메뉴 건너뛰기




Volumn 49, Issue 5, 2004, Pages 783-790

Plastic scintillation dosimetry for radiation therapy: Minimizing capture of Cerenkov radiation noise

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETRY; ONCOLOGY; PLASTICITY; RADIOTHERAPY; REFRACTIVE INDEX; SCINTILLATION;

EID: 1542610651     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/49/5/009     Document Type: Article
Times cited : (40)

References (7)
  • 1
    • 0035355339 scopus 로고    scopus 로고
    • A miniature 'scintillator-fiberoptic-PMT' detector system for the dosimetry of small fields in stereotactic radiosurgery
    • Beddar A S, Kinsella T J, Ikhlef A and Sibata C H 2001 A miniature 'scintillator-fiberoptic-PMT' detector system for the dosimetry of small fields in stereotactic radiosurgery IEEE Trans. Nucl. Sci. 48 924-8
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 924-928
    • Beddar, A.S.1    Kinsella, T.J.2    Ikhlef, A.3    Sibata, C.H.4
  • 2
    • 0038107451 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry: Optimisation of light collection efficiency
    • Beddar A S, Law S H, Suchowerska N and Mackie T R 2003 Plastic scintillation dosimetry: Optimisation of light collection efficiency Phys. Med. Biol. 48 1141-52
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1141-1152
    • Beddar, A.S.1    Law, S.H.2    Suchowerska, N.3    Mackie, T.R.4
  • 3
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
    • Beddar A S, Mackie T R and Attix F H 1992a Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations Phys. Med. Biol. 37 1883-900
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1883-1900
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 4
    • 0026793771 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements
    • Beddar A S, Mackie T R and Attix F H 1992b Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements Phys. Med. Biol. 37 1901-13
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1901-1913
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 5
    • 0026555508 scopus 로고
    • Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams
    • Beddar A S, Mackie T R and Attix F H 1992c Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams Phys. Med. Biol. 37 925-35
    • (1992) Phys. Med. Biol. , vol.37 , pp. 925-935
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.