메뉴 건너뛰기




Volumn 83, Issue , 2013, Pages 135-147

Measurement of OEF and absolute CMRO2: MRI-based methods using interleaved and combined hypercapnia and hyperoxia

Author keywords

BOLD; CBF; CMRO2; Hypercapnia; Hyperoxia; Oxygen metabolism

Indexed keywords

DEOXYHEMOGLOBIN; OXYGEN;

EID: 84880958939     PISSN: 10538119     EISSN: 10959572     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2013.06.008     Document Type: Article
Times cited : (119)

References (56)
  • 1
    • 63849340506 scopus 로고    scopus 로고
    • Effects of aging on cerebral blood flow, oxygen metabolism, and blood oxygenation level dependent responses to visual stimulation
    • Ances B.M., Liang C.L., Leontiev O., Perthen J.E., Fleisher A.S., Lansing A.E., Buxton R.B. Effects of aging on cerebral blood flow, oxygen metabolism, and blood oxygenation level dependent responses to visual stimulation. Hum. Brain Mapp. 2009, 30:1120-1132.
    • (2009) Hum. Brain Mapp. , vol.30 , pp. 1120-1132
    • Ances, B.M.1    Liang, C.L.2    Leontiev, O.3    Perthen, J.E.4    Fleisher, A.S.5    Lansing, A.E.6    Buxton, R.B.7
  • 6
    • 84873707005 scopus 로고    scopus 로고
    • An analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach
    • Blockley N.P., Griffeth V.E.M., Germuska M.a, Bulte D.P., Buxton R.B. An analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach. NeuroImage 2013, 72:33-40.
    • (2013) NeuroImage , vol.72 , pp. 33-40
    • Blockley, N.P.1    Griffeth, V.E.M.2    Germuska, M.A.3    Bulte, D.P.4    Buxton, R.B.5
  • 7
    • 81355161550 scopus 로고    scopus 로고
    • Quantitative imaging of extraction of oxygen and tissue consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling
    • Bolar D.S., Rosen B.R., Sorensen A.G., Adalsteinsson E. Quantitative imaging of extraction of oxygen and tissue consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling. Magn. Reson. Med. 2011, 66:1550-1562.
    • (2011) Magn. Reson. Med. , vol.66 , pp. 1550-1562
    • Bolar, D.S.1    Rosen, B.R.2    Sorensen, A.G.3    Adalsteinsson, E.4
  • 9
    • 35148889974 scopus 로고    scopus 로고
    • Measurement of cerebral blood volume in humans using hyperoxic MRI contrast
    • Bulte D., Chiarelli P., Wise R., Jezzard P. Measurement of cerebral blood volume in humans using hyperoxic MRI contrast. J. Magn. Reson. Imaging 2007, 26:894-899.
    • (2007) J. Magn. Reson. Imaging , vol.26 , pp. 894-899
    • Bulte, D.1    Chiarelli, P.2    Wise, R.3    Jezzard, P.4
  • 13
    • 77953139478 scopus 로고    scopus 로고
    • Global cerebral oxidative metabolism during hypercapnia and hypocapnia in humans: implications for BOLD fMRI
    • Chen J.J., Pike G.B. Global cerebral oxidative metabolism during hypercapnia and hypocapnia in humans: implications for BOLD fMRI. J. Cereb. Blood Flow Metab. 2010, 30:1094-1099.
    • (2010) J. Cereb. Blood Flow Metab. , vol.30 , pp. 1094-1099
    • Chen, J.J.1    Pike, G.B.2
  • 14
    • 77956059098 scopus 로고    scopus 로고
    • MRI measurement of the BOLD-specific flow-volume relationship during hypercapnia and hypocapnia in humans
    • Chen J.J., Pike G.B. MRI measurement of the BOLD-specific flow-volume relationship during hypercapnia and hypocapnia in humans. NeuroImage 2010, 53:383-391.
    • (2010) NeuroImage , vol.53 , pp. 383-391
    • Chen, J.J.1    Pike, G.B.2
  • 15
  • 20
    • 62649111024 scopus 로고    scopus 로고
    • Variation in the shape of pulsed arterial spin labeling kinetic curves across the healthy human brain and its implications for CBF quantification
    • Gallichan D., Jezzard P. Variation in the shape of pulsed arterial spin labeling kinetic curves across the healthy human brain and its implications for CBF quantification. Magn. Reson. Med. 2009, 61:686-695.
    • (2009) Magn. Reson. Med. , vol.61 , pp. 686-695
    • Gallichan, D.1    Jezzard, P.2
  • 21
    • 84856998966 scopus 로고    scopus 로고
    • Magnetic resonance imaging of resting OEF and CMRO[U+2082] using a generalized calibration model for hypercapnia and hyperoxia
    • Gauthier C.J., Hoge R.D. Magnetic resonance imaging of resting OEF and CMRO[U+2082] using a generalized calibration model for hypercapnia and hyperoxia. NeuroImage 2012, 60:1212-1225.
    • (2012) NeuroImage , vol.60 , pp. 1212-1225
    • Gauthier, C.J.1    Hoge, R.D.2
  • 22
    • 0032818760 scopus 로고    scopus 로고
    • Simple analytic spiral K-space algorithm
    • Glover G.H. Simple analytic spiral K-space algorithm. Magn. Reson. Med. 1999, 42:412-415.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 412-415
    • Glover, G.H.1
  • 23
    • 84862998071 scopus 로고    scopus 로고
    • Spiral imaging in fMRI
    • Glover G.H. Spiral imaging in fMRI. NeuroImage 2012, 62:706-712.
    • (2012) NeuroImage , vol.62 , pp. 706-712
    • Glover, G.H.1
  • 24
    • 0033934775 scopus 로고    scopus 로고
    • Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR
    • Glover G.H., Li T.Q., Ress D. Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR. Magn. Reson. Med. 2000, 44:162-167.
    • (2000) Magn. Reson. Med. , vol.44 , pp. 162-167
    • Glover, G.H.1    Li, T.Q.2    Ress, D.3
  • 25
    • 79960641101 scopus 로고    scopus 로고
    • A theoretical framework for estimating cerebral oxygen metabolism changes using the calibrated-BOLD method: modeling the effects of blood volume distribution, hematocrit, oxygen extraction fraction, and tissue signal properties on the BOLD signal
    • Griffeth V.E.M., Buxton R.B. A theoretical framework for estimating cerebral oxygen metabolism changes using the calibrated-BOLD method: modeling the effects of blood volume distribution, hematocrit, oxygen extraction fraction, and tissue signal properties on the BOLD signal. NeuroImage 2011, 58:198-212.
    • (2011) NeuroImage , vol.58 , pp. 198-212
    • Griffeth, V.E.M.1    Buxton, R.B.2
  • 27
    • 84867866451 scopus 로고    scopus 로고
    • Venous oxygenation mapping using velocity-selective excitation and arterial nulling
    • Guo J., Wong E.C. Venous oxygenation mapping using velocity-selective excitation and arterial nulling. Magn. Reson. Med. 2012, 68:1458-1471.
    • (2012) Magn. Reson. Med. , vol.68 , pp. 1458-1471
    • Guo, J.1    Wong, E.C.2
  • 29
    • 33846085587 scopus 로고    scopus 로고
    • Quantitative BOLD: mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: default state
    • He X., Yablonskiy D.A. Quantitative BOLD: mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: default state. Magn. Reson. Med. 2007, 57:115-126.
    • (2007) Magn. Reson. Med. , vol.57 , pp. 115-126
    • He, X.1    Yablonskiy, D.A.2
  • 30
    • 53549089633 scopus 로고    scopus 로고
    • Validation of oxygen extraction fraction measurement by qBOLD technique
    • He X., Zhu M., Yablonskiy D.A. Validation of oxygen extraction fraction measurement by qBOLD technique. Magn. Reson. Med. 2008, 60:882-888.
    • (2008) Magn. Reson. Med. , vol.60 , pp. 882-888
    • He, X.1    Zhu, M.2    Yablonskiy, D.A.3
  • 32
    • 0032738184 scopus 로고    scopus 로고
    • Investigation of BOLD signal dependence on cerebral blood flow and oxygen consumption: the deoxyhemoglobin dilution model
    • Hoge R.D., Atkinson J., Gill B., Crelier G.R., Marrett S., Pike G.B. Investigation of BOLD signal dependence on cerebral blood flow and oxygen consumption: the deoxyhemoglobin dilution model. Magn. Reson. Med. 1999, 42:849-863.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 849-863
    • Hoge, R.D.1    Atkinson, J.2    Gill, B.3    Crelier, G.R.4    Marrett, S.5    Pike, G.B.6
  • 33
    • 79952028259 scopus 로고    scopus 로고
    • Beyond patient reported pain: perfusion magnetic resonance imaging demonstrates reproducible cerebral representation of ongoing post-surgical pain
    • Howard M.A., Krause K., Khawaja N., Massat N., Zelaya F., Huggins J.P., Vennart W., Williams S.C.R., Renton T.F. Beyond patient reported pain: perfusion magnetic resonance imaging demonstrates reproducible cerebral representation of ongoing post-surgical pain. PLoS One 2011, 6:e17096.
    • (2011) PLoS One , vol.6
    • Howard, M.A.1    Krause, K.2    Khawaja, N.3    Massat, N.4    Zelaya, F.5    Huggins, J.P.6    Vennart, W.7    Williams, S.C.R.8    Renton, T.F.9
  • 34
    • 34447553331 scopus 로고    scopus 로고
    • BOLD functional MRI in disease and pharmacological studies: room for improvement?
    • Iannetti G.D., Wise R.G. BOLD functional MRI in disease and pharmacological studies: room for improvement?. Magn. Reson. Imaging 2007, 25:978-988.
    • (2007) Magn. Reson. Imaging , vol.25 , pp. 978-988
    • Iannetti, G.D.1    Wise, R.G.2
  • 35
    • 77954242706 scopus 로고    scopus 로고
    • Interindividual variations of cerebral blood flow, oxygen delivery, and metabolism in relation to hemoglobin concentration measured by positron emission tomography in humans
    • Ibaraki M., Shinohara Y., Nakamura K., Miura S., Kinoshita F., Kinoshita T. Interindividual variations of cerebral blood flow, oxygen delivery, and metabolism in relation to hemoglobin concentration measured by positron emission tomography in humans. J. Cereb. Blood Flow Metab. 2010, 30:1296-1305.
    • (2010) J. Cereb. Blood Flow Metab. , vol.30 , pp. 1296-1305
    • Ibaraki, M.1    Shinohara, Y.2    Nakamura, K.3    Miura, S.4    Kinoshita, F.5    Kinoshita, T.6
  • 36
    • 2442553741 scopus 로고    scopus 로고
    • Database of normal human cerebral blood flow, cerebral blood volume, cerebral oxygen extraction fraction and cerebral metabolic rate of oxygen measured by positron emission tomography with 15O-labelled carbon dioxide or water, carbon monoxide and oxygen
    • Ito H., Kanno I., Kato C., Sasaki T., Ishii K., Ouchi Y., Iida A., Okazawa H., Hayashida K., Tsuyuguchi N., Ishii K., Kuwabara Y., Senda M. Database of normal human cerebral blood flow, cerebral blood volume, cerebral oxygen extraction fraction and cerebral metabolic rate of oxygen measured by positron emission tomography with 15O-labelled carbon dioxide or water, carbon monoxide and oxygen. Eur. J. Nucl. Med. Mol. Imaging 2004, 31.
    • (2004) Eur. J. Nucl. Med. Mol. Imaging , vol.31
    • Ito, H.1    Kanno, I.2    Kato, C.3    Sasaki, T.4    Ishii, K.5    Ouchi, Y.6    Iida, A.7    Okazawa, H.8    Hayashida, K.9    Tsuyuguchi, N.10    Ishii, K.11    Kuwabara, Y.12    Senda, M.13
  • 37
    • 0035384136 scopus 로고    scopus 로고
    • A global optimisation method for robust affine registration of brain images
    • Jenkinson M., Smith S. A global optimisation method for robust affine registration of brain images. Med. Image Anal. 2001, 5:143-156.
    • (2001) Med. Image Anal. , vol.5 , pp. 143-156
    • Jenkinson, M.1    Smith, S.2
  • 38
    • 0036425968 scopus 로고    scopus 로고
    • Improved optimization for the robust and accurate linear registration and motion correction of brain images
    • Jenkinson M., Bannister P., Brady M., Smith S. Improved optimization for the robust and accurate linear registration and motion correction of brain images. NeuroImage 2002, 17:825-841.
    • (2002) NeuroImage , vol.17 , pp. 825-841
    • Jenkinson, M.1    Bannister, P.2    Brady, M.3    Smith, S.4
  • 40
    • 10044279428 scopus 로고    scopus 로고
    • A signal processing model for arterial spin labeling functional MRI
    • Liu T.T., Wong E.C. A signal processing model for arterial spin labeling functional MRI. NeuroImage 2005, 24:207-215.
    • (2005) NeuroImage , vol.24 , pp. 207-215
    • Liu, T.T.1    Wong, E.C.2
  • 41
    • 0036334829 scopus 로고    scopus 로고
    • Analysis and design of perfusion-based event-related fMRI experiments
    • Liu T.T., Wong E.C., Frank L.R., Buxton R.B. Analysis and design of perfusion-based event-related fMRI experiments. NeuroImage 2002, 16:269-282.
    • (2002) NeuroImage , vol.16 , pp. 269-282
    • Liu, T.T.1    Wong, E.C.2    Frank, L.R.3    Buxton, R.B.4
  • 42
    • 49049091751 scopus 로고    scopus 로고
    • Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI
    • Lu H., Ge Y. Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI. Magn. Reson. Med. 2008, 60:357-363.
    • (2008) Magn. Reson. Med. , vol.60 , pp. 357-363
    • Lu, H.1    Ge, Y.2
  • 43
    • 16444386295 scopus 로고    scopus 로고
    • Experimental measurement of extravascular parenchymal BOLD effects and tissue oxygen extraction fractions using multi-echo VASO fMRI at 1.5 and 3.0T
    • Lu H., Van Zijl P.C.M. Experimental measurement of extravascular parenchymal BOLD effects and tissue oxygen extraction fractions using multi-echo VASO fMRI at 1.5 and 3.0T. Magn. Reson. Med. 2005, 53:808-816.
    • (2005) Magn. Reson. Med. , vol.53 , pp. 808-816
    • Lu, H.1    Van Zijl, P.C.M.2
  • 44
    • 0037016142 scopus 로고    scopus 로고
    • Brain size and grey matter volume in the healthy human brain
    • Lüders E., Steinmetz H., Jäncke L. Brain size and grey matter volume in the healthy human brain. Neuroreport 2002, 13:2371-2374.
    • (2002) Neuroreport , vol.13 , pp. 2371-2374
    • Lüders, E.1    Steinmetz, H.2    Jäncke, L.3
  • 45
    • 84859426095 scopus 로고    scopus 로고
    • Indication of BOLD-specific venous flow-volume changes from precisely controlled hyperoxic vs. hypercapnic calibration
    • Mark C.I., Pike G.B. Indication of BOLD-specific venous flow-volume changes from precisely controlled hyperoxic vs. hypercapnic calibration. J. Cereb. Blood Flow Metab. 2012, 32:709-719.
    • (2012) J. Cereb. Blood Flow Metab. , vol.32 , pp. 709-719
    • Mark, C.I.1    Pike, G.B.2
  • 46
    • 78649653567 scopus 로고    scopus 로고
    • Improved fMRI calibration: precisely controlled hyperoxic versus hypercapnic stimuli
    • Mark C.I., Fisher J.A., Pike G.B. Improved fMRI calibration: precisely controlled hyperoxic versus hypercapnic stimuli. NeuroImage 2011, 54:1102-1111.
    • (2011) NeuroImage , vol.54 , pp. 1102-1111
    • Mark, C.I.1    Fisher, J.A.2    Pike, G.B.3
  • 47
    • 70349966233 scopus 로고    scopus 로고
    • The QUASAR reproducibility study, part II: results from a multi-center arterial spin labeling test-retest study
    • Petersen E.T., Mouridsen K., Golay X. The QUASAR reproducibility study, part II: results from a multi-center arterial spin labeling test-retest study. NeuroImage 2010, 49:104-113.
    • (2010) NeuroImage , vol.49 , pp. 104-113
    • Petersen, E.T.1    Mouridsen, K.2    Golay, X.3
  • 48
    • 84862996748 scopus 로고    scopus 로고
    • NeuroImage quantitative functional MRI: concepts, issues and future challenges
    • Pike G.B. NeuroImage quantitative functional MRI: concepts, issues and future challenges. NeuroImage 2011, 62:1234-1240.
    • (2011) NeuroImage , vol.62 , pp. 1234-1240
    • Pike, G.B.1
  • 49
    • 84855446923 scopus 로고    scopus 로고
    • Vascular component analysis of hyperoxic and hypercapnic BOLD contrast
    • Schwarzbauer C., Deichmann R. Vascular component analysis of hyperoxic and hypercapnic BOLD contrast. NeuroImage 2012, 59:2401-2412.
    • (2012) NeuroImage , vol.59 , pp. 2401-2412
    • Schwarzbauer, C.1    Deichmann, R.2
  • 51
    • 0036828879 scopus 로고    scopus 로고
    • Fast robust automated brain extraction
    • Smith S.M. Fast robust automated brain extraction. Hum. Brain Mapp. 2002, 17:143-155.
    • (2002) Hum. Brain Mapp. , vol.17 , pp. 143-155
    • Smith, S.M.1
  • 53
    • 0031966050 scopus 로고    scopus 로고
    • Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
    • Wong E.C., Buxton R.B., Frank L.R. Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II). Magn. Reson. Med. 1998, 39:702-708.
    • (1998) Magn. Reson. Med. , vol.39 , pp. 702-708
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 54
    • 0035212159 scopus 로고    scopus 로고
    • Temporal autocorrelation in univariate linear modeling of fMRI data
    • Woolrich M.W., Ripley B.D., Brady M., Smith S.M. Temporal autocorrelation in univariate linear modeling of fMRI data. NeuroImage 2001, 14:1370-1386.
    • (2001) NeuroImage , vol.14 , pp. 1370-1386
    • Woolrich, M.W.1    Ripley, B.D.2    Brady, M.3    Smith, S.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.