메뉴 건너뛰기




Volumn 40, Issue 8, 2013, Pages

Integrated PET/MR imaging: Automatic attenuation correction of flexible RF coils

Author keywords

attenuation correction (AC); B spline registration; hybrid imaging; radiofrequency (RF) surface coil; simultaneous whole body PET MR

Indexed keywords

ERRORS; INTERPOLATION; MAGNETIC RESONANCE IMAGING; PHANTOMS;

EID: 84881635416     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4812685     Document Type: Article
Times cited : (64)

References (25)
  • 1
    • 80053611395 scopus 로고    scopus 로고
    • An outlook on future design of hybrid PET/MRI systems
    • 10.1118/1.3633909
    • H. Zaidi and A. D. Guerra, " An outlook on future design of hybrid PET/MRI systems.," Med. Phys. 38 (10), 5667-5689 (2011). 10.1118/1.3633909
    • (2011) Med. Phys. , vol.38 , Issue.10 , pp. 5667-5689
    • Zaidi, H.1    Guerra, A.D.2
  • 3
    • 83755161889 scopus 로고    scopus 로고
    • Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner
    • 10.2967/jnumed.111.092726
    • G. Delso, S. Fürst, B. Jakoby, R. Ladebeck, C. Ganter, S. G. Nekolla, M. Schwaiger, and S. I. Ziegler, " Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner.," J. Nucl. Med. 52 (12), 1914-1922 (2011). 10.2967/jnumed.111.092726
    • (2011) J. Nucl. Med. , vol.52 , Issue.12 , pp. 1914-1922
    • Delso, G.1    Fürst, S.2    Jakoby, B.3    Ladebeck, R.4    Ganter, C.5    Nekolla, S.G.6    Schwaiger, M.7    Ziegler, S.I.8
  • 5
    • 84875757237 scopus 로고    scopus 로고
    • Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT
    • 10.1007/s00259-012-2249-y
    • M. Wiesmüller, H. H. Quick, B. Navalpakkam, M. M. Lell, M. Uder, P. Ritt, D. Schmidt, M. Beck, T. Kuwert, and C. C. von Gall, " Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT.," Eur. J. Nucl. Med. Mol. Imaging 40 (1), 12-21 (2013). 10.1007/s00259-012-2249-y
    • (2013) Eur. J. Nucl. Med. Mol. Imaging , vol.40 , Issue.1 , pp. 12-21
    • Wiesmüller, M.1    Quick, H.H.2    Navalpakkam, B.3    Lell, M.M.4    Uder, M.5    Ritt, P.6    Schmidt, D.7    Beck, M.8    Kuwert, T.9    Von Gall, C.C.10
  • 6
    • 0037811001 scopus 로고    scopus 로고
    • X-ray-based attenuation correction for oositron emission tomography/computed tomography scanners
    • 10.1053/snuc.2003.127307
    • P. E. Kinahan, B. H. Hasegawa, and T. Beyer, " X-ray-based attenuation correction for oositron emission tomography/computed tomography scanners.," Semin. Nucl. Med. 33 (3), 166-179 (2003). 10.1053/snuc.2003. 127307
    • (2003) Semin. Nucl. Med. , vol.33 , Issue.3 , pp. 166-179
    • Kinahan, P.E.1    Hasegawa, B.H.2    Beyer, T.3
  • 7
    • 63849338624 scopus 로고    scopus 로고
    • Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: Evaluation with PET/CT Data
    • 10.2967/jnumed.108.054726
    • A. Martinez-Möller, M. Souvatzoglou, G. Delso, R. A. Bundschuh, C. Chefd'hotel, S. I. Ziegler, N. Navab, M. Schwaiger, and S. G. Nekolla, " Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: Evaluation with PET/CT Data.," J. Nucl. Med. 50 (4), 520-526 (2009). 10.2967/jnumed.108.054726
    • (2009) J. Nucl. Med. , vol.50 , Issue.4 , pp. 520-526
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Delso, G.3    Bundschuh, R.A.4    Chefd'Hotel, C.5    Ziegler, S.I.6    Navab, N.7    Schwaiger, M.8    Nekolla, S.G.9
  • 9
    • 78049448620 scopus 로고    scopus 로고
    • Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
    • 10.1088/0031-9155/55/15/011
    • G. Delso, A. Martinez-Möller, R. A. Bundschuh, R. Ladebeck, Y. Candidus, D. Faul, and S. I. Ziegler, " Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner.," Phys. Med. Biol. 55, 4361-4374 (2010). 10.1088/0031-9155/55/15/011
    • (2010) Phys. Med. Biol. , vol.55 , pp. 4361-4374
    • Delso, G.1    Martinez-Möller, A.2    Bundschuh, R.A.3    Ladebeck, R.4    Candidus, Y.5    Faul, D.6    Ziegler, S.I.7
  • 10
    • 79958775484 scopus 로고    scopus 로고
    • Effects of MR surface coils on PET quantification
    • 10.1118/1.3583697
    • L. R. MacDonald, S. Kohlmyer, C. Liu, T. K. Lewellen, and P. E. Kinahan, " Effects of MR surface coils on PET quantification.," Med. Phys. 38 (6), 2948-2956 (2011). 10.1118/1.3583697
    • (2011) Med. Phys. , vol.38 , Issue.6 , pp. 2948-2956
    • Macdonald, L.R.1    Kohlmyer, S.2    Liu, C.3    Lewellen, T.K.4    Kinahan, P.E.5
  • 11
    • 79959543762 scopus 로고    scopus 로고
    • The effect of MR surface coils on PET quantification in whole-body PET/MR: Results from a pseudo-PET/MR phantom study
    • 10.1118/1.3582699
    • L. Tellmann, H. H. Quick, A. Bockisch, H. Herzog, and T. Beyer, " The effect of MR surface coils on PET quantification in whole-body PET/MR: Results from a pseudo-PET/MR phantom study.," Med. Phys. 38 (5), 2795-2805 (2011). 10.1118/1.3582699
    • (2011) Med. Phys. , vol.38 , Issue.5 , pp. 2795-2805
    • Tellmann, L.1    Quick, H.H.2    Bockisch, A.3    Herzog, H.4    Beyer, T.5
  • 12
    • 84864220423 scopus 로고    scopus 로고
    • Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils
    • 10.1118/1.4729716
    • D. H. Paulus, H. Braun, B. Aklan, and H. H. Quick, " Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils.," Med. Phys. 39 (7), 4306-4315 (2012). 10.1118/1.4729716
    • (2012) Med. Phys. , vol.39 , Issue.7 , pp. 4306-4315
    • Paulus, D.H.1    Braun, H.2    Aklan, B.3    Quick, H.H.4
  • 14
    • 33847606950 scopus 로고    scopus 로고
    • Lung metastases detection in CT images using 3D template matching
    • 10.1118/1.2436970
    • P. Wang, A. DeNunzio, P. Okunieff, and W. G. O'Dell, " Lung metastases detection in CT images using 3D template matching.," Med. Phys. 34 (3), 915-922 (2007). 10.1118/1.2436970
    • (2007) Med. Phys. , vol.34 , Issue.3 , pp. 915-922
    • Wang, P.1    Denunzio, A.2    Okunieff, P.3    O'Dell, W.G.4
  • 15
    • 79955666988 scopus 로고    scopus 로고
    • Repeated surface registration for on-line use
    • 10.1007/s00170-010-2950-6
    • P. Bergström, O. Edlund, and I. Söderkvist, " Repeated surface registration for on-line use.," Int. J Adv. Manuf. Technol. 54, 677-689 (2011). 10.1007/s00170-010-2950-6
    • (2011) Int. J Adv. Manuf. Technol. , vol.54 , pp. 677-689
    • Bergström, P.1    Edlund, O.2    Söderkvist, I.3
  • 16
    • 0033169211 scopus 로고    scopus 로고
    • Nonrigid registration using free-form deformations: Application to breast MR images
    • 10.1109/42.796284
    • D. Rueckert, L. I. Sonoda, C. Hayes, D. L. G. Hill, M. O. Leach, D. J. Hawkes, " Nonrigid registration using free-form deformations: Application to breast MR images.," IEEE Trans. Med. Imaging 18 (8), 712-721 (1999). 10.1109/42.796284
    • (1999) IEEE Trans. Med. Imaging , vol.18 , Issue.8 , pp. 712-721
    • Rueckert, D.1    Sonoda, L.I.2    Hayes, C.3    Hill, D.L.G.4    Leach, M.O.5    Hawkes, D.J.6
  • 18
    • 84881440615 scopus 로고    scopus 로고
    • Systematic evaluation of phantom fluids for simultaneous PET/MR hybrid imaging
    • [Epub ahead of print].
    • S. Ziegler, H. Braun, P. Ritt, C. Hocke, T. Kuwert, and H. H. Quick, " Systematic evaluation of phantom fluids for simultaneous PET/MR hybrid imaging.," J. Nucl. Med. (2013) [Epub ahead of print].
    • (2013) J. Nucl. Med.
    • Ziegler, S.1    Braun, H.2    Ritt, P.3    Hocke, C.4    Kuwert, T.5    Quick, H.H.6
  • 19
    • 33645510085 scopus 로고    scopus 로고
    • Method for transforming CT images for attenuation correction in PET/CT imaging
    • 10.1118/1.2174132
    • J. P. J. Carney, D. W. Townsend, V. Rappoport, and B. Bendriem, " Method for transforming CT images for attenuation correction in PET/CT imaging.," Med. Phys. 33 (4), 976-983 (2006). 10.1118/1.2174132
    • (2006) Med. Phys. , vol.33 , Issue.4 , pp. 976-983
    • Carney, J.P.J.1    Townsend, D.W.2    Rappoport, V.3    Bendriem, B.4
  • 20
    • 84861632676 scopus 로고    scopus 로고
    • Hybrid PET/MRI imaging with continuous table motion
    • 10.1118/1.4704726
    • H. Braun, S. Ziegler, D. H. Paulus, and H. H. Quick, " Hybrid PET/MRI imaging with continuous table motion.," Med. Phys. 39 (5), 2735-2745 (2012). 10.1118/1.4704726
    • (2012) Med. Phys. , vol.39 , Issue.5 , pp. 2735-2745
    • Braun, H.1    Ziegler, S.2    Paulus, D.H.3    Quick, H.H.4
  • 21
    • 0032173355 scopus 로고    scopus 로고
    • Predicting error in rigid-body point-based registration
    • 10.1109/42.736021
    • J. M. Fitzpatrick, J. B. West, and C. R. Maurer, " Predicting error in rigid-body point-based registration.," IEEE Trans. Med. Imaging. 17 (5), 694-702 (1998). 10.1109/42.736021
    • (1998) IEEE Trans. Med. Imaging. , vol.17 , Issue.5 , pp. 694-702
    • Fitzpatrick, J.M.1    West, J.B.2    Maurer, C.R.3
  • 23
    • 84881631740 scopus 로고    scopus 로고
    • Hardware attenuation correction in PET/MR hybrid Imaging: Evaluation of μ-maps for local RF coils
    • D. H. Paulus, H. Braun, and H. H. Quick, " Hardware attenuation correction in PET/MR hybrid Imaging: Evaluation of μ-maps for local RF coils.," Proc. Intl. Soc. Mag. Reson. Med. 21, 2812 (2013).
    • (2013) Proc. Intl. Soc. Mag. Reson. Med. , vol.21 , pp. 2812
    • Paulus, D.H.1    Braun, H.2    Quick, H.H.3
  • 24
    • 84881644081 scopus 로고    scopus 로고
    • See supplementary material at http://dx.doi.org/10.1118/1.4812685 E-MPHYA6-40-030308 for a detailed discussion of the registration error caused by non-rigid deformation of solid structures of the RF coils.
  • 25
    • 84881644081 scopus 로고    scopus 로고
    • See supplementary material at http://dx.doi.org/10.1118/1.4812685 E-MPHYA6-40-030308 for a detailed description of the discrimination between multiple RF coils by the algorithm.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.