares
    • K. Levenberg, "A method for the solution of certain nonlinear problems in least squares," Q. Appt. Math., vol. 2, pp. 164-168, 1944.
    • (1944) Q. Appt. Math. , vol.2 , pp. 164-168
    • Levenberg, K.1
  • 20
    • 0000169232 scopus 로고
    • An algorithm for least squares estimation of nonlinear parameters
    • D. W. Marquardt, "An algorithm for least squares estimation of nonlinear parameters," J. Soc. Ind. Appl. Math., vol. 2, pp. 431-441, 1963.
    • (1963) J. Soc. Ind. Appl. Math. , vol.2 , pp. 431-441
    • Marquardt, D.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.