메뉴 건너뛰기




Volumn 43, Issue 10, 2002, Pages 1398-1409

PET performance measurements using the NEMA NU 2-2001 standard

Author keywords

Performance measurements; PET

Indexed keywords

ARTICLE; DIAGNOSTIC ACCURACY; IMAGE QUALITY; PHANTOM; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; SCINTILLATION CAMERA; STANDARD;

EID: 0036788462     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (195)

References (16)
  • 1
    • 0026323156 scopus 로고
    • Performance standards in positron emission tomography
    • Karp JS, Daube-Witherspoon ME, Hoffman EJ, et al. Performance standards in positron emission tomography. J Nucl Med. 1991;32:2342-2350.
    • (1991) J Nucl Med , vol.32 , pp. 2342-2350
    • Karp, J.S.1    Daube-Witherspoon, M.E.2    Hoffman, E.J.3
  • 5
    • 0023640412 scopus 로고
    • Treatment of axial data in three-dimensional positron emission tomography
    • Daube-Witherspoon ME, Muehllehner G. Treatment of axial data in three-dimensional positron emission tomography. J Nucl Med. 1987;28:1717-1724.
    • (1987) J Nucl Med , vol.28 , pp. 1717-1724
    • Daube-Witherspoon, M.E.1    Muehllehner, G.2
  • 6
    • 0025800480 scopus 로고
    • A method for measuring the absolute sensitivity of positron emission tomographic scanners
    • Bailey DL, Jones T, Spinks TJ. A method for measuring the absolute sensitivity of positron emission tomographic scanners. Ear J Nucl Med. 1991;18:374-379.
    • (1991) Ear J Nucl Med , vol.18 , pp. 374-379
    • Bailey, D.L.1    Jones, T.2    Spinks, T.J.3
  • 7
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating count-rates to image signal-to-noise ratios using noise equivalent counts
    • Strother SC. Casey ME. Hoffman EJ, Measuring PET scanner sensitivity: relating count-rates to image signal-to-noise ratios using noise equivalent counts. IEEE Trans Nucl Sci. 1990;37:783-788.
    • (1990) IEEE Trans Nucl Sci , vol.37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 8
    • 0026352843 scopus 로고
    • Methodologies for performance evaluation of positron emission tomographs
    • Guzzardi R, Bellina CR, Knoop B, et al. Methodologies for performance evaluation of positron emission tomographs. J Nucl Biol Med. 1991;35:141-157.
    • (1991) J Nucl Biol Med , vol.35 , pp. 141-157
    • Guzzardi, R.1    Bellina, C.R.2    Knoop, B.3
  • 9
    • 0035659148 scopus 로고    scopus 로고
    • Performance of a whole-body PET scanner using curve-plate Nal(TI) detectors
    • Adam L-E, Karp JS. Daube-Witherspoon ME, Smith RJ. Performance of a whole-body PET scanner using curve-plate Nal(TI) detectors. J Nucl Med. 2001;42:1821-1830.
    • (2001) J Nucl Med , vol.42 , pp. 1821-1830
    • Adam, L.-E.1    Karp, J.S.2    Daube-Witherspoon, M.E.3    Smith, R.J.4
  • 10
    • 0027398350 scopus 로고
    • The convergence of object-dependent resolution in maximum likelihood based tomographic reconstruction
    • Liow JS, Strother SC. The convergence of object-dependent resolution in maximum likelihood based tomographic reconstruction. Phys Med Biol. 1993;38:55-70.
    • (1993) Phys Med Biol , vol.38 , pp. 55-70
    • Liow, J.S.1    Strother, S.C.2
  • 11
    • 0035428654 scopus 로고    scopus 로고
    • NEMA NU 2-2000 performance measurements on an ADAC MCD camera
    • Sossi V, Pointon B, Boudoux C. et al. NEMA NU 2-2000 performance measurements on an ADAC MCD camera. IEEE Trans Nucl Sci. 2001;48:1518-1523.
    • (2001) IEEE Trans Nucl Sci , vol.48 , pp. 1518-1523
    • Sossi, V.1    Pointon, B.2    Boudoux, C.3
  • 12
    • 0000012493 scopus 로고
    • On some nonlinear iterative relaxation methods in remote sensing
    • De Pierro AR. On some nonlinear iterative relaxation methods in remote sensing. Matematica Aplicada Computacional. 1989;8:153-166.
    • (1989) Matematica Aplicada Computacional , vol.8 , pp. 153-166
    • De Pierro, A.R.1
  • 13
    • 0030270511 scopus 로고    scopus 로고
    • A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography
    • Browne JA, De Pierro AR. A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography. IEEE Trans Med Imaging. 1996;15:687-699.
    • (1996) IEEE Trans Med Imaging , vol.15 , pp. 687-699
    • Browne, J.A.1    De Pierro, A.R.2
  • 15
    • 0001171133 scopus 로고    scopus 로고
    • Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard
    • Adam L-E, Zaers J. Ostertag H, Trojan H, Bellemann ME, Brix G. Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard, IEEE Trans Nucl Sci. 1997;44:1172-1179.
    • (1997) IEEE Trans Nucl Sci , vol.44 , pp. 1172-1179
    • Adam, L.-E.1    Zaers, J.2    Ostertag, H.3    Trojan, H.4    Bellemann, M.E.5    Brix, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.