메뉴 건너뛰기




Volumn 755, Issue 2, 2013, Pages 120-125

In vitro micronucleus assay for the analysis of total particulate matter in cigarette smoke: Comparison of flow cytometry and laser scanning cytometry with microscopy

Author keywords

Cigarette smoke; Flow cytometry; Laser scanning cytometry; Micronucleus; Total particulate matter

Indexed keywords

CIGARETTE SMOKE; FLUORESCEIN ISOTHIOCYANATE;

EID: 84881025295     PISSN: 13835718     EISSN: 18793592     Source Type: Journal    
DOI: 10.1016/j.mrgentox.2013.05.017     Document Type: Article
Times cited : (4)

References (25)
  • 1
    • 0016437314 scopus 로고
    • The micronucleus test
    • Schmid W. The micronucleus test. Mutat. Res. 1975, 31:9.
    • (1975) Mutat. Res. , vol.31 , pp. 9
    • Schmid, W.1
  • 2
    • 0015106801 scopus 로고
    • Trenimon-induced chromosomal damage in bone-marrow cells of six mammalian species, evaluated by the micronucleus test
    • Matter B., Schmid W. Trenimon-induced chromosomal damage in bone-marrow cells of six mammalian species, evaluated by the micronucleus test. Mutat. Res.-Fund Mol. M. 1971, 12:417-425.
    • (1971) Mutat. Res.-Fund Mol. M. , vol.12 , pp. 417-425
    • Matter, B.1    Schmid, W.2
  • 3
    • 84881024645 scopus 로고    scopus 로고
    • OECD guideline for the testing of chemicals.
    • N. Guideline, OECD guideline for the testing of chemicals.
    • Guideline, N.1
  • 4
    • 78650660704 scopus 로고    scopus 로고
    • Application and adaptation of the in vitro micronucleus assay for the assessment of nutritional requirements of cells for DNA damage prevention
    • Bull C.F., Beetstra-Hill S., Benassi-Evans B.J., Crott J.W., Kimura M., Teo T., Wu J., Fenech M.F. Application and adaptation of the in vitro micronucleus assay for the assessment of nutritional requirements of cells for DNA damage prevention. Mutagenesis 2011, 26:193-197.
    • (2011) Mutagenesis , vol.26 , pp. 193-197
    • Bull, C.F.1    Beetstra-Hill, S.2    Benassi-Evans, B.J.3    Crott, J.W.4    Kimura, M.5    Teo, T.6    Wu, J.7    Fenech, M.F.8
  • 5
    • 0034693730 scopus 로고    scopus 로고
    • The in vitro micronucleus technique
    • Fenech M. The in vitro micronucleus technique. Mutat. Res.-Fund Mol. M. 2000, 455:81-95.
    • (2000) Mutat. Res.-Fund Mol. M. , vol.455 , pp. 81-95
    • Fenech, M.1
  • 7
    • 0025123909 scopus 로고
    • The present state of the automated micronucleus test for lymphocytes
    • Tates A., Van Welie M., Ploem J. The present state of the automated micronucleus test for lymphocytes. Int. J. Radiat. Biol. 1990, 58:813-825.
    • (1990) Int. J. Radiat. Biol. , vol.58 , pp. 813-825
    • Tates, A.1    Van Welie, M.2    Ploem, J.3
  • 8
    • 0030880339 scopus 로고    scopus 로고
    • Semi-automated micronucleus scoring in cytokinesis-blocked lymphocytes after irradiation
    • Thierens H., Vral A., Scheerder F., Ridder L., Tates A. Semi-automated micronucleus scoring in cytokinesis-blocked lymphocytes after irradiation. Int. J. Radiat. Biol. 1997, 72:319-324.
    • (1997) Int. J. Radiat. Biol. , vol.72 , pp. 319-324
    • Thierens, H.1    Vral, A.2    Scheerder, F.3    Ridder, L.4    Tates, A.5
  • 9
    • 0033978261 scopus 로고    scopus 로고
    • Malaria-infected erythrocytes serve as biological standards to ensure reliable and consistent scoring of micronucleated erythrocytes by flow cytometry
    • Dertinger S.D., Torous D.K., Hall N.E., Tometsko C.R., Gasiewicz T.A. Malaria-infected erythrocytes serve as biological standards to ensure reliable and consistent scoring of micronucleated erythrocytes by flow cytometry. Mutat. Res.-Fund Mol. M. 2000, 464:195-200.
    • (2000) Mutat. Res.-Fund Mol. M. , vol.464 , pp. 195-200
    • Dertinger, S.D.1    Torous, D.K.2    Hall, N.E.3    Tometsko, C.R.4    Gasiewicz, T.A.5
  • 10
    • 0042591389 scopus 로고    scopus 로고
    • Comparative scoring of micronucleated reticulocytes in rat peripheral blood by flow cytometry and microscopy
    • Torous D.K., Hall N.E., Murante F.G., Gleason S.E., Tometsko C.R., Dertinger S.D. Comparative scoring of micronucleated reticulocytes in rat peripheral blood by flow cytometry and microscopy. Toxicol. Sci. 2003, 74:309-314.
    • (2003) Toxicol. Sci. , vol.74 , pp. 309-314
    • Torous, D.K.1    Hall, N.E.2    Murante, F.G.3    Gleason, S.E.4    Tometsko, C.R.5    Dertinger, S.D.6
  • 11
    • 34248525923 scopus 로고    scopus 로고
    • In vitro micronucleus assay scored by flow cytometry provides a comprehensive evaluation of cytogenetic damage and cytotoxicity
    • Bryce S.M., Bemis J.C., Avlasevich S.L., Dertinger S.D. In vitro micronucleus assay scored by flow cytometry provides a comprehensive evaluation of cytogenetic damage and cytotoxicity. Mutat. Res.-Gen. Tox. En. 2007, 630:78-91.
    • (2007) Mutat. Res.-Gen. Tox. En. , vol.630 , pp. 78-91
    • Bryce, S.M.1    Bemis, J.C.2    Avlasevich, S.L.3    Dertinger, S.D.4
  • 12
    • 79961034182 scopus 로고    scopus 로고
    • Fast image analysis for the micronucleus assay in a fully automated high-throughput biodosimetry system
    • (Submitted)
    • Lyulko O., Garty G., Randers-Pehrson G., Turner H., Brenner D. Fast image analysis for the micronucleus assay in a fully automated high-throughput biodosimetry system. Radiat. Res. 2011, (Submitted).
    • (2011) Radiat. Res.
    • Lyulko, O.1    Garty, G.2    Randers-Pehrson, G.3    Turner, H.4    Brenner, D.5
  • 13
    • 0035370138 scopus 로고    scopus 로고
    • Automation of mouse micronucleus genotoxicity assay by laser scanning cytometry
    • Styles J., Clark H., Festing M., Rew D. Automation of mouse micronucleus genotoxicity assay by laser scanning cytometry. Cytometry 2001, 44:153-155.
    • (2001) Cytometry , vol.44 , pp. 153-155
    • Styles, J.1    Clark, H.2    Festing, M.3    Rew, D.4
  • 16
    • 73449115354 scopus 로고    scopus 로고
    • Evaluation of in vitro assays for assessing the toxicity of cigarette smoke and smokeless tobacco
    • Johnson M.D., Schilz J., Djordjevic M.V., Rice J.R., Shields P.G. Evaluation of in vitro assays for assessing the toxicity of cigarette smoke and smokeless tobacco. Cancer Epidem. Biomar. 2009, 18:3263-3304.
    • (2009) Cancer Epidem. Biomar. , vol.18 , pp. 3263-3304
    • Johnson, M.D.1    Schilz, J.2    Djordjevic, M.V.3    Rice, J.R.4    Shields, P.G.5
  • 17
    • 84881028916 scopus 로고    scopus 로고
    • Evaluation of the potential effects of flavor ingredients added to cigarettes. Part 1. Cigarette design and testing. 10 Apr 1999. Bates number 2505330385/2505330415
    • E. Carmines, Evaluation of the potential effects of flavor ingredients added to cigarettes. Part 1. Cigarette design and testing. 10 Apr 1999. Bates number 2505330385/2505330415, 2011.
    • (2011)
    • Carmines, E.1
  • 22
    • 79957925511 scopus 로고    scopus 로고
    • A flow cytometry based in vitro micronucleus assay in TK6 cells - validation using early stage pharmaceutical development compounds
    • Lukamowicz M., Woodward K., Kirsch-Volders M., Suter W., Elhajouji A. A flow cytometry based in vitro micronucleus assay in TK6 cells - validation using early stage pharmaceutical development compounds. Environ. Mol. Mutagen. 2011, 52:363-372.
    • (2011) Environ. Mol. Mutagen. , vol.52 , pp. 363-372
    • Lukamowicz, M.1    Woodward, K.2    Kirsch-Volders, M.3    Suter, W.4    Elhajouji, A.5
  • 23
    • 0021804940 scopus 로고
    • Correlated measurements of DNA, RNA, and protein in individual cells by flow cytometry
    • Crissman H.A., Darzynkiewicz Z., Tobey R.A., Steinkamp J.A. Correlated measurements of DNA, RNA, and protein in individual cells by flow cytometry. Science 1985, 228:1321-1324.
    • (1985) Science , vol.228 , pp. 1321-1324
    • Crissman, H.A.1    Darzynkiewicz, Z.2    Tobey, R.A.3    Steinkamp, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.