메뉴 건너뛰기




Volumn 54, Issue 8, 2013, Pages 1464-1471

Systematic evaluation of phantom fluids for simultaneous PET/MR hybrid imaging

Author keywords

Inhomogeneous radiofrequency excitation; Integrated PET MR hybrid imaging; NEMA standard phantom; PET MR phantom measurements; Radiofrequency artifact

Indexed keywords

CRYPTAND 2.2.2; ETHYLENE GLYCOL; FLUORINE 18; FLUORODEOXYGLUCOSE F 18; OIL; TRIETHYLENE GLYCOL; WATER;

EID: 84881440615     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.112.116376     Document Type: Article
Times cited : (45)

References (26)
  • 1
    • 79955416013 scopus 로고    scopus 로고
    • Design and performance evaluation of a whole-body Ingenuity TF PET-MR imaging system
    • Zaidi H, Ojha N, Morich M, et al. Design and performance evaluation of a whole-body Ingenuity TF PET-MR imaging system. Phys Med Biol. 2011;56:3091-3106.
    • (2011) Phys Med Biol , vol.56 , pp. 3091-3106
    • Zaidi, H.1    Ojha, N.2    Morich, M.3
  • 2
    • 83755161889 scopus 로고    scopus 로고
    • Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner
    • Delso G, Fürst S, Jakoby B, et al. Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med. 2011;52: 1914-1922.
    • (2011) J Nucl Med , vol.52 , pp. 1914-1922
    • Delso, G.1    Fürst, S.2    Jakoby, B.3
  • 4
    • 12744262814 scopus 로고    scopus 로고
    • Central brightening due to constructive interference with, without, and despite dielectric resonance
    • Collins CM, Liu W, Schreiber W, Yang QX, Smith MB. Central brightening due to constructive interference with, without, and despite dielectric resonance. J Magn Reson Imaging. 2005;21:192-196.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 192-196
    • Collins, C.M.1    Liu, W.2    Schreiber, W.3    Yang, Q.X.4    Smith, M.B.5
  • 5
    • 34447341182 scopus 로고    scopus 로고
    • High-field-strength magnetic resonance: Potential and limits
    • Ladd ME. High-field-strength magnetic resonance: potential and limits. Top Magn Reson Imaging. 2007;18:139-152.
    • (2007) Top Magn Reson Imaging , vol.18 , pp. 139-152
    • Ladd, M.E.1
  • 6
    • 0032129166 scopus 로고    scopus 로고
    • Standing-wave and RF penetration artifacts caused by elliptic geometry: An electrodynamic analysis of MR imaging
    • Sled JG, Pike GB. Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MR imaging. IEEE Trans Med Imaging. 1998;17:653-662.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 653-662
    • Sled, J.G.1    Pike, G.B.2
  • 7
    • 0035006349 scopus 로고    scopus 로고
    • Dielectric resonances and B1 field inhomogeneity in UHFMRI: Computational analysis and experimental findings
    • Ibrahim TS, Lee R, Abduljalil AM, Baertlein BA, Robitaille P-ML. Dielectric resonances and B1 field inhomogeneity in UHFMRI: computational analysis and experimental findings. Magn Reson Imaging. 2001;19:219-226.
    • (2001) Magn Reson Imaging , vol.19 , pp. 219-226
    • Ibrahim, T.S.1    Lee, R.2    Abduljalil, A.M.3    Baertlein, B.A.4    Robitaille, P.-M.L.5
  • 8
    • 84886949767 scopus 로고    scopus 로고
    • B11 and B1-field pattern dependence on the electrical properties of the sample and the static magnetic field strength [abstract]
    • Vaidya MV, Sodickson DK, Brown R, Wiggins GC, Lattanzi R. B11 and B1-field pattern dependence on the electrical properties of the sample and the static magnetic field strength [abstract]. Proc Intl Soc Mag Reson Med 20. 2012:2796.
    • (2012) Proc Intl Soc Mag Reson Med , vol.20 , pp. 2796
    • Vaidya, M.V.1    Sodickson, D.K.2    Brown, R.3    Wiggins, G.C.4    Lattanzi, R.5
  • 9
    • 33745503397 scopus 로고    scopus 로고
    • Abdominal MR imaging at 3. 0 T: The basics revisited
    • Merkle EM, Dale BM. Abdominal MR imaging at 3.0 T: the basics revisited. AJR. 2006;186:1524-1532.
    • (2006) AJR , vol.186 , pp. 1524-1532
    • Merkle, E.M.1    Dale, B.M.2
  • 10
    • 4243556316 scopus 로고
    • Standing waves in uniform water phantoms
    • Tofts PS. Standing waves in uniform water phantoms. J Magn Reson B. 1994;104:143-147.
    • (1994) J Magn Reson B , vol.104 , pp. 143-147
    • Tofts, P.S.1
  • 11
    • 0028339167 scopus 로고
    • Sources of intensity nonuniformity in spin echo images at 1. 5 T
    • Simmons A, Tofts PS, Barker GJ, Arridge SR. Sources of intensity nonuniformity in spin echo images at 1.5 T. Magn Reson Med. 1994;32:121-128.
    • (1994) Magn Reson Med , vol.32 , pp. 121-128
    • Simmons, A.1    Tofts, P.S.2    Barker, G.J.3    Arridge, S.R.4
  • 12
    • 84962182985 scopus 로고    scopus 로고
    • Phantom fluids for high field MR imaging [abstract]
    • Skloss T. Phantom fluids for high field MR imaging [abstract]. Proc Intl Soc Magn Reson Med 11. 2004:1635.
    • (2004) Proc Intl Soc Magn Reson Med , vol.11 , pp. 1635
    • Skloss, T.1
  • 13
    • 33745111311 scopus 로고    scopus 로고
    • Performance test of an LSO-APD detector in a 7-T MR imaging scanner for simultaneous PET/MR imaging
    • Pichler BJ, Judenhofer MS, Catana C, et al. Performance test of an LSO-APD detector in a 7-T MR imaging scanner for simultaneous PET/MR imaging. J Nucl Med. 2006;47:639-647.
    • (2006) J Nucl Med , vol.47 , pp. 639-647
    • Pichler, B.J.1    Judenhofer, M.S.2    Catana, C.3
  • 15
    • 0003710941 scopus 로고    scopus 로고
    • National Electrical Manufacturers Association. NEMA Standards Publication NU 2-2007. Rosslyn, VA: NEMA
    • National Electrical Manufacturers Association. NEMA Standards Publication NU 2-2007. Performance Measurements of Positron Emission Tomographs. Rosslyn, VA: NEMA; 2007:26-33.
    • (2007) Performance Measurements of Positron Emission Tomographs , pp. 26-33
  • 16
    • 84881437259 scopus 로고
    • Plastics Design Library. Morris, NY: Plastics Design Library
    • Plastics Design Library. Chemical Resistance, Volume I: Thermoplastics. Morris, NY: Plastics Design Library; 1994:81.
    • (1994) Chemical Resistance, Volume I: Thermoplastics , pp. 81
  • 19
    • 57049135904 scopus 로고    scopus 로고
    • Review of 18F-FDG synthesis and quality control
    • Yu S. Review of 18F-FDG synthesis and quality control. Biomed Imaging Interv J. 2006;2:e57.
    • (2006) Biomed Imaging Interv J , vol.2
    • Yu, S.1
  • 20
    • 0022885139 scopus 로고
    • Efficient stereospecific synthesis of nocarrier-added 2-(18F)-fluoro-2-deoxy-D-glucose using aminopolyether supported nucleophilic substitution
    • Hamacher K, Coenen HH, Stöcklin G. Efficient stereospecific synthesis of nocarrier-added 2-(18F)-fluoro-2-deoxy-D-glucose using aminopolyether supported nucleophilic substitution. J Nucl Med. 1986;27:235-238.
    • (1986) J Nucl Med , vol.27 , pp. 235-238
    • Hamacher, K.1    Coenen, H.H.2    Stöcklin, G.3
  • 22
    • 2542490139 scopus 로고    scopus 로고
    • PET tracers and radiochemistry
    • Schlyer DJ. PET tracers and radiochemistry. Ann Acad Med Singapore. 2004; 33:146-154.
    • (2004) Ann Acad Med Singapore , vol.33 , pp. 146-154
    • Schlyer, D.J.1
  • 24
    • 63849338624 scopus 로고    scopus 로고
    • Tissue classification as a potential approach for attenuation correction in whole-body PET/MR imaging
    • Martinez-Möller A, Souvatzoglou M, Delso G, et al. Tissue classification as a potential approach for attenuation correction in whole-body PET/MR imaging. J Nucl Med. 2009;50:520-526.
    • (2009) J Nucl Med , vol.50 , pp. 520-526
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Delso, G.3
  • 25
    • 1342330052 scopus 로고    scopus 로고
    • MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3. 0 T: Preliminary results
    • de Bazelaire CMJ, Duhamel GD, Rofsky NM, Alsop DC. MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology. 2004;230:652-659.
    • (2004) Radiology , vol.230 , pp. 652-659
    • De Bazelaire, C.M.J.1    Duhamel, G.D.2    Rofsky, N.M.3    Alsop, D.C.4
  • 26
    • 84864220423 scopus 로고    scopus 로고
    • Simultaneous PET/MR imaging: MRbased attenuation correction of local radiofrequency surface coils
    • Paulus DH, Braun H, Aklan B, Quick HH. Simultaneous PET/MR imaging: MRbased attenuation correction of local radiofrequency surface coils. Med Phys. 2012;39:4306-4315.
    • (2012) Med Phys , vol.39 , pp. 4306-4315
    • Paulus, D.H.1    Braun, H.2    Aklan, B.3    Quick, H.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.