메뉴 건너뛰기




Volumn 41, Issue SUPPL. 1, 2006, Pages

Plastic scintillation dosimetry and its application to radiotherapy

Author keywords

Dosimetry; Fiberoptic detectors; Radiotherapy detectors; Scintillation detectors; Scintillators

Indexed keywords

FIBER OPTICS; PHOSPHORS; PHOTOMULTIPLIERS; QUALITY ASSURANCE; RADIOTHERAPY; SCINTILLATION COUNTERS;

EID: 34248504862     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2007.01.002     Document Type: Article
Times cited : (171)

References (24)
  • 1
    • 0021062111 scopus 로고    scopus 로고
    • AAPM, 1983. A protocol for the determination of absorbed dose from high-energy photon and electron beams. Med. Phys. 10, 741-771.
  • 3
    • 0028293283 scopus 로고
    • 60Co and high-energy therapy machines
    • 60Co and high-energy therapy machines. Phys. Med. Biol. 39 (1994) 253-263
    • (1994) Phys. Med. Biol. , vol.39 , pp. 253-263
    • Beddar, A.S.1
  • 4
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
    • Beddar A.S., Mackie T.R., and Attix F.H. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations. Phys. Med. Biol. 37 (1992) 1883-1900
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1883-1900
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 6
    • 0026555508 scopus 로고
    • Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams
    • Beddar A.S., Mackie T.R., and Attix F.H. Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams. Phys. Med. Biol. 37 (1992) 925-935
    • (1992) Phys. Med. Biol. , vol.37 , pp. 925-935
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 7
    • 0035355339 scopus 로고    scopus 로고
    • A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgery
    • Beddar A.S., Kinsella T.J., Ikhlef A., and Sibata C.H. A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgery. IEEE Trans. Nucl. Sci. 48 (2001) 924-928
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 924-928
    • Beddar, A.S.1    Kinsella, T.J.2    Ikhlef, A.3    Sibata, C.H.4
  • 8
    • 0038107451 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry: optimization of light collection efficiency
    • Beddar A.S., Law S., Suchowerska N., and Mackie T.R. Plastic scintillation dosimetry: optimization of light collection efficiency. Phys. Med. Biol. 48 (2003) 1141-1152
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1141-1152
    • Beddar, A.S.1    Law, S.2    Suchowerska, N.3    Mackie, T.R.4
  • 9
    • 1542610651 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise
    • Beddar A.S., Suchowerska N., and Law S.H. Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise. Phys. Med. Biol. 49 (2004) 783-790
    • (2004) Phys. Med. Biol. , vol.49 , pp. 783-790
    • Beddar, A.S.1    Suchowerska, N.2    Law, S.H.3
  • 10
    • 0013956540 scopus 로고
    • A general theory of cavity ionization
    • Burlin T.E. A general theory of cavity ionization. Br. J. Radiol. 39 (1966) 727-734
    • (1966) Br. J. Radiol. , vol.39 , pp. 727-734
    • Burlin, T.E.1
  • 11
    • 0034109047 scopus 로고    scopus 로고
    • Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams
    • Clift M.A., Sutton R.A., and Webb D.V. Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams. Phys. Med. Biol. 45 (2000) 1165-1182
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1165-1182
    • Clift, M.A.1    Sutton, R.A.2    Webb, D.V.3
  • 12
    • 0033930606 scopus 로고    scopus 로고
    • Water equivalence of plastic organic scintillators in megavoltage radiotherapy bremsstrahlung beams
    • Clift M.A., Sutton R.A., and Webb D.V. Water equivalence of plastic organic scintillators in megavoltage radiotherapy bremsstrahlung beams. Phys. Med. Biol. 45 (2000) 1885-1895
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1885-1895
    • Clift, M.A.1    Sutton, R.A.2    Webb, D.V.3
  • 13
    • 0037149989 scopus 로고    scopus 로고
    • A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams
    • Clift M.A., Johnston P.N., and Webb D.V. A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams. Phys. Med. Biol. 47 (2002) 1421-1433
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1421-1433
    • Clift, M.A.1    Johnston, P.N.2    Webb, D.V.3
  • 15
    • 0027219790 scopus 로고
    • Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry
    • de Boer S.F., Beddar A.S., and Rawlinson J.A. Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry. Phys. Med. Biol. 38 (1993) 945-958
    • (1993) Phys. Med. Biol. , vol.38 , pp. 945-958
    • de Boer, S.F.1    Beddar, A.S.2    Rawlinson, J.A.3
  • 16
    • 0029867605 scopus 로고    scopus 로고
    • Direct reading measurement of absorbed dose with plastic scintillators-the general concept and applications to ophthalmic plaque dosimetry
    • Flühs D., Heintz M., Indenkämpen F., Wieczorek C., Kolanoski H., and Quast U. Direct reading measurement of absorbed dose with plastic scintillators-the general concept and applications to ophthalmic plaque dosimetry. Med. Phys. 23 (1996) 427-434
    • (1996) Med. Phys. , vol.23 , pp. 427-434
    • Flühs, D.1    Heintz, M.2    Indenkämpen, F.3    Wieczorek, C.4    Kolanoski, H.5    Quast, U.6
  • 18
    • 0030026160 scopus 로고    scopus 로고
    • A comparison of dosimetry techniques in stereotactic radiosurgery
    • Heydarian M., Hoban P.W., and Beddoe A.H. A comparison of dosimetry techniques in stereotactic radiosurgery. Phys. Med. Biol. 41 (1996) 93-110
    • (1996) Phys. Med. Biol. , vol.41 , pp. 93-110
    • Heydarian, M.1    Hoban, P.W.2    Beddoe, A.H.3
  • 19
    • 0020213666 scopus 로고
    • Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV
    • Hubbell J.H. Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV. Int. J. Appl. Radiat. Isot. 33 (1982) 1269-1290
    • (1982) Int. J. Appl. Radiat. Isot. , vol.33 , pp. 1269-1290
    • Hubbell, J.H.1
  • 21
    • 0342614959 scopus 로고    scopus 로고
    • Miniature scintillating detector for small field radiation therapy
    • Létourneau D., Pouliot J., and Roy R. Miniature scintillating detector for small field radiation therapy. Med. Phys. 26 (1999) 2555-2561
    • (1999) Med. Phys. , vol.26 , pp. 2555-2561
    • Létourneau, D.1    Pouliot, J.2    Roy, R.3
  • 22
    • 0033871354 scopus 로고    scopus 로고
    • SIC, an intracerebral radiosensitive probe for in vivo neuropharmacology investigations in small laboratory animals: theoretical considerations and physical characteristics
    • Pain F., Laniece P., Mastrippolito R., Charon Y., Comar D., Leviel V., Pujol J.F., and Valentin L. SIC, an intracerebral radiosensitive probe for in vivo neuropharmacology investigations in small laboratory animals: theoretical considerations and physical characteristics. IEEE Trans. Nucl. Sci. 47 (2000) 25-32
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 25-32
    • Pain, F.1    Laniece, P.2    Mastrippolito, R.3    Charon, Y.4    Comar, D.5    Leviel, V.6    Pujol, J.F.7    Valentin, L.8
  • 24
    • 0028783942 scopus 로고
    • Dosimetric characterization of radiosurgical beams with a diamond detector
    • Rustgi S.N., and Frye D.M.D. Dosimetric characterization of radiosurgical beams with a diamond detector. Med. Phys. 22 (1995) 2117-2121
    • (1995) Med. Phys. , vol.22 , pp. 2117-2121
    • Rustgi, S.N.1    Frye, D.M.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.