-
1
-
-
0003691941
-
-
International Commission on Radiation Units and Measurements, "," ICRU Report No. 59 (ICRU Publications, Washington, DC).
-
International Commission on Radiation Units and Measurements, " Clinical proton dosimetry-Part I: Beam production, beam delivery and measurement of absorbed dose.," ICRU Report No. 59 (ICRU Publications, Washington, DC, 1998).
-
(1998)
Clinical Proton Dosimetry - Part I: Beam Production, Beam Delivery and Measurement of Absorbed Dose
-
-
-
2
-
-
26344441769
-
-
International Commission on Radiation Units and Measurements, "," ICRU Report No. 64 (ICRU Publications, Washington, DC).
-
International Commission on Radiation Units and Measurements, " Dosimetry of high-energy photon beams based on standards of absorbed dose to water.," ICRU Report No. 64 (ICRU Publications, Washington, DC, 2001).
-
(2001)
Dosimetry of High-energy Photon Beams Based on Standards of Absorbed Dose to Water
-
-
-
3
-
-
77955825747
-
-
International Commission on Radiation Units and Measurements, "," ICRU Report No. 76 (ICRU Publications, Washington, DC).
-
International Commission on Radiation Units and Measurements, " Measurement quality assurance for ionising radiation dosimetry.," ICRU Report No. 76 (ICRU Publications, Washington, DC, 2006).
-
(2006)
Measurement Quality Assurance for Ionising Radiation Dosimetry
-
-
-
4
-
-
0345295272
-
Three-dimensional beam scanning for proton therapy
-
10.1016/0167-5087(83)90621-X
-
T. Kanai, K. Kawachi, H. Matsuzawa, and T. Inada, " Three-dimensional beam scanning for proton therapy.," Nucl. Instrum. Methods Phys. Res. A 214, 491-496 (1983). 10.1016/0167-5087(83)90621-X
-
(1983)
Nucl. Instrum. Methods Phys. Res. A
, vol.214
, pp. 491-496
-
-
Kanai, T.1
Kawachi, K.2
Matsuzawa, H.3
Inada, T.4
-
5
-
-
0034897033
-
Magnetically scanned proton therapy beams: Rationales and principles
-
10.1016/S0969-806X(01)00348-6
-
D. Jones and A. Schreuder, " Magnetically scanned proton therapy beams: rationales and principles.," Radiat. Phys. Chem. 61, 615-618 (2001). 10.1016/S0969-806X(01)00348-6
-
(2001)
Radiat. Phys. Chem.
, vol.61
, pp. 615-618
-
-
Jones, D.1
Schreuder, A.2
-
6
-
-
0027609090
-
Magnetic scanning system for heavy ion therapy
-
10.1016/0168-9002(93)91335-K
-
T. Haberer, W. Becher, D. Schardt, and G. Kraft, " Magnetic scanning system for heavy ion therapy.," Nucl. Instrum. Methods Phys. Res. A 330, 296-305 (1993). 10.1016/0168-9002(93)91335-K
-
(1993)
Nucl. Instrum. Methods Phys. Res. A
, vol.330
, pp. 296-305
-
-
Haberer, T.1
Becher, W.2
Schardt, D.3
Kraft, G.4
-
7
-
-
0345035258
-
A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
-
10.1118/1.598728
-
C. P. Karger, O. Jäkel, G. H. Hartmann, and P. Heeg, " A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions.," Med. Phys. 26, 2125-2132 (1999). 10.1118/1.598728
-
(1999)
Med. Phys.
, vol.26
, pp. 2125-2132
-
-
Karger, C.P.1
Jäkel, O.2
Hartmann, G.H.3
Heeg, P.4
-
8
-
-
4444284161
-
Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the magic cube and the pixel ionization chamber
-
10.1088/0031-9155/49/16/017
-
R. Cirio, E. Garelli, R. Schulte, S. Amerio, A. Boriano, F. Bourhaleb, G. Coutrakon, M. Donetti, S. Giordanengo, P. Koss, E. Madon, F. Marchetto, U. Nastasi, C. Peroni, D. Santuari, A. Sardo, G. Scielzo, M. Stasi, and E. Trevisiol, " Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the magic cube and the pixel ionization chamber.," Phys. Med. Biol. 49, 3713-3724 (2004). 10.1088/0031-9155/49/16/ 017
-
(2004)
Phys. Med. Biol.
, vol.49
, pp. 3713-3724
-
-
Cirio, R.1
Garelli, E.2
Schulte, R.3
Amerio, S.4
Boriano, A.5
Bourhaleb, F.6
Coutrakon, G.7
Donetti, M.8
Giordanengo, S.9
Koss, P.10
Madon, E.11
Marchetto, F.12
Nastasi, U.13
Peroni, C.14
Santuari, D.15
Sardo, A.16
Scielzo, G.17
Stasi, M.18
Trevisiol, E.19
-
9
-
-
77749341600
-
Evaluation of a biplanar diode array dosimeter for quality assurance of step-and-shoot IMRT
-
10.1120/jacmv10i4.3080
-
V. Feygelman, K. Forster, D. Opp, and G. Nilsson, " Evaluation of a biplanar diode array dosimeter for quality assurance of step-and-shoot IMRT.," J. Appl. Clin. Med. Phys. 10, 64-78 (2009). 10.1120/jacmp.v10i4. 3080
-
(2009)
J. Appl. Clin. Med. Phys.
, vol.10
, pp. 64-78
-
-
Feygelman, V.1
Forster, K.2
Opp, D.3
Nilsson, G.4
-
10
-
-
79960552723
-
Evaluation of a new VMAT QA device, or the "x" and "o" array geometries
-
V. Feygelman, G. Zhang, C. Stevens, and B. Nelms, " Evaluation of a new VMAT QA device, or the "X" and "O" array geometries.," J. Appl. Clin. Med. Phys. 12, 146-168 (2011).
-
(2011)
J. Appl. Clin. Med. Phys.
, vol.12
, pp. 146-168
-
-
Feygelman, V.1
Zhang, G.2
Stevens, C.3
Nelms, B.4
-
11
-
-
52049100092
-
A literature review of electronic portal imaging for radiotherapy dosimetry
-
10.1016/j.radonc.2008.07.008
-
W. van Elmpt, L. McDermott, S. Nijsten, M. Wendling, P. Lambin, and B. Mijnheer, " A literature review of electronic portal imaging for radiotherapy dosimetry.," Radiother. Oncol. 88, 289-309 (2008). 10.1016/j.radonc.2008.07.008
-
(2008)
Radiother. Oncol.
, vol.88
, pp. 289-309
-
-
Van Elmpt, W.1
McDermott, L.2
Nijsten, S.3
Wendling, M.4
Lambin, P.5
Mijnheer, B.6
-
12
-
-
0026570956
-
A review of electronic portal imaging devices (EPIDs)
-
10.1118/1.596878
-
A. L. Boyer, L. Antonuk, A. Fenster, M. V. Herk, H. Meertens, P. Munro, L. E. Reinstein, and J. Wong, " A review of electronic portal imaging devices (EPIDs).," Med. Phys. 19, 1-16 (1992). 10.1118/1.596878
-
(1992)
Med. Phys.
, vol.19
, pp. 1-16
-
-
Boyer, A.L.1
Antonuk, L.2
Fenster, A.3
Herk, M.V.4
Meertens, H.5
Munro, P.6
Reinstein, L.E.7
Wong, J.8
-
13
-
-
0032064296
-
Amorphous silicon X-ray detectors
-
10.1016/S0022-3093(98)00316-0
-
M. Hoheisel, M. Arques, J. Chabbal, C. Chaussat, T. Ducourant, G. Hahm, H. Horbaschek, R. Schulz, and M. Spahn, " Amorphous silicon X-ray detectors.," J. Non-Cryst. Solids 227-230, 1300-1305 (1998). 10.1016/S0022-3093(98)00316-0
-
(1998)
J. Non-Cryst. Solids
, vol.227-230
, pp. 1300-1305
-
-
Hoheisel, M.1
Arques, M.2
Chabbal, J.3
Chaussat, C.4
Ducourant, T.5
Hahm, G.6
Horbaschek, H.7
Schulz, R.8
Spahn, M.9
-
14
-
-
0032807993
-
Applications of thermoluminescence dosimetry in medicine
-
10.1093/oxfordjournals.rpd.a032865
-
T. Kron, " Applications of thermoluminescence dosimetry in medicine.," Radiat. Prot. Dosim. 85, 333-340 (1999). 10.1093/ oxfordjournals.rpd.a032865
-
(1999)
Radiat. Prot. Dosim.
, vol.85
, pp. 333-340
-
-
Kron, T.1
-
15
-
-
0029823903
-
TLD array for precise dose measurements in stereotactic radiation techniques
-
10.1088/0031-9155/41/12/007
-
A. Ertl, R. F. E. Hartl, M. Zehetmayer, K. Kitz, and W. Griffitt, " TLD array for precise dose measurements in stereotactic radiation techniques.," Phys. Med. Biol. 41, 2679-2686 (1996). 10.1088/0031-9155/41/ 12/007
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 2679-2686
-
-
Ertl, A.1
Hartl, R.F.E.2
Zehetmayer, M.3
Kitz, K.4
Griffitt, W.5
-
16
-
-
0042331009
-
Radiochromic film for medical radiation dosimetry
-
10.1016/S0927-796X(03)00034-2
-
M. J. Butson, P. K. Yu, T. Cheung, and P. Metcalfe, " Radiochromic film for medical radiation dosimetry.," Mater. Sci. Eng. R. 41, 61-120 (2003). 10.1016/S0927-796X(03)00034-2
-
(2003)
Mater. Sci. Eng. R.
, vol.41
, pp. 61-120
-
-
Butson, M.J.1
Yu, P.K.2
Cheung, T.3
Metcalfe, P.4
-
17
-
-
34248517496
-
Radiochromic film dosimetry
-
10.1016/j.radmeas.2007.01.007
-
C. G. Soares, " Radiochromic film dosimetry.," Radiat. Meas. 41 (S1), S100-S116 (2006). 10.1016/j.radmeas.2007.01.007
-
(2006)
Radiat. Meas.
, vol.41
, Issue.S1
-
-
Soares, C.G.1
-
18
-
-
0030756665
-
Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery
-
10.1088/0031-9155/42/10/003
-
S. M. Vatnitsky, R. W. M. Schulte, R. Galindo, H. J. Meinass, and D. W. Miller, " Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery.," Phys. Med. Biol. 42, 1887-1898 (1997). 10.1088/0031-9155/42/10/003
-
(1997)
Phys. Med. Biol.
, vol.42
, pp. 1887-1898
-
-
Vatnitsky, S.M.1
Schulte, R.W.M.2
Galindo, R.3
Meinass, H.J.4
Miller, D.W.5
-
19
-
-
76849111203
-
Polymer gel dosimetry
-
10.1088/0031-9155/55/5/R01
-
C. Baldock, Y. D. Deene, S. Doran, G. Ibbott, A. Jirasek, M. Lepage, K. B. McAuley, M. Oldham, and L. J. Schreiner, " Polymer gel dosimetry.," Phys. Med. Biol. 55, R1-R63 (2010). 10.1088/0031-9155/55/5/R01
-
(2010)
Phys. Med. Biol.
, vol.55
-
-
Baldock, C.1
Deene, Y.D.2
Doran, S.3
Ibbott, G.4
Jirasek, A.5
Lepage, M.6
McAuley, K.B.7
Oldham, M.8
Schreiner, L.J.9
-
20
-
-
84874330669
-
High-energy radiation monitoring based on radio-fluorogenic co-polymerization III: Fluorescent images of the cross-section and depth-dose profile of a 3 MV electronbeam
-
10.1016/j.radphyschem.2012.06.031
-
J. Warman, M. de Haas, L. Luthjens, and M. Hom, " High-energy radiation monitoring based on radio-fluorogenic co-polymerization III: Fluorescent images of the cross-section and depth-dose profile of a 3 MV electronbeam.," Radiat. Phys. Chem. 84, 129-135 (2013). 10.1016/j.radphyschem.2012.06.031
-
(2013)
Radiat. Phys. Chem.
, vol.84
, pp. 129-135
-
-
Warman, J.1
De Haas, M.2
Luthjens, L.3
Hom, M.4
-
21
-
-
22544440841
-
Precise radiochromic film dosimetry using a flat-bed document scanner
-
10.1118/1.1929253
-
S. Devic, J. Seuntjens, E. Sham, E. B. Podgorsak, C. R. Schmidtlein, A. S. Kirov, and C. G. Soares, " Precise radiochromic film dosimetry using a flat-bed document scanner.," Med. Phys. 32, 2245-2253 (2005). 10.1118/1.1929253
-
(2005)
Med. Phys.
, vol.32
, pp. 2245-2253
-
-
Devic, S.1
Seuntjens, J.2
Sham, E.3
Podgorsak, E.B.4
Schmidtlein, C.R.5
Kirov, A.S.6
Soares, C.G.7
-
22
-
-
84881623292
-
High-resolution optical tomography for 3D radiation dosimetry with radiochromic gels
-
10.1088/1742-6596/3/1/042
-
M. A. Bero and W. B. Gilboy, " High-resolution optical tomography for 3D radiation dosimetry with radiochromic gels.," J. Phys.: Conf. Ser. 3, 261-264 (2004). 10.1088/1742-6596/3/1/042
-
(2004)
J. Phys.: Conf. Ser.
, vol.3
, pp. 261-264
-
-
Bero, M.A.1
Gilboy, W.B.2
-
23
-
-
0034912917
-
High resolution gel-dosimetry by optical-CT and MR scanning
-
10.1118/1.1380430
-
M. Oldham, J. H. Siewerdsen, A. Shetty, and D. A. Jaffray, " High resolution gel-dosimetry by optical-CT and MR scanning.," Med. Phys. 28, 1436-1445 (2001). 10.1118/1.1380430
-
(2001)
Med. Phys.
, vol.28
, pp. 1436-1445
-
-
Oldham, M.1
Siewerdsen, J.H.2
Shetty, A.3
Jaffray, D.A.4
-
24
-
-
33745234792
-
Charge coupled device camera-scintillator system for two dimensional proton dose measurements
-
10.1143/JJAP.45.5297
-
J.-W. Kim, J.-W. Kwon, J. Lee, and Y.-K. Kim, " Charge coupled device camera-scintillator system for two dimensional proton dose measurements.," Jpn. J. Appl. Phys. 45, 5297-5300 (2006). 10.1143/JJAP.45.5297
-
(2006)
Jpn. J. Appl. Phys.
, vol.45
, pp. 5297-5300
-
-
Kim, J.-W.1
Kwon, J.-W.2
Lee, J.3
Kim, Y.-K.4
-
25
-
-
0037147840
-
Applications in radiation therapy of a scintillating screen viewed by a CCD camera
-
10.1016/S0168-9002(01)01782-X
-
J. M. Schippers, S. N. Boon, and P. van Luijk, " Applications in radiation therapy of a scintillating screen viewed by a CCD camera.," Nucl. Instrum. Methods Phys. Res. A 477, 480-485 (2002). 10.1016/S0168-9002(01)01782- X
-
(2002)
Nucl. Instrum. Methods Phys. Res. A
, vol.477
, pp. 480-485
-
-
Schippers, J.M.1
Boon, S.N.2
Van Luijk, P.3
-
26
-
-
82755198685
-
A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy
-
10.1118/1.3664007
-
M. Guillot, L. Beaulieu, L. Archambault, S. Beddar, and L. Gingras, " A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy.," Med. Phys. 38, 6763-6774 (2011). 10.1118/1.3664007
-
(2011)
Med. Phys.
, vol.38
, pp. 6763-6774
-
-
Guillot, M.1
Beaulieu, L.2
Archambault, L.3
Beddar, S.4
Gingras, L.5
-
27
-
-
65449132380
-
Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams
-
10.1118/1.3117583
-
S. Beddar, L. Archambault, N. Sahoo, F. Poenisch, G. T. Chen, M. T. Gillin, and R. Mohan, " Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams.," Med. Phys. 36, 1736-1743 (2009). 10.1118/1.3117583
-
(2009)
Med. Phys.
, vol.36
, pp. 1736-1743
-
-
Beddar, S.1
Archambault, L.2
Sahoo, N.3
Poenisch, F.4
Chen, G.T.5
Gillin, M.T.6
Mohan, R.7
-
28
-
-
84857804819
-
Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system
-
10.1118/1.3681948
-
L. Archambault, F. Poenisch, N. Sahoo, D. Robertson, A. Lee, M. T. Gillin, R. Mohan, and S. Beddar, " Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system.," Med. Phys. 39, 1239-1246 (2012). 10.1118/1.3681948
-
(2012)
Med. Phys.
, vol.39
, pp. 1239-1246
-
-
Archambault, L.1
Poenisch, F.2
Sahoo, N.3
Robertson, D.4
Lee, A.5
Gillin, M.T.6
Mohan, R.7
Beddar, S.8
-
29
-
-
84864672449
-
High resolution 2D dose measurement device based on a few long scintillating fibers and tomographic reconstruction
-
10.1118/1.4736526
-
M. Goulet, L. Archambault, L. Beaulieu, and L. Gingras, " High resolution 2D dose measurement device based on a few long scintillating fibers and tomographic reconstruction.," Med. Phys. 39, 4840-4849 (2012). 10.1118/1.4736526
-
(2012)
Med. Phys.
, vol.39
, pp. 4840-4849
-
-
Goulet, M.1
Archambault, L.2
Beaulieu, L.3
Gingras, L.4
-
30
-
-
21344459506
-
106Ru eye plaque applicator
-
10.1088/0031-9155/50/13/007
-
106Ru eye plaque applicator.," Phys. Med. Biol. 50, 3063-3081 (2005). 10.1088/0031-9155/50/ 13/007
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 3063-3081
-
-
Kirov, A.S.1
Piao, J.Z.2
Mathur, N.K.3
Miller, T.R.4
Devic, S.5
Trichter, S.6
Zaider, M.7
Soares, C.G.8
Losasso, T.9
-
31
-
-
6244231820
-
Energetic proton generation in ultra-intense laser-solid interactions
-
10.1063/1.1333697
-
S. C. Wilks, A. B. Langdon, T. E. Cowan, M. Roth, M. Singh, S. Hatchett, M. H. Key, D. Pennington, A. MacKinnon, and R. A. Snavely, " Energetic proton generation in ultra-intense laser-solid interactions.," Phys. Plasmas 8, 542-549 (2001). 10.1063/1.1333697
-
(2001)
Phys. Plasmas
, vol.8
, pp. 542-549
-
-
Wilks, S.C.1
Langdon, A.B.2
Cowan, T.E.3
Roth, M.4
Singh, M.5
Hatchett, S.6
Key, M.H.7
Pennington, D.8
Mackinnon, A.9
Snavely, R.A.10
-
32
-
-
79960104038
-
Preparation of laser-accelerated proton beams for radiobiological applications
-
10.1016/j.nima.2010.12.065
-
J. Metzkes, T. Cowan, L. Karsch, S. Kraft, J. Pawelke, C. Richter, T. Richter, K. Zeil, and U. Schramm, " Preparation of laser-accelerated proton beams for radiobiological applications.," Nucl. Instrum. Methods Phys. Res. A 653, 172-175 (2011). 10.1016/j.nima.2010.12.065
-
(2011)
Nucl. Instrum. Methods Phys. Res. A
, vol.653
, pp. 172-175
-
-
Metzkes, J.1
Cowan, T.2
Karsch, L.3
Kraft, S.4
Pawelke, J.5
Richter, C.6
Richter, T.7
Zeil, K.8
Schramm, U.9
-
33
-
-
33644633451
-
Within the next decade conventional cyclotrons for proton radiotherapy will become obsolete and replaced by far less expensive machines using compact laser systems for the acceleration of the protons
-
10.1118/1.2150220
-
C.-M. C. Ma, R. L. Maughan, and C. G. Orton, " Within the next decade conventional cyclotrons for proton radiotherapy will become obsolete and replaced by far less expensive machines using compact laser systems for the acceleration of the protons.," Med. Phys. 33, 571-573 (2006). 10.1118/1.2150220
-
(2006)
Med. Phys.
, vol.33
, pp. 571-573
-
-
Ma, C.-M.C.1
Maughan, R.L.2
Orton, C.G.3
-
34
-
-
0036912840
-
Particle in cell simulation of laser-accelerated proton beams for radiation therapy
-
10.1118/1.1521122
-
E. Fourkal, B. Shahine, M. Ding, J. S. Li, T. Tajima, and C.-M. Ma, " Particle in cell simulation of laser-accelerated proton beams for radiation therapy.," Med. Phys. 29, 2788-2798 (2002). 10.1118/1.1521122
-
(2002)
Med. Phys.
, vol.29
, pp. 2788-2798
-
-
Fourkal, E.1
Shahine, B.2
Ding, M.3
Li, J.S.4
Tajima, T.5
Ma, C.-M.6
-
35
-
-
77956601717
-
Dose-dependent biological damage of tumour cells by laser-accelerated proton beams
-
10.1088/1367-2630/12/8/085003
-
S. D. Kraft, C. Richter, K. Zeil, M. Baumann, E. Beyreuther, S. Bock, M. Bussmann, T. E. Cowan, Y. Dammene, W. Enghardt, U. Helbig, L. Karsch, T. Kluge, L. Laschinsky, E. Lessmann, J. Metzkes, D. Naumburger, R. Sauerbrey, M. Schürer, M. Sobiella, J. Woithe, U. Schramm, and J. Pawelke, " Dose-dependent biological damage of tumour cells by laser-accelerated proton beams.," New J. Phys. 12, 085003 (2010). 10.1088/1367-2630/12/8/085003
-
(2010)
New J. Phys.
, vol.12
, pp. 085003
-
-
Kraft, S.D.1
Richter, C.2
Zeil, K.3
Baumann, M.4
Beyreuther, E.5
Bock, S.6
Bussmann, M.7
Cowan, T.E.8
Dammene, Y.9
Enghardt, W.10
Helbig, U.11
Karsch, L.12
Kluge, T.13
Laschinsky, L.14
Lessmann, E.15
Metzkes, J.16
Naumburger, D.17
Sauerbrey, R.18
Schürer, M.19
Sobiella, M.20
Woithe, J.21
Schramm, U.22
Pawelke, J.23
more..
-
36
-
-
84861651042
-
Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors
-
10.1118/1.3700400
-
L. Karsch, E. Beyreuther, T. Burris-Mog, S. Kraft, C. Richter, K. Zeil, and J. Pawelke, " Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors.," Med. Phys. 39, 2447-2455 (2012). 10.1118/1.3700400
-
(2012)
Med. Phys.
, vol.39
, pp. 2447-2455
-
-
Karsch, L.1
Beyreuther, E.2
Burris-Mog, T.3
Kraft, S.4
Richter, C.5
Zeil, K.6
Pawelke, J.7
-
37
-
-
79952937485
-
A dosimetric system for quantitative cell irradiation experiments with laser-accelerated protons
-
10.1088/0031-9155/56/6/002
-
C. Richter, L. Karsch, Y. Dammene, S. D. Kraft, J. Metzkes, U. Schramm, M. Schürer, M. Sobiella, A. Weber, K. Zeil, and J. Pawelke, " A dosimetric system for quantitative cell irradiation experiments with laser-accelerated protons.," Phys. Med. Biol. 56, 1529-1543 (2011). 10.1088/0031-9155/56/6/002
-
(2011)
Phys. Med. Biol.
, vol.56
, pp. 1529-1543
-
-
Richter, C.1
Karsch, L.2
Dammene, Y.3
Kraft, S.D.4
Metzkes, J.5
Schramm, U.6
Schürer, M.7
Sobiella, M.8
Weber, A.9
Zeil, K.10
Pawelke, J.11
-
38
-
-
34248504862
-
Plastic scintillation dosimetry and its application to radiotherapy
-
10.1016/j.radmeas.2007.01.002
-
A. S. Beddar, " Plastic scintillation dosimetry and its application to radiotherapy.," Radiat. Meas. 41, S124-S133 (2006). 10.1016/j.radmeas. 2007.01.002
-
(2006)
Radiat. Meas.
, vol.41
-
-
Beddar, A.S.1
-
39
-
-
84881622912
-
-
SAINT-GOBAIN
-
SAINT-GOBAIN, " BC-400, BC-404, BC-408, BC-412, BC-416 premium plastic scintillator product data sheet.," 2005.
-
(2005)
BC-400, BC-404, BC-408, BC-412, BC-416 Premium Plastic Scintillator Product Data Sheet
-
-
-
41
-
-
42449118498
-
Characterizing the response of miniature scintillation detectors when irradiated with proton beams
-
10.1088/0031-9155/53/7/004
-
L. Archambault, J. C. Polf, L. Beaulieu, and S. Beddar, " Characterizing the response of miniature scintillation detectors when irradiated with proton beams.," Phys. Med. Biol. 53, 1865-1876 (2008). 10.1088/0031-9155/53/7/004
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 1865-1876
-
-
Archambault, L.1
Polf, J.C.2
Beaulieu, L.3
Beddar, S.4
-
42
-
-
48349139051
-
Availability of a tool using CCD camera-plastic scintillator system in HDR for quality assurance
-
10.1109/NSSMIC.2007.4437272
-
T. Hanada, H. Kojima, M. Ishigami, S. Katsuta, A. Yorozu, T. Otsuka, and K. Maruyama, " Availability of a tool using CCD camera-plastic scintillator system in HDR for quality assurance.," Nucl. Sci. Res. Conf. Ser. 2, 1443-1446 (2007). 10.1109/NSSMIC.2007.4437272
-
(2007)
Nucl. Sci. Res. Conf. Ser.
, vol.2
, pp. 1443-1446
-
-
Hanada, T.1
Kojima, H.2
Ishigami, M.3
Katsuta, S.4
Yorozu, A.5
Otsuka, T.6
Maruyama, K.7
-
43
-
-
0036132789
-
Radiation damage in polyvinyltoluene (PVT)
-
10.1016/S0969-806X(01)00487-X
-
L. Torrisi, " Radiation damage in polyvinyltoluene (PVT).," Radiat. Phys. Chem. 63, 89-92 (2002). 10.1016/S0969-806X(01)00487-X
-
(2002)
Radiat. Phys. Chem.
, vol.63
, pp. 89-92
-
-
Torrisi, L.1
-
44
-
-
0032303631
-
Radiation damage in PVT (polyvinyltoluene) induced by energetic ions
-
10.1080/10420159808223995
-
L. Torrisi, " Radiation damage in PVT (polyvinyltoluene) induced by energetic ions.," Radiat. Eff. Defect. S. 145, 271-284 (1998). 10.1080/10420159808223995
-
(1998)
Radiat. Eff. Defect. S.
, vol.145
, pp. 271-284
-
-
Torrisi, L.1
-
45
-
-
0024082385
-
A new polyvinyltoluene-based, radiation-resistent plastic scintillator
-
10.1016/0168-9002(88)90342-7
-
C. Zorn, M. Bowen, S. Majewski, J. Walker, R. Wojcik, C. Hurlbut, and W. Moser, " A new polyvinyltoluene-based, radiation-resistent plastic scintillator.," Nucl. Instrum. Methods Phys. Res. A 271, 701-703 (1988). 10.1016/0168-9002(88)90342-7
-
(1988)
Nucl. Instrum. Methods Phys. Res. A
, vol.271
, pp. 701-703
-
-
Zorn, C.1
Bowen, M.2
Majewski, S.3
Walker, J.4
Wojcik, R.5
Hurlbut, C.6
Moser, W.7
-
46
-
-
0024143262
-
Pilot study of new radiation-resistant plastic scintillators doped with 3-hydroxyflavone
-
10.1016/0168-9002(88)90804-2
-
C. Zorn, M. Bowen, S. Majewski, J. Walker, R. Wojcik, C. Hurlbut, and W. Moser, " Pilot study of new radiation-resistant plastic scintillators doped with 3-hydroxyflavone.," Nucl. Instrum. Methods Phys. Res. A 273, 108-116 (1988). 10.1016/0168-9002(88)90804-2
-
(1988)
Nucl. Instrum. Methods Phys. Res. A
, vol.273
, pp. 108-116
-
-
Zorn, C.1
Bowen, M.2
Majewski, S.3
Walker, J.4
Wojcik, R.5
Hurlbut, C.6
Moser, W.7
-
47
-
-
38649130213
-
Radiation damage to scintillator in the DØ luminosity monitor
-
10.1109/NSSMIC.2006.356057
-
B. Casey, K. DeVaughan, Y. Enari, R. Partridge, and S. Yacoob, " Radiation damage to scintillator in the DØ luminosity monitor.," Nucl. Sci. Res. Conf. Ser. 2, 1192-1196 (2006). 10.1109/NSSMIC.2006.356057
-
(2006)
Nucl. Sci. Res. Conf. Ser.
, vol.2
, pp. 1192-1196
-
-
Casey, B.1
Devaughan, K.2
Enari, Y.3
Partridge, R.4
Yacoob, S.5
-
48
-
-
0024733319
-
Radiation damage studies in plastic scintillators with a 2.5-MeV electron beam
-
10.1016/0168-9002(89)91483-6
-
S. Majewski, M. Bowen, C. Zorn, K. Johnson, V. Hagopian, J. Thomaston, and H. Wahl, " Radiation damage studies in plastic scintillators with a 2.5-MeV electron beam.," Nucl. Instrum. Methods Phys. Res. A 281, 500-507 (1989). 10.1016/0168-9002(89)91483-6
-
(1989)
Nucl. Instrum. Methods Phys. Res. A
, vol.281
, pp. 500-507
-
-
Majewski, S.1
Bowen, M.2
Zorn, C.3
Johnson, K.4
Hagopian, V.5
Thomaston, J.6
Wahl, H.7
-
49
-
-
0027219790
-
Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry
-
10.1088/0031-9155/38/7/005
-
S. F. de Boer, A. S. Beddar, and J. A. Rawlinson, " Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry.," Phys. Med. Biol. 38, 945-958 (1993). 10.1088/0031-9155/38/7/005
-
(1993)
Phys. Med. Biol.
, vol.38
, pp. 945-958
-
-
De Boer, S.F.1
Beddar, A.S.2
Rawlinson, J.A.3
-
50
-
-
1542610651
-
Plastic scintillation dosimetry for radiation therapy: Minimizing capture of Cerenkov radiation noise
-
10.1088/0031-9155/49/5/009
-
A. S. Beddar, N. Suchowerska, and S. H. Law, " Plastic scintillation dosimetry for radiation therapy: Minimizing capture of Cerenkov radiation noise.," Phys. Med. Biol. 49, 783-790 (2004). 10.1088/0031-9155/49/5/009
-
(2004)
Phys. Med. Biol.
, vol.49
, pp. 783-790
-
-
Beddar, A.S.1
Suchowerska, N.2
Law, S.H.3
-
51
-
-
31044441579
-
Measurement accuracy and Cerenkov removal for high performance, high spatial resolution scintillation dosimetry
-
10.1118/1.2138010
-
L. Archambault, A. S. Beddar, L. Gingras, R. Roy, and L. Beaulieu, " Measurement accuracy and Cerenkov removal for high performance, high spatial resolution scintillation dosimetry.," Med. Phys. 33, 128-135 (2006). 10.1118/1.2138010
-
(2006)
Med. Phys.
, vol.33
, pp. 128-135
-
-
Archambault, L.1
Beddar, A.S.2
Gingras, L.3
Roy, R.4
Beaulieu, L.5
-
52
-
-
0016984643
-
A maximum likelihood approach to emission image reconstruction from projections
-
10.1109/TNS.1976.4328496
-
A. J. Rockmore and A. Macovski, " A maximum likelihood approach to emission image reconstruction from projections.," IEEE Trans. Nucl. Sci. 23, 1428-1432 (1976). 10.1109/TNS.1976.4328496
-
(1976)
IEEE Trans. Nucl. Sci.
, vol.23
, pp. 1428-1432
-
-
Rockmore, A.J.1
Macovski, A.2
-
53
-
-
0002629270
-
Maximum likelihood from incomplete data via the em algorithm
-
A. P. Dempster, N. M. Laird, and D. B. Rubin, " Maximum likelihood from incomplete data via the EM algorithm.," J. R. Stat. Soc. Ser. B (Methodol.) 39, 1-38 (1977).
-
(1977)
J. R. Stat. Soc. Ser. B (Methodol.)
, vol.39
, pp. 1-38
-
-
Dempster, A.P.1
Laird, N.M.2
Rubin, D.B.3
-
54
-
-
0036788460
-
Analytic and iterative reconstruction algorithms in SPECT
-
P. P. Bruyant, " Analytic and iterative reconstruction algorithms in SPECT.," J. Nucl. Med. 43, 1343-1358 (2002).
-
(2002)
J. Nucl. Med.
, vol.43
, pp. 1343-1358
-
-
Bruyant, P.P.1
-
55
-
-
33744536570
-
The ELBE radiation source project
-
W. Enghardt, F. Gabriel, P. Gippner, E. Grosse, H. Guratzsch, D. Janssen, P. Michel, U. Nething, W. Neubert, H. Prade, K. Schilling, R. Schwengner, W. Seidel, U. Steegmueller, P. vom Stein, W. Wagner, M. Wenzel, A. Wolf, and R. Wuensch, " The ELBE radiation source project.," Acta Phys. Pol. B 30, 1639-1645 (1999).
-
(1999)
Acta Phys. Pol. B
, vol.30
, pp. 1639-1645
-
-
Enghardt, W.1
Gabriel, F.2
Gippner, P.3
Grosse, E.4
Guratzsch, H.5
Janssen, D.6
Michel, P.7
Nething, U.8
Neubert, W.9
Prade, H.10
Schilling, K.11
Schwengner, R.12
Seidel, W.13
Steegmueller, U.14
Vom Stein, P.15
Wagner, W.16
Wenzel, M.17
Wolf, A.18
Wuensch, R.19
-
56
-
-
0042244438
-
Results of beam parameter measurement of the ELBE electron accelerator after commissioning
-
10.1016/S0168-9002(03)00918-5
-
J. Teichert, A. Büchner, P. Evtushenko, F. Gabriel, U. Lehnert, P. Michel, and J. Voigtländer, " Results of beam parameter measurement of the ELBE electron accelerator after commissioning.," Nucl. Instrum. Methods Phys. Res. A 507, 354-356 (2003). 10.1016/S0168-9002(03)00918-5
-
(2003)
Nucl. Instrum. Methods Phys. Res. A
, vol.507
, pp. 354-356
-
-
Teichert, J.1
Büchner, A.2
Evtushenko, P.3
Gabriel, F.4
Lehnert, U.5
Michel, P.6
Voigtländer, J.7
-
57
-
-
48149096727
-
Fast GPU-based CT reconstruction using the common unified device architecture (CUDA)
-
10.1109/NSSMIC.2007.4437102
-
H. Scherl, B. Keck, M. Kowarschik, and J. Hornegger, " Fast GPU-based CT reconstruction using the common unified device architecture (CUDA).," Nucl. Sci. Res. Conf. Ser. 6, 4464-4466 (2007). 10.1109/NSSMIC.2007.4437102
-
(2007)
Nucl. Sci. Res. Conf. Ser.
, vol.6
, pp. 4464-4466
-
-
Scherl, H.1
Keck, B.2
Kowarschik, M.3
Hornegger, J.4
-
58
-
-
82755163789
-
Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA
-
10.1118/1.3661998
-
J. Cui, G. Pratx, S. Prevrhal, and C. S. Levin, " Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA.," Med. Phys. 38, 6775-6786 (2011). 10.1118/1.3661998
-
(2011)
Med. Phys.
, vol.38
, pp. 6775-6786
-
-
Cui, J.1
Pratx, G.2
Prevrhal, S.3
Levin, C.S.4
-
59
-
-
70449387277
-
Multi GPU implementation of iterative tomographic reconstruction algorithms
-
in (IEEE, Piscataway, NJ)
-
B. Jang, D. Kaeli, S. Do, and H. Pien, " Multi GPU implementation of iterative tomographic reconstruction algorithms.," in Proceedings of 6th IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI '09), June 2009, Boston, MA (IEEE, Piscataway, NJ, 2009), pp. 185-188.
-
(2009)
Proceedings of 6th IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI '09), June 2009, Boston, MA
, pp. 185-188
-
-
Jang, B.1
Kaeli, D.2
Do, S.3
Pien, H.4
-
60
-
-
84862955331
-
Cone-beam computed tomography reconstruction accelerated with CUDA
-
D. Xiao, Y. Chen, B. Qian, L. Yang, and Y. Kang, " Cone-beam computed tomography reconstruction accelerated with CUDA.," Biomed. Eng. Informat. Conf. R. 1, 214-218 (2011).
-
(2011)
Biomed. Eng. Informat. Conf. R.
, vol.1
, pp. 214-218
-
-
Xiao, D.1
Chen, Y.2
Qian, B.3
Yang, L.4
Kang, Y.5
-
61
-
-
0026804696
-
Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
-
10.1088/0031-9155/37/10/006
-
A. S. Beddar, T. R. Mackie, and F. H. Attix, " Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations.," Phys. Med. Biol. 37, 1883-1900 (1992). 10.1088/0031-9155/37/10/006
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1883-1900
-
-
Beddar, A.S.1
Mackie, T.R.2
Attix, F.H.3
-
62
-
-
0026793771
-
Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements
-
10.1088/0031-9155/37/10/007
-
A. S. Beddar, T. R. Mackie, and F. H. Attix, " Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements.," Phys. Med. Biol. 37, 1901-1913 (1992). 10.1088/0031-9155/37/10/007
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1901-1913
-
-
Beddar, A.S.1
Mackie, T.R.2
Attix, F.H.3
-
63
-
-
84881649231
-
-
ESTAR, Stopping-power and range tables for electrons
-
ESTAR, Stopping-power and range tables for electrons " http://physics.nist.gov/PhysRefData/Star/Text/ESTAR.html ".
-
-
-
-
64
-
-
0000610466
-
The nature of the saturation effect of fluorescent scintillators
-
10.1103/PhysRev.87.904
-
C. N. Chou, " The nature of the saturation effect of fluorescent scintillators.," Phys. Rev. 87, 904-905 (1952). 10.1103/PhysRev.87.904
-
(1952)
Phys. Rev.
, vol.87
, pp. 904-905
-
-
Chou, C.N.1
-
66
-
-
84871557951
-
Quenching correction for volumetric scintillation dosimetry of proton beams
-
10.1088/0031-9155/58/2/261
-
D. Robertson, D. Mirkovic, N. Sahoo, and S. Beddar, " Quenching correction for volumetric scintillation dosimetry of proton beams.," Phys. Med. Biol. 58, 261-273 (2013). 10.1088/0031-9155/58/2/261
-
(2013)
Phys. Med. Biol.
, vol.58
, pp. 261-273
-
-
Robertson, D.1
Mirkovic, D.2
Sahoo, N.3
Beddar, S.4
-
67
-
-
0001306405
-
Coherent visible radiation of fast electrons passing through matter
-
I. Frank and I. Tamm, " Coherent visible radiation of fast electrons passing through matter.," C. R. (Dokl.) Acad. Sci. URSS 14, 109-114 (1937).
-
(1937)
C. R. (Dokl.) Acad. Sci. URSS
, vol.14
, pp. 109-114
-
-
Frank, I.1
Tamm, I.2
-
68
-
-
84857410895
-
Quantitative modeling of Cerenkov light production efficiency from medical radionuclides
-
10.1371/journal.pone.0031402
-
B. J. Beattie, D. L. J. Thorek, C. R. Schmidtlein, K. S. Pentlow, J. L. Humm, and A. H. Hielscher, " Quantitative modeling of Cerenkov light production efficiency from medical radionuclides.," PLoS ONE 7, e31402 (2012). 10.1371/journal.pone.0031402
-
(2012)
PLoS ONE
, vol.7
, pp. 31402
-
-
Beattie, B.J.1
Thorek, D.L.J.2
Schmidtlein, C.R.3
Pentlow, K.S.4
Humm, J.L.5
Hielscher, A.H.6
-
69
-
-
33846114700
-
Efficient plastic scintillators utilizing phosphorescent dopants
-
10.1063/1.2430683
-
I. H. Campbell and B. K. Crone, " Efficient plastic scintillators utilizing phosphorescent dopants.," Appl. Phys. Lett. 90, 012117 (2007). 10.1063/1.2430683
-
(2007)
Appl. Phys. Lett.
, vol.90
, pp. 012117
-
-
Campbell, I.H.1
Crone, B.K.2
-
70
-
-
5744234410
-
Development of an inorganic scintillating mixture for proton beam verification dosimetry
-
10.1088/0031-9155/49/19/013
-
S. Safai, S. Lin, and E. Pedroni, " Development of an inorganic scintillating mixture for proton beam verification dosimetry.," Phys. Med. Biol. 49, 4637 (2004). 10.1088/0031-9155/49/19/013
-
(2004)
Phys. Med. Biol.
, vol.49
, pp. 4637
-
-
Safai, S.1
Lin, S.2
Pedroni, E.3
|