메뉴 건너뛰기




Volumn 38, Issue 12, 2011, Pages 6775-6786

Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA

Author keywords

acceleration; CUDA; GPU; high performance computing; line projections; list mode; OSEM; PET image reconstruction; time of flight PET

Indexed keywords

ACCELERATION; COMPUTER GRAPHICS; GRAPHICS PROCESSING UNIT; IMAGE CODING; IMAGE QUALITY; MAXIMUM PRINCIPLE; MEMORY ARCHITECTURE; NEGATIVE IONS; OPTICAL TRANSFER FUNCTION; POSITRON EMISSION TOMOGRAPHY; PROCESSING; PROGRAM PROCESSORS; SCANNING; TEXTURES;

EID: 82755163789     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3661998     Document Type: Article
Times cited : (78)

References (37)
  • 2
    • 40449116151 scopus 로고    scopus 로고
    • Benefit of time-of-flight in PET: Experimental and clinical results
    • DOI 10.2967/jnumed.107.044834
    • J. S. Karp, S. Surti, Margaret E. Daube-Witherspoon, and G. Muehllehner, Benefit of time-of-flight in PET: Experimental and clinical results., J. Nucl. Med. 49, 462-470 (2008). 10.2967/jnumed.107.044834 (Pubitemid 351355213)
    • (2008) Journal of Nuclear Medicine , vol.49 , Issue.3 , pp. 462-470
    • Karp, J.S.1    Surti, S.2    Daube-Witherspoon, M.E.3    Muehllehner, G.4
  • 3
    • 65549087684 scopus 로고    scopus 로고
    • Efficient 3D TOF PET reconstruction using view-grouped histo-images: DIRECT-direct image reconstruction for TOF
    • 10.1109/TMI.2008.2012034
    • S. Matej, S. Surti, S. Jayanthi, M. E. Daube-Witherspoon, R. M. Lewitt, and J. S. Karp, Efficient 3D TOF PET reconstruction using view-grouped histo-images: DIRECT-direct image reconstruction for TOF., IEEE Trans. Med. Imaging 28, 739-751 (2009). 10.1109/TMI.2008.2012034
    • (2009) IEEE Trans. Med. Imaging , vol.28 , pp. 739-751
    • Matej, S.1    Surti, S.2    Jayanthi, S.3    Daube-Witherspoon, M.E.4    Lewitt, R.M.5    Karp, J.S.6
  • 6
    • 50549097376 scopus 로고    scopus 로고
    • Dynamic positron emission tomography data-driven analysis using sparse bayesian learning
    • 10.1109/TMI.2008.922185
    • J. -Y. Peng, J. A. D. Aston, R. N. Gunn, C.-Y. Liou, and J. Ashburner, Dynamic positron emission tomography data-driven analysis using sparse bayesian learning., IEEE Trans. Med. Imaging 27, 1356-1369 (2008). 10.1109/TMI.2008. 922185
    • (2008) IEEE Trans. Med. Imaging , vol.27 , pp. 1356-1369
    • Peng, J.-Y.1    Aston, J.A.D.2    Gunn, R.N.3    Liou, C.-Y.4    Ashburner, J.5
  • 7
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. A. Shepp and Y. Vardi, Maximum likelihood reconstruction for emission tomography., IEEE Trans. Med. Imaging 1, 113-122 (1982). 10.1109/TMI.1982. 4307558 (Pubitemid 13557763)
    • (1982) IEEE Transactions on Medical Imaging , vol.MI-1 , Issue.2 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 8
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • 10.1109/42.363108
    • H. M. Hudson and R. S. Larkin, Accelerated image reconstruction using ordered subsets of projection data., IEEE Trans. Med. Imaging 13, 601-609 (1994). 10.1109/42.363108
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 9
    • 0031972028 scopus 로고    scopus 로고
    • Fast accurate iterative reconstruction for low-statistics positron volume imaging
    • DOI 10.1088/0031-9155/43/4/012, PII S0031915598906388
    • A. J. Reader, K. Erlandsson, M. A. Flower, and R. J. Ott, Fast accurate iterative reconstruction for low-statistics positron volume imaging., Phys. Med. Biol. 43, 835-846 (1998). 10.1088/0031-9155/43/4/012 (Pubitemid 28168413)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.4 , pp. 835-846
    • Reader, A.J.1    Erlandsson, K.2    Flower, M.A.3    Ott, R.J.4
  • 10
    • 0032034223 scopus 로고    scopus 로고
    • List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET
    • PII S0278006298049982
    • L. Parra and H. H. Barrett, List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET., IEEE Trans. Med. Imaging 17, 228-235 (1998). 10.1109/42.700734 (Pubitemid 128747675)
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.2 , pp. 228-235
    • Parra, L.1    Barrett, H.H.2
  • 11
    • 23844519353 scopus 로고    scopus 로고
    • Iterative image reconstruction using geometrically ordered subsets with list-mode data
    • M9-211, 2004 IEEE Nuclear Science Symposium Conference Record
    • L. M. Popescu, S. Matej, and R. M. Lewitt, Iterative image reconstruction using geometrically ordered subsets with list-mode data., Nuclear Science Symposium Conference Record, Vol. 6 (IEEE, Rome, Italy, 2004), pp. 3536-3540. (Pubitemid 41147710)
    • (2004) IEEE Nuclear Science Symposium Conference Record , vol.6 , pp. 3536-3540
    • Popescu, L.M.1    Matej, S.2    Lewitt, R.M.3
  • 12
    • 4644340219 scopus 로고    scopus 로고
    • Statistical list-mode image reconstruction for the high resolution research tomograph
    • DOI 10.1088/0031-9155/49/18/004, PII S0031915504827040
    • A. Rahmim, M. Lenox, A. J. Reader, C. Michel, Z. Burbar, T. J. Ruth, and V. Sossi, Statistical list-mode image reconstruction for the high resolution research tomograph., Phys. Med. Biol. 49, 4239 (2004). 10.1088/0031-9155/49/18/ 004 (Pubitemid 39302685)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.18 , pp. 4239-4258
    • Rahmim, A.1    Lenox, M.2    Reader, A.J.3    Michel, C.4    Burbar, Z.5    Ruth, T.J.6    Sossi, V.7
  • 13
    • 61449116964 scopus 로고    scopus 로고
    • Fast, accurate and shift-varying line projections for iterative reconstruction using the GPU
    • 10.1109/TMI.2008.2006518
    • G. Pratx, P. D. Olcott, G. Chinn, and C. S. Levin, Fast, accurate and shift-varying line projections for iterative reconstruction using the GPU., IEEE Trans. Med. Imaging 28, 435-445 (2009). 10.1109/TMI.2008.2006518
    • (2009) IEEE Trans. Med. Imaging , vol.28 , pp. 435-445
    • Pratx, G.1    Olcott, P.D.2    Chinn, G.3    Levin, C.S.4
  • 14
    • 34249694230 scopus 로고    scopus 로고
    • Ultra fast symmetry and SIMD-based projection-backprojection (SSP) algorithm for 3-D PET image reconstruction
    • DOI 10.1109/TMI.2007.892644
    • I. K. Hong, S. T. Chung, H. K. Kim, Y. B. Kim, Y. D. Son, and Z. H. Cho, Ultra fast symmetry and SIMD-based projection-backprojection (SSP) algorithm for 3D PET image reconstruction., IEEE Trans. Med. Imaging 26, 789-803 (2007). 10.1109/TMI.2007.892644 (Pubitemid 46842914)
    • (2007) IEEE Transactions on Medical Imaging , vol.26 , Issue.6 , pp. 789-803
    • Hong, I.K.1    Chung, S.T.2    Kim, H.K.3    Kim, Y.B.4    Son, Y.D.5    Cho, Z.H.6
  • 15
    • 27644475957 scopus 로고    scopus 로고
    • Detection of gamma ray polarization using a 3-D position-sensitive CdZnTe detector
    • DOI 10.1109/TNS.2005.852703
    • F. Xu and K. Mueller, Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware., IEEE Trans. Nucl. Sci. 52, 654-663 (2005). 10.1109/TNS.2005.852703 (Pubitemid 41561768)
    • (2005) IEEE Transactions on Nuclear Science , vol.52 , Issue.4 , pp. 1160-1164
    • Xu, D.1    He, Z.2    Zhang, F.3
  • 16
    • 34249649611 scopus 로고    scopus 로고
    • Real-time 3D computed tomographic reconstruction using commodity graphics hardware
    • DOI 10.1088/0031-9155/52/12/006, PII S0031915507372850, 006
    • F. Xu and K. Mueller, Real-time 3D computed tomographic reconstruction using commodity graphics hardware., Phys. Med. Biol. 52, 3405 (2007). 10.1088/0031-9155/52/12/006 (Pubitemid 46830633)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.12 , pp. 3405-3419
    • Xu, F.1    Mueller, K.2
  • 17
    • 78650890787 scopus 로고    scopus 로고
    • Comparing performance of many-core CPUs and GPUs for static and motion compensated reconstruction of C-arm CT data
    • 10.1118/1.3525838
    • H. G. Hofmann, B. Keck, C. Rohkohl, and J. Hornegger, Comparing performance of many-core CPUs and GPUs for static and motion compensated reconstruction of C-arm CT data., Med. Phys. 38, 468-473 (2011). 10.1118/1.3525838
    • (2011) Med. Phys. , vol.38 , pp. 468-473
    • Hofmann, H.G.1    Keck, B.2    Rohkohl, C.3    Hornegger, J.4
  • 18
    • 66749173039 scopus 로고    scopus 로고
    • High performance tomosynthesis enabled via a GPU-based iterative reconstruction framework
    • 10.1117/12.813855
    • F. Xu, A. Khamene, and O. Fluck, High performance tomosynthesis enabled via a GPU-based iterative reconstruction framework., Proc. SPIE 7258, pp. 72585A (2009). 10.1117/12.813855
    • (2009) Proc. SPIE , vol.7258
    • Xu, F.1    Khamene, A.2    Fluck, O.3
  • 19
    • 78650893054 scopus 로고    scopus 로고
    • Real-time dose computation: GPU-accelerated source modeling and superpositionconvolution
    • 10.1118/1.3483785
    • R. Jacques, J. Wong, R. Taylor, and T. McNutt, Real-time dose computation: GPU-accelerated source modeling and superpositionconvolution., Med. Phys. 38, 294-305 (2011). 10.1118/1.3483785
    • (2011) Med. Phys. , vol.38 , pp. 294-305
    • Jacques, R.1    Wong, J.2    Taylor, R.3    McNutt, T.4
  • 20
    • 79551666078 scopus 로고    scopus 로고
    • GPUMCD: A new GPU-oriented Monte Carlo dose calculation platform
    • 10.1118/1.3539725
    • S. Hissoiny, B. Ozell, H. Bouchard, and P. Despres, GPUMCD: A new GPU-oriented Monte Carlo dose calculation platform., Med. Phys. 38, 754-764 (2011). 10.1118/1.3539725
    • (2011) Med. Phys. , vol.38 , pp. 754-764
    • Hissoiny, S.1    Ozell, B.2    Bouchard, H.3    Despres, P.4
  • 21
    • 79959559455 scopus 로고    scopus 로고
    • GPU computing in medical physics: A review
    • 10.1118/1.3578605
    • G. Pratx and L. Xing, GPU computing in medical physics: A review., Med. Phys. 38, 2685-2697 (2011). 10.1118/1.3578605
    • (2011) Med. Phys. , vol.38 , pp. 2685-2697
    • Pratx, G.1    Xing, L.2
  • 24
    • 84939061977 scopus 로고
    • MLE reconstruction of a brain phantom using a Monte Carlo transition matrix and a statistical stopping rule
    • 10.1109/23.12795
    • E. Veklerov, J. Llacer, and E. J. Hoffman, MLE reconstruction of a brain phantom using a Monte Carlo transition matrix and a statistical stopping rule., IEEE Trans. Nucl. Sci. 35, 603-607 (1988). 10.1109/23.12795
    • (1988) IEEE Trans. Nucl. Sci. , vol.35 , pp. 603-607
    • Veklerov, E.1    Llacer, J.2    Hoffman, E.J.3
  • 25
    • 0034178297 scopus 로고    scopus 로고
    • List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling
    • 10.1109/42.870263
    • R. H. Huesman, G. J. Klein, W. W. Moses, J. Qi, B. W. Reutter, and P. R. G. Virador, List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling., IEEE Trans. Med. Imaging 19, 532-537 (2000). 10.1109/42.870263
    • (2000) IEEE Trans. Med. Imaging , vol.19 , pp. 532-537
    • Huesman, R.H.1    Klein, G.J.2    Moses, W.W.3    Qi, J.4    Reutter, B.W.5    Virador, P.R.G.6
  • 27
    • 0031981253 scopus 로고    scopus 로고
    • High-resolution 3D bayesian image reconstruction using the microPET small-animal scanner
    • DOI 10.1088/0031-9155/43/4/027, PII S0031915598906273
    • J. Qi, R. M. Leahy, S. R Cherry, A. Chatziioannou, and T. H. Farquhar, High-resolution 3D bayesian image reconstruction using the microPET small-animal scanner., Phys. Med. Biol. 43, 1001 (1998). 10.1088/0031-9155/43/4/027 (Pubitemid 28168428)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.4 , pp. 1001-1013
    • Qi, J.1    Leahy, R.M.2    Cherry, S.R.3    Chatziioannou, A.4    Farquhar, T.H.5
  • 29
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • DOI 10.1118/1.595715
    • R. L. Siddon, Fast calculation of the exact radiological path for a three-dimensional CT array., Med. Phys. 12, 252-255 (1985). 10.1118/1.595715 (Pubitemid 15089015)
    • (1985) Medical Physics , vol.12 , Issue.2 , pp. 252-255
    • Siddon, R.L.1
  • 30
    • 0020204372 scopus 로고
    • An improved algorithm for reprojecting rays through pixel images
    • 10.1109/TMI.1982.4307572
    • P. M. Joseph, An improved algorithm for reprojecting rays through pixel images., IEEE Trans. Med. Imaging 1, 192-196 (1982). 10.1109/TMI.1982.4307572
    • (1982) IEEE Trans. Med. Imaging , vol.1 , pp. 192-196
    • Joseph, P.M.1
  • 31
    • 79960365685 scopus 로고    scopus 로고
    • Online detector response calculations for high-resolution PET image reconstruction
    • 10.1088/0031-9155/56/13/018
    • G. Pratx and C. Levin, Online detector response calculations for high-resolution PET image reconstruction., Phys. Med. Biol. 56, 4023 (2011). 10.1088/0031-9155/56/13/018
    • (2011) Phys. Med. Biol. , vol.56 , pp. 4023
    • Pratx, G.1    Levin, C.2
  • 32
    • 0030085857 scopus 로고    scopus 로고
    • Practical considerations for 3-D image reconstruction using spherically symmetric volume elements
    • PII S0278006296012190
    • S. Matej and R. M. Lewitt, Practical considerations for 3D image reconstruction using spherically symmetric volume elements., IEEE Trans. Med. Imaging 15, 68-78 (1996). 10.1109/42.481442 (Pubitemid 126780300)
    • (1996) IEEE Transactions on Medical Imaging , vol.15 , Issue.1 , pp. 68-78
    • Matej, S.1    Lewitt, R.M.2
  • 33
    • 78149443566 scopus 로고    scopus 로고
    • Geometrical and Monte Carlo projectors in 3D PET reconstruction
    • 10.1118/1.3501884
    • P. Aguiar, M. Rafecas, J. E. Ortuo, G. Kontaxakis, A. Santos, J. Pava, and D. Ros, Geometrical and Monte Carlo projectors in 3D PET reconstruction., Med. Phys. 37, 5691-5702 (2010). 10.1118/1.3501884
    • (2010) Med. Phys. , vol.37 , pp. 5691-5702
    • Aguiar, P.1    Rafecas, M.2    Ortuo, J.E.3    Kontaxakis, G.4    Santos, A.5    Pava, J.6    Ros, D.7
  • 35
    • 34247229328 scopus 로고    scopus 로고
    • Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner
    • Y. Wang, J. Seidel, B. M. W. Tsui, J. J. Vaquero, and M. G. Pomper, Performance evaluation of the GE Healthcare eXplore VISTA dual-ring small-animal PET scanner., J. Nucl. Med. 47, 1891-1900 (2006). (Pubitemid 47545013)
    • (2006) Journal of Nuclear Medicine , vol.47 , Issue.11 , pp. 1891-1900
    • Wang, Y.1    Seidel, J.2    Tsui, B.M.W.3    Vaquero, J.J.4    Pomper, M.G.5
  • 36
    • 34247230296 scopus 로고    scopus 로고
    • Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities
    • S. Surti, A. Kuhn, M. E. Werner, A. E. Perkins, J. Kolthammer, and J. S. Karp, Performance of Philips Gemini TF PETCT scanner with special consideration for its time-of-flight imaging capabilities., J. Nucl. Med. 48, 471-480 (2007). (Pubitemid 47604933)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.3 , pp. 471-480
    • Surti, S.1    Kuhn, A.2    Werner, M.E.3    Perkins, A.E.4    Kolthammer, J.5    Karp, J.S.6
  • 37
    • 77749264192 scopus 로고    scopus 로고
    • Application and evaluation of a measured spatially variant system model for PET image reconstruction
    • 10.1109/TMI.2010.2040188
    • A. M. Alessio, C. W. Stearns, S. Tong, S. G. Ross, S. Kohlmyer, A. Ganin, and P. E. Kinahan, Application and evaluation of a measured spatially variant system model for PET image reconstruction., IEEE Trans. Med. Imaging 29, 938-949 (2010). 10.1109/TMI.2010.2040188
    • (2010) IEEE Trans. Med. Imaging , vol.29 , pp. 938-949
    • Alessio, A.M.1    Stearns, C.W.2    Tong, S.3    Ross, S.G.4    Kohlmyer, S.5    Ganin, A.6    Kinahan, P.E.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.